3M ESPE

Curing Lights

Elipar FreeLight 2 Operating Instructions

Operating Instructions

98 Pages

Safety  ENGLISH ™  Elipar FreeLight 2 Fast-Curing Cordless LED Light Table of Contents Safety Glossary of Symbols Product Description Fields of Application Technical Data Charger Handpiece Charger and Handpiece Transport and Storage Conditions Installation of the Unit Factory Settings Initial Steps Charger Light Guide/Handpiece Insert the battery Battery Charging LED Display of the Charger Table Holder for the Handpiece Operation Selection of Exposure Mode Selection of Exposure Time Activating and Deactivating the Light Positioning the Light Guide Removing and Inserting the Light Guide from/into the Handpiece Measurement of Light Intensity Low Battery Charge Display Power-Down Mode Acoustical Signals - Handpiece Acoustical Signals - Charger Troubleshooting Maintenance and Care Replacement of the Battery Handpiece/Battery Care Cleaning the Light Guide Clean Charger, Handpiece,Table Holder, and Glare Shield Storage of the Handpiece during Extended Periods of Non-Use Disposal Customer Information Warranty Limitation of Liability  Page 1 2 3 3 3 3 3 3 4 4 4 4 4 4 4 4 4 5 5 5 5 5 5 6 6 6 6 6 7 7 7 7 7 8 8 8 8 8 8 8  PLEASE NOTE! Prior to installation and start-up of the unit, please read these instructions carefully! As with all technical devices, the proper function and safe operation of this unit depend on the user’s compliance with the standard safety procedures as well as the specific safety recommendations presented in these Operating Instructions. 1. The unit must be used in strict accordance with the following operating instructions. The manufacturer assumes no liability for any damage resulting from the use of this unit for any other purpose. 2. Prior to start-up of the unit make sure that the operating voltage stated on the rating plate is compatible with the available mains voltage. Operation of the unit at a different voltage may damage the unit. 3. The light must not be aimed at the eyes in order to avoid serious health consequences due to irradiation of the eyes. Exposure must be restricted to the area of the oral cavity in which clinical treatment is intended. 4. CAUTION! The Elipar FreeLight 2 unit generates high intensity light. The light emitted should be aimed directly above the material to be cured - exposure of the soft tissues (gingiva, oral mucosa, and skin) to high-intensity light should be avoided as such exposure may cause damage or irritation. If applicable, cover such areas. If exposure of soft tissues cannot be avoided, adjust the polymerization process to the light level, e.g. by shortening the polymerization times or increasing the distance between the light guide exit and the material to be cured. 5. Condensation resulting from the unit being transferred from a cold to a warm environment may be a potential risk. Hence, the unit should be turned on only after it is completely equilibrated to ambient temperature. 6. In order to avoid electric shock do not introduce any objects into the unit with the exception of replacement parts handled in accordance with the Operating Instructions. 7. Use original 3M ESPE parts exclusively to replace defective parts in accordance with these Operating Instructions. The product’s warranty does not cover any damage resulting from the use of third-party replacement parts. 8. Should you have any reason to suspect the safety of the unit to be compromised, the unit must be taken out of operation and labeled accordingly to prevent third parties from inadvertently using a possibly defective unit. Safety may be compromised, e.g. if the unit malfunctions or is noticeably damaged. 1  ENGLISH  SEITE 1 - 148 x 210 mm - 196/0/-/51+ F - SCHWARZ - 03-0288 (sr)
File Type: PDF
File Size: 2.14 MB
File Name: elipar_freelight_2_operating_instructions.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions