a-dec
A-dec Service Parts Q1 Edition Rev M Jan 2017
Service Parts
172 Pages
Preview
Page 1
2017 A-DEC SERVICE PARTS 1800 225 010
2017 Authorized Dealer Catalog Q1 Edition - View current catalog online Unpriced
Only genuine A-dec service parts keep A-dec equipment operating like new.
General Information
2017 Genuine A-dec Service Parts Catalog
3
Table of Contents GENERAL INFORMATION
TOOLS
HANDPIECE CONTROLS AND HOLDERS
Orders and Returns...6-7 General Information... 8 Warranty For A-dec Products... 9 Information Sources...10
Pliers, Cutters, Strippers, Hemostat, and Tubing Stringer...45 Gauges, Hex Wrench Set, Cable Ties, and Hex Driver...46 Syringe Tool, Touch-Up Paint, and Lubricant... 47
A-dec 500 and 300 Controls...77 Century Plus... 78-79 Century II... 80-81 Performer...82 A-dec 500 and 300 Holders...83 Handpiece Holders...84 Assistant’s Holders... 85-86 Handpiece Holder Valves... 87
A-DEC CLINICAL PRODUCTS
SELF-CONTAINED WATER SYSTEMS A-dec 500 and 300... 19-21 Cascade and Prior...22 COMPONENTS Diaphragms and Gaskets...23 O-rings... 24-25 A-dec 500 Covers and Caps...26 A-dec 300 Covers and Caps... 27-28 FITTINGS Barbed... 29-32 Pipe... 33-34 Tubing Poly-Flo...35 Quick-Disconnects (QD)... 36-37 A-dec 500 and 300...38 FLOOR BOXES Contoured...39 Stainless Steel...40 Plugs and Umbilical Components... 41 Moisture Separators and Air Filter/Regulators...42 Air and Water Filter/Regulators...43 Filter, Pre-Regulators, Gauge, and Shutoff Valve...44
VALVES Momentary...59 Manual On/Off and Coolant...60 Needle... 61 Relay...62 Shutoff and Selector...63 Micro and Actuator...64 Components...65 SYRINGES Tips and Retainers...67 Autoclavable Syringe Assemblies...68 Syringe Component Kits...69 Legacy Syringe Assemblies...70 Components... 71 Warm Water...72 FOOT CONTROLS
A-dec 500 and 300...89 A-dec 500 and 300 Data Cables and Circuit Boards...90 Power Supplies... 91 Power Supply Cables and QVIOLS...92 Touchpads...93 Cascade and Master Series Touchpads...94 Fuses...95 Air Electric Switches and Adapter Kit...96 VACUUM COMPONENTS HVE and SE Valves... 97 HVE and SE Service Parts...98 Aspirator Tips and Brushes...99 Performer Saliva Ejectors and Tailpieces for HVE and SE.100 A-dec 500 and 300...101 A-dec 300...102 Solids Collectors...103 Durr Connectors...104 Vacuum and ICV...105 Air Vacuum System...106 CUSPIDORS A-dec 500, 400, and 300...107 Cascade Vitreous China...108 Cascade Phenolic...109 Performer...110 Components... 111-112 Components and Performer Air Vacuum Generator...113
4
Assemblies...73 Components...74-76
ELECTRICAL COMPONENTS
General Information
Electric Motors Replacement Parts... 11-12 Intraoral Light Sources, Bulbs, and Tooth Dryer...13 Highspeed and Lowspeed Replacement Parts...14 Bur Tools and Pressure Gauge...15 Assistina... 16 Handpiece O-rings, Service Oil, and Spray Caps... 17 Lisa Sterilizer...18
TUBING 1/8” Color-coded Polyurethane and Vinyl...49 Color-coded Polyurethane...50 Silicone Handpiece Tubing... 51 Vinyl Handpiece Tubing...52 Handpiece Tubing, Nuts, and Bulbs...53 A-dec 500 and 300 High Volume Evacuator Vacuum Instrument Assemblies...54 A-dec 500 and 300 Saliva Ejector Vacuum Instrument Assemblies...55 Cascade & Performer High Volume Evacuator & Saliva Ejector Vacuum Instrument Assemblies...56 Large Bore (15mm) HVE Assembly for A-dec 500, 300, and Cascade Families... 57 Saliva Ejector, HVE, Vacuum and Umbilical, Flex, Foot Control, and Convolute...58
Table of Contents LIGHTS A-dec 570 LED Light Components...115 A-dec 300 Light Components...116 A-dec 500, Cascade, 6300, and Performer...117 6300 Light Components...118 6300 Components, Cables, and Light Posts...119 Performer Light Components... 120 CHAIRS AND STOOLS
DENTAL CABINETRY Preference II Hinges and Push Latches...137 Mounting Plates...138 Shelf Clips and Glass Door Components...139 Dispensers, Light, and Clock Timer...140
ACCESSORIES Tray Holders...153 Tray Holders, Trays, and Utility Shelf...154 Amalgamator and Bitewing Viewer Bulb...155 Monitor Mounts...156 Trays and Organizers...157 INDEX Numerical Index... 159-166 Alphabetical Index...167-169
General Information
Toeboard Covers...121 Upholstery Screws, Headrest Knobs, and Glide Bars... 122 Upholstery Replacement... 123-124 Chair Cylinders... 125 Chair Solenoids and Hydraulic Oil... 126 Power Supplies, Circuit Boards, and Capacitors...127 Chair Limit Switches and Position Sensor... 128 Switches and Base Down Stop... 129 Chair Brake Kits, Electrical Cables and Power Cords...130 Footswitches and Rear Cover Kit...131 Chair Mounts, Plugs and QD Kit...132 Chair Mounts...133 Cart and Stool Casters and Stool Knobs...134 Stool Cylinders and Back Cover...135
Preference ICC Dryer and Upper Storage Components...150 Miscellaneous...151
Preference II and Collection Cover Caps, Hole Plugs, and Subbase Trim Kit...141 Latches and Handles...142 Cable Chases and Grommets...143 Wash Station Components...144 Faucet Activation...145 Preference Collection Hardware...146-148 Glass Shelves, Gloves and Tissue Grommet...149
5
Orders and Returns WELCOME
General Ordering Details For U.S. and Canada, A-dec enters part orders from 7:00 a.m. until 4:00 p.m. daily (Pacific time). An order for sme day parts (in inventory) can ship same day if received before 2:00p.m. (Pacific time).
HOW TO FIND WHAT YOU NEED Service parts are placed under general product (Lights, Chairs and Stools) or functional categories. For instance, you will find the service parts for A-dec lights under the Lights tab.
• U.S. and Canadian Dealers: U.S. orders can ship UPS Red if received before 2:00 p.m. Pacific Time (PT) and UPS Ground, UPS Blue, or 3-Day Select if received by 4:00 p.m. (Pacific time). Canadian orders can ship same day if received by 2:00 p.m. (Pacific time).
Functional parts are included in tabs such as Fittings, Valves and Tubing. Functional parts are often used in multiple products and look similar enough to another part that side-by-side comparison makes it easier to order the correct part.
• Products shown in this catalog will be shipped: Domestic Customers F.O.B., Newberg, Oregon USA International Customers Ex-Works, Newberg, Oregon USA
HOW TO ORDER
• A 15% re-stocking fee applies to all returned merchandise other than those authorized for credit and/or warranty replacement.
Checklist Please include the following information with your order: c Part numbers c Quantity for each part ordered c Description c Ship-to address c Method of transportation c Approximate shipping date required c Purchase order number c Signature of person placing the order
• A 5% discount applies for prompt payment of domestic invoices paid within 20 days of invoice date, net 30 days, after shipment. The account balance must be current. This discount is not applicable to international invoices. • A-dec products are covered under the following UL file numbers for use in the United States and Canada: E182421, E243401, E320121, E340465, R18106 and SA33009
General Information
Your 2017 Genuine A-dec Service Parts Catalog will help service technicians and dealership parts ordering specialists find the right parts fast.
Contact Australia 1800 225 010 or Fax: 02 8332 4099 Monday through Friday, 8:30 a.m. to 5:00 p.m. (AEDT) other than holidays email: [email protected] Orders for A-dec products shown in this catalog must be placed through an authorized A-dec dealer and processed by A-dec Inc.
6
Orders and Returns HOW TO RETURN Return Policy Authorized dealers wishing to return unopened merchandise to A-dec for credit consideration must adhere to the following guidelines: Returns will not be accepted outside of 30 days from the invoice date. A return authorization must be obtained prior to returning parts to A-dec. Call A-dec Customer Service.
General Information 7
General Information LEGAL DETAILS Copyright © 2017 A-dec Inc. All Rights Reserved. 2601 Crestview Drive, Newberg, OR 97132 Printed in USA. A-dec Inc. makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. A-dec Inc. shall not be held liable for any errors contained herein or any consequential or other damages concerning the furnishing, performance or use of this material.
No part of this document may be copied, reproduced, altered, or t ransmitted in any form or by any means, electronic or mechanical, including photocopying, recording, or by any information storage and retrieval system, without prior written permission from A-dec Inc. Trademarks A-dec, the A-dec logo, A-dec 300, Cascade, Cascade Master Series, Century Plus, Continental, Decade, ICX, ICV, Performer, Preference, Preference Collection, Preference ICC, and Radius are trademarks of A-dec Inc. and are registered in the United States and other countries. A-dec 500, A-dec 400, A-dec 200, A-dec Inspire, and reliablecreativesolutions are also trademarks of A-dec Inc. None of the trademarks or trade names in this document may be reproduced, copied, or manipulated in any manner without the express, written approval of the trademark owner.
Certain modifications or alterations of A-dec equipment which expand the use of A‑dec equipment beyond its design and intent, or which override any safety features of A‑dec equipment may jeopardize doctor, patient, or staff safety. Field modifications that alter the electrical and/or mechanical safety of A-dec dental devices are in conflict with Underwriters Laboratory (UL) construction file requirements and are not sanctioned by A‑dec. Examples of field modifications that diminish safety design include, but are not limited to: rendering access to the line voltage without the use of tools, modification of supporting elements that increase or shift loading characteristics, and the addition of any powered device that exceeds the design limits of the dental system. The use of accessory equipment not complying with the equivalent safety requirements of A-dec equipment may lead to a reduced level of safety of the resulting system. It is the responsibility of the equipment distributor and the installer to assure that the installation complies with all building code requirements. The responsibility to determine whether a modification or alteration of A-dec equipment falls within these constraints is with the person(s) who initiates, approves and/or performs such modification or alteration. A-dec will not respond to inquiries on an individual basis. This person(s) will be deemed to have assumed all associated risks with such alteration or modification and will hold A-dec harmless from resulting claims, including product liability claims. Additionally, such modification or alteration voids A-dec’s warranty and may invalidate UL or other regulatory agency approval.
General Information
The information in this document is subject to change without notice. If you find any problems in the documentation, please report them to us in writing. A-dec Inc. does not warrant that this document is error-free.
EQUIPMENT ALTERATIONS
Certain touchpad symbols are proprietary to A-dec Inc. Any use of these symbols, in whole or in part, without the express written concent of A-dec Inc., is strictly prohibited. Alegra®, Endea®, Proxeo®, Synea®, and W&H® are registered trademark of W&H Dentalwerk Bürmoos GmbH (Austria). Acteon®, Newtron®, Satelec®, Sopro®, SoproCARE®, and SoproLIFE® are registered trademarks of Financiere Acteon SAS. NSK is a registered trademark of Nakanishi Inc. All other trademarks cited herein are the property of their respective owners.
8
Warranty For A-dec Products Terms & Conditions SCOPE
EXCLUSIONS
A-dec warrants all goods listed below against defects in material or workmanship under normal intended use when purchased from A-dec or an authorized A-dec dealer. A-dec’s sole obligation under the warranty is to provide parts for the repair, or replacement of any defective component with one that is equivalent to the original in performance. This warranty is in lieu of all other warranties or obligations express or implied. A-dec expressly disclaims all implied warranties of merchantability or fitness for a particular purpose. In no event will A-dec be liable for indirect, special, incidental, exemplary, or consequential damages of any kind.
The warranty does not cover:
The repair or replacement of components is contingent upon A-dec’s styles and color options available at the time of the warranty claim. If a warranty claim is filed after a product or color has been discontinued, A-dec reserves the right to honor the warranty in one of the following ways:
IV. Consumable products held beyond the expiration date shown on the packaging.
2. Replace the affected component, and other product components in the operatory with a product style and/or color similar to the originally purchased style and/or color. The buyer shall have no other remedy. The warranties set forth herein provide specific legal rights. Additional rights may exist, based on the jurisdiction of purchase and use of the product to the extent that those rights apply to this agreement. Warranty exclusions are identified in the following sections. Written notice of product failure must be given to A-dec within the warranty period. PERIOD The warranty period, measured from the date of delivery, shall be as follows: GOODS
WARRANTY
Hydraulic Dental Chair Cylinder (tilt and lift)
10 years
All Dental Chairs, Operator and Assistant Stools, Dental Lights, Delivery Systems, Monitor Mounts, Dental Furniture, and related components
5 years
Damage resulting from improper installation or maintenance, accident, misuse, abuse, neglect, alterations, freight damage, or natural disaster.
II. Damage resulting from the use of chemicals and process for cleaning, disinfecting, or sterilization. III. Normal service items such as (but not limited to): light shields, light bulbs, filters, o-rings, handpiece tubing, and water cartridges. Also, normal wear and tear is not covered. V. All other products, not manufactured by A-dec, including OEM, follow the original manufacturer’s warranty, and are not covered by A-dec’s warranty. Examples include, but not limited to: sterilizers, maintenance equipment, cameras, curing lights, ultrasonics, control modules, electric motors, attachments, handpieces, and turbines. Please contact A-dec Customer Service for specific warranty information. Failure to follow A-dec Instructions for Use (operation and maintenance instructions) will void the warranty. This warranty is effective for all new A-dec products, delivered after January 1, 2015.
General Information
1. Replace the affected component with a new component in the same style and/or color.
I.
Components replaced under warranty or purchased retain the balance of the original product warranty or are warranted for 1 year after delivery (whichever is greater).
9
Information Sources Here are some additional places to get the information you need. DOCUMENT LIBRARY The latest A-dec service documents, pre-installation guides, installation guides and other technical documents are available in PDF format from the document library on a-dec.com.
General Information 10
Electric Motors Replacement Parts EA-53 REPLACEMENT PARTS
PART NUMBER
PRICE
EA-50, EA-51LT, EA-52LED REPLACEMENT PARTS
PART NUMBER
PRICE
Halogen Bulb
O-rings (10)
Use with: EA-50, EA-51
Use with: EA-53
O-ring Installation Tool 23.1348.00
•F or A-dec|W&H handpieces
A-dec Clinical Products
t c . a g t n n o prici c r o l nd a t a r o s r P e b H & m u W rt n e h t a p o t l r a c e f o l e r r o e f s a a Ple strali Au c e d A
11
Electric Motors Replacement Parts EA-40LT, EA-41 REPLACEMENT PARTS
PART NUMBER
PRICE
Replacement Bulb
EA-30 REPLACEMENT PARTS
PART NUMBER
PRICE
Cordset Bushing, VE-6
Use with: EA-40LT, EA-50LT, EA-51LT
Use with: EA-30, EA-41
RM Fitting
Use with: EA-40LT
60W power supply
Use with: EA-40LT, EA-41
Power Cord for power supply Use with: EA-40LT, EA-41
EA-40LT, EA-41 POWER CORDS Integrated Power Cord Use with: EA-40LT, EA-41
PART NUMBER
PRICE
A-DEC | W&H EB-40LT | MC3 ELECTRIC HANDPIECE EB-40LT/MC3
E-coupling O-rings, (10)
•2 4V AC power cable for integrated version
Brushes (2) Bulb
Isolite MC2 (before 4/98)
E-coupling O-rings, (10) Bulb
PART NUMBER
PRICE
A-dec Clinical Products
t c . a g t n n i o pric c r o d l n a t a or ers P b H & m W rt nu e h t a p o t l r a c e f o l re for e s a a Ple strali Au c e d A
12
Intraoral Light Sources, Bulbs, and Tooth Dryer Quad Voltage Intraoral Light Source
Tooth Dryer
A-dec | W&H Replacement Bulbs
11.0232.00 • Fiber-optic intraoral light source • Requires fiber-optic handpiece tubing, 24vac • All IOLS come equipped to light (2) handpieces • A-dec 300 kit equipped to light (4) handpieces • To add additional handpieces order the QVIOLS Switch Kit
•F or tubing options, see tubing section • Handpiece only For 896, 898, 898-LE, TA-96L, TA-98L
For EB-40LT electric handpiece
IOLS kit for A-dec 300
PART NUMBER
PRICE
t c . a g t n n o prici c r Tooth Dryer Relay Valve o l nd a t a r o s r P e b H & m u W rt n e h t a p o t l r a c e f o l e r r o e f s lea tralia P Tooth Dryer End Cap Parts A-dec Replacement Bulbs us A c e d A
Quad Volt IOLS kit
for A-dec 300 (equipped to light (4) handpieces)
Coordinating Parts
Quad Volt IOLS kit for Performer
Quad Volt IOLS kit
For RA-24 Roto-Quick
34.0043.00
for 2122/2132
Quad Volt IOLS kit
•1/8" barb (1) 1/4" barbs (2)
for 3420/2561
Quad Volt IOLS kit
For LT25 lowspeed motor and 6-pin to 5-hole adapter
Spacer for 6-pin to 5-hole adapter
BULB BY HANDPIECE MODEL PART NUMBER
for 4631
for 896, 898, 898LE, TA-98L, TA-96L
QVIOLS Switch Kit
for EB-40LT electric handpiece
for EA-40LT, EA-50LT, EA51LT, AM-25LT and A-25LT electric motor
PRICE
A-dec Clinical Products
PRODUCT DESCRIPTION
EA-40LT, EA-50LT, EA-51LT, and A-25LT electric motor
for RA-24 Roto-Quick
38.0517.00
for LT25 lowspeed motor and 6-pin to 5-hole adapter
38.0054.02 (10)
bulb spacer for 6-pin to 5-hole adapter
EA-52LED Bulb
Xenon, 3.5V, .75A
0.06189400
035.034.01 (10)
38.0510.00
FOR 5-HOLE HANDPIECE TUBING
PRICE
13
Xenon, 3.5V, .75A
PART NUMBER
Highspeed and Lowspeed Replacement Parts LOWSPEED AIR HEAD ATTACHMENTS
PART NUMBER
PRICE
Turbine Replacements (Include cap remover and O-rings)
Contra Angle Head for WE-56 for WE-57 for WE-66 Tool Set
FIELD REPLACEMENT TURBINE BY HANDPIECE MODEL
for Alegra Lowspeed
Field Replacement Turbine
PART NUMBER
PRICE
TA-97 (2007 to 2014) ALEGRA GENERATOR
PART NUMBER
PRICE
TA-98 (2007 to 2014) TE-98 (Only for Alegra 300 series)
Handpiece Gaskets
* Does not include cap remover. Contact your territory manager for information on how to obtain a cap remover. NOTE: Turbines replaced receive a 1-year warranty.
TURBINE REPLACEMENT TOOLS
•S eals connection between handpiece and handpiece tubing terminal
3-hole
4-hole
HANDPIECE MODEL A-dec handpieces 3-hole Borden 4-hole Midwest
5-hole
A-dec|W&H fiber-optic handpieces 6-pin 5-hole W&H 5-hole A-dec only
6-pin
PART NUMBER
PRICE
Handpiece Cap Tool (before 2007)
Torque wrench tool set TA-97, TA-98 (2007 to 2014) Torque wrench tool set TE-97, TE-98 (Only for Alegra 300 series)
PART NUMBER
PRICE
A-dec Clinical Products
t c . a g t n n o prici c r o l nd a t a r o s r P e b H & m u W rt n e h t a p o t l r a c e f o l e r r o e f as alia e l P tr s u A c e A-d TE-97 (Only for Alegra 300 series)
RQ-54 Generator Replacement
14
Bur Tools and Pressure Gauge A-dec Handpiece Exhaust Muffler
Bur Tool for TC-80RM
98.0660.00
0.03303500
•A ttaches to any 4-hole vinyl handpiece tubing •P articularly effective in quieting handpiece exhaust inside the control head
RA-24 Bulb Tester
0.02752500
C0070900
•A dapts a 5-hole handpiece to 6-pin tubing
A-dec Clinical Products
ct g. a t n ricin o c or nd p l a t a r o s r P be H & m W rt nu e th l pa o t r a c e f o l e r r o e f s Handpiece Pressure Gauge (single) a a i l e l a P tr s u A c e A-d 6-Pin to 5-Hole Adapter
50.0271.00
•F it all handpiece couplers, except Borden 3-hole
15
Assistina Assistina Service Oil
Assistina Filters
PART NUMBER
0.02675930
In-line filter for 1/4" air line
0.02675200
Assembly
Aerosol filter
0.02670500
0.03102500
PRICE
Assistina Timer Assembly
Valve only
•B ulk service oil, .5-liter bottle •W hite Bottle
0.02686800
Assistina Supply Tube (with 3/8" compression)
Assistina Dosage Pump
0.02680230
0.02697030
0.03102000
• Includes filter
•B ulk Maintenance Solution 1-liter bottle •A pprox 7000 cycles •G reen Bottle
(Additional charge for shipping hazardous materials not included in price) NOTE: This is a next-day 24-hour part due to necessary shipping documentation
Fleece Liners 0.02690300 (5)
PART NUMBER
•A bsorbent liners for oil/debris collection tray
Push button assy
0.02683500
Spring, start button
0.02683200
O-ring (10)
0.02683901
•R equires (2) O-rings
A-dec Clinical Products
t c . a g t n n o prici c r o l nd a t a r o s r P e b H & m u W rt n e h t a p o t l r a c e f o l e r r o e f s a a Ple strali Assistina Push Button Coupler Stem O-rings Au c e d A
Assistina Maintenance Solution
PRICE
0.02695701 (10)
Service Tip Remember to replace the (2) O-rings on the Assistina coupler stem every 3 to 4 months.
16
Handpiece O-rings, Service Oil, and Spray Caps Service Oil and Spray Caps
A-dec | W&H O-ring Location Chart
PART NUMBER
PRICE
Highspeed handpieces 898, 896, TA-96L, TA-98L, TA-96LW, TA-98LW, TK/TG/TE series Between handle sheath and body of handpiece
0.02710700
Inside handle sheath on end toward Roto-Quick (Toplight)
0.02307300
Electric Motors and Lowspeed Motors 0.10940011
0.02229200
0.02038200
0.02036100
0.03522500
0.04396100
Replaces A-dec Handpiece Spray Lubricant
0.07072401
Seal for EA-53 Tubing
0.06893400
For AC-20, AC-20RM and AM-25 at E-coupling end (1 required)
0.01196920
t c . a g t n n o prici c r o l nd a t a r o s r P e b H & m u W rt n e h t a p o t l r a c e f o l e r r o e f as alia e l P tr s u A c e A-d
0.05773300
For EA-40LT, EA-50LT, EA-51LT, EB-40LT, A-25, A-25LT, AM-25A, AM-25LT and LT-25 electric motor (3 required), pkg 10
0.03304500
0.01862301
Roto-Quick
HANDPIECE MODEL
F1 Service Oil (Spray can, 400mL) Use with: all spray caps
Spray Cap, Highspeed & Motors
Use with: TA-97LED, TA-98LED, TA-98, TA-97, TE-97, TE 97LQ, TE-98, TE-98LQ, AM-25LT, AM-25A, AM-25, LT25, A-25LT, AC-20, Corsair Scaler, AP-44, AP-64U
Spray Cap, Attachments
Use with: WA-99LT, WA-86LT, HA-43A, HA-43LT, WA-66LT, WA-56LT, HP44M, WP-64MU, EB-79, EB-77, EB-75, WD-74M, WE-99LED G, WE-99A, WE-57, WE-56 LED G, WE-56A, WE-56, WE-66 LED G, WE-66A, WE-66, WE-66T, HE-43A, HE-43, WE-56 T/MW/SD, WE-57 T/MW/SD (Also used on older 100 series, 900 series, Trend, and Synea lowspeed attachments)
Spray Cap, Fixed Connection
Use with: TE-97RM, AP-44RM, RQ-54 for lubrication of generator (Also used on older 196RM, 198RM, 896RM, 898RM, TC-80RM, TC-95RM, A-dec handpieces and AC-20RM lowspeed motor)
Spray Cap, Synea LW
Use with: TA-97LW, TA-98LW
PART NUMBER 0.10940011
0.02229200
0.02060201
Gasket at coupler end for 4- or 6-hole connection, 904, 924, RA-24
0.02207300
RA-25 5-hole gasket
0.02201800
For coupling stem inside Assistina (2 required), pkg 10
0.02695701
O-rings for Assistina push button (2 required), pkg 10
0.02683901
0.03522500
0.05773300
Use with: WE-56 T/MW/SD, WE-57 T/MW/SD, WE-66T as an alternative option to 0.02038200
0.02060202
O-ring kit for RQ-04 and RQ-24 Roto-Quicks, pkg 3
0.02036100
Spray Cap, LN Highspeeds Dropper Bottle
O-ring kit for RA-24 and RA-25 Roto-Quicks, pkg 4
Assistina
0.02038200
0.04396100
Use with: TG-97LN, TG-98LN (Also used on NSK PTL connection)
0.07508900
(1 small, 2 large O-rings)
Spray Cap, LM Highspeed
Use with: TA-97LM, TA-98LM (Also used on Kavo Multiflex Lux connection)
PRICE
O-ring set for Roto-Quick
A-dec Clinical Products
Note: This is a next-day 24-hour part due to necessary shipping documentation
O-ring replacement for EA-53 tubing, pkg 10
0.03304500
17
Lisa Sterilizer Used Water Drain Kit
Drain Connector Kits
In-line Filter
54.0181.00
54.0063.00 gray
54.0066.01
54.0064.00 blue • Used for air and water filtration
•G ray for used water •B lue for fresh water
54.0019.00
54.0152.01
• 185 mm x 285 mm
54.0051.01
• Includes: (2) diaphragms (4) butterfly valves (4) O-rings (2) retaining clips (2) washers
54.0067.00
• T hree micron air filter •R eplace every 400 cycles
54.0047.00
Vacuum Pump
Door Seal
Drain Tubing
54.0050.01
54.0014.00 Door seal
54.0029.00
•R ecommended replacement every 1,000 cycles
• Magnetic sensor used in three locations on the water tanks to monitor water levels
A-dec Clinical Products
t c . a t Aluminum Traying n 4000 Cycle Service Kit o pric c r o l nd a t a r o Vacuum Pump Membrane KitP ers b H & num W e rt h t a p o Air Filter Water Level Sensor t l r a c e f o l e r r e fo s a a i Ple stral u A ec d A
• Replacement drain tubing
18
A-dec 500 and 300
1
3 4
8
5
8
9
6 7
9
10
REF
DESCRIPTION
1
Water bottle assembly
2
O-ring, AS568-006, 0.114 ID x 0.070 W
3
Connector, water
14.0457.00
4
Receptacle
14.0453.00
5
Retaining ring, external tooth, .187" ID
010.002.00
6
O-ring, N, 1.612 ID x .103 W (10)
031.130.01
7
Tube, supply, 8" long
14.0467.00
8
Clamp kit, water bottle
9
Screw, button head socket, 10-32 x 1/2
10
Water bottle with base
(includes 005.110.00)
WHITE
SURF
14.0468.01
14.0468.00
PRICE
030.006.02
90.1550.01
90.1550.00
005.110.00 14.0466.01
14.0466.00
Note: Use care when servicing this water bottle, be sure to align the clamp with the detent on the bottle to successfully reassemble the parts without causing damage.
Self-Contained Water Systems
2
19
A-dec 500 and 300
2 5 1
6 2 8 6
7
3 7
4
REF
DESCRIPTION
WHITE
SURF
1-6
Kit, remote mount, water bottle
14.0471.00
–
2-4, 6
Kit, chair mount, water bottle
14.0484.00
14.0464.00
4, 6
Kit, support center / slimline, water bottle
14.0464.02
–
1
Casting bracket
2
Housing, bottle
includes 20' tubing
includes 9.5' tubing
includes 3' tubing
bracket mounts to flat surfaces
77.0420.01 14.0455.04
14.0455.02
3
Screw, button head socket, 10-32 x 3/8
4
Bottle assembly, water
5
Screw
003.071.00
6
Receptacle assembly
90.1101.00
stainless steel
Socket head screw 10-32 x 1/2
8
O-ring, E, 0.921 ED x 0.139 W Jacket tubing 5/16 x 1/8 (per foot)
001.253.00 14.0468.01
14.0468.00
002.135.00 034.213.00 024.200.00
–
20
7
PRICE
Self-Contained Water Systems
3
A-dec 500 and 300 A-dec ICX® Waterline 2-liter Treatment Tablet
Hole Plug for Unit Plug, no water bottle, Surf 4
77.0263.00
90.1065.00 Case, 2-liter tablets
Plug, no water bottle, White 2
77.0263.01
Water Bottle Brush
018.094.00
049.070.00
Self-Contained Water Systems
Water Bottle Tubing Grommet
2-liter Water Bottle Cap
PRICE
•P lugs hole in front mount rigid arm when self-contained water bottle is not mounted
•C ase contains (36) boxes with (50) tablets each
•F or routing water bottle tubing through dental furniture • 3/4" (19 mm) • White
PART NUMBER
14.0491.01
21