amm215mwtd_operation_manual_rev_a.pdf
Page 1
AUTO - SCANNING WITH DIGITAL CONTROL
LCD COLOR MEDICAL MONITOR
AMM215MWTD
Operation Manual
For future reference, record the serial number of your display
monitor in the space below :
Serial Number
The serial number is located on the back of the monitor
Page 3
AMM215MWTD 1
ENGLISH
back of the monitor
WARNING
The title «WARNING» is used to inform the users of possible causes that could inflict the injury, death, or property
damage to the patients.
CAUTION
The title «CAUTION» is used to inform the users of possible causes that could inflict the patients although it might
not severe enough to cause deaths.
NOTE
The title «NOTE» is used to inform the users of items that
are of importance in terms of installation, operation, or
maintenance of the Equipment although the failure does
not inflict the bodily harm to the patients.
ADVAN INT’L CORP.2013
All other trademarks are the property of their reference owners.
This document is subject to change without notice.
Advan provides this information as reference only. Reference to other vendor’s
products does not imply any recommendation or endorsement.
Revision Control
Document Number
Rev. A
Page 4
2 User’s Guide
TABLE OF CONTENTS
Product Description and Intended Use.......................................................
Warnings and Cautions..............................................................................
Symbol Explanations..................................................................................
EU Declaration of Conformity for Medical Applications..............................
Safety Precaution.......................................................................................
Cleaning Your Monitor................................................................................
Recommendation to Use more than One Unit...........................................
On Burn-in..................................................................................................
Power Management Function....................................................................
Preset Modes..............................................................................................
Video Signals..............................................................................................
PIP / POP / PBP function...........................................................................
DDC............................................................................................................
Installation..................................................................................................
Connecting the Power Cord.......................................................................
User Function / Messages.........................................................................
OSD Section...............................................................................................
Troubleshooting..........................................................................................
Specification of (AMM215MWTD)..............................................................
Classification..............................................................................................
Electromagnetic Compatibility....................................................................
Dimension Drawing (mm) of AC Adapter....................................................
Dimension Drawing (mm) of AMM215MWTD.............................................
Connectors.................................................................................................
Description of Warranty..............................................................................
Touchscreen User’s Manual.......................................................................
Accessory Item List....................................................................................
3
4
7
8
9
9
9
9
10
11
12
13
14
14
15
16
17
25
26
27
28
30
31
32
33
37
39
Page 5
Product Description and Intended Use
Please check the following items are present when you unpack the box, and save
the packing materials in case you will need to ship or transport the monitor in future.
• AMM215MWTD LCD Monitor(the equipment that displays information,
graphic data, image and video on its LCD screen) and two video cables
(1) HD15 VGA cable (1) DVI-I cable
•
AC Power cord*
•
AC-Adapter
CAUTION
Model No : JMW1100KB1300F02
•
USB Cable**
•
User Manual, Quick Reference Guide and 4pcs VESA screws
Cable Cover
*Might vary pending on region standard
**Only available for touch models
ENGLISH
AMM215MWTD 3
Page 6
4
User’s Guide
Warnings and Cautions
Please read this manual and follow its instructions carefully. The words warning,
caution, and note carry special meanings and should be carefully reviewed:
Warning
The personal safety of the patient or physician may be
involved. Disregarding this information could result in
injury to the patient or physician.
Caution
Special service procedures or precautions must be
followed to avoid damaging the instrument.
Note
Special information to make maintenance easier or important
information more clear.
An exclamation mark within a triangle is intended to alert the
user to the presence of important operating and maintenance
instructions in the literature accompanying the product.
A lightning bolt within a triangle is intended to warn of the
presence of hazardous voltage. Refer all service to authorized
personnel.
Warning
TO AVOID POTENTIAL SERIOUS INJURY TO THE USER
AND THE PATIENT AND/OR DAMAGE TO THIS DEVICE,
THE USER MUST :
Warranty is void if any of these warnings are disregarded.
ADVAN Int’l Corp accepts full responsibility for the effects on safety, reliability, and
performance of the equipment only if:
• Re-adjustments, modifications, and/or repairs are carried out exclusively
by ADVAN Int’l Corp.
• The electrical installation of the relevant operating room complies with the
applicable IEC and CE requirements.
Warning
Federal law (United States of America) restricts this
device to use by, or on order of a physician.
The ADVAN Int’l Corp AMM215MWTD monitor has been tested under UL 60601-1
standard and UL listed for Medical application.
ADVAN Int’l Corp reserves the right to make improvements in the product(s)
described herein. Product(s), therefore, may not agree in detail to the published
design or specifications. All specifications are subject to change without notice.
Please contact ADVAN Int’l Corp directly or phone your local ADVAN Int’l Corp sales
representative or agent for information on changes and new products.
Page 7
1. Read the operating manual thoroughly and be familiar with its contents prior to using
this equipment.
2. Carefully unpack the unit and check if any damage occurred during shipment.
3. Should any solid object or liquid fall into the panel, unplug the unit and have it checked
by qualified personnel before operating it any further.
4. Uplug the unit if it is not to be used for an extended period of time. To disconnect the
cord, pull it out by the plug. Never pull the cord itself.
5. Be a qualified physician, having complete knowledge of the use of this equipment.
6. Test this equipment prior to a medical procedure. This monitor was fully tested at the
factory before shipment.
7. Avoid removing covers on control unit to avoid electric shock.
8. Attempt no internal repairs or adjustments not specifically detailed in this operating
manual.
9. Pay close attention to the care, cleaning instructions in this manual. A deviation may
cause damage (refer to the Cleaning section).
10. DO NOT STERILIZE MONITOR.
11. Read the entire instruction manual before assembling or connecting the camera.
12. Do not place the monitor or any other heavy object on the power cord. Damage to the
cable can cause fire or electirc shock.
13. Monitor with power supply is suitable for use in patient environment.
14. DO NOT stack more than 3 boxes high
This equipment has been tested and found to comply with the limits for medical devices in
IEC 60601-1-2:2003. These limits are designed to provide reasonable protection against
harmful interference in a typical medical installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to other devices in the vicinity. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to other devices, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving device.
- Increase the separation between the equipment.
- Connect the equipment into an outlet on a circuit different from that to which the other
device(s) are connected.
- Consult the manufacturer or field service technician for help.
NOTICES TO USER
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
FCC WARNING
This equipement generates or uses radio frequency energy. Changes or modifications not
expressly approved by the party responsible for compliance could void the user’s authority
to operate the equipment. The user could lose the authority to operate this equipment if an
unauthorized change or modification is made.
ENGLISH
Warnings
AMM215MWTD 5
Page 8
6
User’s Guide
Cautions
1. The AC Adapter must be plugged into a Grounded power outlet.
2. Use only the proprietary AMM215MWTD power supply for the
AMM215MWTD monitor. Make a proper connection by ensuring that the
shrink tubing completely secures the connection between the DC power cord and the
extension cord.
3. Turn power off when unit is not in use.
4. Never operate the unit right after having transported from a cold location directly to a
warm location.
5. Do not expose the monitor to moisture or directly apply liquid cleaners directly to the
screen. Spray the cleaning solution into a soft cloth and clean gently.
6. Handle the monitor with care. Do not strike or scratch the screen.
7. Do not block the monitor cooling vents. The monitor is cooled by natural convection
and has no fan.
8. Do not force the monitor past 28 degrees of vertical when adjusting the screen
position. (For monitors equipped with stands only.)
9. Remove the power module and connection when transporting the unit.
10. Save the original carton and associated packing material. They will be useful should
you have to transport or ship the unit.
11. Allow adequate air circulation to prevent internal heat buildup.
12. Do not place the unit on surfaces (rugs, blankets, etc.) or near materials (curtains,
draperies) that may block the ventilation slots.
13. Do not install the unit near sunlight, excessive dust, mechanical vibration or shock.
14. The unit is designed for operation in a horizontal position. Never operate the unit in
a vertical position.
15. Keep the unit away from equipment with strong magnets (i.e. a large loudspeaker.)
16. Do not expose the monitor to moisture or excessive dust.
17. Equipment with SIP/SOP connectors should either comply with IEC 60601-1 and/or
IEC 60601-1-1 harmonized national standard or the combination should be evaluated.
Do not touch the patient with signal input or output connectors.
18. Use only a hospital grade power supply cord.
19. This equipment has been tested and found to comply with the limit for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable generate uses and can radiate radio frequency energy, if not installed and
used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in
a particular installation, which can be detemined by turing the equipment off and on,
the user is encourage to try to correct the interference by one or more of the following
measures:
• Reorient or relocate the receiving device.
• Increase the separation distance between the equipment.
• Connect the equipment to an outlet on a circuit different from that to which the
other device(s) are connected.
• Consult the manufacturer or field service technican for help.
20. Grounding reliability can only be achieved when the equipment is connected to an
equipment receptacle labeled “Hospital Only” or “Hospital Grade.”
Note
To connect to an international power supply, use a an attachment plug
appropriate for the power outlet.
Note
Refer to the “Electromagnetic Compatibility” (EMC) section of this manual to
ensure EMC. The AMM215MWTD must be installed and operated
according to the EMC information provided in this manual.
Page 9
Symbol Definitions
Dangerous: High Voltage
Indicates protective earth
ground.
Direct Current
For indoor use only.
Serial Number
Tested to comply with FCC
Class B standards.
This way up
DC power control switch
Fragile, handle with care
Tested to comply with Japan
VCCI certification
Stacking limit by number
Tested to comply with China
CCC certification
Keep dry
China RoHS symbol. Number
indicates EFUP(Environmental
Friendly Use Period) from the
date of manufacturing.
Recyclable
Medical Equipment is in accordance with UL 60601-1 and
CAN/CSA C22.2 No. 601.1
in regards to electric shock,
fire hazards, and mechanical
hazards
51LJ
Medical Equipment
E215822
See accompanying document
Tested to comply with IP
(ingression protection) Rating
Indicates proof of conformity to applicable European
EconomicCommunity Council
directives and to harmonized
standards published in the official journal of the European
Communities.
WEEE symbol for the
recyclable product. Please do
not throw the product with this
symbol in the bin.
Authorized Representative in
Europe
Manufacturer
Date of Manufacture
ENGLISH
AMM215MWTD 7
Page 10
8
User’s Guide
EU Declaration of Conformity for Medical Applications
A Declaration of Conformity has been filed for this product. A sample
of this document may be found in the addendum which accompanied
this manual. For a copy of the Declaration of Conformity document,
please contact ADVAN Int’l Corp. and request for AMM215MWTD
DOC.
Prepare for Unpack
Before you unpack your monitor, prepare a suitable workspace. You
need a stable and level surface near a grounded wall outlet in an area
which is relatively free of glare from sunlight or other sources of bright
light. The monitor is cooled by natural convection (it has no fan).
For optimum performance, do not block the cooling vents.
While unpacking the monitor, inspect it and other package contents
for shipping damage that could cause a fire or shock hazard. Immediately report any shipping damage to the carrier or transportation
company and contact customer service for monitor in the future or in
case of return.
After you unpack the monitor, make sure the following items are included
• Monitor with video cable
• AC adapter with cable
CAUTION: AC Adapter must be plugged into Grounded a power outlet
CAUTION : AC adapter
Model No: JMW1100KB1300F02
• This operations manual
Note: Your system provider may offer alternative cords or cables
depending on the installation requirement and local geography issues.
Page 11
·
·
·
·
·
·
Avoid placing the monitor, or any other heavy object, on the power cord
to prevent fire or electrical shock from damage to the power cord.
Do not expose the monitor to rain, excessive moisture, or dust to avoid
fire or shock hazard.
Do not cover the slots or openings of the monitor for proper heat
dissipation. Always put the monitor in a place where there is adequate
ventilation.
Avoid placing the monitor against a bright background or where sunlight
or other light sources may reflect on the area of the monitor. Place the
monitor just below eye level.
Handle with care when transporting the monitor.
Refrain from giving the shock or scratch to the screen, as screen is
fragile.
CLEANING YOUR MONITOR
No specific liquid or chemical necessary when cleaning this LCD monitor
However, we suggest to clean the monitor with non-abrasive cloths and cleaning
solutions used in hospitals to clean similar equipment. We recommend using 70%
Isopropyl alcohol for the screen surface and warm water and a mild detergent for all
other surfaces. Other acceptable cleaning agents are listed below:
• 70% isopropyl alcohol
• Cidex (2.4% glutaraldehyde solution)
• 0.5% Chlorhexidine in 70% isopropyl alcohol
To clean the screen, do not spray liquid cleaners directly on to the unit. Stand away
Form the monitor and spray cleaning solution onto a cloth. Without applying excessive pressure, clean the screen with the slightly dampened rag.
Recommendation to Use more than One Unit
As unforeseen situation can occasionally occur for the monitor, when the display
is used for safety control of human, equipments or unstable picture, or for
emergencies, we strongly recommend you use more than one unit or prepare a
spare unit.
On Burn-in
Permanent burn-in may occur from the followings:
• Displaying color bar or static images repeately or for a long period of time.
• Using the unit repeatedly in a high temperature/ high humidity environment
• Displaying an image smaller than the monitor continuously.
To reduce the risk of burn- in, we recommend turning off the power of the unit, and
reducing the brightness when the unit is not in use.
ENGLISH
SAFETY PRECAUTION
AMM215MWTD 9
Page 12
10
User’s Guide
POWER MANAGEMENT FUNCTION
The monitor is equipped with the power management function which automatically
reduce the power consumption when not in use in three power level modes.
•
Stand-by Mode
The monitor goes into stand-by mode when the horizontal sync signal is off for
about 10 seconds. In this mode, the screen goes off and the power LED blinks
for 1 seconds On and 1 second Off. The screen is displayed after the horizontal
sync signal is restored.
•
Suspend Mode
The monitor goes into suspend mode when the vertical sync signal is off for
about 10 seconds. The power consumption during this is 8 W. In this mode, the
screen goes off and the power LED blinks for 1 seconds On and 1 second Off.
The screen is displayed after the vertical sync signal is restored.
•
Off Mode
The monitor goes into power-off mode when the vertical and horizontal sync
signals are off for about 10 seconds. In this mode, the screen goes off and the
power LED blinks for 1 seconds On and 1 second Off. The screen is displayed
after the vertical and horizontal sync signals are restored.
Power Management System
The AMM215MWTD Medical Monitor power management proposal. Provides four
phases of power-saving modes by detecting the horizontal sync signal as shown in
the table below.
State
Normal
Operation
DPMS
Standby
DPMS
Suspend
DPMS Off
Horizontal Sync
Active
Inactive
Active
Inactive
Vertical Sync
Active
Active
Inactive
Inactive
Video
Active
Blanked
Blanked
Blanked
Power Indicator
Green
Green Flashing (1
sec. Interval)
Green Flashing (1
sec. Interval)
Green Flashing (1
sec. Interval)
Power
Consumption
43 W
8W
8W
8W
When the monitor is power saving mode or detects an incorrect timing, the screen
will be blank and power LED indicator will blink.
Page 13
AMM215MWTD 11
ENGLISH
PRESET MODES
DVI and VGA input signal formats
Resolution
Horizontal
frequency
( KHz )
Vertical
frequency
( Hz )
Pixel clock
( MHz )
640 x 350 @70Hz
31.469
70.087
25.175
640 x 480 @60Hz
31.469
59.940
25.175
640 x 480 @75Hz
37.500
75.000
31.500
800 x 600 @56Hz
35.156
56.250
36.000
800 x 600 @60Hz
37.879
60.317
40.000
800 x 600 @75Hz
46.875
75.000
49.500
1024 x 768 @60Hz
48.363
60.004
65.000
1024 x 768 @70Hz
56.476
70.069
75.000
1024 x 768 @75Hz
60.023
75.029
78.750
1152 x 864 @60Hz
54.348
60.053
80.000
1152 x 864 @70Hz
63.955
70.016
94.200
1152 x 864 @75Hz
67.500
75.000
108.000
1280 x 1024 @60Hz
63.981
60.020
108.000
1680 x 1050 @60Hz
64.742
59.946
119.125
1680 x 1050 @60Hz
65.160
59.944
147.000
1600 x 1200 @60Hz
74.077
59.981
130.375
1920 x 1080@60Hz
67.500
60.00
148.500
Page 14
12
User’s Guide
Video Signals
Format
DVI 1
480/59.94i
480/59.94p
VGA
O
O
576/50i
O
576/50p
O
O
720/50p
O
O
720/59.94p
O
O
720/60p
O
O
1080/23.98p
O
O
1080/24p
O
O
1080/25p
O
O
1080/29.97p
O
O
1080/30p
O
O
1080/50i
O
O
1080/59.94i
O
O
1080/60i
O
O
1080/50p
O
O
1080/60P
O
O
Page 15
PIP / POP / PBP function*
The following combination options are available to you:
PIP
DVI 1
DVI 2
VGA
DVI 1
x
x
O
DVI 2
x
x
O
VGA
O
O
x
Main
*Not available for touch models
ENGLISH
AMM215MWTD 13
Page 16
14
User’s Guide
DDC
To make your installation easier, the monitor is able to Plug and Play with your
system if your system also supports DDC protocol. The DDC (Display Data
Channel) is a communication protocol through which the monitor automatically
informs the host system about its capabilities, for example, supported resolutions
and corresponding timing. The monitor supports DDC1 and DDC2B standard.
INSTALLATION
To install the monitor to your host system, please follow the steps as given below:
Steps
1. Use the supplied cable (DVI, VGA, USB*) then connect to the
host system accordingly.
2. Connect the DC power to the DC power connector on the monitor.
3. Connect one end of AC power cord into the AC Adapter and the other end to AC
power outlet.
4. Then turn the host system on and then the monitor.
5. If the monitor still does not function properly, please refer to the troubleshooting
section to diagnose the problem.
DC Power
*Only available for touch models
DVI
VGA
USB*
Page 17
ENGLISH
CONNECTING the POWER CORD
AMM215MWTD 15
* C
heck first to make sure that the power cord you use is the correct type required
for your area.
* T his monitor has an universal AC adapter that allows operation in either
AC 100 - 240 V ac voltage area. No user-adjustment is required.
* Plug one end of the power cord to the AC adapter, plug another end to a proper
AC outlet.
The cord set should have the appropriate safety approvals for the country in which
the equipment will be installed and marked HAR.
For 120 volt Applications, use only UL Listed deachable power cord with NEMA
configuration 5-15P type (parallel blades) plug cap. For 240 volt applications use
only UL Listed Detachable power supply cord with NEMA configuration 6-15P type
(tandem blades) plug cap.
Hospital-grade
power cord
Extension power cord (optional)
Manufacturer: Bridgepower
Part No: CB-47D2004P57MF (15ft) or
CB-47D2022P86MF (75ft)
Power Supply
Model No: JMW1100KB1300F02
AMM215MWTD
Page 18
16
User’s Guide
User Functions / Messages
Key Name and Function
Power LED : Lights up to indicate the power is turned ON.
Standby Power Button: To power ON or OFF the monitor.
Rotary switch : With the OSD menu activated, increases the value of the selected
(Turn Right)
parameter or moves rightward in OSD menu.
Rotary switch : With the OSD menu activated, increases the value of the selected
(Turn Left)
parameter or moves leftward in OSD menu.
PIP Switch* : To enable or disable Picture In Picture function.
PBP Switch* : To enable or disable Picture By Picture function.
POP Switch*: To enable or disable Picture On Picture function.
Adjust Switch* : To activate or deactivate image adjustment in sub screen of PIP,
PBP, POP mode.
Input Switch : To change the video source.
Power Switch : To turn ON or OFF the system.
Standby Power Button
Power Switch
How to access the menu.
1. Push the “Knob” button to activate the OSD menu.
2. Able to turn left or right the button to select those icons. The icon will be
highlighted when is selected.
3. Push the “knob” button to go into the another OSD menu.
4. Turn left or right “Knob” button to increase or decrease the number of selected
function.
5. In order to exit from the OSD menu in a different layer, then choose the “Exit
option”. In case of long pushing and holding the button around two or three
seconds, then it will completely out from the menu regardless wherever you are.
6. Turn the “Knob” button in a fast way to the left or right, while the menu is not
activated, then input signal menu will turns up with “V” mark which is chosen
current available input signal. You can switch to another input signal source by
turning the knob slowly then select the target source by pushing the knob.
*Not available for touch models
Page 19
AMM215MWTD 17
ENGLISH
OSD Section
Main Menu
Chromatic
Adjust Color Temp, Gamma
Visual
Adjust Brightness, Contrast, Phase*, Chroma*,
Sharpness-H, Sharpness-V
Setting
Adjust Scale Mode, Color Space*, Speaker, Freeze Frame,
Zoom / Pan, PIP**, POP**, PBP**
Advanced
Adjust OSD Position Control, Screen Control, DPMS, Auto
Source Select, Smart Select, Restore Factory, Key Lock,
Overscan
Information
Adjust Custom Entry, SN, Run Time, Input Format
Exit
Exit the menu
*Functions not available for AMM215MWTD
**Functions not available for touch models
Page 20
18
User’s Guide
OSD Section
Chromatic
Color Temp
Change the color temperature - D65, D93, S1, S2
Gamma
Change the gamma value - 1.8, 1.9, 1.95, 2.1, 2.1S, 2.2, 2.3,
2.4, 2.4S, S0, Radio graph
Exit
Exit the menu
Visual
Brightness
Adjust the brightness of panel (Range 0 - 100)
Contrast
Adjust the contrast of video (Range 0 - 100)
Phase*
Adjust the phase of video (Range 0 - 100)
Chroma*
Adjust the chroma of video (Range 0 - 100)
Sharpness-V
Set the sharpness of vertical image (Range 0 - 20)
Sharpness-H
Set the sharpness of horizontal image (Range 0 - 20)
Exit
Exit the menu
*Functions not available for AMM215MWTD
Page 21
AMM215MWTD 19
ENGLISH
OSD Section
Setting
Scale Mode
Change the scale mode - Fill all, One to One,
Vertical - fill, Horizontal - fill, Fill aspect ratio
Color Space*
Change color space between RGB and YPbPr
Speaker
Adjust volume (Range 0 - 100)
Freeze Frame
Off / On freeze frame
Zoom / Pan
Enable zoom - in and pan function
PIP**
Enable PIP (Picture In Picture) function
POP**
Enable POP (Picture On Picture) function
PBP**
Enable PBP (Picture By Picture) function
Exit
Exit the menu
*Functions not available for AMM215MWTD
**Functions not available for touch models
Page 22
20
User’s Guide
OSD Section
Sub menu of PIP*
Mode
PIP Mode ON / Off
Source
PIP sub screen source - VGA, DVI1/2
Position
PIP sub screen position - Top L, Top R, Bottom L, Bottom R
Size
PIP sub screen size - Small, Medium, Large
Blending
PIP sub screen blending (Range 0 - 20)
Swap
PIP sub screen swap
Exit
Exit the menu
Sub menu of PBP*
Mode
PBP Mode ON / Off
Source
PBP sub screen source - VGA, DVI1/2
Swap
PBP sub screen swap
Exit
Exit the menu
*Functions not available for touch models
Page 23
AMM215MWTD 21
ENGLISH
OSD Section
Sub menu of POP*
Mode
POP Mode ON / Off
Source
POP sub screen source - VGA, DVI1/2
Position
POP sub screen position - Top L, Top R, Bottom L, Bottom R
Size
POP sub screen size - Small, Medium, Large
Blending
POP sub screen blending (Range 0 - 20)
Swap
POP sub screen swap
Exit
Exit the menu
*Functions not available for touch models
Page 24
22
User’s Guide
OSD Section
Advanced
OSD Position
Change the OSD menu - Position, Background,
Control
OSD time out, Language
Screen Control
Control and adjust H and V position, Freqency, Phase
Noise Reduction*, Motion Offset*
DPMS
Change the DPMS
Auto Source
Adjust Auto Source Select between on and off
Select
Smart Select
Enable / Disable smart select sub menu
Restore Factory Changes the all OSD value to factory outgoing status
Key Lock
Set to key lock mode
Overscan
Adjust Overscan ratio
Exit
Exit the menu
*Functions not available for AMM215MWTD
Page 25
OSD Section
Sub menu of OSD Control
H-position
Adjust OSD H - position (Range 0 - 100)
V-position
Adjust OSD V - position (Range 0 - 100)
Back ground
Adjust transparency of OSD back ground (Range 0 - 20)
OSD Time out
Adjust OSD time out - 5s, 10s, 15s, 20s, 1m, 2m
Language
OSD language - English, Japanese, Chinese, Korean,
French, German
Exit
Exit the menu
Sub menu of Screen Control
H-position
Adjust screen H - position (Range 0 - 100)
*available for VGA
V-position
Adjust screen V - position (Range 0 - 100)
*available for VGA
Frequency
Adjust frequency (Range 0 - 100)
*available for VGA
Phase
Adjust phase (Range 0 - 100)
*available for VGA
Noise
Noise reduction (Range 0 - 31)
Reduction*
Motion Offset*
Motion offset (Range 0 - 100)
Exit
Exit the menu
*Functions not available for AMM215MWTD
ENGLISH
AMM215MWTD 23
Page 26
24
User’s Guide
OSD Section
Information
Custom Entry
Change the user or monitor’s name
SN
Display the serial number
Run Time
Display the total run time
Input Format
Display the current input resolution and vertical frequency
Exit
Exit the menu