Quick Reference Guide

2 Pages

AlphaRelief ® Quick Reference Guide QUICK REFERENCE GUIDE (For more detailed instructions, refer to the User Manual)  ALPHARELIEF Pressure Control Knob Run/Standby Indicator Wait Indicator Low Pressure Alarm  alphaRELIEF  140  120  ON  GHT IN WEI kg  80  ®  .  kg  Power Fail Alarm  WAIT LOW PRESSURE +40  POWER FAIL  Suspension Hook  Fuse Holder Run/Standby Switch Setting up instructions on rear  Run Standby Switch/ Switches the pump on and off. An internal battery will activate an Alarm Reset audible and visual alarm if the power supply is interrupted prior to switching off. Examples are mains lead removal and power failure. Once an alarm condition has been resolved, the pump can be reset by switching the pump to standby and back to run again using the Run/Standby switch on the side panel. ON  On  The green On indicator is illuminated on the front panel when the pump is running.  WAIT  Wait  The yellow Wait indicator is illuminated when the mattress is being inflated. The indicator will remain illuminated until the mattress has been fully inflated.  Low Pressure  The red Low Pressure indicator will flash whenever the pump detects low pressure within the mattress. An audible alarm will sound. The indicator will extinguish once normal pressure is reached. Check CPR stopper at the head end is securely inserted and the tubeset is connected properly.  Power Fail  The red Power Fail alarm indicator will start flashing when a mains power failure has been detected by the pump. An audible alarm will sound until power is resumed or the pump is switched off using the run/standby switch.  Manual Pressure Adjustment  The mattress cell pressure can be manually adjusted for individual patient weights using the dial on the pump face. Ensure that the patient is not bottoming out by unfastening one side of the AlphaRelief MR and sliding a hand underneath the cells. If you can freely put a flat hand under the patient the mattress is inflated correctly.  Transport Mode  The patient may be transported on the Alpha Relief MR by disconnecting the tubes from the pump and cross connecting them immediately. The pressure in the cells will equalise and the patient will be supported for up to 8 eight hours with the patient in the supine position.  LOW PRESSURE  POWER FAIL  140  0 12 80  H T IN WEIG kg .  kg  +40  For optimum use of the Transport facility set the mattress to Transport mode when all cells are inflated at cell cross over. Ensure that the patient remains in the supine position.
File Type: PDF
File Size: 91.1 KB
File Name: huntleigh_healthcare_alpharelief_quick_refence_guid.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions