ARJO Huntleigh Healthcare

Pressure Redistributing Mattress and Devices

Huntleigh Alphaxcell Quick Reference Guide Jan 2005

Quick Reference Guide Jan 2005

2 Pages

MRF-108 AlphaXcell® Quick Reference Guide (For more detailed instructions, refer to the User Manual)  Pressure Control Knob Run/Standby Indicator Wait Indicator 100  AlphaXcell®  Low Pressure Alarm  120 140  80  ON  Power Fail Alarm  WAIT  60  LOW PRESSURE 40 kg  POWER FAIL  Fuse Holder Run/Standby Switch Setting up instructions on rear Run Standby Switch /Alarm Reset  Switches the pump on and off. An internal battery will activate an audible and visual alarm if the power supply is interrupted prior to switching off. Examples are mains lead removal and power failure. Once an alarm condition has been resolved, the pump can be reset by switching the pump to standby and back to run again using the Run/Standby switch on the side panel.  ON  On  The green On indicator is illuminated on the front panel when the pump is running.  WAIT  Wait  The yellow Wait indicator is illuminated when the overlay is being inflated. The indicator will remain illuminated until the mattress overlay has been fully inflated.  Low Pressure  The red Low Pressure indicator will flash whenever the pump detects low pressure within the mattress overlay. An audible alarm will sound. The indicator will extinguish once normal pressure is reached. Check CPR stopper at the head end is securely inserted and the tubeset is connected properly.  Power Fail  The red Power Fail alarm indicator will start flashing when a mains power failure has been detected by the pump. An audible alarm will sound until power is resumed or the pump is switched off using the Run/Standby switch.  Manual Pressure Adjustment  The mattress overlay cell pressure can be manually adjusted for individual patient weights using the control on the pump face. Ensure that the patient is not bottoming out by unfastening one side of the mattress overlay and sliding a hand underneath the cells. If you can freely put a hand under the patient, the mattress overlay is inflated correctly.  Transport Mode  The patient may be transported on the AlphaXcell mattress overlay by disconnecting the tubes from the pump and cross connecting them immediately.  LOW PRESSURE  POWER FAIL  100  120 140  80  60  40  1  kg  2  The pressure in the cells will equalise and the patient will continue to be supported for up to 60 minutes with the patient in the supine position. For optimum use of the Transport facility set the mattress overlay to Transport mode when all the cells are inflated at cell cross over. Ensure the patient remains in the supine position.
File Type: PDF
File Size: 214 KB
File Name: huntleigh_healthcare_alphaxcell_quick_refence_guide.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions