BBraun
Cross connectors and replacement screws for cross connectors
14 Pages
Preview
Page 1
Aesculap® 6
1
Aesculap Spine
Note on the instructions for use for the S4® Spinal System – Lumbar/Deformity, TA011187 Cross connectors and replacement screws for cross connectors Hinweis zu Gebrauchsanweisung S4® Spinal System – Lumbar/Deformity, TA011187 Querverbinder und Ersatzschrauben für Querverbinder Remarque pour le mode d'emploi du système spinal S4® – Lombaire/Malformation, TA011187 Connecteurs transversaux et vis de rechange pour connecteurs transversaux Orientación sobre las instrucciones de manejo S4® Spinal System – Lumbar/Deformity, TA011187 Conectores transversales y tornillos de recambio para conectores transversales Nota sulle istruzioni per l’uso S4® Spinal System – Lumbar/Deformity, TA011187 Connettori trasversali e viti di ricambio per connettore trasversale Observações da instrução de utilização S4® Spinal System – Lumbar/Deformity, TA011187 Conectores transversais e parafusos de substituição para conectores transversais Aanwijzing tot gebruiksaanwijzing S4® Spinal System – Lumbar/Deformity, TA011187 Dwarsverbindingen en vervangingsschroeven voor dwarsverbindingen Anmärkningar till bruksanvisningen S4® Spinal System – Lumbar/Deformity, TA011187 Tvärförbindelse och reservskruvar för tvärförbindelse См. инструкцию по применению S4® Spinal System для лечения деформации поясничного отдела, TA011187 Поперечный коннектор и запасные винты для поперечного коннектор Upozornění k návodu k použití S4® Spinal System – Lumbar/Deformity, TA011187 Příčný stabilizátor a náhradní šrouby pro příčný stabilizátor Wskazówka do instrukcji użytkowania System S4® Spinal - Lumbar/Deformity TA011187 Łączniki poprzeczne i śruby zapasowe do łączników poprzecznych Pokyny k návodu na použitie S4® Spinálneho systému - Lumbar/Deformity, TA011187 Priečna spojka a náhradné skrutky pre priečnu spojku S4® Spinal Sistem – Lumbar/Deformity, TA011187 kullanım talimatına yönelik uyarı Çapraz bağlayıcı ve çapraz bağlayıcıya yönelik yedek cıvatalar
2
5
3
Aesculap AG | Am Aesculap-Platz | 78532 Tuttlingen | Germany Phone +49 (0) 7461 95-0 | Fax +49 (0) 7461 95-26 00 | www.aesculap.com Aesculap – a B. Braun company TA-Nr. 011560
02/13
V6
Änd.-Nr. 46076
Technical alterations reserved
4
Aesculap® Cross connectors and replacement screws for cross connectors Legend 1 2 3 4 5 6
Cross connector SW690T, SW691T, SW692T Cross connector SW693T, SW694T, SW695T, SW696T Cross connector SW697T, SW698T, SW699T Replacement screw SW689T, light blue Replacement screw SW688T matt silver Replacement screw SW687T pink
Intended use The replacement screws for cross connectors are used in cases where the gold-colored original screws have come completely loose in a cross connector. Note For cross connectors and replacement screws, the S4 Spinal System - Lumbar/Deformity, TA011187 instructions for use basically apply. The following information supplements the respective information in the instructions for use.
Materials Titanium wrought alloy Ti6Al4V acc. to ASTM F 136 or ISO5832-3, resp.
Application Diminished clamping stability due to incorrect application of screws! The cross connectors hold three different types of screws. ► Only use screws in their intended positions according their color coding (see Fig.)
WARNING
If an original, gold-colored screw has come completely loose in a cross connector: ► Always replace the screw with the correct replacement screw according to its color-coding. ► Never re-insert the original screw in a cross connector. Further information on Aesculap implant systems is always available from Aesculap or the appropriate Aesculap office. Cross connector
Replacement screw
SW690T, SW691T, SW692T (1)
SW687T pink (6)
SW693T, SW694T, SW695T, SW696T (2)
SW688T matt silver (5)
SW697T, SW698T, SW699T (3)
SW688T matt silver (5), SW689T light blue (4)
Distributor in the US/Contact in Canada for product information and complaints Aesculap Implant Systems LLC 3773 Corporate Parkway Center Valley, PA, 18034, USA TA-Nr. 011560