DenMat

Curing Lights

Sapphire plus Instructions for Use

Instructions for Use

13 Pages

Table of Contents  Warnings and Precautions  (Read completely through and understand before proceeding)  Warnings and Precautions ...1-2 Electromagnetic Compatibility ...3 Important Start-up/Set-up Instructions ...4 Device Description and Intended Use ...5-6 Controls and Functions...6 Control Panel...7 Accessories...7 Set-up and Operation Instructions...8 Light Meter (Radiometer)...9 Curing Mode... 9-10 Curing Instructions... 10 Bleach (Whitening) Mode...11-12 Whitening Instructions...12-15 Sanitizing and Sterilizing... 16 Replacement Parts... 16 Service... 16 Troubleshooting... 17  Each statement in this section is a WARNING Before connecting and operating the Sapphire® Plus, read all safety instructions. When used properly and with normal precautions, the Sapphire Plus is a safe and effective multi-purpose light system. However, the Sapphire Plus is a source of high electrical voltage, intense light, and heat. This product must only be used as indicated in this manual. This device must be used by Dental professional such as Board Certified Dentist or Orthodontist. Must have specific training in use of light curing systems. Must be familiar with complete instructions for use (especially all warnings, precautions and alerts). Do not shine light from the tip on anything other than indicated use (restorative materials which cure using photoinitiators). Shining light on combustible materials may CAUSE FIRE. Use only as directed. Maintain this practice even when you believe the lamp is off and cannot come back on. Before connecting the Sapphire Plus to the mains (the AC wall outlet), verify that the voltage to be applied is within the range of that specified on the identification label on the backside of the instrument. If you have any questions concerning the proper voltage, call the factory for clarification. To avoid risk of electric shock, disconnect the power cord before opening the lamp access door. Never remove the product cover. All repairs other than lamp and fuse replacement must be made by a factory authorized representative. Lamp replacement and fuse replacement must be done by a qualified service technician or by factory authorized representative. Do not touch or probe other electronic components inside the product. There is a risk of electric shock, even when the unit is disconnected from the AC wall outlet.  Lamp Replacement Instructions... 18  Do not modify this equipment. It is unsafe and voids the warranty.  Fuse Replacement... 19  Do not simultaneously touch the Sapphire main unit and the patient, either directly or through your body.  Transportation... 19  The unit generates high intensity light. The light travels down the light cable (warming the cable) and come out the end of the light guide. High-intensity light can be harmful to the eyes. When the system is in use, the patient, operator, and assistant(s) must all wear protective eyewear. Caution should be used to avoid accidentally starting the light outside of the mouth. To avoid possible injury, never look directly into the end of the light guide or directly into the light output on the front panel (even with protective eyewear). Never shine the light into the eyes. The provided Orange Safety Glasses Must be Worn at all times (Clinician and User) when using this equipment.  Storage ... 19 System Warranty... 20 Contact and Order Information... 21  PRECAUTION: When not in use, immediately turn off the power switch at the back of the device. Remove the tip from the end of the light guide handle. Remove the light guide from the light guide receptacle. This reduces risks associated with the light coming on expectantly. Never look into the light guide receptacle of the main Sapphire unit. Interlocks in the system are designed to prevent light from coming out of the receptacle, but if the system fails, intense light could come out of the receptacle. High-intensity dental lights should not be used by operators or on patients who may be photo-sensitive.  1
File Type: PDF
File Size: 2.03 MB
File Name: DenMat - Sapphire plus Instructions for Use.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions