DYONICS

Wound Therapy

RENASYS GO Quick Reference Guide

Quick Reference Guide

2 Pages

Modes of operation  Alarm Messages  Symbols Power Button Turns the device on and off. Battery Indication Shows the status of battery life. Flashes when the battery life reaches levels that require user intervention. Up Selector Allows the pressure setting to be increased and scroll through menu options. Down Selector Allows the pressure setting to be decreased and scroll through menu options. Keypad Lock Locks the keypad to restrict accidental adjustment of therapy. When activated the light will illuminate. Audio Pause/Alarm Suppress Silences the alarm for approximately 2-3 minutes.  Start Therapy/Select Allows therapy to be started or paused. It is also used to confirm settings within therapy.  For use with Soft Port  There are 2 modes of operation – Continuous and Intermittent.  ! !  Attention Low Battery  The battery has up to 3 hours therapy time remaining.  !! !!  RECHARGE V. L o w B a t t e r y  The battery has up to 1 hour therapy time remaining.  !! !!  RECHARGE Ex. Low Battery  The battery has only 2 minutes of therapy time remaining.  !! !!  RECHARGE NOW B AT T E RY FA I L  After 2 minutes in the extremely low state the device will power off.  1. Turn the device off.  !! !!  WARNING L O W VA C U U M  The vacuum level is low or there is a leak in the system for longer than 30 seconds. (See User Manual for details for resolution)  3. Press the  The system has encountered a high vacuum condition. (See User Manual for details for resolution)  4. Once therapy is started the display will show which mode of therapy has been selected.  !! !!  WARNING H I G H VA C U U M  !! !!  THERAPY STOP O V E R VA C U U M  !! !!  WARNING BLOCKAGE/FULL  !! !!  WARNING LEAK  !! !!  DEVICE FAILED Please Return  !! !!  A t t e n t i o n INACTIVE  The system has encountered an excessively high vacuum (of >235mmHg). (See User Manual for details for resolution) The system detects that the canister is full or that there is a blockage in the system. (See User Manual for resolution) The system has detected a significant leak for more than 1 minute. (See User Manual for resolution) The device has an unrecoverable error. (See User Manual for resolution) The device has been left in standby mode for longer than 15 minutes. Either select vacuum setting and start therapy or shut off the device until therapy is required.*  *This feature available with software version 0.66 and later.  Note: Continuous mode is recommended for NPWT. In the Continuous mode, the device will maintain the selected vacuum level without stopping until switched off. In the Intermittent mode, the device cycles on and off in increments of 5 minutes “ON” (active vacuum) and 2 minutes “OFF” (no vacuum). To change the therapy between Continuous and Intermittent mode: 2. Simultaneously press the Up or  mode and press the  Down +  Select +  Power buttons for 2 seconds.  Down buttons to move between Continuous and Intermittent  With over 150 years of experience in advanced wound care, Smith & Nephew is an industry leader providing innovative solutions to meet the needs of chronic, acute and traumatic wounds across all care settings.  - Remove paper tape around the canister tubing to release tubing to the full length. - Open both of the orange clips. - Align the canister so that the Volume marks are facing forward. - Push the canister gently over the inlet port of the device. - Engage both orange clips (clips will click when they are properly engaged).  2. Start up of device Welcome S t a r t i n g  VX.x  Press and hold the Power button for 2 seconds until start up message appears. 3. Select vacuum setting  4. Start therapy  Use Up and Down to adjust.  Press Select to start therapy.  5. Check dressing for a good seal  Smith & Nephew, Inc.  Customer Care Center 1-800-876-1261 T 727-392-1261 F 727-392-6914  1. Installing the canister  Select button to confirm.  Questions? For 24/7 NPWT clinical support, call 1-800-876-1261.  USA 970 Lake Carillon Drive Suite 110 St. Petersburg, FL 33716  Quick reference guide  Canada 2250 Alfred-Nobel Blvd. Suite 300 St-Laurent, Quebec H4S 2C9  www.smith-nephew.com www.myrenasys.com  Look for “raisin-like” appearance. Listen for a “hissing” sound, indicating a leak. Feel the dressing, which should be hard to the touch.  Customer Action Center T 1-800-463-7439 F 1-800-671-9140  ©2012 Smith & Nephew, Inc., All rights reserved. ™Trademark of Smith & Nephew. Certain trademarks registered in the US Patent & Trademark Office RA 5000  Possible site of leak Where Soft Port attaches to the film Wrinkle or crease Skin fold or crevice RNCE-06-0412-NAE  Intervention Pinch paste around drain (if applicable). Secure area where tube exits with blue tape (if applicable). Seal film edges with blue tape or Transparent Film. If hole found in Transparent Film, patch with additional Transparent Film.
File Type: PDF
File Size: 789 KB
File Name: renasys_go_quick_reference_guide.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions