Electrothermal
Model MH6616, X1 and X6 Instruction Book
Instruction Book
20 Pages

Preview
Page 1
SLIDE DRYING BENCH MH6616 / X1 / X6
INSTRUCTION BOOK
Page 1 of 20
M6627 Issue 7.0
Please take your time to read this Instruction book in order to understand the safe and correct use of your new Electrothermal product. It is recommended the Responsible Body for use of this equipment reads this Instruction book and ensures the user(s) are suitably trained in its operation. Section 1.
Introduction.
Page 3
Section 2.
Symbols and using this Instruction book.
Page 4
Section 3.
Safety Information.
Page 5
Section 4.
Unpack and Contents.
Page 7
Section 5.
Installation.
Page 8
Section 6.
Environmental protection.
Page 9
Section 7.
Production Operation.
Page 10
Section 8.
Technical Specifications.
Page 11
Section 9.
Maintenance
Page 12
Section 10.
Parts and Accessories.
Page 15
Section 11.
Customer Support.
Page 17
Section 12.
Notes.
Page 18
Section 13.
EC Declaration of Conformity
Page 20
Appendix ‘A’
Decontamination certificate
Page 16
© The copyright of this instruction book is the property of Electrothermal. This instruction book is supplied by Electrothermal on the express understanding that it is to be used solely for the purpose for which it is supplied. It may not be copied, used or disclosed to others in whole or part for any purpose except as authorised in writing by Electrothermal. Electrothermal reserve the right to alter, change or modify this document with out prior notification. In the interest of continued development Electrothermal reserve the right to alter or modify the design and /or assembly process of their products without prior notification. This product is manufactured in Great Britian by Electrothermal. Part of the Bibby Scientific Group of companies. Electrothermal. Electrothermal House. Unit12A, Purdeys Way. Purdeys Industrial Estate. Rochford, Essex. SS4 1ND Great Britain. Tel +44(0)1702 303350 Fax+44(0)1702 468731 [email protected] www.electrothermal.com
Page 2 of 20
M6627 Issue 7.0
1. INTRODUCTION 1.1.
Page 3 of 20
This Slide Drying Bench aids the preparation of microscope slides at the specimen mounting stage. Accepting up to 50 slides, it has the facility for drying slides in different orientations. The temperature control is provided by a built-in energy regulator controlling temperature up to 100C. The case and top are painted aluminium. The various options for mounting slides on the equipment are summarised in section 7.2.
M6627 Issue 7.0
2.
SYMBOLS AND USING THIS INSTRUCTION BOOK. 2.1. Throughout this Instruction book the following symbols are shown to identify conditions which pose a hazard to the user, or to identify actions that should be observed. These symbols are also shown on the product, or its packaging. When a symbol is shown next to a paragraph or statement it is recommended the user takes particular note of that instruction in order to prevent damage to the equipment or to prevent injury to one’s self or other people. The Responsible Body and the Operator should read and be familiar with this Instruction book in order preserve the protection afforded by the equipment. To prevent injury or equipment damage it is the manufacturer’s recommendation that all persons using this equipment are suitably trained before use. 2.2. Symbols defined. Caution, risk of danger. See note or adjacent symbol.
Protective conductor terminal to be earthed. (Do not loosen or disconnect).
Caution / risk of electric shock
Recyclable Packing Material
Do not dispose of product in normal domestic waste.
Caution. Hot surface.
Refer to Instruction book
Bio Chemical Hazard. Caution required. Will require decontamination.
Page 4 of 20
M6627 Issue 7.0
3.
SAFETY INFORMATION. This product has been designed for safe operation when used as detailed in accordance with the Manufacture’s instructions. NOTE: Failure to use this equipment in accordance with the manufacture’s operating instruction may compromise your basic safety protection afforded by the equipment and may invalidate the warranty / guarantee. The warranty / guarantee does not cover damaged caused by faulty installation or misuse of the equipment. 3.1. Prevention of Fire and Electric Shock. To prevent a risk of fire or electric shock, DO NOT open your product case without authorisation. Only qualified Service personnel should attempt to repair this product Replace fuses only with the type as listed in section, Parts and Accessories and Technical Specifications. (See fuse type and rating) Ensure the Mains Power Supply conforms to rating found on the data plate located on the back of this Product. Never Operate this equipment with out connection to earth / ground. Ensure the mains supply voltage is correctly earthed / grounded in accordance with current area legislation. 3.2. General Safe Operating Practice. Always follow good laboratory practice when using this equipment. Give due recognition to your company’s safety and legislative health & safety procedures and all associated legislation applicable to your areas of operation. Check laboratory procedures for substances being heated and ensure all hazards (e.g. explosion, implosion or the release of toxic or flammable gases) that might arise have been suitably addressed before proceeding. When heating certain substances the liberation of hazardous gases may require the use of a fume cupboard or other means of extraction. Do not position the product so that it is difficult to disconnect from the mains supply. Do not immerse unit in water or fluids.
Do not spill substances onto this unit. If spillage does occur, disconnect unit from mains supply and follow instructionas detailed in Section ‘Maintenance’. Do not cover this unit whilst in use.
It is not recommended to leave any heating apparatus unattended during operation. Only use Original Equipment manufacture’s spares and accessories. Ref Section 10.
Page 5 of 20
M6627 Issue 7.0
The equipment is not spark, flame or explosion proof and has not been designed for use in hazardous areas in terms of BSEN 60079-14:1997. Keep flammable, low flash point substances away from the apparatus. Do not operate or handle any part of this product with wet hands. Do not touch the heating surface whilst in use.
Do not lean or stretch over equipment.
Keep the Mains Plug and Lead set cable away from the heating surface.
Page 6 of 20
M6627 Issue 7.0
4.
UNPACKING AND CONTENTS. Please check the contents of this carton against the diagram.
Unit Serial Number
Unit Model/Cat Number.
For your future reference please record your products Serial and Model numbers.
Page 7 of 20
M6627 Issue 7.0
5.
INSTALLATION. 5.1. Electrical safety and installation. 5.1.1.
This equipment is designed to safe under the following conditions:-
Indoor use.
Altitude up to 2000 meters.
Temperatures between 5C and 40C.
Maximum relative humidity 80% for temperatures up to 31C decreasing linearly to 50% relative humidity at 40C.
Mains supply voltage fluctuations up to 10% of the nominal voltage.
Transient over voltages typically present on the mains supply.
Applicable rated pollution degree 2.
5.1.2.
This equipment must be earthed / grounded to a fixed earth / grounded mains socket outlet. The mains supply is to be earthed / grounded in accordance with current legislation.
5.1.3.
Ensure only the correct rated mains input fuses are fitted. (Where applicable ensure the correct mains cable fuse if fitted). See Technical Information Section 8 of the Instruction book.
5.1.4.
Check the voltage on the product data label of this unit. Ensure the rating conforms to your local supply.
5.1.5.
It is recommended this unit be connected to a mains supply source which incorporates an RCD or GFCI device.
5.1.6.
The unit is supplied with a moulded plug and mains lead set wired as follows. or
Green
=
Earth / Ground
Blue
or
White
=
Neutral
Brown
or
Black
=
Live / line hot.
Green / Yellow
5.2.
Install equipment is used on a clean, dry, non-combustible, solid work surface with at least 300mm suitable clearance all around from other equipment / objects.
Page 8 of 20
M6627 Issue 7.0
6.
ENVIRONMENTAL PROTECTION. 6.1. Electrothermal has given due consideration to environmental issues within the design and manufacturing process without compromising end product performance and value.
6.2.
Packaging materials have been selected such that they may be sorted for recycling.
6.3.
At the end of your product and accessories life, it must not be discarded as domestic waste. Ref: EU Directive 2002/96/EC on Waste Electrical and Electronic Equipment Directive (WEEE). Please contact your distributor / supplier for further information. For end users outside of the EU consult applicable regulations.
6.4. This product should only be dismantled for recycling by an authorised recycling company.
This product and accessories must be accompanied by a completed Decontamination Certificate prior to any disposal. Copies of the Certificate are available from your distributor of Electrothermal products, or you may copy and enlarge from ‘Appendix A’ of the instruction book.
Electrothermal is registered as Electrothermal Engineering Limited with the Environment Agency as a producer of WEEE through an authorised compliance scheme.
Page 9 of 20
M6627 Issue 7.0
7.
PRODUCT OPERATION This unit has been designed for safe operation when used as described in accordance with the manufactures instructions. Note: failure to use this equipment in accordance with the manufactures ‘Instruction book’ may compromise your basic safety protection afforded by this equipment and may invalidate the terms of the Warranty / Guarantee. 7.1. Overview. Your Slide Drying Bench has been designed for easy operation. The illustrations show a detailed layout of your Slide Drying Bench.
Item No 1 2 3 4 5 6 7 8 9 10
Description Support Bars Drying surface Hot surface warning Earth test point Carrying handles Power On indicator Heater On indicator Temperature control regulator knob and On/Off switch. Mains input IEC socket. Data plate label.
7.2. Place the slides to be dried on the bench surface. The slides can be arranged on the bench in a number of ways as illustrated.
7.3. Connect the unit to the mains power ensuring the correct voltage is being applied. The White ‘Power on’ Neon will illuminate. 7.4. Set the temperature control regulator knob to position 10. The Amber ‘Heater on’ neon will illuminate. 7.5. When the required bench temperature has been reached (this can be monitored using a suitable Surface temperature Probe) turn the regulator down to just maintain required temperature setting. The maximum temperature obtainable at setting 10 is 100C nominal. 7.6. When slides are dry, switch off the unit at the regulator knob and disconnect from the mains electrical supply. Allow slides to cool before further handling.
Page 10 of 20
M6627 Issue 7.0
8.
TECHNICAL SPECIFICATION. 8.1. Specification. Maximum power consumption.
150 Watts
Fuse rating (115V).
2.5 Amps (5 x 20mm dia Glass Quickblow)
Fuse rating (230V).
1.25 Amps (5 x 20mm dia Glass Quickblow)
Operational climatic conditions.
Temperature range 5C to 40C. Humidity not to exceed 80%.
Heating Element
Silicone Rubber Mat Heater.
Case Construction
Painted Aluminium.
Thermal Insulation
Ceramic Fibre sheet.
Capacity.
Maximum 50 slides at 76 x 25mm (3” x 1”).
Mains Supply Power.
230V-AC or 115/100V-AC @ 50/60Hz
Mains Power Lead set (UK) 13A BS1362
3 core earthed / ground. 2 meters long Moulded IEC plug and Lead set – supply cord H05 V V-F- Replace only with equivalent cable.
Mains Power Lead set (Europe)
3 core earthed / ground. 2 meters long Moulded IEC plug and Lead set – supply cord H05 V V-F- Replace only with equivalent cable.
Mains Power Lead set (USA)
3 core earthed / ground. 2 meters long Moulded IEC plug and Lead set – supply cord SJT VW 1- Replace only with equivalent cable.
Lead set plug fuse (UK – only)
13A
8.2. The Ingress Protection rating for this product is classified as IPX1 8.3. Dimensions & Weight (unpacked). Weight 1.8 Kg (4lb).
Page 11 of 20
M6627 Issue 7.0
9.
MAINTENANCE 9.1. General Information
Unplug the unit from the mains input voltage supply and allow it to cool before undertaking any maintenance tasks.
Maintenance should only be carried out under the direction of the Responsible Body, by a competent electrician. Failure to do so may result in damage to the product and in extreme cases be a danger to the end user. With proper care in operation this equipment has been designed to give many years of reliable service. Contamination or general misuse will reduce the effective life of this product and may cause a hazard. Maintenance for the unit should include:
Periodic electrical safety testing (an annual test is recommended as the minimum requirement). Regular inspection for damage with particular attention to the mains lead and plug set. Routine cleaning of the equipment should be undertaken using a clean cloth.
DO NOT USE SOLVENTS FOR CLEANING ANY PART OF THIS EQUIPMENT. 9.2. Fuse Replacement. The mains fuse holder is located at rear your product. Refer to Technical Specification, ‘Fuse Rating’ for correct fuse type and rating. Turn your product off and remove it from the mains supply. Open fuse draw and remove fuses. Fit replacement fuses and close the draw.
9.3. Replacing the Heater Mat. WARNING: The Insulation Pressure Plate contains insulation made from Refractory Ceramic Fibres (RCF) classified as a category 2 carcinogen under EU Directive 67/548/EC. Follow the guidelines for working with RCF as laid down in the ECFIA Code of Practise. In the event of a heater element becoming open circuit the following procedure should be adopted for its replacement. 9.3.1.
Page 12 of 20
Unplug and disconnect the unit from the power source.
M6627 Issue 7.0
9.3.2.
Unscrew and remove the screws retaining the top plate. Lift the top plate clear.
9.3.3.
Hinge back the heater mat and insulation pressure plate, the insulation should be carefully removed and placed on the top plate. This will reduce the risk of damage to the insulation.
9.3.4.
Remove any wire ties, now disconnect the heater leads from the amber neon.
9.3.5. 9.3.6.
9.3.7. 9.3.8.
Page 13 of 20
Connect the replacement mat. Replace wire ties and insulation and hinge the heater into position over the insulation. Place Top plate in position and refit all the fixing screws. The Responsible Body shall check the electrical safety of the unit before further use.
M6627 Issue 7.0
9.4. Spillage and Decontamination. In the event of spillage switch off and unplug this product from the mains electrical supply. Wipe off all excess liquid from the reaction block and surrounding area using an absorbent soft cloth. Allow sufficient time for any ingressed liquid to evaporate before commencing with use. If in doubt please consult Customer Support. Refer to section 10.
If the equipment has been exposed to contamination, the Responsible Body is responsible for carrying out appropriate decontamination. If hazardous material has been spilt on or inside the equipment, decontamination should only be undertaken under the control of the Responsible Body with due recognition of possible hazards. Before using any cleaning or decontamination method, the Responsible Body should check with the manufacturer the proposed method will not damage the equipment. Prior to further use, the Responsible Body shall check the electrical safety of the unit. Only if all safety requirements are met can the unit be used again. The above procedure is intended as a guide. Should spillage occur with a toxic or hazardous fluid then special precautions may be necessary. Decontamination Certificate. Note: In the event of this equipment or any part of the unit becoming damaged, or requiring service, the item(s) should be returned to the manufacturer for repair accompanied by a decontamination certificate. Copies of the Certificate are available from Distributor/Manufacturer. Appendix A of this instructions book may be copied and enlarged. At the end of life, this product must be accompanied by a Decontamination Certificate. See section 6.3 and 6.4
Page 14 of 20
M6627 Issue 7.0
10. PARTS & ACCESSORIES.
Heater Mat
230V AZ9136
115V AZ9137
Insulating Pressure Plate
AZ9138
AZ9138
Slide Support Rod Qty 4
AZ9139
AZ9139
Rubber Feet Qty 4
AZ9140
AZ9140
Neon Clear
AZ9141
AZ9142
Neon Amber
AZ9143
AZ9144
Handles Qty 2
AZ9145
AZ9145
Energy Regulator
AZ9127
AZ9128
Control Knob
AZ9133
AZ9133
Fuse
AZ9039 (F1.25A) AZ9040 (F2.5A)
Plug and lead set (UK)
M6902
-
Plug and lead set (Europe)
M6332
-
Plug and lead set (USA)
Page 15 of 20
-
M6288
M6627 Issue 7.0
APPENDIX ‘A’. DECONTAMINATION CERTIFICATE. Electrothermal. Electrothermal House. Unit12A, Purdeys Way. Purdeys Industrial Estate. Rochford. Essex. SS4 1ND. Great Britain Phone:+44(0)1702 303350 Fax:+44(0)1702 468731. E-mail: [email protected]
DECONTAMINATION CLEARANCE CERTIFICATE For the Inspection, Repair or Return of Medical, Laboratory or Industrial Equipment. Prior to a Service Engineer working on equipment that has been in an environment where substances hazardous to health may have been used, you are requested to provide the following information:
CUSTOMER DETAILS Company:Address:Department:Contact Name:Tel No:Fax No:-
Post Code:-
Product Description Model No:-
Serial No:-
Has the equipment been exposed to any of the following, Please answer all questions by deleting YES/NO as applicable and by providing details in section 2 below. A. Blood, body fluids, Pathological specimens
YES/NO
Provide details if YES
B. Biodegradable material that could become a hazard
YES/NO
Provide details if YES
C. Other biohazard
YES/NO
Provide details if YES
D. Chemical or substances hazardous to health
YES/NO
Provide details if YES
E. Radioactive substances State name(s) and quantities of isotopes and checks made for residual activity F. Other hazards
YES/NO
Provide details if YES
YES/NO
Provide details if YES
2. Please provide details of any hazard present as indicated above. Include details of names and quantities of agents as appropriate:3. Your method of decontamination (please describe):4. Are there likely to be any areas of residual contamination (please specify)
I declare that the above information is true and complete to the best of my knowledge and belief. Authorised signature:-
Name (please print):-
Title/Position:For and behalf of:-
Page 16 of 20
Date:-
M6627 Issue 7.0
11. CUSTOMER SUPPORT. For help and support in using this product, please contact at the following address.
Electrothermal. Electrothermal House. Unit12A, Purdeys Way. Purdeys Industrial Estate. Rochford, Essex. SS4 1ND Great Britain. Tel +44(0)1702 303350 Fax+44(0)1702 468731
E-Mail: [email protected]
Page 17 of 20
M6627 Issue 7.0
12. NOTES
Page 18 of 20
M6627 Issue 7.0
Page 19 of 20
M6627 Issue 7.0
13. EC DECLARATION OF CONFORMITY. CE marked products and associated accessories covered by this Instruction book conform to the essential requirements of the following directives: EMC Directive. Low Voltage Directive. A full copy of the EC Declaration / Conformity document can be obtained from the manufacture at the email address [email protected]
Electrothermal. Electrothermal House. Unit12A, Purdeys Way. Purdeys Industrial Estate. Rochford, Essex. SS4 1ND Great Britain. Tel +44(0)1702 303350 Fax+44(0)1702 468731 Email: [email protected] Http www.electrothermal.com For the America’s and Canada, contact: Techne Incorporated, 3 Terri Lane, Suite 10 Burlington, NJ 08016 USA. Toll free:800-225-9243Tel: 609-589-2560 Fax: 609-589-2571 Email: [email protected] Http www.techneusa.com
2011 Electrothermal. All rights reserved. Printed in Great Britain
Page 20 of 20
M6627 Issue 7.0