GE Healthcare

Giraffe, Lullaby and Panda Neonatal Systems

Giraffe OmniBed and Incubator Wiring Diagram

Wiring Diagram

3 Pages

4  3  J21.1 J21.2 J21.3 J21.4 J21.5 J21.6 J21.7 J21.8 J21.9 J21.10  Configuration Plug Group 1  PHASE  6600-0800-700  NEUTRAL AC GND  Elect. Enclosure  Elect. Enclosure  PHASE 6600-0517- 602  red white blue green black brown orange yellow  +5 V +5V +5V GND GND GND GND +12V +12 V  6600-1027-600  F1  J41.1 J41.2 J41.3 J41.4 J41.5 J41.6 J41.7 J41.8  6600-0708-700 red  J48.1 . J48.2 J48.3 .  black  NEUTRAL 6600-0517- 602  GND J42.1 +5V J42.2 +12V J42.3 +5VSTBY J42.4  6600-0718-700  Rail Components  6600-0883-700 (X2)  HOOD MIDDLE SW  shield  HOOD DOWN SW  6600-1238-600  brown black  brown black  shield  West Rail  Card Cage  HOOD MOTOR  Card Cage  East Rail  B  East Rail  M  East Rail  East Rail  black  .J49.1 .J49.2 J38.1 J38.2 J38.3 J39.1 J39.2  Base Pedestal  DOWN  Ebase East Foot  1 2 3 4 5  UP  6600-0877-700  ESD shield  red brown black shield  1 2 3 4 5  white orange blue green red black  11 22 33  6600-0750-700  DOWN  Ebase West Foot  1 2 3 4 5  UP  6600-0877-700  ESD shield  SPEAKER  6600-1168-600  Ebase Pedestal  1 2 3 4  ESD shield  6600-0737-701  1 2 3 4  1 2 3 4  West 6600-0737-702  ESD shield  brown black shield  1 2 3 4  J30.1 J30.2 J30.3 J30.4 J30.5 J30.6 J30.7 J30.8 J30.9  J33.1 J33.2 J33.3 J33.4 J33.5  J45.1 J45.2  Ebase Pedestal  . .  PHASE  F3  SW2/NEUTRAL  F4  Ebase Pedestal  out .  Ground Equalization Post  .  6600-0870-700 Heatsink Bed Chassis Cover 2 NO.  REVISED AND REDRAWN REVISIONS  02-7323 8/12/02  Elect. Enclosure Elect. Enclosure  Elect. Enclosure  J54.1 . J54.2 J54.3 J54.4 .  AC Expansion  PHASE  J53.1 J53.2 J53.3 J32.1 J32.2 J32.3  SW/NEUTRAL PHASE NEUTRAL  3 2 1  5 6 7  Humidity Sensor (bottom view) 2  t  1 2  6600-0784-700 C  Heatsink Thermistor 6600-0819-700  Expansion Slots  2  t  6600-0702-700  1  1  1  1  1  black brown red  1 2 3 4 5 6 7 8 9  orange yellow green blue violet  red black green  1 2 3 4 5 6 7 8 9  yellow brown blue orange grey  red brown black shield  1  Black  blue green/yellow brown  6600-1165-600 + -  AC AC  + -  6600-1057-600 1 2 3 4 5  6600-0729-700  1 2 3 4 5  red black brown orange yellow  HTR DOOR OPEN  HTR DOOR CLOSED HTR DOOR OPEN  Heater Door Switches 6600-1154-600  . .  J51.1 J51.2 J51.3  Radiant Warmer  (Shown with heater doors in closed position) blue green brown  1 2 3  1 2 3  black green black  1 2 3  1  Heater  2  Heater Housing  6600-0867-700  6600-1535-700  6600-1177-600  6600-0747-700 B  Configuration Plug yellow blue  6600-0748-701 ONLY  6600-1003-600  Incubator Airflow Motor  M  1 2 3  6600-0710-700  Solid State Relay  A B C  orange yellow black  11 22 33 44  6600-0882-700  Isolation Transformer  Solid State Relay AC AC  1 2  2  white white  1 2  6600-1041-700 x 2 orange white  6600-0864-700  1 2  1 2 blue  2  1  1  Tstat  2  black  green black  Incubator  Heater (X2)  white white  black white  1  6600-1019-600  6600-0709-700 Optical Fan Sensor  Humidifier Isolation Transformer 6600-1328-600 brown black  No Connection J56.1 J56.2  red orange  115 VAC Configured 1  T1  7  2 5  8 11  6  12  230 VAC Configured 1  yellow  2 5 6  T1  6600-0820-700  Configuration Plug Group 2  7  8 11 yellow 12  grn/yel black brown brown  Elect. Enclosure  6600-0802-700  Humidifier  Add Water Tstat 44 33 22 11  green red white white  1  2  1  2  Heater 6600-1018-600  6600-0714-700  6600-1526-700  brown  11 22  brown  6600-0803-700 1  1  2  black  brown black shield  Overtemp Tstat 6600-1013-600  1 2 3 4  1 2 3 4  red brown black shield  Rh Bottle Open Sw Rh Bracket  6600-0730-700  6600-1519-700  2  J56.5 J56.6 3  1  4  2  P G N A  Power Switch/Circuit Breaker 6600-1014-601 (9 Amp, 230V) 6600-1014-602 (12 Amp, 115V)  brown black red brown black  1  2  1  2  6600-0562-603 X2  brown blue  6600-0583-600 (X3)  3  Elect. Enclosure  Line Filter Elect. Enclosure  6600-1006-600  6600-0731-700 UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES TOLERANCES ARE:  Circuit Breakers 3.5A.  shield  Outlets  4  yellow green blue black  green red white brown orange blue  J6.1 J6.2 J6.3 J6.4 J6.5 J6.6  red black  BY 5  t  6600-0716-701  6600-1003-600  RYP AHR  ECO DATE  blue  Humidifier Isolation Adapter Board 6600-1525-700  PCB SSR  6600-0863-700 (X2)  RT5  black  F4.1 F4.2  6600-1119-6 00 in  1 2  2  t  2  RT4 1  1 2 3  6600-1226-600  Elect. Enclosure  red  F4  A  1 2 3  White  Configuration Plug Group 1  Brown Orange Yellow Blue  F3.1 F3.2  Main Bracket  2  t  6600-0798-700 (reusable) or 6600-0799-700 (disposable) 1  calibrate mode short 5 to 6 and 7 to 8  brown  RT3  Patient Probe  6600-0701-700  black red  F3  6600-0237-700  6600-0743-700  J50.1 J50.2  t  1 2 3 4  2 1  t  HTR DOOR CLOSED  115V=6600-1324-602 230V=6600-1324-601  PHASE SW/NEUTRAL  11 22  5 6 7  6600-0752-700  Fuse F3 and F4  6600-0753-701  3 2 1  RT2  1  red black  1  red brown black shield  6600-0711-700  white brown  EBASE ASSEMBLY  Hood Foot Activate  J40.1 J40.2 J40.3 J40.4 J40.5 J40.6  6600-0713-700  M  Hood Foot Activate East  shield  yellow orange brown green red black  Ebase Pedestal 6600-0715-700  red brown black shield  1 2 3 4 5  11 22 33 44 55 66  RT6  1 2 3 4  6600-0742-700  2  RT7 1  1 2 3  normal mode short 1 to 2 and 3 to 4  Jumper  6600-0816-700  PHASE SW/NEUTRAL  yellow green blue black  orange blue red green  6600-0815-700  J46.1 J46.2 J46.3  red shield  Elect. Enclosure  Elect. Enclosure  J36.1 J36.2 J36.3 J36.4 J36.5 J36.6 J36.7 J36.8 J36.9  brown black  shield  J31.1 J31.2 J31.3 J31.4  1 2 3  JP1.1 JP1.2 JP1.3 JP1.4 JP1.5 JP1.6 JP1.7 JP1.8  1 2 3 4 5 6  HOOD UP SW  1  black brown red  6600-0704-700 F2  1 2 3 4  1 12 23 34 4  Power Supply  J47.1. J47.2 .  1 2 3 4  1 2 3 4 5 6  red black  D  Humidity Sensor (bottom view)  blue green yellow orange shield  1 2 3 4  1N5817  BATTERY 6600-1024-600  J2.1 J2.2 J2.3  6600-0716-702  black brown red  1 2 3 4 5  1 2 3 4 5 6  4  PT 1  green yellow blue shield  1 2 3 4 5  1 2 3 4  3  2  J43.1 J43.2 J43.3 J43.4  J4.1 J4.2 J4.3 J4.4  shield  black brown  J3.1 J3.2  PT 2  RT1 brown black orange red  1 2 3 4 5 6  1  6600-1216-600  1 2 3 4  2  Standby Switch  1 2 3 4  red black red black  300  brown black orange red green yellow blue  1 2 3 4  1  red black red black  red orange yellow green blue  2  t  brown  6600-1512-700  1 2 3 4 5 6  6600-0707-700  brown  6600-1513-700 J1.1 J1.2 J1.3 J1.4 J1.5 J1.6 J1.7  J5.1 J5.2 J5.3 J5.4  blue orange  1  3 2  4  6600-0617-700 yellow brown  Elect. Enclosure  C  NURSE CALL 6600-0243-700  Control Board 6600-0705-700  1 2 3 4  PHASE SW2/NEUTRAL  6 5 4 3 2 1  J52.1 . J52.2 .  6600-0724-700 RELAY BOARD  black green yellow  1 2 3 4 5 6  J44.1 J44.2 J44.3 J44.4  black white  5  7 6  Configuration Plug Group 1 8  Ebase / Hood Transformer 6600-1023-600  red white violet black  RT2 2 1  t  red black  1 2 3 4 5 6 7 8  1 2 3 4 5 6 7 8 9  1 2 3 4  Card Cage  J9.1 J9.2 J9.3 J9.4 J9.5 J9.6 J9.7 J9.8 J9.9 J9.10 J9.11 J9.12 J9.13 J9.14 J9.15 J9.16 J9.17 J9.18 J9.19 J9.20 J9.21 J9.22 J9.23 J9.24 J9.25 J9.26 J9.27 J9.28 J9.29 J9.30 J9.31 J9.32 J9.33 J9.34 J9.35 J9.36 J9.37 J9.38 J9.39 J9.40 J9.41 J9.42 J9.43 J9.44 J9.45 J9.46 J9.47 J9.48 J9.49 J9.50  red brown orange  red yellow orange brown black green  J31.1 J31.2 J31.3 J31.4 J31.5 J31.6  1 2 3 4 5 6  6600-0746-700  1 2 3 4 5 6 7 8  6600-0784-700  J30.1 J30.2 J30.3 J30.4 J30.5 J30.6  1 2 3 4  shield  black brown green orange yellow red  J10.1 J10.2 J10.3 J10.4 J10.5 J10.6  1 2 3 4 5 6  1 2 3 4 5  J35.1 J35.2 J35.3 J35.4 J35.5 J35.6 J35.7 J35.8  red brown black black red brown  RT1 1  black  2 1  DOWN  East Hood Hand Control  1 2 3 4 5  J37.1 J37.2 J37.3 J37.4 J37.5 J37.6 J37.7 J37.8 J37.9 J37.10 J37.11 J37.12 J37.13 J37.14 J37.15 J37.16 J37.17 J37.18 J37.19 J37.20 J37.21 J37.22 J37.23 J37.24 J37.25 J37.26 J37.27 J37.28 J37.29 J37.30 J37.31 J37.32 J37.33 J37.34 J37.35 J37.36 J37.37 J37.38 J37.39 J37.40 J37.41 J37.42 J37.43 J37.44 J37.45 J37.46 J37.47 J37.48 J37.49 J37.50  6600-0744-700  Card Cage  UP  6600-0736-701  1 2 3 4 5  orange yellow blue black  5 lemoenv  6600-0783-700  brown black orange red green yellow blue  1 2 3 4 5 6 7  4  6600-1531-700  2 1  shield  1 2 3 4 5  6600-0706-700  1 2 3 4 5 6  DOWN  green  6  6600-0736-702 West Hood Hand Control  6600-0717-700  Environmental Connector viewed from wire termination side of panel connector  2 3  6  6600-1530-700 J7.1 J7.2 J7.3 J7.4 J7.5 J7.6 J7.7  1  8 7  6600-0703-700 red brown  1 2 3 4 5 6 7 8  EL DISPLAY 6600-1025-600  3  UP  6600-0822-700  P G N  SCALE  Configuration Plug Group 2  6600-0739-700  5  230V  1 2 3 4 5 6 7 8  Scale Connector viewed from wire termination side of panel connector  2 4  115V  1 2 3 4 5 6 7 8  4  P G N  1 2 3 4 5 6  Yellow color wires  1 2 3 4 5 6  Orange color wires  5  Systems with Panel Connector on Environmental Sensor  green red blue orange  J23.4 J23.3 J23.2 J23.1  TP2.1 + 5 V TP2.2 AUDIO_FREQ TP2.3 + 5 V STBY TP2.4 GND (D)  3  6  TP3.3 Diplay Brightness B  GRAPHICS DRIVER 6600-0723-700  1  2  7  6600-0749-702  6600-0749-701  1  J26.1 J26.2 J26.3 J26.4 J26.5 J26.6  1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20  J27.1 J27.2 J27.3 J27.4 J27.5 J27.6 J27.7 J27.8 J27.9 J27.10 J27.11 J27.12 J27.13 J27.14 J27.15 J27.16 J27.17 J27.18 J27.19 J27.20  +vhall S1 S2 S3 -vhall  8  red yellow orange white brown black  J60.1 J60.2 J60.3 J60.4 J60.5 J60.6  LED DISPLAY TP3.1 Display Brightness A TP3.2 LED Voltage 6600-0735-700  D  J24.1 J24.2 J24.3 J24.4 J24.5 J24.6  P G N  6600-1007-600  1 2 3 4 5 6  J25.1 J25.2 J25.3 J25.4  1 2 3 4 5 6  5 6 7 8 9 10  TP1.1 1.2 V ind TP1.2 1.2 V TP1.3 V thref TP1.4 - 5 VAN TP1.5 + 5 VAN TP1.6 GND (A)  230V  1 2 3  TOUCH PANEL 4  J20.1 J20.2 J20.3 J20.4 J20.5 J20.6 J20.7 J20.8 J20.9 J20.10 J20.11 J20.12 J20.13 J20.14  115V  WIRING DIAGRAM FOR GIRAFFE OMNIBED  1  6600-0725-700  J8.1 J8.2 J8.3 J8.4 J8.5 J8.6 J8.7 J8.8 J8.9 J8.10 J8.11 J8.12 J8.13 J8.14  1 2 3 4 5 6  6600-0748-702 Yellow color wires  1 2 3 4 5 6  6600-0748-701 Orange color wires  2  ROTARY ENCODER 6600-1026-600  J22.1 J22.2  5  6600-2323-100  FRACTIONS  COPYRIGHT 2000 BY OHMEDA MEDICAL THIS DOCUMENT CONTAINS CONFIDENTIA L OR PROPRIETARY INFORMATI ON OF OHMEDA MEDICAL. NEITHER THIS DOCUMENT NOR THE INFOR MATION THERIN IS TO BE REPRODUCED, DISTRIBUTED, USED OR DISCLOSED EITHER IN WHOLE OR IN PART, EXCEPT AS SPECIFICALLY AUTHORIZED BY O HMEDA MEDICAL. 2  + -  DECIMALS  + .XX - -+ -.XXX + -.XXXX -  APPROVALS  AHR  OHMEDA MEDICAL  6/6/00  LAUREL, MD 20723  CHECKED  STR  WIRING DIAGRAM,  6/12/00  ENGINEERING  SMF CAD  DO NOT SCALE DRAWING SURFACE ROUGHNESS  DATE  DRAWN  RECORDS  6/11/00 Size  GIRAFFE OMNIBED AND INCUBATOR DRAWING NUMBER  D PROJECT  6600-2323-100 Sheet  SCALE  ICP011 1  NONE  of  1  3
File Type: PDF
File Size: 217 KB
File Name: giraffe_omnibed_and_incubator_wiring_diagram.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions