Service Manual
494 Pages
Preview
Page 1
P R E L I M I N A R Y
(MAY 21, 2013) COVER.FM
GE Healthcare
LOGIQ S8 Service Manual
Document Number: 5394227 Revision: 4
GE HEALTHCARE DIRECTION 5394227, 4
LOGIQ™ S8 SERVICE MANUAL
Important Precautions TRANSLATION POLICY
WARNING (EN)
AVERTISSEMENT (FR)
WARNUNG (DE)
THIS SERVICE MANUAL IS AVAILABLE IN ENGLISH ONLY. • IF A CUSTOMER’S SERVICE PROVIDER REQUIRES A LANGUAGE OTHER THAN ENGLISH, IT IS THE CUSTOMER’S RESPONSIBILITY TO PROVIDE TRANSLATION SERVICES. • DO NOT ATTEMPT TO SERVICE THE EQUIPMENT UNLESS THIS SERVICE MANUAL HAS BEEN CONSULTED AND IS UNDERSTOOD. • FAILURE TO HEED THIS WARNING MAY RESULT IN INJURY TO THE SERVICE PROVIDER, OPERATOR OR PATIENT FROM ELECTRIC SHOCK, MECHANICAL OR OTHER HAZARDS. CE MANUEL DE MAINTENANCE N’EST DISPONIBLE QU’EN ANGLAIS. • SI LE TECHNICIEN DU CLIENT A BESOIN DE CE MANUEL DANS UNE AUTRE LANGUE QUE L’ANGLAIS, C’EST AU CLIENT QU’IL INCOMBE DE LE FAIRE TRADUIRE. • NE PAS TENTER D’INTERVENTION SUR LES é QUIPEMENTS TANT QUE LE MANUEL SERVICE N’A PAS é Té CONSULTé ET COMPRIS. • LE NON-RESPECT DE CET AVERTISSEMENT PEUT ENTRAîNER CHEZ LE TECHNICIEN, L’OPé RATEUR OU LE PATIENT DES BLESSURES DUES à DES DANGERS é LECTRIQUES, Mé CANIQUES OU AUTRES. DIESES KUNDENDIENST-HANDBUCH EXISTIERT NUR IN ENGLISCHER SPRACHE. • FALLS EIN FREMDER KUNDENDIENST EINE ANDERE SPRACHE BENö TIGT, IST ES AUFGABE DES KUNDEN Fü R EINE ENTSPRECHENDE ÜBERSETZUNG ZU SORGEN. • VERSUCHEN SIE NICHT, DAS GERä T ZU REPARIEREN, BEVOR DIESES KUNDENDIENST-HANDBUCH NICHT ZU RATE GEZOGEN UND VERSTANDEN WURDE. • WIRD DIESE WARNUNG NICHT BEACHTET, SO KANN ES ZU VERLETZUNGEN DES KUNDENDIENSTTECHNIKERS, DES BEDIENERS ODER DES PATIENTEN DURCH ELEKTRISCHE SCHLä GE, MECHANISCHE ODER SONSTIGE GEFAHREN KOMMEN.
-
i
GE HEALTHCARE DIRECTION 5394227, 4
HOIATUS (ET)
LOGIQ™ S8 SERVICE MANUAL
KÄESOLEV TEENINDUSJUHEND ON SAADAVAL AINULT INGLISE KEELES. • KUI KLIENDITEENINDUSE OSUTAJA Nõ UAB JUHENDIT INGLISE KEELEST ERINEVAS KEELES, VASTUTAB KLIENT Tõ LKETEENUSE OSUTAMISE EEST. • ä RGE ü RITAGE SEADMEID TEENINDADA ENNE EELNEVALT Kä ESOLEVA TEENINDUSJUHENDIGA TUTVUMIST JA SELLEST ARU SAAMIST. • Kä ESOLEVA HOIATUSE EIRAMINE Võ IB Põ HJUSTADA TEENUSEOSUTAJA, OPERAATORI Võ I PATSIENDI VIGASTAMIST ELEKTRILö ö GI, MEHAANILISE Võ I MUU OHU TAGAJä RJEL.
(FI)
TÄMÄ HUOLTO-OHJE ON SAATAVILLA VAIN ENGLANNIKSI. • JOS ASIAKKAAN PALVELUNTARJOAJA VAATII MUUTA KUIN ENGLANNINKIELISTä MATERIAALIA, TARVITTAVAN Kä ä NNö KSEN HANKKIMINEN ON ASIAKKAAN VASTUULLA. • ä Lä YRITä KORJATA LAITTEISTOA ENNEN KUIN OLET VARMASTI LUKENUT JA YMMä RTä NYT Tä Mä N HUOLTO-OHJEEN. • MIKä LI Tä Tä VAROITUSTA EI NOUDATETA, SEURAUKSENA VOI OLLA PALVELUNTARJOAJAN, LAITTEISTON Kä YTTä Jä N TAI POTILAAN VAHINGOITTUMINEN Sä HKö ISKUN, MEKAANISEN VIAN TAI MUUN VAARATILANTEEN VUOKSI.
ΠΡΟΕΙΔΟΠΟΙΗΣΗ
ΤΟ ΠΑΡΟΝ ΕΓΧΕΙΡΙΔΙΟ ΣΕΡΒΙΣ ΔΙΑΤΙΘΕΤΑΙ ΣΤΑ ΑΓΓΛΙΚΑ ΜΟΝΟ. • ΕΑΝ ΤΟ ΑΤΟΜΟ ΠΑΡΟΧΗΣ ΣΕΡΒΙΣ ΕΝΟΣ ΠΕΛΑΤΗ ΑΠΑΙΤΕΙ ΤΟ ΠΑΡΟΝ ΕΓΧΕΙΡΙΔΙΟ ΣΕ ΓΛΩΣΣΑ ΕΚΤΟΣ ΤΩΝ ΑΓΓΛΙΚΩΝ, ΑΠΟΤΕΛΕΙ ΕΥΘΥΝΗ ΤΟΥ ΠΕΛΑΤΗ ΝΑ ΠΑΡΕΧΕΙ ΥΠΗΡΕΣΙΕΣ ΜΕΤΑΦΡΑΣΗΣ. • ΜΗΝ ΕΠΙΧΕΙΡΗΣΕΤΕ ΤΗΝ ΕΚΤΕΛΕΣΗ ΕΡΓΑΣΙΩΝ ΣΕΡΒΙΣ ΣΤΟΝ ΕΞΟΠΛΙΣΜΟ ΕΚΤΟΣ ΕΑΝ ΕΧΕΤΕ ΣΥΜΒΟΥΛΕΥΤΕΙ ΚΑΙ ΕΧΕΤΕ ΚΑΤΑΝΟΗΣΕΙ ΤΟ ΠΑΡΟΝ ΕΓΧΕΙΡΙΔΙΟ ΣΕΡΒΙΣ. • ΕΑΝ ΔΕ ΛΑΒΕΤΕ ΥΠΟΨΗ ΤΗΝ ΠΡΟΕΙΔΟΠΟΙΗΣΗ ΑΥΤΗ, ΕΝΔΕΧΕΤΑΙ ΝΑ ΠΡΟΚΛΗΘΕΙ ΤΡΑΥΜΑΤΙΣΜΟΣ ΣΤΟ ΑΤΟΜΟ ΠΑΡΟΧΗΣ ΣΕΡΒΙΣ, ΣΤΟ ΧΕΙΡΙΣΤΗ Ή ΣΤΟΝ ΑΣΘΕΝΗ ΑΠΟ ΗΛΕΚΤΡΟΠΛΗΞΙΑ, ΜΗΧΑΝΙΚΟΥΣ Ή ΑΛΛΟΥΣ ΚΙΝΔΥΝΟΥΣ.
VAROITUS
(EL)
FIGYELMEZTETÉS (HU)
EZEN KARBANTARTÁSI KÉZIKÖNYV KIZÁRÓLAG ANGOL NYELVEN ÉRHETŐ EL. • HA A VEVŐ SZOLGÁLTATÓJA ANGOLTÓL ELTÉRŐ NYELVRE TART IGÉNYT, AKKOR A VEVŐ FELELŐSSÉGE A FORDÍTÁS ELKÉSZÍTTETÉSE. • NE PRÓBÁLJA ELKEZDENI HASZNÁLNI A BERENDEZÉST, AMÍG A KARBANTARTÁSI KÉZIKÖNYVBEN LEÍRTAKAT NEM ÉRTELMEZTÉK. • EZEN FIGYELMEZTETÉS FIGYELMEN KÍVÜL HAGYÁSA A SZOLGÁLTATÓ, MŰKÖDTETŐ VAGY A BETEG ÁRAMÜTÉS, MECHANIKAI VAGY EGYÉB VESZÉLYHELYZET MIATTI SÉRÜLÉSÉT EREDMÉNYEZHETI.
-
iii
GE HEALTHCARE DIRECTION 5394227, 4
LOGIQ™ S8 SERVICE MANUAL
BRĪDINĀJUMS (LV)
šĪ APKALPES ROKASGRĀMATA IR PIEEJAMA TIKAI ANGĻU VALODĀ. • JA KLIENTA APKALPES SNIEDZĒJAM NEPIECIEŠAMA INFORMĀCIJA CITĀ VALODĀ, NEVIS ANGĻU, KLIENTA PIENĀKUMS IR NODROŠINĀT TULKOŠANU. • NEVEICIET APRĪKOJUMA APKALPI BEZ APKALPES ROKASGRĀMATAS IZLASĪŠANAS UN SAPRAŠANAS. • ŠĪ BRĪDINĀJUMA NEIEVĒROŠANA VAR RADĪT ELEKTRISKĀS STRĀVAS TRIECIENA, MEHĀNISKU VAI CITU RISKU IZRAISĪTU TRAUMU APKALPES SNIEDZĒJAM, OPERATORAM VAI PACIENTAM.
ĮSPĖJIMAS (LT)
ŠIS EKSPLOATAVIMO VADOVAS YRA IŠLEISTAS TIK ANGLŲ KALBA. • JEI KLIENTO PASLAUGŲ TEIKĖJUI REIKIA VADOVO KITA KALBA – NE ANGLŲ, VERTIMU PASIRŪPINTI TURI KLIENTAS. • NEMĖGINKITE ATLIKTI ĮRANGOS TECHNINĖS PRIEŽIŪROS DARBŲ, NEBENT VADOVAUTUMĖTĖS ŠIUO EKSPLOATAVIMO VADOVU IR JĮ SUPRASTUMĖTE • NEPAISANT ŠIO PERSPĖJIMO, PASLAUGŲ TEIKĖJAS, OPERATORIUS AR PACIENTAS GALI BŪTI SUŽEISTAS DĖL ELEKTROS SMŪGIO, MECHANINIŲ AR KITŲ PAVOJŲ.
ADVARSEL (NO)
DENNE SERVICEHÅNDBOKEN FINNES BARE PÅ ENGELSK. • HVIS KUNDENS SERVICELEVERANDØR TRENGER ET ANNET SPRÅK, ER DET KUNDENS ANSVAR Å SØRGE FOR OVERSETTELSE. • IKKE FORSØK Å REPARERE UTSTYRET UTEN AT DENNE SERVICEHÅNDBOKEN ER LEST OG FORSTÅTT. • MANGLENDE HENSYN TIL DENNE ADVARSELEN KAN FØRE TIL AT SERVICELEVERANDØREN, OPERATØREN ELLER PASIENTEN SKADES PÅ GRUNN AV ELEKTRISK STØT, MEKANISKE ELLER ANDRE FARER.
OSTRZEŻENIE (PL)
NINIEJSZY PODRĘCZNIK SERWISOWY DOSTĘPNY JEST JEDYNIE W JĘZYKU ANGIELSKIM. • JEś LI FIRMA ś WIADCZĄCA KLIENTOWI USłUGI SERWISOWE WYMAGA UDOSTę PNIENIA PODRę CZNIKA W Ję ZYKU INNYM NIŻ ANGIELSKI, OBOWIĄZEK ZAPEWNIENIA STOSOWNEGO TłUMACZENIA SPOCZYWA NA KLIENCIE. • NIE PRó BOWAć SERWISOWAć NINIEJSZEGO SPRZę TU BEZ UPRZEDNIEGO ZAPOZNANIA SIę Z PODRę CZNIKIEM SERWISOWYM. • NIEZASTOSOWANIE SIę DO TEGO OSTRZEŻENIA MOżE GROZIć OBRAŻENIAMI CIAłA SERWISANTA, OPERATORA LUB PACJENTA W WYNIKU PORAŻENIA PRĄDEM, URAZU MECHANICZNEGO LUB INNEGO RODZAJU ZAGROŻEń .
-
v
GE HEALTHCARE DIRECTION 5394227, 4
DİKKAT (TR)
LOGIQ™ S8 SERVICE MANUAL
BU SERVİS KILAVUZU YALNIZCA İNGİLİZCE OLARAK SAĞLANMIŞTIR. • EĞER MÜŞTERİ TEKNİSYENİ KILAVUZUN İNGİLİZCE DIŞINDAKİ BİR DİLDE OLMASINI İSTERSE, KILAVUZU TERCÜME ETTİRMEK MÜŞTERİNİN SORUMLULUĞUNDADIR. • SERVİS KILAVUZUNU OKUYUP ANLAMADAN EKİPMANLARA MÜDAHALE ETMEYİNİZ. • BU UYARININ GÖZ ARDI EDİLMESİ, ELEKTRİK ÇARPMASI YA DA MEKANİK VEYA DİĞER TÜRDEN KAZALAR SONUCUNDA TEKNİSYENİN, OPERATÖRÜN YA DA HASTANIN YARALANMASINA YOL AÇABİLİR.
(JA)
Traditional Chinese
viii
-
GE HEALTHCARE DIRECTION 5394227, 4
LOGIQ™ S8 SERVICE MANUAL
DAMAGE IN TRANSPORTATION All packages should be closely examined at time of delivery. If damage is apparent write “Damage In Shipment” on ALL copies of the freight or express bill BEFORE delivery is accepted or “signed for” by a GE representative or hospital receiving agent. Whether noted or concealed, damage MUST be reported to the carrier immediately upon discovery, or in any event, within 14 days after receipt, and the contents and containers held for inspection by the carrier. A transportation company will not pay a claim for damage if an inspection is not requested within this 14 day period.
CERTIFIED ELECTRICAL CONTRACTOR STATEMENT - FOR USA ONLY All electrical Installations that are preliminary to positioning of the equipment at the site prepared for the equipment shall be performed by licensed electrical contractors. Other connections between pieces of electrical equipment, calibrations and testing shall be performed by qualified GE Healthcare personnel. In performing all electrical work on these products, GE will use its own specially trained field engineers. All of GE’s electrical work on these products will comply with the requirements of the applicable electrical codes. The purchaser of GE equipment shall only utilize qualified personnel (i.e., GE’s field engineers, personnel of third-party service companies with equivalent training, or licensed electricians) to perform electrical servicing on the equipment.
OMISSIONS & ERRORS If there are any omissions, errors or suggestions for improving this documentation, please contact the GE Healthcare Global Documentation Group with specific information listing the system type, manual title, part number, revision number, page number and suggestion details. Mail the information to:Service Documentation, 9900 Innovation Drive (RP-2123), Wauwatosa, WI53226, USA. GE Healthcare employees should use TrackWise to report service documentation issues. These issues will then be in the internal problem reporting tool and communicated to the writer.
SERVICE SAFETY CONSIDERATIONS DANGER DANGEROUS VOLTAGES, CAPABLE OF CAUSING DEATH, ARE PRESENT IN
THIS EQUIPMENT. USE EXTREME CAUTION WHEN HANDLING, TESTING AND ADJUSTING. WARNING WARNING USE ALL PERSONAL PROTECTION EQUIPMENT (PPE) SUCH AS GLOVES, SAFETY
SHOES, SAFETY GLASSES, AND KNEELING PAD, TO REDUCE THE RISK OF INJURY. For a complete review of all safety requirements, see the Chapter 1, Safety Considerations section in the Service Manual.
x
-
GE HEALTHCARE DIRECTION 5394227, 4
LOGIQ™ S8 SERVICE MANUAL
LEGAL NOTES The contents of this publication may not be copied or duplicated in any form, in whole or in part, without prior written permission of GE Healthcare. GE Healthcare may revise this publication from time to time without written notice.
PROPRIETARY TO GE HEALTHCARE Permission to use this Advanced Service Software and related documentation (herein called the material) by persons other than GE Healthcare employees is provided only under an Advanced Service Package License relating specifically to this Proprietary Material. This is a different agreement from the one under which operating and basic service software is licensed. A license to use operating or basic service software does not extend to or cover this software or related documentation. If you are a GE Healthcare employee or a customer who has entered into such a license agreement with GE Healthcare to use this proprietary software, you are authorized to use this Material according to the conditions stated in your license agreement. However, you do not have the permission of GE Healthcare to alter, decompose or reverse-assemble the software, and unless you are a GE employee, you MAY NOT COPY the Material. The Material is protected by Copyright and Trade Secret laws; the violation of which can result in civil damages and criminal prosecution. If you are not party to such a license agreement or a GE Healthcare Employee, you must exit this Material now.
TRADEMARKS All products and their name brands are trademarks of their respective holders.
COPYRIGHTS All Material Copyright© 2011-2013 by General Electric Company Inc. All Rights Reserved.
-
xi
GE HEALTHCARE DIRECTION 5394227, 4
LOGIQ™ S8 SERVICE MANUAL
Revision History Revision
Date
Reason for change
1
Jun. 2011
Initial Release
2
Jul. 2011
Correction
3
Mar. 2012
Correction
4
May. 2013
Release for R2
List of Effected Pages (LOEP)
xii
Pages
Revision
Pages
Revision
Pages
Revision
Title Page
4
Chapter3
4
Chapter 8
4
Warnings i to xii
4
Chapter 4
4
Chapter 9
4
TOC
4
Chapter 5
4
Chapter 10
4
Chapter 1
4
Chapter 6
4
Back Cover
N/A
Chapter 2
4
Chapter 7
4
-
GE HEALTHCARE DIRECTION 5394227, 4
LOGIQ™ S8 SERVICE MANUAL
Table of Contents CHAPTER 1 Introduction Service manual overview...1 - 1 Contents in this section...1 - 1 Contents in this service manual...1 - 2 Typical users of the “Basic” Service Manual...1 - 2 LOGIQ™ S8 models covered by this manual...1 - 3 Product description...1 - 4 Contents in this sub-section...1 - 4 Overview of the LOGIQ™ S8 ultrasound scanner...1 - 4 History - Software versions...1 - 5 History - Peripherals/Accessories...1 - 5 FRUs for Back End Processor...1 - 5 History - Supported probes...1 - 5 How to turn the LOGIQ™ S8 ON and OFF...1 - 5 How to check for hardware/software version and installed options . .1 - 5 Purpose of the operator manual(s)...1 - 5 Important conventions...1 - 6 Contents in this section...1 - 6 Conventions used in this manual...1 - 6 Model designations...1 - 6 Icons...1 - 6 Safety precaution messages...1 - 6 Standard Hazard Icons...1 - 7 Product Icons...1 - 9 Safety Considerations...1 - 13 Contents in this section...1 - 13 Introduction...1 - 13 Human Safety...1 - 13 Mechanical Safety...1 - 16 Electrical Safety...1 - 18 Safe Practices...1 - 18 Probes...1 - 18 Auxiliary Devices Safety...1 - 19 Battery Safety...1 - 21 Labels Locations...1 - 22 Main Label...1 - 23 Table of Contents
1
GE HEALTHCARE DIRECTION 5394227, 4
PROPRIETARY TO GE LOGIQ™ S8 SERVICE MANUAL
Dangerous Procedure Warnings... 1 - 24 Lockout/Tagout (LOTO) Requirements... 1 - 25 Returning/Shipping System, Probes and Repair Parts... 1 - 26 Electromagnetic Compatibility (EMC)... 1 - 27 What is EMC?... 1 - 27 Compliance... 1 - 27 Electrostatic Discharge (ESD) Prevention... 1 - 27 Customer Assistance... 1 - 28 Contact Information... 1 - 28 System Manufacturer... 1 - 29 Authorized EU Representative... 1 - 29
-
2
GE HEALTHCARE DIRECTION 5394227, 4
PROPRIETARY TO GE LOGIQ™ S8 SERVICE MANUAL
CHAPTER 2 Site preparations General console requirements... 2 - 1 Contents in this section... 2 - 1 Environmental Requirements... 2 - 1 If the unit is very cold or hot... 2 - 1 Cooling... 2 - 1 Lighting... 2 - 1 Electrical Requirements... 2 - 2 General requirements... 2 - 2 Electrical requirements for LOGIQ™ S8... 2 - 2 Inrush Current... 2 - 2 Site Circuit Breaker... 2 - 2 Site Power Outlets... 2 - 2 Unit Power Plug... 2 - 2 EMI Limitations... 2 - 3 Probe Environmental Requirements... 2 - 5 Time and Manpower Requirements... 2 - 5 Facility needs... 2 - 6 Contents in this section... 2 - 6 Purchaser Responsibilities... 2 - 7 Required Facility Needs... 2 - 8 Desirable features... 2 - 9 Minimal floor plan suggestions... 2 - 9 Networking setup requirements... 2 - 10 Stand alone scanner (without network connection)... 2 - 10 Scanner connected to hospital’s network... 2 - 10 InSite Requirements... 2 - 10 Purpose of the DICOM network function... 2 - 10 DICOM Option Pre-installation Requirements... 2 - 10
-
3
GE HEALTHCARE DIRECTION 5394227, 4
PROPRIETARY TO GE LOGIQ™ S8 SERVICE MANUAL
CHAPTER 3 System Setup Setup reminders... 3 - 1 Contents in this section... 3 - 1 Average Setup Time... 3 - 1 Setup warnings... 3 - 2 Installation Warnings... 3 - 3 Moving/Lifting the System... 3 - 3 System Acclimation Time... 3 - 4 Operator Control panel Position... 3 - 4 Brake Pedal Operation... 3 - 4 Receiving and unpacking the equipment... 3 - 5 Purpose of this section... 3 - 5 Contents in this section... 3 - 5 Receiving and unpacking warnings... 3 - 5 Receiving the LOGIQ™ S8... 3 - 6 Overview... 3 - 6 Examine package... 3 - 6 Damage in transportation... 3 - 6 The Tilt & Shock indicators... 3 - 7 Overview... 3 - 7 Position of the Tilt & Shock indicators... 3 - 7 LOGIQ™ S8 Transportation Box Label... 3 - 7 Environmental Label... 3 - 8 Unpacking the LOGIQ™ S8... 3 - 9 Packing materials - recycling information... 3 - 11 Preparing for setup... 3 - 12 Verify Customer Order... 3 - 12 Physical inspection... 3 - 12 EMI Protection... 3 - 13 Completing the Set Up... 3 - 14 Purpose of this section... 3 - 14 Contents in this section... 3 - 14 System Specifications... 3 - 15 System requirements verification... 3 - 15 Physical Dimensions of LOGIQ™ S8... 3 - 15 Acoustic Noise Output... 3 - 15 Electrical specifications... 3 - 15 Verification of the system’s voltage setting... 3 - 15 -
4
GE HEALTHCARE DIRECTION 5394227, 4
PROPRIETARY TO GE LOGIQ™ S8 SERVICE MANUAL
Electrical Specifications... 3 - 15 Power On/Boot Up... 3 - 16 Warnings... 3 - 16 Connect AC (mains) Power to the LOGIQ™ S8... 3 - 17 Switch ON the AC Power to LOGIQ™ S8... 3 - 18 Power Shutdown... 3 - 19 Complete power down... 3 - 20 Connecting Probes... 3 - 21 Introduction... 3 - 21 Connect a probe... 3 - 21 Connecting the CW Pencil Probe... 3 - 21 Connecting the TEE Probe... 3 - 22 Cable Handling... 3 - 22 Activating the Probe... 3 - 23 Deactivating the Probe... 3 - 23 Disconnecting the Probe... 3 - 23 Disconnecting the TEE Probe... 3 - 23 External I/O Connectors... 3 - 24 Connect USB Flash Drive... 3 - 25 ECG connector... 3 - 25 System Configuration... 3 - 26 Purpose of this section... 3 - 26 Contents in this section... 3 - 26 Select System/General preset menu... 3 - 26 Available probes... 3 - 28 Software Option installation... 3 - 29 Installing a Software Option... 3 - 29 Optional Peripherals/Peripheral Connection... 3 - 30 Contents in this section... 3 - 30 Connecting the Secondary “Patient” LCD Monitor... 3 - 31 WIthout UVC... 3 - 32 WIth Off-board UVC... 3 - 33 WIth On-board UVC... 3 - 34 Connecting the Off-Board/On-Board UVC... 3 - 35 Connecting the Off-Board UVC... 3 - 35 Connecting the On-Board UVC... 3 - 36 UVC functional check Procedure... 3 - 37 Connecting the Footswitch... 3 - 38 Connecting the USB Flash Drive and USB External Hard disk drive... 3 - 39 General Remarks and Hints when using external USB-Devices . . . 3 - 39 External USB-Devices - Connection... 3 - 39 External USB-Devices - Disconnection... 3 - 39 -
5
GE HEALTHCARE DIRECTION 5394227, 4
PROPRIETARY TO GE LOGIQ™ S8 SERVICE MANUAL
Printer Installation... 3 - 40 Contents in this section... 3 - 40 Installing Digital Black & White Printer Sony UP-D897... 3 - 40 Connection Scheme: Black & White Printer... 3 - 41 Installing Digital Color Printer Sony UP-D25MD... 3 - 42 Connection Scheme: Color Printer... 3 - 43 Adding the printer to the system... 3 - 44 Adjustment of Printer Settings... 3 - 44 UP-D897 - Printer Settings... 3 - 45 UP-D25MD - Printer Settings... 3 - 46 Setting the printer to print reports... 3 - 48 Connectivity Setup... 3 - 49 Contents in this section... 3 - 49 Connectivity Introduction... 3 - 49 The Dataflow Concept... 3 - 49 Dataflow Examples... 3 - 50 Stand-alone LOGIQ™ S8... 3 - 51 LOGIQ™ + PC within a “Sneaker Net”... 3 - 51 Connection between LOGIQ™ and DICOM Server... 3 - 51 Wired Ethernet from LOGIQ™ S8 to a Workstation... 3 - 52 Direct Cable Connection from the LOGIQ™ S8 to a Workstation via a Crossover Cable... 3 - 52 Connection via a Peer-to-Peer Network... 3 - 52 Connection via Hospital Network... 3 - 52 Connection using Wireless Option (R2.x.x or later)... 3 - 52 Configuring Connectivity... 3 - 53 Overview... 3 - 53 Contents in this section... 3 - 53 Structured Reporting... 3 - 53 Supported parameters... 3 - 53 Connectivity Functions... 3 - 54 TCPIP... 3 - 54 Device... 3 - 56 Service... 3 - 57 Adding a service to a destination device... 3 - 57 Removing a service... 3 - 57 Changing parameters for a service... 3 - 58 Connectivity Setup Worksheet... 3 - 59 Paperwork... 3 - 61 Product Locator Installation Card... 3 - 61 -
6
GE HEALTHCARE DIRECTION 5394227, 4
PROPRIETARY TO GE LOGIQ™ S8 SERVICE MANUAL
User Manual(s)... 3 - 61
-
7
GE HEALTHCARE DIRECTION 5394227, 4
PROPRIETARY TO GE LOGIQ™ S8 SERVICE MANUAL
CHAPTER 4 Functional Checks Required equipment... 4 - 1 General procedures... 4 - 2 Overview... 4 - 2 Contents in this section... 4 - 2 System Exterior Visual Check... 4 - 3 Physical Abnormalities... 4 - 3 Appearance Inspection... 4 - 4 Mechanical Parts Functional Check... 4 - 5 Main LCD... 4 - 6 LCD ARM... 4 - 7 Swivel Lock of the operator panel... 4 - 8 Swivel/Brake Lock Caster... 4 - 9 Swivel/Brake Lock Caster... 4 - 10 Power On/Off... 4 - 11 Warnings ... 4 - 11 Connect AC (mains) Power to the LOGIQ™ S8... 4 - 12 Switch ON the AC Power to LOGIQ™ S8... 4 - 13 Sleep Mode Check... 4 - 14 Power Shutdown... 4 - 15 Complete power down... 4 - 16 USB Port Test... 4 - 18 Service Key (Dongle, HASP)... 4 - 19 Exit to Windows Desktop from the LOGIQ™ S8 Application Software... 4 - 21 Removable Media... 4 - 22 Archiving and Loading Presets... 4 - 22 Loading Presets from removable media... 4 - 22 Backup... 4 - 22 Installation and Setup Procedures for Peripherals... 4 - 22 Moving and Transporting the LOGIQ™ S8... 4 - 23 Before moving the system... 4 - 23 Moving the system... 4 - 25 Transporting the System... 4 - 26 Setting up at a new location... 4 - 27 Recording important settings and parameters... 4 - 28 Overview... 4 - 28 Connectivity - Recording the TCP/IP settings... 4 - 29 Connectivity - WLAN... 4 - 30 Connectivity - Recording the AE Title and Port settings... 4 - 31 Connectivity - Recording Device Destination settings... 4 - 32 Connectivity - Recording Dataflow settings... 4 - 33 Connectivity - Recording the Print Key Assignments... 4 - 34 -
8
GE HEALTHCARE DIRECTION 5394227, 4
PROPRIETARY TO GE LOGIQ™ S8 SERVICE MANUAL
Connectivity - Recording other settings for Print... 4 - 35 Connectivity - Service settings... 4 - 36 Connectivity - Recording Miscellaneous settings... 4 - 37 Admin - Recording the Software Option Keys... 4 - 39 Admin - Users... 4 - 40 System - Data Store Management... 4 - 41 System - Recording Peripheral settings... 4 - 42 System - User Configurable Key... 4 - 43 System - Recording software version and system information... 4 - 45 Location, Region and Language... 4 - 46 System - Recording System Imaging Settings... 4 - 47 System - Recording System Measure settings... 4 - 48 Application - Recording Print Controls settings... 4 - 50 Functional Checks... 4 - 52 Overview... 4 - 52 Contents in this section... 4 - 52 Preparation... 4 - 52 Basic Controls... 4 - 53 Trackball Area... 4 - 53 Other Controls... 4 - 53 Performance Tests... 4 - 54 Recommended Test Phantoms (optional)... 4 - 54 B-Mode Checks... 4 - 55 Introduction... 4 - 55 Preparations... 4 - 56 Checks... 4 - 56 M-Mode Checks... 4 - 57 Preparations... 4 - 57 Checks... 4 - 58 Color Flow Mode Checks... 4 - 59 Introduction... 4 - 59 Preparations... 4 - 59 Select Color B-Mode... 4 - 59 Select Color M-Mode... 4 - 60 Checks... 4 - 60 PW/CW Doppler Mode Checks... 4 - 61 Preparations... 4 - 61 Adjust the PW/CW Doppler Mode controls... 4 - 62 Tissue Velocity Imaging (TVI) Checks... 4 - 63 Introduction... 4 - 63 Preparations... 4 - 63 Adjust the TVI Controls... 4 - 64 Cineloop Check... 4 - 65 Introduction... 4 - 65 Preparation... 4 - 65 -
9
GE HEALTHCARE DIRECTION 5394227, 4
PROPRIETARY TO GE LOGIQ™ S8 SERVICE MANUAL
Checks... 4 - 65 Basic Measurements... 4 - 66 Check Distance and Tissue Depth Measurement... 4 - 66 Check Circumference/Area (Ellipse) Measurement... 4 - 66 Worksheets... 4 - 67 Report Pages... 4 - 67 System Integration Checks... 4 - 68 Operator panel Test... 4 - 68 DVD Drive Test... 4 - 69 LAN Port Test... 4 - 69 Probe/Connectors Checks... 4 - 70 To Connect a Probe... 4 - 70 TEE RS-DLP adapter + TEE probe... 4 - 70 ECG Check... 4 - 71 Introduction... 4 - 71 Parts needed... 4 - 71 Preparations... 4 - 71 ECG Checks... 4 - 71 Peripheral Checks... 4 - 73 DVR Test (if equipped)... 4 - 73 Black and White Printer Test... 4 - 73 Color Printer Test... 4 - 73 CD/DVD Read/Write Test... 4 - 73 ECG Test... 4 - 73 Wireless LAN Test... 4 - 74 Volume Navigation Test... 4 - 74 Test... 4 - 74 Single CWD... 4 - 74 Application Turnover Check List... 4 - 75 Software Configuration Checks... 4 - 75 Power supply adjustments... 4 - 75 Power Supply Adjustment... 4 - 75 3D/4D and Volume Navigation Functional Check... 4 - 75 Site Log... 4 - 76
-
10
GE HEALTHCARE DIRECTION 5394227, 4
PROPRIETARY TO GE LOGIQ™ S8 SERVICE MANUAL
CHAPTER 5 Components and Functions (Theory) General Information... 5 - 1 Contents in this section... 5 - 1 System Exterior... 5 - 2 Operator Panel... 5 - 3 System Options... 5 - 5 System Ports... 5 - 6 Front USB... 5 - 7 Rear USB... 5 - 7 HDMI... 5 - 8 RJ45... 5 - 9 MiniJack... 5 - 9 AC Inlet... 5 - 9 Power Distribution... 5 - 10 Purpose of this section... 5 - 10 Power Up Sequence Description... 5 - 10 Power Loss description... 5 - 11 Software Options... 5 - 12 Hardware Options... 5 - 15 Regional and Peripheral Options... 5 - 17 Regional Options... 5 - 17 Peripheral Options... 5 - 17 Mechanical Descriptions... 5 - 18 Contents in this section... 5 - 18 Physical Dimensions... 5 - 18 LCD Monitor... 5 - 18 Operator panel positioning... 5 - 19 Air Flow Distribution... 5 - 20
-
11
GE HEALTHCARE DIRECTION 5394227, 4
PROPRIETARY TO GE LOGIQ™ S8 SERVICE MANUAL
CHAPTER 6 Service Adjustments Regulatory... 6 - 1 LCD Monitor Adjustment... 6 - 2 Brightness/Contrast... 6 - 3 Brightness... 6 - 3 Contrast... 6 - 4 Gamma... 6 - 4 Mode... 6 - 4 Function... 6 - 5 Scale... 6 - 5 Information... 6 - 5 Memory Recall... 6 - 6 SBC... 6 - 6 OSD... 6 - 7 Language... 6 - 7 H-Position... 6 - 7 V-Position... 6 - 7 Half Tone... 6 - 8 Exit... 6 - 8 Volume Navigation Calibration Procedure... 6 - 9 Purpose of this section... 6 - 9 Contents in this section... 6 - 9 Overview... 6 - 9 Equipment... 6 - 9 Setup... 6 - 10 Measure Initial Accuracy... 6 - 11 Perform Calibration... 6 - 12
-
12