Service Manual
802 Pages
Preview
Page 1
GE Healthcare
VIVID E9 Service Manual
OPERATING DOCUMENTATION
Part Number: GA091568 Revision: 5
GE HEALTHCARE DIRECTION GA091568, REVISION 5
VIVID E9 SERVICE MANUAL
Important Precautions TRANSLATION POLICY
WARNING (EN)
AVERTISSEMENT (FR)
WARNUNG (DE)
THIS SERVICE MANUAL IS AVAILABLE IN ENGLISH ONLY. • IF A CUSTOMER’S SERVICE PROVIDER REQUIRES A LANGUAGE OTHER THAN ENGLISH, IT IS THE CUSTOMER’S RESPONSIBILITY TO PROVIDE TRANSLATION SERVICES. • DO NOT ATTEMPT TO SERVICE THE EQUIPMENT UNLESS THIS SERVICE MANUAL HAS BEEN CONSULTED AND IS UNDERSTOOD. • FAILURE TO HEED THIS WARNING MAY RESULT IN INJURY TO THE SERVICE PROVIDER, OPERATOR OR PATIENT FROM ELECTRIC SHOCK, MECHANICAL OR OTHER HAZARDS. CE MANUEL DE MAINTENANCE N’EST DISPONIBLE QU’EN ANGLAIS. • SI LE TECHNICIEN DU CLIENT A BESOIN DE CE MANUEL DANS UNE AUTRE LANGUE QUE L’ANGLAIS, C’EST AU CLIENT QU’IL INCOMBE DE LE FAIRE TRADUIRE. • NE PAS TENTER D’INTERVENTION SUR LES ÉQUIPEMENTS TANT QUE LE MANUEL SERVICE N’A PAS ÉTÉ CONSULTÉ ET COMPRIS. • LE NON-RESPECT DE CET AVERTISSEMENT PEUT ENTRAÎNER CHEZ LE TECHNICIEN, L’OPÉRATEUR OU LE PATIENT DES BLESSURES DUES À DES DANGERS ÉLECTRIQUES, MÉCANIQUES OU AUTRES. DIESES KUNDENDIENST-HANDBUCH EXISTIERT NUR IN ENGLISCHER SPRACHE. • FALLS EIN FREMDER KUNDENDIENST EINE ANDERE SPRACHE BENÖTIGT, IST ES AUFGABE DES KUNDEN FÜR EINE ENTSPRECHENDE ÜBERSETZUNG ZU SORGEN. • VERSUCHEN SIE NICHT, DAS GERÄT ZU REPARIEREN, BEVOR DIESES KUNDENDIENST-HANDBUCH NICHT ZU RATE GEZOGEN UND VERSTANDEN WURDE. • WIRD DIESE WARNUNG NICHT BEACHTET, SO KANN ES ZU VERLETZUNGEN DES KUNDENDIENSTTECHNIKERS, DES BEDIENERS ODER DES PATIENTEN DURCH ELEKTRISCHE SCHLÄGE, MECHANISCHE ODER SONSTIGE GEFAHREN KOMMEN.
-
i
GE HEALTHCARE DIRECTION GA091568, REVISION 5
HOIATUS (ET)
VIVID E9 SERVICE MANUAL
KÄESOLEV TEENINDUSJUHEND ON SAADAVAL AINULT INGLISE KEELES. • KUI KLIENDITEENINDUSE OSUTAJA NÕUAB JUHENDIT INGLISE KEELEST ERINEVAS KEELES, VASTUTAB KLIENT TÕLKETEENUSE OSUTAMISE EEST. • ÄRGE ÜRITAGE SEADMEID TEENINDADA ENNE EELNEVALT KÄESOLEVA TEENINDUSJUHENDIGA TUTVUMIST JA SELLEST ARU SAAMIST. • KÄESOLEVA HOIATUSE EIRAMINE VÕIB PÕHJUSTADA TEENUSEOSUTAJA, OPERAATORI VÕI PATSIENDI VIGASTAMIST ELEKTRILÖÖGI, MEHAANILISE VÕI MUU OHU TAGAJÄRJEL.
(FI)
TÄMÄ HUOLTO-OHJE ON SAATAVILLA VAIN ENGLANNIKSI. • JOS ASIAKKAAN PALVELUNTARJOAJA VAATII MUUTA KUIN ENGLANNINKIELISTÄ MATERIAALIA, TARVITTAVAN KÄÄNNÖKSEN HANKKIMINEN ON ASIAKKAAN VASTUULLA. • ÄLÄ YRITÄ KORJATA LAITTEISTOA ENNEN KUIN OLET VARMASTI LUKENUT JA YMMÄRTÄNYT TÄMÄN HUOLTO-OHJEEN. • MIKÄLI TÄTÄ VAROITUSTA EI NOUDATETA, SEURAUKSENA VOI OLLA PALVELUNTARJOAJAN, LAITTEISTON KÄYTTÄJÄN TAI POTILAAN VAHINGOITTUMINEN SÄHKÖISKUN, MEKAANISEN VIAN TAI MUUN VAARATILANTEEN VUOKSI.
ΠΡΟΕΙ∆ΟΠΟΙΗΣΗ
ΤΟ ΠΑΡΟΝ ΕΓΧΕΙΡΙ∆ΙΟ ΣΕΡΒΙΣ ∆ΙΑΤΙΘΕΤΑΙ ΣΤΑ ΑΓΓΛΙΚΑ ΜΟΝΟ. • ΕΑΝ ΤΟ ΑΤΟΜΟ ΠΑΡΟΧΗΣ ΣΕΡΒΙΣ ΕΝΟΣ ΠΕΛΑΤΗ ΑΠΑΙΤΕΙ ΤΟ ΠΑΡΟΝ ΕΓΧΕΙΡΙ∆ΙΟ ΣΕ ΓΛΩΣΣΑ ΕΚΤΟΣ ΤΩΝ ΑΓΓΛΙΚΩΝ, ΑΠΟΤΕΛΕΙ ΕΥΘΥΝΗ ΤΟΥ ΠΕΛΑΤΗ ΝΑ ΠΑΡΕΧΕΙ ΥΠΗΡΕΣΙΕΣ ΜΕΤΑΦΡΑΣΗΣ. • ΜΗΝ ΕΠΙΧΕΙΡΗΣΕΤΕ ΤΗΝ ΕΚΤΕΛΕΣΗ ΕΡΓΑΣΙΩΝ ΣΕΡΒΙΣ ΣΤΟΝ ΕΞΟΠΛΙΣΜΟ ΕΚΤΟΣ ΕΑΝ ΕΧΕΤΕ ΣΥΜΒΟΥΛΕΥΤΕΙ ΚΑΙ ΕΧΕΤΕ ΚΑΤΑΝΟΗΣΕΙ ΤΟ ΠΑΡΟΝ ΕΓΧΕΙΡΙ∆ΙΟ ΣΕΡΒΙΣ. • ΕΑΝ ∆Ε ΛΑΒΕΤΕ ΥΠΟΨΗ ΤΗΝ ΠΡΟΕΙ∆ΟΠΟΙΗΣΗ ΑΥΤΗ, ΕΝ∆ΕΧΕΤΑΙ ΝΑ ΠΡΟΚΛΗΘΕΙ ΤΡΑΥΜΑΤΙΣΜΟΣ ΣΤΟ ΑΤΟΜΟ ΠΑΡΟΧΗΣ ΣΕΡΒΙΣ, ΣΤΟ ΧΕΙΡΙΣΤΗ Ή ΣΤΟΝ ΑΣΘΕΝΗ ΑΠΟ ΗΛΕΚΤΡΟΠΛΗΞΙΑ, ΜΗΧΑΝΙΚΟΥΣ Ή ΑΛΛΟΥΣ ΚΙΝ∆ΥΝΟΥΣ.
VAROITUS
(EL)
FIGYELMEZTETÉS (HU)
EZEN KARBANTARTÁSI KÉZIKÖNYV KIZÁRÓLAG ANGOL NYELVEN ÉRHETŐ EL. • HA A VEVŐ SZOLGÁLTATÓJA ANGOLTÓL ELTÉRŐ NYELVRE TART IGÉNYT, AKKOR A VEVŐ FELELŐSSÉGE A FORDÍTÁS ELKÉSZÍTTETÉSE. • NE PRÓBÁLJA ELKEZDENI HASZNÁLNI A BERENDEZÉST, AMÍG A KARBANTARTÁSI KÉZIKÖNYVBEN LEÍRTAKAT NEM ÉRTELMEZTÉK. • EZEN FIGYELMEZTETÉS FIGYELMEN KÍVÜL HAGYÁSA A SZOLGÁLTATÓ, MŰKÖDTETŐ VAGY A BETEG ÁRAMÜTÉS, MECHANIKAI VAGY EGYÉB VESZÉLYHELYZET MIATTI SÉRÜLÉSÉT EREDMÉNYEZHETI.
-
iii
GE HEALTHCARE DIRECTION GA091568, REVISION 5
VIVID E9 SERVICE MANUAL
BRĪDINĀJUMS (LV)
ŠĪ APKALPES ROKASGRĀMATA IR PIEEJAMA TIKAI ANGĻU VALODĀ. • JA KLIENTA APKALPES SNIEDZĒJAM NEPIECIEŠAMA INFORMĀCIJA CITĀ VALODĀ, NEVIS ANGĻU, KLIENTA PIENĀKUMS IR NODROŠINĀT TULKOŠANU. • NEVEICIET APRĪKOJUMA APKALPI BEZ APKALPES ROKASGRĀMATAS IZLASĪŠANAS UN SAPRAŠANAS. • ŠĪ BRĪDINĀJUMA NEIEVĒROŠANA VAR RADĪT ELEKTRISKĀS STRĀVAS TRIECIENA, MEHĀNISKU VAI CITU RISKU IZRAISĪTU TRAUMU APKALPES SNIEDZĒJAM, OPERATORAM VAI PACIENTAM.
ĮSPĖJIMAS (LT)
ŠIS EKSPLOATAVIMO VADOVAS YRA IŠLEISTAS TIK ANGLŲ KALBA. • JEI KLIENTO PASLAUGŲ TEIKĖJUI REIKIA VADOVO KITA KALBA – NE ANGLŲ, VERTIMU PASIRŪPINTI TURI KLIENTAS. • NEMĖGINKITE ATLIKTI ĮRANGOS TECHNINĖS PRIEŽIŪROS DARBŲ, NEBENT VADOVAUTUMĖTĖS ŠIUO EKSPLOATAVIMO VADOVU IR JĮ SUPRASTUMĖTE • NEPAISANT ŠIO PERSPĖJIMO, PASLAUGŲ TEIKĖJAS, OPERATORIUS AR PACIENTAS GALI BŪTI SUŽEISTAS DĖL ELEKTROS SMŪGIO, MECHANINIŲ AR KITŲ PAVOJŲ.
ADVARSEL (NO)
DENNE SERVICEHÅNDBOKEN FINNES BARE PÅ ENGELSK. • HVIS KUNDENS SERVICELEVERANDØR TRENGER ET ANNET SPRÅK, ER DET KUNDENS ANSVAR Å SØRGE FOR OVERSETTELSE. • IKKE FORSØK Å REPARERE UTSTYRET UTEN AT DENNE SERVICEHÅNDBOKEN ER LEST OG FORSTÅTT. • MANGLENDE HENSYN TIL DENNE ADVARSELEN KAN FØRE TIL AT SERVICELEVERANDØREN, OPERATØREN ELLER PASIENTEN SKADES PÅ GRUNN AV ELEKTRISK STØT, MEKANISKE ELLER ANDRE FARER.
OSTRZEŻENIE (PL)
NINIEJSZY PODRĘCZNIK SERWISOWY DOSTĘPNY JEST JEDYNIE W JĘZYKU ANGIELSKIM. • JEŚLI FIRMA ŚWIADCZĄCA KLIENTOWI USłUGI SERWISOWE WYMAGA UDOSTĘPNIENIA PODRĘCZNIKA W JĘZYKU INNYM NIŻ ANGIELSKI, OBOWIĄZEK ZAPEWNIENIA STOSOWNEGO TłUMACZENIA SPOCZYWA NA KLIENCIE. • NIE PRÓBOWAĆ SERWISOWAĆ NINIEJSZEGO SPRZĘTU BEZ UPRZEDNIEGO ZAPOZNANIA SIĘ Z PODRĘCZNIKIEM SERWISOWYM. • NIEZASTOSOWANIE SIĘ DO TEGO OSTRZEŻENIA MOżE GROZIĆ OBRAŻENIAMI CIAłA SERWISANTA, OPERATORA LUB PACJENTA W WYNIKU PORAŻENIA PRĄDEM, URAZU MECHANICZNEGO LUB INNEGO RODZAJU ZAGROŻEŃ.
-
v
GE HEALTHCARE DIRECTION GA091568, REVISION 5
DİKKAT (TR)
VIVID E9 SERVICE MANUAL
BU SERVİS KILAVUZU YALNIZCA İNGİLİZCE OLARAK SAĞLANMIŞTIR. • EĞER MÜŞTERİ TEKNİSYENİ KILAVUZUN İNGİLİZCE DIŞINDAKİ BİR DİLDE OLMASINI İSTERSE, KILAVUZU TERCÜME ETTİRMEK MÜŞTERİNİN SORUMLULUĞUNDADIR. • SERVİS KILAVUZUNU OKUYUP ANLAMADAN EKİPMANLARA MÜDAHALE ETMEYİNİZ. • BU UYARININ GÖZ ARDI EDİLMESİ, ELEKTRİK ÇARPMASI YA DA MEKANİK VEYA DİĞER TÜRDEN KAZALAR SONUCUNDA TEKNİSYENİN, OPERATÖRÜN YA DA HASTANIN YARALANMASINA YOL AÇABİLİR.
(JA)
Traditional Chinese
viii
-
GE HEALTHCARE DIRECTION GA091568, REVISION 5
VIVID E9 SERVICE MANUAL
DAMAGE IN TRANSPORTATION All packages should be closely examined at time of delivery. If damage is apparent write “Damage In Shipment” on ALL copies of the freight or express bill BEFORE delivery is accepted or “signed for” by a GE representative or hospital receiving agent. Whether noted or concealed, damage MUST be reported to the carrier immediately upon discovery, or in any event, within 14 days after receipt, and the contents and containers held for inspection by the carrier. A transportation company will not pay a claim for damage if an inspection is not requested within this 14 day period.
CERTIFIED ELECTRICAL CONTRACTOR STATEMENT - FOR USA ONLY All electrical Installations that are preliminary to positioning of the equipment at the site prepared for the equipment shall be performed by licensed electrical contractors. Other connections between pieces of electrical equipment, calibrations and testing shall be performed by qualified GE Healthcare personnel. In performing all electrical work on these products, GE will use its own specially trained field engineers. All of GE’s electrical work on these products will comply with the requirements of the applicable electrical codes. The purchaser of GE equipment shall only utilize qualified personnel (i.e., GE’s field engineers, personnel of third-party service companies with equivalent training, or licensed electricians) to perform electrical servicing on the equipment.
OMISSIONS & ERRORS If there are any omissions, errors or suggestions for improving this documentation, please contact the GE Healthcare Global Documentation Group with specific information listing the system type, manual title, part number, revision number, page number and suggestion details. Mail the information to: Service Documentation, GE Vingmed Ultrasound AS P.O.Box: 141 NO 3191 HORTEN NORWAY GE Healthcare employees should use TrackWise to report service documentation issues. These issues will then be in the internal problem reporting tool and communicated to the writer.
SERVICE SAFETY CONSIDERATIONS DANGER
DANGEROUS VOLTAGES, CAPABLE OF CAUSING DEATH, ARE PRESENT IN THIS EQUIPMENT. USE EXTREME CAUTION WHEN HANDLING, TESTING AND ADJUSTING.
WARNING USE ALL PERSONAL PROTECTION EQUIPMENT (PPE) SUCH AS GLOVES, SAFETY
SHOES, SAFETY GLASSES, AND KNEELING PAD, TO REDUCE THE RISK OF INJURY. For a complete review of all safety requirements, see Section 1-4 "Safety considerations" on page 1-11.
x
-
GE HEALTHCARE DIRECTION GA091568, REVISION 5
VIVID E9 SERVICE MANUAL
LEGAL NOTES The contents of this publication may not be copied or duplicated in any form, in whole or in part, without prior written permission of GE Healthcare. GE Healthcare may revise this publication from time to time without written notice.
TRADEMARKS All products and their name brands are trademarks of their respective holders.
COPYRIGHTS All Material Copyright© 2008, 2010 - 2012 by General Electric Company Inc. All Rights Reserved.
-
xi
GE HEALTHCARE DIRECTION GA091568, REVISION 5
VIVID E9 SERVICE MANUAL
Revision History
REVISION
DATE
REASON FOR CHANGE
1
2008-NOV-14
Initial release of manual.
2
2010-APR-30
Updated per BT10 release.
3
2011-MAR-01
Updated per BT’11-M4 release of product.
4
2011-SEP-19
Updated per BT’12 release.
5
2012-DEC-10
Updated with changes since Rev. 4.
List of Effected Pages
xii
Pages
Revision
Pages
Revision
Pages
Revision
Title Page
5
4-1 to 4-54
5
9-1 to 9-106
5
i to xii
5
5-1 to 5-102
5
10-1 to 10-32
5
1-1 to 1-36
5
6-1 to 6-18
5
Back Cover
N/A
2-1 to 2-14
5
7-1 to 7-24
5
3-1 to 3-52
5
8-1 to 8-316
5
-
GE HEALTHCARE DIRECTION GA091568, REVISION 5
VIVID E9 SERVICE MANUAL
Table of Contents CHAPTER 1 Introduction Overview...1 - 1 Purpose of this chapter...1 - 1 Contents in this chapter...1 - 1 Service manual overview...1 - 2 Contents in this service manual...1 - 2 Typical users of the Service Manual...1 - 2 VIVID E9 models covered by this manual...1 - 3 Product description...1 - 5 Important conventions...1 - 6 Conventions used in this book...1 - 6 Standard hazard icons...1 - 7 Product icons...1 - 8 Safety considerations...1 - 11 Introduction...1 - 11 Human safety...1 - 11 Mechanical safety...1 - 13 Electrical safety...1 - 15 Labels locations...1 - 16 Label on Front of LCD Monitor...1 - 16 Label on Rear of LCD Monitor...1 - 16 Label on Upper OP Panel...1 - 17 Labels on Front Handle...1 - 17 Labels on top of Console...1 - 17 Labels near Connectors on Front...1 - 18 Labels on DVD Units...1 - 19 Label on External I/O...1 - 19 Labels at AC Mains Inlet and Circuit Breaker...1 - 20 Label on Rear Cover...1 - 21 Label on Rear Cover - detailed descriptions...1 - 26 Label on the BEP6’s door...1 - 29 Label on the BEP5’s door...1 - 30 Label, Disassembly Nester...1 - 31 Table of Contents
xiii
GE HEALTHCARE DIRECTION GA091568, REVISION 5
VIVID E9 SERVICE MANUAL
Dangerous procedure warnings...1 - 32 Lockout/Tagout (LOTO) requirements...1 - 33 Returning/Shipping Probes and Repair Parts...1 - 33 Electromagnetic compatibility (EMC)...1 - 34 What is EMC?...1 - 34 Compliance...1 - 34 Electrostatic discharge (ESD) prevention...1 - 34 Customer assistance...1 - 35 Contact information...1 - 35 System manufacturer...1 - 36
xiv
-
GE HEALTHCARE DIRECTION GA091568, REVISION 5
VIVID E9 SERVICE MANUAL
CHAPTER 2 Site preparations Overview... 2 - 1 Purpose of this chapter... 2 - 1 Contents in this chapter... 2 - 1 General console requirements... 2 - 2 Console environmental requirements... 2 - 2 Electrical requirements... 2 - 4 EMI limitations... 2 - 7 Probes environmental requirements... 2 - 8 Time and manpower requirements... 2 - 8 Facility needs... 2 - 9 Purchaser responsibilities... 2 - 9 Required facility needs... 2 - 10 Desirable features... 2 - 11 Minimal floor plan suggestion... 2 - 11 Suggested Floor Plan, VIVID E9 and EchoPAC PC in Same Room... 2 - 11 Networking setup requirements... 2 - 12
-
xv
GE HEALTHCARE DIRECTION GA091568, REVISION 5
VIVID E9 SERVICE MANUAL
CHAPTER 3 System setup Overview...3 - 1 Purpose of this chapter...3 - 1 Contents in this chapter...3 - 1 Setup reminders...3 - 2 Average setup time...3 - 2 Setup warnings...3 - 2 Receiving and unpacking the equipment...3 - 3 Purpose of this section...3 - 3 Receiving and unpacking warnings...3 - 3 The Tilt & Shock indicators...3 - 4 Receiving the VIVID E9...3 - 5 Unpacking VIVID E9 from the Wooden Box...3 - 10 Unpacking VIVID E9 from the Carton Box...3 - 12 Packing materials for the Wooden Box - recycling information...3 - 16 Packing materials for the Carton Box - recycling information...3 - 17 Preparing for setup...3 - 19 Verify Customer Order...3 - 19 Physical inspection...3 - 19 EMI protection...3 - 19 Completing the setup...3 - 20 Purpose of this section...3 - 20 System specifications...3 - 20 Electrical specifications...3 - 21 Connections on the External IO...3 - 22 Connections on the Patient I/O panel...3 - 23 Connecting Probes...3 - 24 Power On/Boot Up...3 - 26 Power shut down...3 - 26 Configuration...3 - 27 Purpose of this section...3 - 27 VIVID E9 configuration...3 - 27 Service Screen setup...3 - 32 Optional Peripherals/Peripheral Connection...3 - 36 xvi
-
GE HEALTHCARE DIRECTION GA091568, REVISION 5
VIVID E9 SERVICE MANUAL
Software Options Configuration... 3 - 38 Connectivity overview... 3 - 40 Physical connection... 3 - 40 Connectivity setup... 3 - 41 Introduction... 3 - 41 Compatibility... 3 - 41 Select TCP/IP Screen... 3 - 42 Changing the AE Title and/or Port Number (Port No.)... 3 - 43 DHCP setup... 3 - 44 Set the Remote Archive’s Network Information... 3 - 47 Save the New Settings... 3 - 48 Options Setup... 3 - 49 Software options... 3 - 49 Color Video Printer (optional) installation... 3 - 49 Setup paperwork... 3 - 50 User’s Manual(s)... 3 - 50 Product Locator Installation Card... 3 - 51
-
xvii
GE HEALTHCARE DIRECTION GA091568, REVISION 5
VIVID E9 SERVICE MANUAL
CHAPTER 4 General procedures and Functional checks Overview...4 - 1 Purpose of this chapter...4 - 1 Contents in this chapter...4 - 1 Special Equipment required...4 - 2 General procedures...4 - 3 Power ON/Boot Up...4 - 4 Power shut down...4 - 8 Top Console position adjustment...4 - 11 LCD Monitor position adjustment...4 - 14 Logging on to VIVID E9 as ‘ADM’...4 - 15 Moving and Transporting the VIVID E9...4 - 17 Recording important settings and parameters...4 - 19 Cleaning the Trackball from the outside (OP-5)...4 - 31 Cleaning the Trackball (OP-1 to OP-4)...4 - 32 Functional checks...4 - 37 Preparation...4 - 37 2D Mode (B mode) Checks...4 - 37 M Mode Checks...4 - 39 Color Mode Checks...4 - 40 PW/CW Doppler Mode Checks...4 - 42 Tissue Velocity Imaging (TVI) Checks...4 - 43 Probe/Connectors Check...4 - 44 ECG Check...4 - 45 Cineloop Check...4 - 46 Back End Processor checks...4 - 47 Operator Panel Test...4 - 47 Peripheral checks...4 - 47 Mechanical Functions Checks...4 - 51 Site Log...4 - 52
xviii
-
GE HEALTHCARE DIRECTION GA091568, REVISION 5
VIVID E9 SERVICE MANUAL
CHAPTER 5 Components and functions (theory) Overview... 5 - 1 Purpose of this chapter... 5 - 1 Contents in this chapter... 5 - 1 InSite ExC... 5 - 4 Introduction... 5 - 4 InSite ExC Icon... 5 - 4 InSite ExC Status... 5 - 5 Initiating a Request for Service (RFS)... 5 - 6 Automatic Request for Service (ARFS)... 5 - 7 InSite ExC Definitions... 5 - 8 Exiting InSite ExC... 5 - 8 VIVID E9 overview... 5 - 9 Purpose of this section... 5 - 9 Introduction... 5 - 9 VIVID E9 general description... 5 - 10 VIVID E9 block diagram... 5 - 10 Signal flow overview... 5 - 11 System configuration and software... 5 - 12 The electronics... 5 - 12 VIVID E9 interconnection diagram... 5 - 13 VIVID E9’s Operating Modes... 5 - 15 Top Console with LCD monitor and Operator Panel... 5 - 17 Top Console description... 5 - 17 Operator Panel (Control Panel)... 5 - 21 Main Console... 5 - 24 Main Console description... 5 - 24 Air Flow control... 5 - 25 General description... 5 - 25 Casters and Brakes... 5 - 26 Front End Processor (FEP)... 5 - 27 Front End Card Rack description... 5 - 27 Transmitter and Receiver subsystem... 5 - 29 Transmitter Board (GTX)... 5 - 32 -
xix
GE HEALTHCARE DIRECTION GA091568, REVISION 5
VIVID E9 SERVICE MANUAL
Relay Board (RLY)...5 - 38 Receiver Board (GRX)...5 - 41 Front Plane boards (XD BUS)...5 - 43 Digital Receiver board (DRX)...5 - 44 Front End Interface Board (GFI)...5 - 47 FEP Backplane...5 - 50 Back End Processor (BEP)...5 - 52 Purpose of this section...5 - 52 Introduction...5 - 52 Signal Flow and Processing...5 - 52 Location of the Back End Processor (BEP)...5 - 53 CPU/Back End Processor (BEP) - block diagram...5 - 54 BEP description...5 - 55 BEP6 Face, Top and Rear connections...5 - 56 BEP5 Face and Top connections...5 - 58 Input DC Voltages...5 - 63 Input Signals...5 - 64 Bi-directional signals...5 - 65 Outputs...5 - 65 LEDs...5 - 66 BEP Power Supply...5 - 69 IO Board...5 - 74 Graphics Adapter...5 - 76 Internal Storage Devices...5 - 76 Power distribution...5 - 77 Purpose of this section...5 - 77 Main Power Supply...5 - 77 Power Up Sequence Description...5 - 82 Power Down Sequence description...5 - 86 Input and Output (I/O) modules...5 - 88 Purpose of this section...5 - 88 Patient I/O (Physio)...5 - 88 BEP6 I/O Board...5 - 92 BEP5 I/O Board...5 - 94 Probe Connectors...5 - 95 Peripherals overview...5 - 96 Internal peripherals...5 - 96 External peripherals...5 - 97 xx
-
GE HEALTHCARE DIRECTION GA091568, REVISION 5
VIVID E9 SERVICE MANUAL
Product manuals... 5 - 99 User documentation... 5 - 99 Service documentation... 5 - 99 Common Service Desktop overview... 5 - 100 Purpose of this section... 5 - 100 Introduction... 5 - 100 iLinq Interactive Platform Features... 5 - 100 Global Service User Interface (GSUI)... 5 - 101 Restart VIVID E9 after diagnostics... 5 - 102
-
xxi
GE HEALTHCARE DIRECTION GA091568, REVISION 5
VIVID E9 SERVICE MANUAL
CHAPTER 6 Service adjustments Overview...6 - 1 Purpose of this chapter...6 - 1 Contents in this chapter...6 - 1 LCD Monitor adjustments...6 - 2 Purpose of this section...6 - 2 Cautions and Warnings...6 - 2 Access to Adjustments...6 - 2 LCD Adjustment Procedure...6 - 2 Advanced LCD adjustments...6 - 3 Test the LCD Arm and LCD Monitor range of motion...6 - 4 Backlight adjustment...6 - 5 Purpose of this section...6 - 5 Cautions and Warnings...6 - 5 Accessing the Main LCD and Touch Screen Backlight Adjustments...6 - 5 Backlight and Blue Tint Adjustment...6 - 6 Adjust LCD Brightness and Contrast...6 - 6 Test Images...6 - 7 Touch Screen Calibration...6 - 10 DC Offset Calibration (Front End Alignment)...6 - 11 Introduction...6 - 11 When to do a Front End Alignment...6 - 11 Front End Alignment Procedure...6 - 11 Adjusting the XYZ Mechanism...6 - 12 Operator Panel XY movement - principle of operation...6 - 12 Adjusting the XY Lock...6 - 13 XY Manual Release for Lock and Brake Mechanism and Adjustment...6 - 14 Using the Park Lock Properly...6 - 17 Adjusting the Z mechanism...6 - 17 Adjust time-out for DICOM servers...6 - 17
xxii
-
GE HEALTHCARE DIRECTION GA091568, REVISION 5
VIVID E9 SERVICE MANUAL
CHAPTER 7 Diagnostics / troubleshooting Overview... 7 - 1 Purpose of this chapter... 7 - 1 Contents in this chapter... 7 - 1 Service Safety Considerations... 7 - 2 FAQ - Frequently Asked Questions... 7 - 2 High System Temperature Error... 7 - 2 Reset the BEP from a Hang... 7 - 2 How to Release the Top Console when power is unavailable... 7 - 3 Troubleshooting Tips... 7 - 4 Shortcut Keys... 7 - 4 Image Artifacts Caused by Front End Boards... 7 - 5 Back End Processor... 7 - 6 Operator Panel... 7 - 7 Probes... 7 - 7 Software... 7 - 7 Network Connectivity Troubleshooting... 7 - 8 First Status... 7 - 8 Cannot connect to anything via the network... 7 - 8 No Verify... 7 - 9 System Pings and Verifies OK, but does NOT Send... 7 - 9 Gathering Troubleshooting Data... 7 - 10 Collect Vital System Information... 7 - 10 Collect a Trouble Image with Logs... 7 - 11 Screen Captures... 7 - 12 Purpose of this Section... 7 - 12 Ctrl+PrintScreen shortcut... 7 - 12 To Capture a Screen Image Using the Shortcut... 7 - 12 Restart VIVID E9 After Diagnostics... 7 - 12 Motor Controller Test... 7 - 13 Troubleshooting... 7 - 15 No Response from VIVID E9 - It’s “Locked”... 7 - 15 Unable to scan... 7 - 16 -
xxiii
GE HEALTHCARE DIRECTION GA091568, REVISION 5
VIVID E9 SERVICE MANUAL
XY Lock is not working...7 - 17 XY Brake Motors Troubleshooting...7 - 17 Z Movement fails...7 - 17 Difficult to lock and release the alphanumeric keyboard...7 - 18 USB Footswitch...7 - 19 USB Device(s) stopped working...7 - 19 System Temperature Too High...7 - 20 Noise troubleshooting...7 - 21 General Recommendations...7 - 21 EMI Prevention/abatement...7 - 22
xxiv
-