Service Manual
740 Pages
Preview
Page 1
P R E L I M I N A R Y GE Healthcare
1.NOV.2011 VIN-VQN_SVC_FRNT_CVR.FM
Vivid i n and Vivid q N Service Manual Vivid q N with software version Vivid i n with software version Vivid i n with software version
SW 11.x.x (BT11) SW 9.x.x (BT’09) SW 6.x.x (BT’06)
Operating Documentation
Part Number: FQ091013 Revision: 1
P R E L I M I N A R Y GE HEALTHCARE DIRECTION FQ091013, REVISION 1
2.NOV.2011 FRONTMATTER.FM
VIVID I N AND VIVID Q N SERVICE MANUAL
Important Precautions TRANSLATION POLICY
WARNING (EN)
AVERTISSEMENT (FR)
WARNUNG (DE)
THIS SERVICE MANUAL IS AVAILABLE IN ENGLISH ONLY. • IF A CUSTOMER’S SERVICE PROVIDER REQUIRES A LANGUAGE OTHER THAN ENGLISH, IT IS THE CUSTOMER’S RESPONSIBILITY TO PROVIDE TRANSLATION SERVICES. • DO NOT ATTEMPT TO SERVICE THE EQUIPMENT UNLESS THIS SERVICE MANUAL HAS BEEN CONSULTED AND IS UNDERSTOOD. • FAILURE TO HEED THIS WARNING MAY RESULT IN INJURY TO THE SERVICE PROVIDER, OPERATOR OR PATIENT FROM ELECTRIC SHOCK, MECHANICAL OR OTHER HAZARDS. CE MANUEL DE MAINTENANCE N’EST DISPONIBLE QU’EN ANGLAIS. • SI LE TECHNICIEN DU CLIENT A BESOIN DE CE MANUEL DANS UNE AUTRE LANGUE QUE L’ANGLAIS, C’EST AU CLIENT QU’IL INCOMBE DE LE FAIRE TRADUIRE. • NE PAS TENTER D’INTERVENTION SUR LES ÉQUIPEMENTS TANT QUE LE MANUEL SERVICE N’A PAS ÉTÉ CONSULTÉ ET COMPRIS. • LE NON-RESPECT DE CET AVERTISSEMENT PEUT ENTRAÎNER CHEZ LE TECHNICIEN, L’OPÉRATEUR OU LE PATIENT DES BLESSURES DUES À DES DANGERS ÉLECTRIQUES, MÉCANIQUES OU AUTRES. DIESES KUNDENDIENST-HANDBUCH EXISTIERT NUR IN ENGLISCHER SPRACHE. • FALLS EIN FREMDER KUNDENDIENST EINE ANDERE SPRACHE BENÖTIGT, IST ES AUFGABE DES KUNDEN FÜR EINE ENTSPRECHENDE ÜBERSETZUNG ZU SORGEN. • VERSUCHEN SIE NICHT, DAS GERÄT ZU REPARIEREN, BEVOR DIESES KUNDENDIENST-HANDBUCH NICHT ZU RATE GEZOGEN UND VERSTANDEN WURDE. • WIRD DIESE WARNUNG NICHT BEACHTET, SO KANN ES ZU VERLETZUNGEN DES KUNDENDIENSTTECHNIKERS, DES BEDIENERS ODER DES PATIENTEN DURCH ELEKTRISCHE SCHLÄGE, MECHANISCHE ODER SONSTIGE GEFAHREN KOMMEN.
-i
P R E L I M I N A R Y GE HEALTHCARE DIRECTION FQ091013, REVISION 1
HOIATUS (ET)
2.NOV.2011 FRONTMATTER.FM
VIVID I N AND VIVID Q N SERVICE MANUAL
KÄESOLEV TEENINDUSJUHEND ON SAADAVAL AINULT INGLISE KEELES. • KUI KLIENDITEENINDUSE OSUTAJA NÕUAB JUHENDIT INGLISE KEELEST ERINEVAS KEELES, VASTUTAB KLIENT TÕLKETEENUSE OSUTAMISE EEST. • ÄRGE ÜRITAGE SEADMEID TEENINDADA ENNE EELNEVALT KÄESOLEVA TEENINDUSJUHENDIGA TUTVUMIST JA SELLEST ARU SAAMIST. • KÄESOLEVA HOIATUSE EIRAMINE VÕIB PÕHJUSTADA TEENUSEOSUTAJA, OPERAATORI VÕI PATSIENDI VIGASTAMIST ELEKTRILÖÖGI, MEHAANILISE VÕI MUU OHU TAGAJÄRJEL.
(FI)
TÄMÄ HUOLTO-OHJE ON SAATAVILLA VAIN ENGLANNIKSI. • JOS ASIAKKAAN PALVELUNTARJOAJA VAATII MUUTA KUIN ENGLANNINKIELISTÄ MATERIAALIA, TARVITTAVAN KÄÄNNÖKSEN HANKKIMINEN ON ASIAKKAAN VASTUULLA. • ÄLÄ YRITÄ KORJATA LAITTEISTOA ENNEN KUIN OLET VARMASTI LUKENUT JA YMMÄRTÄNYT TÄMÄN HUOLTO-OHJEEN. • MIKÄLI TÄTÄ VAROITUSTA EI NOUDATETA, SEURAUKSENA VOI OLLA PALVELUNTARJOAJAN, LAITTEISTON KÄYTTÄJÄN TAI POTILAAN VAHINGOITTUMINEN SÄHKÖISKUN, MEKAANISEN VIAN TAI MUUN VAARATILANTEEN VUOKSI.
ΠΡΟΕΙΔΟΠΟΙΗΣΗ
ΤΟ ΠΑΡΟΝ ΕΓΧΕΙΡΙΔΙΟ ΣΕΡΒΙΣ ΔΙΑΤΙΘΕΤΑΙ ΣΤΑ ΑΓΓΛΙΚΑ ΜΟΝΟ. • ΕΑΝ ΤΟ ΑΤΟΜΟ ΠΑΡΟΧΗΣ ΣΕΡΒΙΣ ΕΝΟΣ ΠΕΛΑΤΗ ΑΠΑΙΤΕΙ ΤΟ ΠΑΡΟΝ ΕΓΧΕΙΡΙΔΙΟ ΣΕ ΓΛΩΣΣΑ ΕΚΤΟΣ ΤΩΝ ΑΓΓΛΙΚΩΝ, ΑΠΟΤΕΛΕΙ ΕΥΘΥΝΗ ΤΟΥ ΠΕΛΑΤΗ ΝΑ ΠΑΡΕΧΕΙ ΥΠΗΡΕΣΙΕΣ ΜΕΤΑΦΡΑΣΗΣ. • ΜΗΝ ΕΠΙΧΕΙΡΗΣΕΤΕ ΤΗΝ ΕΚΤΕΛΕΣΗ ΕΡΓΑΣΙΩΝ ΣΕΡΒΙΣ ΣΤΟΝ ΕΞΟΠΛΙΣΜΟ ΕΚΤΟΣ ΕΑΝ ΕΧΕΤΕ ΣΥΜΒΟΥΛΕΥΤΕΙ ΚΑΙ ΕΧΕΤΕ ΚΑΤΑΝΟΗΣΕΙ ΤΟ ΠΑΡΟΝ ΕΓΧΕΙΡΙΔΙΟ ΣΕΡΒΙΣ. • ΕΑΝ ΔΕ ΛΑΒΕΤΕ ΥΠΟΨΗ ΤΗΝ ΠΡΟΕΙΔΟΠΟΙΗΣΗ ΑΥΤΗ, ΕΝΔΕΧΕΤΑΙ ΝΑ ΠΡΟΚΛΗΘΕΙ ΤΡΑΥΜΑΤΙΣΜΟΣ ΣΤΟ ΑΤΟΜΟ ΠΑΡΟΧΗΣ ΣΕΡΒΙΣ, ΣΤΟ ΧΕΙΡΙΣΤΗ Ή ΣΤΟΝ ΑΣΘΕΝΗ ΑΠΟ ΗΛΕΚΤΡΟΠΛΗΞΙΑ, ΜΗΧΑΝΙΚΟΥΣ Ή ΑΛΛΟΥΣ ΚΙΝΔΥΝΟΥΣ.
VAROITUS
(EL)
FIGYELMEZTETÉS (HU)
EZEN KARBANTARTÁSI KÉZIKÖNYV KIZÁRÓLAG ANGOL NYELVEN ÉRHETŐ EL. • HA A VEVŐ SZOLGÁLTATÓJA ANGOLTÓL ELTÉRŐ NYELVRE TART IGÉNYT, AKKOR A VEVŐ FELELŐSSÉGE A FORDÍTÁS ELKÉSZÍTTETÉSE. • NE PRÓBÁLJA ELKEZDENI HASZNÁLNI A BERENDEZÉST, AMÍG A KARBANTARTÁSI KÉZIKÖNYVBEN LEÍRTAKAT NEM ÉRTELMEZTÉK. • EZEN FIGYELMEZTETÉS FIGYELMEN KÍVÜL HAGYÁSA A SZOLGÁLTATÓ, MŰKÖDTETŐ VAGY A BETEG ÁRAMÜTÉS, MECHANIKAI VAGY EGYÉB VESZÉLYHELYZET MIATTI SÉRÜLÉSÉT EREDMÉNYEZHETI.
-iii
P R E L I M I N A R Y GE HEALTHCARE DIRECTION FQ091013, REVISION 1
2.NOV.2011 FRONTMATTER.FM
VIVID I N AND VIVID Q N SERVICE MANUAL
BRĪDINĀJUMS (LV)
ŠĪ APKALPES ROKASGRĀMATA IR PIEEJAMA TIKAI ANGĻU VALODĀ. • JA KLIENTA APKALPES SNIEDZĒJAM NEPIECIEŠAMA INFORMĀCIJA CITĀ VALODĀ, NEVIS ANGĻU, KLIENTA PIENĀKUMS IR NODROŠINĀT TULKOŠANU. • NEVEICIET APRĪKOJUMA APKALPI BEZ APKALPES ROKASGRĀMATAS IZLASĪŠANAS UN SAPRAŠANAS. • ŠĪ BRĪDINĀJUMA NEIEVĒROŠANA VAR RADĪT ELEKTRISKĀS STRĀVAS TRIECIENA, MEHĀNISKU VAI CITU RISKU IZRAISĪTU TRAUMU APKALPES SNIEDZĒJAM, OPERATORAM VAI PACIENTAM.
ĮSPĖJIMAS (LT)
ŠIS EKSPLOATAVIMO VADOVAS YRA IŠLEISTAS TIK ANGLŲ KALBA. • JEI KLIENTO PASLAUGŲ TEIKĖJUI REIKIA VADOVO KITA KALBA – NE ANGLŲ, VERTIMU PASIRŪPINTI TURI KLIENTAS. • NEMĖGINKITE ATLIKTI ĮRANGOS TECHNINĖS PRIEŽIŪROS DARBŲ, NEBENT VADOVAUTUMĖTĖS ŠIUO EKSPLOATAVIMO VADOVU IR JĮ SUPRASTUMĖTE • NEPAISANT ŠIO PERSPĖJIMO, PASLAUGŲ TEIKĖJAS, OPERATORIUS AR PACIENTAS GALI BŪTI SUŽEISTAS DĖL ELEKTROS SMŪGIO, MECHANINIŲ AR KITŲ PAVOJŲ.
ADVARSEL (NO)
DENNE SERVICEHÅNDBOKEN FINNES BARE PÅ ENGELSK. • HVIS KUNDENS SERVICELEVERANDØR TRENGER ET ANNET SPRÅK, ER DET KUNDENS ANSVAR Å SØRGE FOR OVERSETTELSE. • IKKE FORSØK Å REPARERE UTSTYRET UTEN AT DENNE SERVICEHÅNDBOKEN ER LEST OG FORSTÅTT. • MANGLENDE HENSYN TIL DENNE ADVARSELEN KAN FØRE TIL AT SERVICELEVERANDØREN, OPERATØREN ELLER PASIENTEN SKADES PÅ GRUNN AV ELEKTRISK STØT, MEKANISKE ELLER ANDRE FARER.
OSTRZEŻENIE (PL)
NINIEJSZY PODRĘCZNIK SERWISOWY DOSTĘPNY JEST JEDYNIE W JĘZYKU ANGIELSKIM. • JEŚLI FIRMA ŚWIADCZĄCA KLIENTOWI USłUGI SERWISOWE WYMAGA UDOSTĘPNIENIA PODRĘCZNIKA W JĘZYKU INNYM NIŻ ANGIELSKI, OBOWIĄZEK ZAPEWNIENIA STOSOWNEGO TłUMACZENIA SPOCZYWA NA KLIENCIE. • NIE PRÓBOWAĆ SERWISOWAĆ NINIEJSZEGO SPRZĘTU BEZ UPRZEDNIEGO ZAPOZNANIA SIĘ Z PODRĘCZNIKIEM SERWISOWYM. • NIEZASTOSOWANIE SIĘ DO TEGO OSTRZEŻENIA MOżE GROZIĆ OBRAŻENIAMI CIAłA SERWISANTA, OPERATORA LUB PACJENTA W WYNIKU PORAŻENIA PRĄDEM, URAZU MECHANICZNEGO LUB INNEGO RODZAJU ZAGROŻEŃ.
-v
P R E L I M I N A R Y
GE HEALTHCARE DIRECTION FQ091013, REVISION 1
DİKKAT (TR)
(JA)
Traditional Chinese
-viii
2.NOV.2011 FRONTMATTER.FM
VIVID I N AND VIVID Q N SERVICE MANUAL
BU SERVİS KILAVUZU YALNIZCA İNGİLİZCE OLARAK SAĞLANMIŞTIR. • EĞER MÜŞTERİ TEKNİSYENİ KILAVUZUN İNGİLİZCE DIŞINDAKİ BİR DİLDE OLMASINI İSTERSE, KILAVUZU TERCÜME ETTİRMEK MÜŞTERİNİN SORUMLULUĞUNDADIR. • SERVİS KILAVUZUNU OKUYUP ANLAMADAN EKİPMANLARA MÜDAHALE ETMEYİNİZ. • BU UYARININ GÖZ ARDI EDİLMESİ, ELEKTRİK ÇARPMASI YA DA MEKANİK VEYA DİĞER TÜRDEN KAZALAR SONUCUNDA TEKNİSYENİN, OPERATÖRÜN YA DA HASTANIN YARALANMASINA YOL AÇABİLİR.
2.NOV.2011 FRONTMATTER.FM
P R E L I M I N A R Y
GE HEALTHCARE DIRECTION FQ091013, REVISION 1
VIVID I N AND VIVID Q N SERVICE MANUAL
DAMAGE IN TRANSPORTATION All packages should be closely examined at time of delivery. If damage is apparent write “Damage In Shipment” on ALL copies of the freight or express bill BEFORE delivery is accepted or “signed for” by a GE representative or hospital receiving agent. Whether noted or concealed, damage MUST be reported to the carrier immediately upon discovery, or in any event, within 14 days after receipt, and the contents and containers held for inspection by the carrier. A transportation company will not pay a claim for damage if an inspection is not requested within this 14 day period.
CERTIFIED ELECTRICAL CONTRACTOR STATEMENT - FOR USA ONLY All electrical Installations that are preliminary to positioning of the equipment at the site prepared for the equipment shall be performed by licensed electrical contractors. Other connections between pieces of electrical equipment, calibrations and testing shall be performed by qualified GE Healthcare personnel. In performing all electrical work on these products, GE will use its own specially trained field engineers. All of GE’s electrical work on these products will comply with the requirements of the applicable electrical codes. The purchaser of GE equipment shall only utilize qualified personnel (i.e., GE’s field engineers, personnel of third-party service companies with equivalent training, or licensed electricians) to perform electrical servicing on the equipment.
OMISSIONS & ERRORS If there are any omissions, errors or suggestions for improving this documentation, please contact the GE Healthcare Global Documentation Group with specific information listing the system type, manual title, part number, revision number, page number and suggestion details. Mail the information to: Service Documentation, GE Vingmed Ultrasound AS P.O.Box: 141 NO 3191 HORTEN NORWAY GE Healthcare employees should use TrackWise to report service documentation issues. These issues will then be in the internal problem reporting tool and communicated to the writer.
SERVICE SAFETY CONSIDERATIONS DANGER
DANGEROUS VOLTAGES, CAPABLE OF CAUSING DEATH, ARE PRESENT IN THIS EQUIPMENT. USE EXTREME CAUTION WHEN HANDLING, TESTING AND ADJUSTING.
WARNING Use all Personal Protection Equipment (PPE) such as gloves, safety shoes, safety
glasses, and kneeling pad, to reduce the risk of injury. For a complete review of all safety requirements, see the Safety Considerations section in Chapter 1.
-x
P R E L I M I N A R Y GE HEALTHCARE DIRECTION FQ091013, REVISION 1
2.NOV.2011 FRONTMATTER.FM
VIVID I N AND VIVID Q N SERVICE MANUAL
LEGAL NOTES The contents of this publication may not be copied or duplicated in any form, in whole or in part, without prior written permission of GE Healthcare. GE Healthcare may revise this publication from time to time without written notice.
TRADEMARKS All products and their name brands are trademarks of their respective holders.
COPYRIGHTS All Material Copyright© 2011 by General Electric Company Inc. All Rights Reserved.
-xi
2.NOV.2011 FRONTMATTER.FM
P R E L I M I N A R Y
GE HEALTHCARE DIRECTION FQ091013, REVISION 1
VIVID I N AND VIVID Q N SERVICE MANUAL
Revision History
REVISION
DATE
REASON FOR CHANGE
1
2011 NOV. 02
Initial release.
List of Effected Pages (LOEP) Pages
Revision
Pages
Revision
Pages
Revision
Title Page
1
1-1 to 1-26
1
7-1 to 7-176
1
Warnings i to -xii
1
2-1 to 2-12
1
8-1 to 8-154
1
TOC
1
3-1 to 3-180
1
9-1 to 9-20
1
4-1 to 4-40
1
10-1 to 10-36
1
5-1 to 5-48
1
Back Cover
N/A
6-1 to 6-16
1
-xii
GE HEALTHCARE DIRECTION FQ091013, REVISION 1
VIVID I N AND VIVID Q N SERVICE MANUAL
Table of Contents CHAPTER 1 Introduction Overview... 1 - 1 Purpose of Chapter 1... 1 - 1 Purpose of Service Manual... 1 - 2 Typical Users of the Service Manual (This Manual)... 1 - 2 Vivid i n Models Covered in this Manual... 1 - 3 Vivid q N Models Covered in this Manual... 1 - 3 System History - Hardware and Software Versions... 1 - 4 Purpose of Operator Manual(s)... 1 - 4 Important Conventions... 1 - 5 Conventions Used in this Manual... 1 - 5 Safety Considerations... 1 - 7 Introduction... 1 - 7 Human Safety... 1 - 7 Mechanical Safety... 1 - 7 Electrical Safety... 1 - 9 Dangerous Procedure Warnings... 1 - 11 Product Labels and Icons... Universal Product Labels... Label Descriptions... Vivid i n/ Vivid q N Battery Safety... Vivid i n and Vivid q N External Labels... SafeLock Cart Labels...
1 - 12 1 - 12 1 - 14 1 - 17 1 - 19 1 - 20
EMC, EMI, and ESD... Electromagnetic Compatibility (EMC)... CE Compliance... Electrostatic Discharge (ESD) Prevention... Standards Used...
1 - 21 1 - 21 1 - 21 1 - 21 1 - 22
Lockout/Tagout (LOTO) Requirements... 1 - 23 Returning/Shipping Probes and Repair Parts... 1 - 24 Customer Assistance... 1 - 25 Table of Contents
-xiii
GE HEALTHCARE DIRECTION FQ091013, REVISION 1
VIVID I N AND VIVID Q N SERVICE MANUAL
Contact Information... 1 - 25 System manufacturer... 1 - 26
-xiv
GE HEALTHCARE DIRECTION FQ091013, REVISION 1
VIVID I N AND VIVID Q N SERVICE MANUAL
CHAPTER 2 Site Preparations Overview...2 - 1 Purpose of Chapter 2... 2 - 1 Console Requirements... 2 - 2 Unit Environmental Requirements... 2 - 2 Cooling Requirements... 2 - 2 Lighting Requirements... 2 - 2 Time and Manpower Requirements... 2 - 2 Electrical Requirements... 2 - 3 EMI Limitations... 2 - 4 Probe Environmental Requirements... 2 - 5 Facility Needs... 2 - 6 Purchaser Responsibilities... 2 - 6 Mandatory Site Requirements... 2 - 7 Site Recommendations... 2 - 7 Networking Pre-Installation Requirements... 2 - 9 Connectivity Installation Worksheet... 2 - 10 Check List... 2 - 12
-xv
GE HEALTHCARE DIRECTION FQ091013, REVISION 1
VIVID I N AND VIVID Q N SERVICE MANUAL
CHAPTER 3 System Setup Overview... 3 - 1 Purpose of Chapter 3... 3 - 1 Installation Reminders... Average Installation Time... Installation Warnings... Safety Reminders... The Tilt & Shock Indicators...
3-2 3-2 3-2 3-3 3-4
Receiving the Vivid i n and Vivid q N... 3 - 5 Examin All Packages... 3 - 5 Damage in Transportation... 3 - 6 Unpacking the Equipment... 3 - 9 Examin All Packages... 3 - 10 Unpacking the Wooden Transportation box... 3 - 11 Verifying the Transportation box Contents... 3 - 12 Physical Inspection... 3 - 12 EMI Protection... 3 - 12 Preparing for Installation... Confirming Customer Order... Verifying the Transportation Box Contents... Component Inspection... Confirming SafeLock Cart Voltage Configuration... System Voltage Confirmation...
3 - 13 3 - 13 3 - 13 3 - 14 3 - 19 3 - 19
Ensuring Protection from EMI... 3 - 20 Completing the Hardware Installation... Connecting Printers... Connecting Peripherals... Charging the Battery... Connecting Probes... Connecting the ECG... Connecting the Unit to a Power Source... Switching the System ON/OFF...
3 - 21 3 - 21 3 - 34 3 - 55 3 - 58 3 - 61 3 - 62 3 - 64
Mounting the Vivid i n/ Vivid q N on the SafeLock Cart (optional)... 3 - 65 Mounting the Vivid i n and Vivid q N on the SafeLock Cart... 3 - 65 -xvi
GE HEALTHCARE DIRECTION FQ091013, REVISION 1
VIVID I N AND VIVID Q N SERVICE MANUAL
Adjusting the SafeLock Cart Locking Mechanism... 3 - 68 Configuration... 3 - 69 Overview... 3 - 69 Vivid i n/ Vivid q N Configuration... 3 - 70 Service Screen Set-up... 3 - 75 Configuring Peripherals... 3 - 81 Software Options Configuration... 3 - 84 Connectivity Setup... 3 - 85 Connectivity Introduction... 3 - 85 Physical Connection... 3 - 88 Connectivity Configuration... 3 - 98 Set Up Connection to a DICOM Server in a Network... 3 - 110 Setup Connection to HL7 Server in a Network... 3 - 117 Query/Retrieve (Q/R) Setup... 3 - 120 MPEGVue Export Configuration... 3 - 127 eVue Dataflow Configuration... 3 - 132 Using MPEGVue/eVue on a Remote PC... 3 - 136 Storing and Transporting the Unit... 3 - 177 Safety Precautions for Moving the Vivid i n/ Vivid q N Unit... 3 - 177 Transportation Box and Packaging Materials... 3 - 177 Completing the Installation Paperwork... 3 - 178 System Installation Details... 3 - 178 Product Locator Installation... 3 - 178 Product Locator Installation Card... 3 - 179 User Manual(s)... 3 - 180
-xvii
GE HEALTHCARE DIRECTION FQ091013, REVISION 1
VIVID I N AND VIVID Q N SERVICE MANUAL
CHAPTER 4 General Procedures and Functional Checks Overview... 4 - 1 Purpose of Chapter 4... 4 - 1 Specific Equipment Required... 4 - 2 General Procedures... 4 - 3 Overview... 4 - 3 Power ON/Boot-up... 4 - 3 Power Shut Down... 4 - 7 Log On to the System as ADM... 4 - 10 Using Removable Media... 4 - 12 Labeling Removable Media... 4 - 15 Formatting Removable Media... 4 - 15 Verifying Removable Media... 4 - 16 Archiving and Loading Presets... 4 - 17 Functional Checks... Basic Controls... Peripherals... SafeLock Cart Functional Tests... Back End Processor Tests...
4 - 19 4 - 19 4 - 28 4 - 33 4 - 34
System Turnover Checklist... 4 - 37 Software Configuration Checks... 4 - 37 Site Log... 4 - 38
-xviii
GE HEALTHCARE DIRECTION FQ091013, REVISION 1
VIVID I N AND VIVID Q N SERVICE MANUAL
CHAPTER 5 Components and Function (Theory) Overview...5 - 1 Purpose of Chapter 5... 5 - 1 General Information... 5 - 2 Introduction... 5 - 2 Signal Flow... 5 - 4 Vivid i n and Vivid q N Systems - Block Diagram... 5 - 5 Front End Unit... 5 - 6 General Information... 5 - 6 Front End Unit - Location in the System... 5 - 9 RFI Board... 5 - 11 TR32 Boards (Transmitter/Receiver)... 5 - 15 Probe and MUX (P&M) Board... 5 - 18 Back End Processor... 5 - 21 Introduction... 5 - 21 ETX SBC Central Processing Unit (CPU)... 5 - 23 ETX Base Board... 5 - 23 Hard Disk... 5 - 25 Fan Control... 5 - 25 RTC (BIOS) Battery... 5 - 25 Back End Processor - Location of Components... 5 - 26 Left/Right Speakers... 5 - 28 External Input/Output (I/O)... 5 - 29 Power Supply System... 5 - 30 Electrical Power... 5 - 30 Introduction... 5 - 30 Power Supply Unit Components... 5 - 31 DC Source Selector... 5 - 31 Rechargeable Battery Pack Assy (GPA)... 5 - 32 Monitor and Operator Panel... 5 - 34 Keyboard and Operator Panel... 5 - 34 Keyboard and Operator Panel Components... 5 - 35 ECG Module...5 - 39 Overview... 5 - 39 -xix
GE HEALTHCARE DIRECTION FQ091013, REVISION 1
VIVID I N AND VIVID Q N SERVICE MANUAL
ECG Patient I/O Module Specifications... 5 - 40 Isolation... 5 - 40 ECG/Respiratory Module... 5 - 41 Internal ECG/Respiratory Board... 5 - 41 External ECG/Respiratory Interface... 5 - 43 Peripherals... 5 - 46 Introduction... 5 - 46 Cooling System... 5 - 48 General Information... 5 - 48
-xx
GE HEALTHCARE DIRECTION FQ091013, REVISION 1
VIVID I N AND VIVID Q N SERVICE MANUAL
CHAPTER 6 Service Adjustments Overview...6 - 1 Purpose of Chapter 6... 6 - 1 LCD Display Adjustments and Calibration... 6 - 2 Contrast Adjustment Procedure... 6 - 2 Brightness Adjustment Procedure... 6 - 3 Testing Your Contrast and Brightness Settings... 6 - 3 Blue Tint Adjustment Procedure... 6 - 3 Blue Tint "2" Adjustment Procedure... 6 - 5 External Monitor Calibration... 6 - 8 Keyboard Adjustments... 6 - 10 Configuring Print Orientation... 6 - 10 Video System Adjustments... 6 - 10 Beamformer Calibration... 6 - 10 Battery Calibration... 6 - 11
-xxi
GE HEALTHCARE DIRECTION FQ091013, REVISION 1
VIVID I N AND VIVID Q N SERVICE MANUAL
CHAPTER 7 Diagnostics/Troubleshooting Overview... 7 - 1 Purpose of Chapter... 7 - 1 Diagnostics... 7 - 2 Diagnostic Tools... 7 - 2 Diagnostic Procedure Summary... 7 - 2 Accessing the Diagnostic Test Window... 7 - 3 Diagnostic Test Window Menu Options... 7 - 10 Performing Full System Diagnostics... 7 - 19 Accessing the Full System Diagnostic Options... 7 - 20 Performing Front End (FE) Diagnostics... Accessing the Front End Diagnostic Options... Calibration Tests... Radio Frequency Interface (RFI) Diagnostic Tests... TR 32 Diagnostic Tests... Probe and MUX Diagnostic Tests...
7 - 24 7 - 25 7 - 25 7 - 31 7 - 46 7 - 61
Monitoring Tests... 7 - 86 Accessing the Monitoring Diagnostic Test Options... 7 - 86 Performing Back End Diagnostics on the System... 7 - 108 Accessing the Back End Diagnostic Test Options... 7 - 108 InSite ExC... Service Desktop... Error Logs Page... Diagnostics Page... Image Quality Page... Calibration Page... Configuration Page... *.ZipUtilities Page... Replacement Page... PM Page...
7 - 137 7 - 137 7 - 139 7 - 144 7 - 151 7 - 151 7 - 152 7 - 153 7 - 165 7 - 165
Automatic Error Log... 7 - 166 Adding Bookmarks... 7 - 166 Extracting Logs... 7 - 166
-xxii
GE HEALTHCARE DIRECTION FQ091013, REVISION 1
VIVID I N AND VIVID Q N SERVICE MANUAL
CHAPTER 8 Replacement Procedures Overview...8 - 1 Purpose of Chapter 8... 8 - 1 External Component Replacement Procedures... 8 - 3 Bearing Handle Replacement Procedure... 8 - 3 Battery Replacement Procedure... 8 - 5 Hard Disk Replacement Procedure... 8 - 7 Control Panel and Keyboard Replacement Procedure... 8 - 9 Rear Cover & Latch Assembly Replacement Procedure... 8 - 19 LCD Display Cover Hinges Replacement Procedure... 8 - 21 Bottom Assembly Replacement Procedure... 8 - 25 LCD Display Frame Replacement Procedure... 8 - 27 Internal Component Replacement Procedures... 8 - 29 P&M (Probe and MUX) Board Replacement Procedure... 8 - 29 TR32 and RFI Boards Replacement Procedure... 8 - 32 BEP Replacement Procedure... 8 - 38 BIOS Battery Replacement... 8 - 45 HVPS Replacement Procedure... 8 - 46 Fan Replacement Procedure... 8 - 49 Speaker Assembly Replacement Procedure... 8 - 52 LCD Display Replacement Procedure... 8 - 53 LCD Flex Cable Replacement Procedure... 8 - 58 SafeLock Cart Components Replacement... 8 - 61 Overview of SafeLock Cart Replaceable Components... 8 - 62 SafeLock Cart Replacement Procedures - Quick Reference List... 8 - 63 Upper Cover (Rear) Replacement Procedure... 8 - 64 AC Cable Hook Replacement Procedure... 8 - 65 AC Power Cable Bumper Protector Replacement Procedure... 8 - 66 ECG Cable Protector Replacement Procedure... 8 - 68 Lower Cover (Rear) Replacement Procedure... 8 - 71 AC Distribution Assembly Replacement Procedure... 8 - 72 Peripheral Power Cable Replacement Procedure... 8 - 74 Main Cable Harness Replacement Procedure... 8 - 79 USB Board Replacement Procedure... 8 - 80 Gas Spring Replacement Procedure... 8 - 82 DVD Holder Replacement Procedure... 8 - 85 LAN Isolation Box and Holder Replacement Procedure... 8 - 86 -xxiii
GE HEALTHCARE DIRECTION FQ091013, REVISION 1
VIVID I N AND VIVID Q N SERVICE MANUAL
Top Shelf Replacement Procedure... Handrest Replacement Procedure... Probe Shelf Assembly Replacement Procedure... Probe Cable Hook Replacement Procedure... Front Wheel Replacement Procedure... Rear Wheel Replacement Procedure...
8 - 87 8 - 89 8 - 90 8 - 92 8 - 93 8 - 95
Software Loading... 8 - 97 Software Upgrade Procedure Overview... 8 - 97 Setting the BIOS... 8 - 108 BIOS Firmware Update... 8 - 118 Formatting and Partitioning the Hard Disk - Automatic Procedure... 8 - 121 Formatting and Partitioning the Hard Disk - Manual Procedure... 8 - 123 Full Re-ghost and Software Installation... 8 - 128 Installing Software only from DVD... 8 - 130 Installing Software only or Patch... 8 - 134 Installation of PMC Version... 8 - 135 Software Roll-back Procedure... 8 - 139 Performing a Complete System Back-up... 8 - 141 Database Merge... 8 - 141 How to Restore User-defined Presets... 8 - 147 Peripherals... 8 - 148 Connecting and Removing Peripherals... 8 - 148 External USB Hard Disk Replacement Procedure... 8 - 150
-xxiv