HANS RUDOLPH

Pneumotachometers

PA1 Operating Instructions Rev E Aug 2018

Operating Instructions

2 Pages

MAKERS OF RESPIRATORY VALVES SINCE 1938  HANS RUDOLPH, inc.  TM  Data Sheet...  8325 COLE PARKWAY, SHAWNEE, KANSAS 66227 U.S.A.  PNEUMOTACH AMPLIFIER 1  TEL: (913) 422-7788 FAX: (913) 422-3337  Analog Output for Flow and Pressure  U.S.A. & CANADA: (800) 456-6695 E-mail: hri@rudolphkc.com www.rudolphkc.com  Series 1110  DESCRIPTION The Hans Rudolph Pneumotach Amplifier 1 (PA-1) provides the instrumentation necessary to produce an analog output proportional to flow when connected to any of our standard pneumotachs. It will also provide an analog output of an independent auxiliary pressure signal for measurement of pressure anywhere in the circuit. The Pneumotach Amplifier 1 works with any of the Hans Rudolph Linear Bi-directional screen Pneumotachs. These are available in eight different calibrated flow ranges in heated and non-heated versions. Hans Rudolph Pneumotachs are sold separately. Refer to Data Sheet 691037 for complete information and part numbers. The Pneumotach Amplifier 1 (PA-1) measures gas flow using the differential pressure method. As gas flows through the pneumotach a small differential pressure is produced at the output pressure ports on the pneumotach. These ports are connected to the Pneumotach Amplifier 1 flow input ports with a small diameter tube. The differential pressure signal is measured by a sensitive +/- 2cmH2O pressure transducer and amplified to provide an analog output proportional to the flow rate. A linearizing circuit corrects for the slight nonlinearity of the pneumotach output. An additional differential pressure sensor is provided for measuring pressure in the airway by connecting the positive pressure port to the airway and leaving the other port open to atmosphere. It can also be used to measure a differential pressure by connecting both sensor ports to different points in the circuit. The analog outputs can be configured for different voltage ranges to ease connection to your data acquisition system. The outputs can be configured for unipolar or bipolar operation in each output range. Offset and gain adjustment pots are available for adjusting the zero and calibration. FEATURES •  Use with Hans Rudolph Linear Screen Pneumotachs. Flow Ranges from 0-3, 0-5, 0-10, 0-35, 0-100, 0-160, 0-400 & 0-800 lpm.  •  Pressure measurement –70 to 70 cmH2O (6.9 kPa), –140 to 140 cmH2O (13.7 kPa) or custom ranges available on request.  •  Zero and gain adjust pots for both outputs.  •  BNC type analog output jacks.  •  Flow direction indicator LED.  •  Custom pressure transducers available at extra cost  Optional &/or Replacement Parts for Auxiliary Pressure 200122		 Hose barb, 3.17 mm (.125 in.) pressure port		 		Installed at auxiliary location per customer		 		 specifications for pressure measurement. 200123		 		 		  Female luer lock pressure port Installed at auxiliary location per customer specifications for pressure measurement.  171212		 		 		 		  Coupler, male luer lock to 3.17 mm (.125 in.) hose barb, required for connecting single tube assembly		 (666006) to auxiliary pressure port when ordering option 200123.  666007		 		 		  Dual tube assembly, 3.17mm (.125 in.) ID with male luer lock fittings to mate pneumotach to Pneumotach Amplifier 1 (supplied with PA-1).  666006		 		 		  Single tube assembly, 3.17 mm (.125 in.) ID with		 male luer lock for connection to auxiliary pressure port on PA-1 (supplied with PA-1).  SPECIFICATIONS •  Analog flow output in ranges of 0 to 2, -1 to 1, 0 to 5, –2.5 to 2.5, 0 to 10 or –5 to 5 volts.  •  Analog pressure output –1 to 1 or –5 to 5 volts. Both ranges can be offset 20% to create a unipolar signal.  •  115 or 230 VAC, 50/60 Hz supply.  •  203 mm (8 in.) W x 178 mm (7 in.) D x 63 mm (2.5 in.) H size.  PNEUMOTACH INFORMATION SERIES  APPLICATION  FLOW RANGE (LPM)  8430/8431  MOUSE  0-3  ORDERING INFORMATION  8420-8421  Mouse, Rat, Guinea Pig  0-5  (Power Cord Set is included please specify the country)  8410/8411  1 Premature, Feline  0-10  8300/8311  2 Neonate, Rabbit  0-10  3500/4500  3 Infant, Small Canine  0-35  3719/4719  Pediatrics, Canine  0-100  3700/4700  Pediatrics, Adults at Large Canine  P/N		  Description  113252		 		 		  Pneumotach Amplifier 1 (PA1) configured for 		 ONE Pneumotach (Flow) and ONE Auxiliary 		 Pressure range of -70 to 70 cmH2O (-6.9 to 6.9 kPa)  113253		 		 		  Pneumotach Amplifier 1 (PA1) configured for ONE Pneumotach (Flow) and ONE Auxiliary Pressure 		 range of -140 to 140 cmH2O (-13.7 to 13.7 kPa)  113834		 		  Pneumotach Amplifier 1 (PA1) configured for TWO Pneumotachs (Flow)  955072		  Calibration PA1 and ONE Pneumotach  rest,  0-160  3830/4830  Adult PFT, Spirometry  0-400  3813/4813  Athlete, Spirometry  0-800  1 Less than 38 week gestational 2 Birth to one month 3 1-12 months  CAUTION: This device is for research purposes only, do not base clinical decisions on information obtained from this device. PRINTED IN U.S.A. 691224-1 2017-08-02 Rev. E  Specifications subject to change without notice  ISO 13485 © 2017 Hans Rudolph, inc.
File Type: PDF
File Size: 297 KB
File Name: pa1_operating_instructions_rev_e_aug_2018.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions