Instructions for use Accessories for bronchoscope and tracheoscope
02-2021 Copyright © All product illustrations, product descriptions, and texts are the intellectual property of KARL STORZ SE & Co. KG. Their use and reproduction by third parties require the express approval of KARL STORZ SE & Co. KG. All rights reserved.
Table of contents
Table of contents 1 General information... 4 1.1 Read the instructions for use ... 4 1.2 Read the instructions for use of combinable products... 4 1.3 Scope... 4 1.4 Description of warning messages... 5 2 Normal use... 6 2.1 Intended use ... 6 2.2 Indications... 6 2.3 Contraindications... 7 2.4 Target user populations ... 7 2.5 Patient groups... 7 3 Safety ... 8 3.1 Serious incidents ... 8 3.2 Unsterile product ... 8 3.3 Correct handling ... 8 3.4 Damaged products ... 8 3.5 Creutzfeldt-Jakob disease ... 8 3.6 Hot components ... 9 3.7 High light intensity ... 9 3.8 Patient leakage current ... 9 3.9 Disposal of pointed and sharp products ... 9 3.10 Appropriate combination of endoscope and fiber optic light cable ... 9 4 Product description ... 10 4.1 Product overview ... 10 4.2 Possible combinations... 12 4.2.1 Bronchoscope for adults - light carriers/prismatic light deflectors/sealing caps/injection cannulas/adapters ... 12 4.2.2 Bronchoscopes for children - light carriers/prismatic light deflectors/sealing caps/injection cannulas/adapters ... 13 4.2.3 Child bronchoscopes with telescopic bridges and telescopes... 13 4.3 Symbols on the packaging ... 14 4.4 Ambient conditions ... 15 5 Maintenance, servicing, repairs, and disposal... 16 5.1 Maintaining the product ... 16 5.2 Repairs to the product ... 16 5.3 Disposing of the product ... 16 6 Accessories and spare parts ... 17 6.1 Accessories... 17 6.2 Spare parts ... 17 7 Subsidiaries... 18
Instructions for use • Accessories for bronchoscope and tracheoscope • UTW506_EN_V1.0_02-2021_IFU_CEMDR
3
General information
1 General information 1.1 Read the instructions for use If the instructions for use are not followed, patients, users, and third parties may be injured or the product may be damaged. Read the instructions for use carefully and follow all the safety notes and warnings. Keep the instructions for use clearly visible next to the product.
1.2 Read the instructions for use of combinable products If the instructions for use of combinable products are not followed, patients, users, and third parties may be injured or the product may be damaged. Read the instructions for use of the combinable products carefully and follow all the safety notes and warnings.
1.3 Scope This instruction manual is valid for: Product name
Art. no.
Injection cannula needle
10071Y
Prismatic light deflector
10101FA
Prismatic light deflector
10101HA
Sealing cap with window
10314BM
Sealing cap with rubber seal
10314BN
FLUVOG attachment, movable
10314P
Sealing cap, with window
10315M
Sealing cap with rubber seal
10315N
FLUVOG attachment, movable
10315P
Blind plug
10315RV
Respirator attachment, for 10316 AS-DS
10316LR
Injection cannula, outer diameter 3.5 mm
10318K
Injection cannula, double lumen
10318KD
Fiber optic light carrier
10318L
Instrument guide, for suction catheter
10318S
Injection cannula, outer diameter 2.7 mm
10338K
Telescope bridge
10338LCD
Telescope bridge
10338LCI
Sealing cap, with window
10338M
Sealing cap, with rubber seal
10338N
FLUVOG attachment, movable
10338P
Telescope bridge
10338R
Instructions for use • Accessories for bronchoscope and tracheoscope • UTW506_EN_V1.0_02-2021_IFU_CEMDR
4
General information
Product name
Art. no.
Telescope bridge
10338RK
Telescope bridge
10338RL
Instrument guide, short, for suction catheter
10338S
Adaptor for respirator
10924D
Adaptor for respirator
10924DL
Vent plug
10924E
Suction nozzle
10924SP
1.4 Description of warning messages To prevent any injury to persons or damage to property, the warnings and safety notes in the instructions for use must be observed. The warning messages describe the following levels of danger. WARNING WARNING Designates a possible imminent risk. If this is not avoided, it could lead to death or serious injuries. CAUTION CAUTION Designates a possible imminent risk. If this is not avoided, it could lead to minor injuries. ATTENTION ATTENTION Designates a possibly harmful situation. If this is not avoided, the products could be damaged.
Instructions for use • Accessories for bronchoscope and tracheoscope • UTW506_EN_V1.0_02-2021_IFU_CEMDR
5
Normal use
2 Normal use 2.1 Intended use Injection needles Injection needles are used for introducing fluids into the trachea and the bronchial system in bronchoscopy. Injection needles are non-invasive and meant for transient use in invasive procedures through a body orifice. Injection cannulas Injection cannulas are used to respirate the patient in conjunction with a high frequency respirator and a rigid bronchoscope or tracheoscope in bronchoscopy. Injection cannulas are non-invasive and meant for transient use in invasive procedures through a body orifice. Prismatic light deflectors Prismatic light deflectors are used for proximal illumination in rigid bronchoscopes, tracheoscopes, and esophagoscopes. Prismatic light deflectors are non-invasive and are designed for transient use in invasive procedures through a body orifice. Sealing caps, FLUVOG attachments, instrument guides and blind plugs Sealing caps are used for closing the proximal openings of rigid bronchoscopes, tracheoscopes, and esophagoscopes. Sealing caps are non-invasive and are designed for transient use in surgically invasive procedures or invasive procedures through a body orifice. Fiber optic light carriers Fiber optic light carriers are used for distal illumination on the rigid bronchoscope. Fiber optic light carriers are designed for transient use in invasive procedures through a body orifice. Telescope guide sheaths, telescopic bridges Telescope guide sheaths are used for fixing rigid telescopes and guiding flexible instruments or additional instruments in bronchoscopy and esophagoscopy. Telescope guide sheaths are designed for transient use in invasive procedures through a body orifice. Suction nozzles Suction nozzles are used for suctioning off fluids through the rigid bronchoscope in bronchoscopy. Suction nozzles are non-invasive and meant for transient use in invasive procedures through a body orifice. Respirator adapters, respirator attachments Respirator adapters are used to connect the opening at the rigid bronchoscope or tracheoscope with the tube of the respirator in rigid bronchoscopy. Respirator adapters are non-invasive and meant for transient use in invasive procedures through a body orifice.
2.2 Indications Rigid bronchoscopy is considered indicated if it is indicated in the opinion of the responsible physician.
Instructions for use • Accessories for bronchoscope and tracheoscope • UTW506_EN_V1.0_02-2021_IFU_CEMDR
6
Normal use
2.3 Contraindications The use of the bronchoscopes is contraindicated if, in the opinion of the attending physician, the surgical method as such is contraindicated or if the patient is not able to undergo surgery or anesthesia due to his or her general condition. Bronchoscopes must not be used for procedures in direct contact with the central nervous system (CNS) and central cardiovascular system. The following contraindications also apply: Absolute contraindications: –
Untreatable, life-threatening arrhythmia
–
Non-correctable coagulopathy
–
Submaximal oxygenation of the patient before the procedure
–
Acute global respiratory insufficiency (except if patient is already intubated and being ventilated)
Relative contraindications: –
Development of hypoxemia refractory to therapy
–
Coagulation disorder
–
Current anticoagulant therapy
–
Pulmonary hypertension
–
Bronchial hyperresponsiveness
–
Circumstances that give rise to the expectation that the patient may be placed at particular risk by bronchoscopy, such as imminent pneumothorax
Rigid bronchoscopy is also considered contraindicated if intubation by a rigid bronchoscope is impossible due to abnormalities in the patient’s maxillofacial or laryngeal area.
2.4 Target user populations The medical device may only be used by doctors and medical assistants with a relevant specialist qualification.
2.5 Patient groups There are no restrictions in terms of patient groups for this product.
Instructions for use • Accessories for bronchoscope and tracheoscope • UTW506_EN_V1.0_02-2021_IFU_CEMDR
7
Safety
3 Safety 3.1 Serious incidents According to the Medical Device Regulation (MDR), a “serious incident” includes incidents that directly or indirectly had, could have had, or could have any of the following consequences (MDR, Art. 2, No. 65 [1]): –
Death of a patient, user, or another person
–
Temporary or permanent serious deterioration in the medical condition of a patient, user, or another person
–
A serious threat to public health The manufacturer and appropriate authority must be notified of all serious incidents.
3.2 Unsterile product The product is not sterile when delivered. The use of non-sterile products poses a risk of infection for patients, users, and third parties. Reprocess the product in line with the reprocessing instructions before initial use and every subsequent use.
3.3 Correct handling If the product is not handled correctly, patients, users, and third parties may be injured. Only persons with the necessary medical qualification and who are acquainted with the application of the product may work with it. Check that the product is suitable for the procedure prior to use. Check the product for the following points before and after every use: –
Completeness
–
Good working order
–
Rough surfaces left inadvertently
–
Sharp corners
–
Burred edges
–
Correct assembly of the components
–
Functionality Do not leave broken-off components inside the patient. Do not overload the product with mechanical stress. Do not bend bent products back to their original position.
3.4 Damaged products Damaged products can result in injury to patients, users, or third parties. Before each use, check all components of the product for damage. Do not use damaged products.
3.5 Creutzfeldt-Jakob disease Products that come into contact with the central nervous system can become contaminated by organic residue containing prions. Prions lead to infection with Creutzfeldt-Jakob disease. If Creutzfeld-Jakob disease has been diagnosed or is suspected:
Instructions for use • Accessories for bronchoscope and tracheoscope • UTW506_EN_V1.0_02-2021_IFU_CEMDR
8
Safety
Dispose of the product properly and do not continue to use it.
3.6 Hot components The high level of light intensity produced by the light source may cause the distal end, the light connections, and adjacent components to heat up. This can cause burns to patients, users, and third parties. Set the light source output to a level that is just high enough to ensure optimal illumination of the operating area. Avoid contact with the distal end and light connections.
3.7 High light intensity The high level of light intensity produced by the light source may lead to permanent eye damage or blindness, and may cause tissue and items facing the light output to heat up. Do not look into the light output. Set the light source output to a level that is just high enough to ensure optimal illumination of the operating area. Make sure the light output is sufficiently far away from tissue and operating accessories.
3.8 Patient leakage current Patient leakage currents from products may add up if powered products and powered endotherapy devices are used simultaneously. Excessively high leakage current levels may result in the patient becoming injured. Only use products of the same type together, particularly in the case of CF products.
3.9 Disposal of pointed and sharp products If pointed and sharp products are not disposed of in suitable waste containers, there is a risk of injury and infection. Dispose of pointed and sharp products only in suitable waste containers.
3.10 Appropriate combination of endoscope and fiber optic light cable If the fiber diameter of the fiber optic light cable is too large, the endoscope light connection will heat up. This may cause damage to the endoscope. If the fiber diameter of the fiber optic light cable is too small, not enough light will enter the endoscope. This may mean that the operating area is not sufficiently illuminated. Use the endoscope with a fiber optic light cable that has an appropriate fiber diameter.
Instructions for use • Accessories for bronchoscope and tracheoscope • UTW506_EN_V1.0_02-2021_IFU_CEMDR
9
Product description
4 Product description 4.1 Product overview
Injection cannula needle (10071Y)
e.g. prismatic light deflector (10101FA)
e.g. sealing cap with window (10315M)
e.g. sealing cap with rubber seal (10315N)
e.g. FLUVOG attachment, movable (10315P)
Blind plug (10315RV)
Instructions for use • Accessories for bronchoscope and tracheoscope • UTW506_EN_V1.0_02-2021_IFU_CEMDR
10
Product description
e.g. injection cannula (10318K)
Telescopic bridge (10338R/RK/RL)
Telescopic bridge (10338LCD/LCI)
e.g. instrument guide, for suction catheter (10318S)
Respirator attachment (10316LR)
Adapter for respirator (10924D)
Adapter for respirator (10924DL)
Suction nozzle (10924SP)
Instructions for use • Accessories for bronchoscope and tracheoscope • UTW506_EN_V1.0_02-2021_IFU_CEMDR
11
Product description
4.2 Possible combinations 4.2.1 Bronchoscope for adults - light carriers/prismatic light deflectors/sealing caps/injection cannulas/adapters Bronchoscope/tracheoscope
Sealing cap
FLUVOG attachment
Injection cannula/instrument guide
Adaptor for respirator
Distal illumination
10318BK 10318CK 10318DK
10315M 10315N
10315P
10318K 10318KD 10318S
10924D 10924DL
Proximal illumination
10318BP 10318CP 10318DP 10318F 10318FL 10318G 10318ER 10318GR 10318GL 10318DPT 10318CPT 10318BPT
10314BM 10314BN
10314P
For dilation
10337R 10337S
–
–
The fiber optic light carrier for the distal illumination (10318L) and the prismatic light deflector for the proximal illumination (10101FA, 10101HA) can be used with a fiber optic light cable, dia. 2 – 2.5 mm. The blind plug (10315RV) is recommended for sealing the illumination access on bronchoscopes with proximal illumination. The vent plug (10924E) is recommended for sealing the lateral respirator channel. The respirator attachment (10316LR) is recommended for sealing the respirator channel of the dilatation tracheoscope (10337R, 10337S).
Instructions for use • Accessories for bronchoscope and tracheoscope • UTW506_EN_V1.0_02-2021_IFU_CEMDR
12
Product description
4.2.2 Bronchoscopes for children - light carriers/prismatic light deflectors/sealing caps/injection cannulas/adapters
Proximal illumination
Bronchoscope
Sealing cap
FLUVOG attachment
Injection cannula/instrument guide
Adaptor for respirators/ suction nozzles
10339AL 10339BL 10339A 10339B 10339BB 10339C 10339G 10339CD 10339CC 10339GG 10339DD 10339D
10338M 10338N
10338P
10338K 10338S
10924D 10924DL 10924SP
10339E 10339EE 10339EEE For newborns 10339F
10924SP
The child bronchoscope with the injection canula (10071Y) can be used with the instrument guide (10338S) on the lateral working channel. The prismatic light deflector (10101FA, 10101HA) can be used with a fiber optic cable, dia. 2 – 2.5 mm. The blind plug (10315RV) is recommended for sealing the illumination access on bronchoscopes with proximal illumination. The vent plug (10924E) and suction nozzle (10324SP) are recommended for sealing and for suctioning through the lateral respirator channel.
4.2.3 Child bronchoscopes with telescopic bridges and telescopes Bronchoscope
Telescope with instrument guide
10339AL 10339BL
10023ABA with 10338R
10339A 10339B 10339BB 10339C 10339G 10339CD
10324AA, 10324BA with 10338RK 10020ATA, 10020BA, 10020CA with 10338LCD
10339EEE
10324AA, 10324BA with 10338RK 10020ATA, 10020BA, 10020CA with 10338LCD
10339CC 10339GG 10339DD
10324AA, 10324BA with 10338RL 10020ATA, 10020BA, 10020CA with 10338R
10339EE
10324AA, 10324BA with 10338RL 10020ATA, 10020BA, 10020CA with 10338R
Instructions for use • Accessories for bronchoscope and tracheoscope • UTW506_EN_V1.0_02-2021_IFU_CEMDR
13
Product description
Bronchoscope
Telescope with instrument guide
10339D
10018AA, 10018BA with 10338LCD
10339E
10018AA, 10018BA with 10338LCD
10339F
10017AA with 10338LCD 10018AA, 10018BA with 10338LCD 10040AA with 10338LCI
4.3 Symbols on the packaging Symbol
Meaning Manufacturer
Date of manufacture
Medical device
Article no.
Batch code
Number of products in the product packaging
Unique Device Identifier
Consult instructions for use
Unsterile
Fragile, handle with care
Federal (USA) law restricts this device to sale by or on the order of a physician. CE marking With this mark, the manufacturer declares the compliance of the devices with the applicable standards and directives The device must not be modified in any way
Instructions for use • Accessories for bronchoscope and tracheoscope • UTW506_EN_V1.0_02-2021_IFU_CEMDR
14
Product description
4.4 Ambient conditions There are no special transport and storage conditions for this product.
Instructions for use • Accessories for bronchoscope and tracheoscope • UTW506_EN_V1.0_02-2021_IFU_CEMDR
15
Maintenance, servicing, repairs, and disposal
5 Maintenance, servicing, repairs, and disposal 5.1 Maintaining the product If they are not described in more detail here, maintenance activities may only be performed by KARL STORZ or by a company authorized by KARL STORZ.
5.2 Repairs to the product Repair work may only be performed by KARL STORZ or by a company authorized by KARL STORZ. Please contact your local KARL STORZ subsidiary or authorized dealer (see the list of subsidiaries). Contaminated devices may not be shipped. To prevent contact infections and airborne infections, products must first be decontaminated. KARL STORZ reserves the right to send back contaminated products.
5.3 Disposing of the product For disposal, the following measures are necessary: 1.
Decontaminate the products prior to disposal.
2.
Country-specific national laws and regulations must be observed.
Instructions for use • Accessories for bronchoscope and tracheoscope • UTW506_EN_V1.0_02-2021_IFU_CEMDR
16
Accessories and spare parts
6 Accessories and spare parts 6.1 Accessories Item
Order no.
Fiber optic light cable, length 180 mm, diameter 2.5 cm
495NT
Fiber optic light cable, length 230 mm, dia. 2.5 cm
495NTA
6.2 Spare parts Item
Order no.
Plug-in base, 9 mm in diameter, for Wolf fiberoptic light cables
495F
Screw base for KARL STORZ fiberoptic light cables and Olympus Corporation
495G
Article
Order no.
Sealing cap
6127390
Article
Order no.
Sealing cap, dia. 3.5
6127490
Instructions for use • Accessories for bronchoscope and tracheoscope • UTW506_EN_V1.0_02-2021_IFU_CEMDR
17
Subsidiaries
7 Subsidiaries KARL STORZ SE & Co. KG Dr.-Karl-Storz-Straße 34, 78532 Tuttlingen/Germany Postfach 230, 78503 Tuttlingen/Germany Phone: +49 7461 708-0 , Fax: +49 7461 708-105 Email: [email protected]
KARL STORZ SE & Co. KG Representation Office Kęstučio st. 59 / Lenktoji st. 27, 08124 Vilnius, Lithuania Phone: +370 5 272 0448, Mobile: +370 685 67 000 Email: [email protected]
KARL STORZ Endoskope Berlin GmbH Scharnhorststr. 3, 10115 Berlin/Germany Phone: +49 30 3069090, Fax: +49 30 30 19452
KARL STORZ Endoskopi Danmark A/S Skovlytoften 33, 2840 Holte, Denmark Phone: +45 45162600, Fax: +45 45162609 Email: [email protected]
KARL STORZ Endoscopy Canada Ltd. 7171 Millcreek Drive, Mississauga, Ontario L5N 3R3 Canada Phone: +1 905 816-4500, Fax: +1 905 816-4599 Toll free (Canada only) Phone: 1-800-268-4880, Fax: 1-800-482-4198 (Canada only) Email: [email protected] KARL STORZ Endoscopy-America, Inc. 2151 East Grand Avenue, El Segundo, CA 90245-5017, USA Phone: +1 424 218-8100, Fax: +1 424 218-8525 Toll free (USA only) Phone: 800 421-0837, Fax: 800 321-1304 (USA only) Email: [email protected] KARL STORZ Veterinary Endoscopy-America, Inc. 1 South Los Carneros Road, Goleta, CA 93117, USA Phone: +1 805 968-7776, Fax: +1 805 685-2588 Email: [email protected] KARL STORZ Endoscopia Latino-America, Inc. 815 N. W. 57th Avenue, Suite 480, Miami, FL 33126-2042, USA Phone: +1 305 262-8980, Fax: +1 305 262-8986 Email: [email protected] KARL STORZ Endoscopia México S.A. de C.V. Edificio Atlantic, Oficina 3G, Calle D e/ 1ra y 3ra, 10400 Vedado, Havanna, Cuba Phone: +537 836 95 06, Fax: +537 836 97 76 Email: [email protected] KARL STORZ Endoscopia México S.A. de C.V. Av. Ejercito Nacional No. 453 Piso 2, Colonia Granada, Alcaldia Miguel Hidalgo, C.P. 11520 Ciudad de México Phone: +52 (55) 1101 1520 Email: [email protected] KARL STORZ Marketing América Do Sul Ltda. Rua Joaquim Floriano, nº. 413, 20º andar – Itaim Bibi, CEP-04534-011 São Paulo, Brasil Phone: +55 11 3526-4600, Fax: +55 11 3526-4680 Email: [email protected] KARL STORZ Endoscopia Argentina S.A. Zufriategui 627 6° Piso, B1638 CAA - Vicente Lopez, Provincia de Buenos Aires, Argentina Phone: +54 11 4718 0919, Fax: +54 11 4718 2773 Email: [email protected] KARL STORZ Endoskopi Norge AS Stamveien1, 1483 Hagan, Norway Phone: +47 6380 5600, Fax: +47 6380 5601 Email: [email protected] KARL STORZ Endoskop Sverige AB Storsätragränd 14, 127 39 Skärholmen, Sweden Phone: +46 8 505 648 00 Email: [email protected] KARL STORZ Endoscopy Suomi OY Taivaltie 5, 01610 Vantaa, Finland Phone: +358 (0)96824774, Fax: +358 (0)968247755 Email: [email protected]
KARL STORZ Endoscopy (UK) Ltd. 415 Perth Avenue, Slough, Berkshire, SL1 4TQ, United Kingdom Phone: +44 1753 503500, Fax: +44 1753 578124 Email: [email protected] KARL STORZ Endoscopie Nederland B. V. Displayweg 2, 3821 BT Amersfoort, Netherlands Phone: +31 (0)33 4545890 Email: [email protected] KARL STORZ Endoscopy Belgium N. V. Phone: +31 (0)33 4545890 Email: [email protected] KARL STORZ Endoscopie France S. A. S. 12, rue Georges Guynemer, Quartier de l’Europe, 78280 Guyancourt, France Phone: +33 1 30484200, Fax: +33 1 30484201 Email: [email protected] KARL STORZ Endoskop Austria GmbH Landstraßer Hauptstr. 148/1/G1, 1030 Wien, Austria Phone: +43 1 71 56 0470, Fax: +43 1 71 56 0479 Email: [email protected] KARL STORZ Endoscopia Ibérica S. A. Parque Empresarial San Fernando, Edificio Munich – Planta Baja, 28830 Madrid, Spain Phone: +34 91 6771051, Fax: +34 91 6772981 Email: [email protected] KARL STORZ Endoscopia Italia S. r. l. Via dell’Artigianato, 3, 37135 Verona, Italy Phone: +39 045 8222000, Fax: +39 045 8222001 Email: [email protected] KARL STORZ Croatia d.o.o. Capraška 6, 10000 Zagreb, Croatia Phone: +385 1 6406 070, Fax: +385 1 6406 077 Email: [email protected] KARL STORZ Endoskopija d.o.o. Cesta v Gorice 34b, 1000 Ljubljana, Slovenia Phone: +386 1 620 5880, Fax: + 386 1 620 5882 Email: [email protected] KARL STORZ Polska Sp. z o.o. ul. Bojkowska 47, 44-100 Gliwice, Poland Phone: +48 32 706 13 00, Fax: +48 32 706 13 07 Email: [email protected] KARL STORZ Endoszkóp Magyarország Kft. Toberek utca 2. fsz. 17/b, HU-1112 Budapest, Hungary Phone: +36 195 096 31, Fax: +36 195 096 31 Email: [email protected] KARL STORZ Endoscopia Romania srl Str. Prof. Dr. Anton Colorian, nr. 74, Sector 4, 041393 Bukarest, Romania Phone: +40 (0)31 4250800, Fax: +40 (0)31 4250801 Email: [email protected] KARL STORZ Endoskope Greece M.E.P.E.* Patriarhou Grigoriou E’ 34, 54248 Thessaloniki, Greece Phone: +30 2310 304868, Fax: +30 2310 304862 Email: [email protected] *Repair & Service Subsidiary
Instructions for use • Accessories for bronchoscope and tracheoscope • UTW506_EN_V1.0_02-2021_IFU_CEMDR
18
Subsidiaries
KARL STORZ Industrial** Gedik Is Merkezi B Blok, Kat 5, D 38-39, Bagdat Cad. No: 162, Maltepe Istanbul, Turkey Phone: +90 216 442 9500, Fax: +90 216 442 9030 **Sales for Industrial Endoscopy
KARL STORZ Endoscopy (Shanghai) Ltd., Chengdu Branch Room 803-805, 8F Jin Jiang International Building, No. 1 West Linjiang Road, Wuhou District, 6100414, Chengdu, People’s Republic of China Phone: +86 28 86587977, Fax: +86 28 86587975 Email: [email protected]
OOO KARL STORZ Endoskopy – WOSTOK Derbenyevskaya nab. 7, building 4, 115114 Moscow, Russia Phone: +7 495 983 02 40, Fax: +7 495 983 02 41 Email: [email protected]
KARL STORZ Endoscopy (Shanghai) Ltd., Shenyang Branch Room 2001-2005, 20F N-MEDIA International Center, No. 167 Youth Avenue, Shenhe District, 110014, Shenyang, People‘s Republic of China Phone: +86 24 23181118, Fax: +86 24 23181119 Email: [email protected]
TOV LLC KARL STORZ Ukraine Avenue Geroyiv Stalingrada Str. 2D, office 717 Kyiv, 04210/Ukraine Phone: +38 095 000-895-0, +38-097-000-895-0, +38 073 000-895-0 Email: [email protected] KARL STORZ SE & Co. KG Representation Office Sabit Orudschow 1184, apt. 23, 1025 Baku, Azerbaijan Phone: +99 450 613 30 60 Email: [email protected] KARL STORZ ENDOSKOPE – East Mediterranean and Gulf (Offshore) S.A.L. Spark Tower 1st floor Charles Helou St., Horch Tabet – Sin El Fil, Beirut, Lebanon Phone: +961 1 501105, Fax: +961 1 501950 Email: [email protected] KARL STORZ Endoscopy (South Africa) (Pty) Ltd. P.O. 6061, Roggebaai, 8012 Cape Town, South Africa Phone: +27 21 417 2600, Fax: +27 21 421 5103 Email: [email protected] TOO KARL STORZ Endoskopy Kasachstan Saryarka, 6, BC “Arman“, off. 910, 010000 Astana, Republic of Kazakhstan Phone: +7 7172 552-549, 552-788, Fax: -444 Email: [email protected] KARL STORZ ENDOSKOPE East Mediterranean & Gulf (branch) Building West Side 7A – Unit 7WA – 3008, Dubai Airport Free Zone, P.O. Box 54983, Dubai - United Arab Emirates Phone: +971 (0)4 2958887, Fax: +971 (0)4 3205282 Service Hotline: +971 (0)4 3415882 Email: [email protected] KARL STORZ Endoscopy India Private Limited 11th Floor, Dr. Gopal Das Bhawan, 28, Barakhamba Road, New Delhi 110001, India Phone: +91 11 4374 3000, Fax: +91 11 4374 3010 Email: [email protected] KARL STORZ SE & CO. KG Interchange 21 Tower, Level 33, 399 Sukhumvit Road, North Klongtoey, Wattana, 10110 Bangkok, Thailand Phone: +84 28 3823 8000 Fax: +84 28 3823 8039 Email: [email protected] KARL STORZ SE & Co. KG Resident Representative Office 14th Floor, MPlaza Saigon, 39 Le Duan, District 1, Ho Chi Minh City, Vietnam Phone: +84 28 3823 8000, Fax: +84 28 3823 8039 Email: [email protected] KARL STORZ Endoscopy China Ltd. Room 2503-05, 25F AXA Tower, Landmark East, No. 100 How Ming Street, Kwun Tong, Kowloon, Hong Kong, People’s Republic of China Phone: +852 28 65 2411, Fax: +852 28 65 4114 Email: [email protected]
KARL STORZ Endoscopy (Shanghai) Ltd., Guangzhou Branch Room 02B & 03 & 04A, 35F Teem Tower, No. 208 Tianhe Road, Tianhe District, 510620, Guangzhou, People’s Republic of China Phone: +86 20 87321281, Fax: +86 20 87321286 Email: [email protected] KARL STORZ Endoscopy Asia Marketing Pte Ltd. No. 8 Commonwealth Lane #03-02, Singapore 149555, Singapore Phone: +65 69229150, Fax: +65 69229155 Email: [email protected] KARL STORZ Endoscopy Singapore Sales Pte Ltd No. 8 Commonwealth Lane #03-02, Singapore 149555, Singapore Phone: +65 69229150, Fax: +65 69229155 Email: [email protected] KARL STORZ SE & Co. KG Representative Office Indonesia Sinarmas MSIG Tower Level 37, Jl. Jend. Surdirman No. Kav. 21, Jakarta Selatan DKI Jakarta 12920 Email: [email protected] KARL STORZ Endoscopy Korea Co. Ltd. 9F Hyowon-Building, 97, Jungdae-ro, Songpa-gu, 05719 Seoul, Korea Phone: +82-70-4350-7474, Fax: +82-70-8277-3299 Email: [email protected] KARL STORZ Endoscopy Taiwan Ltd. 12F, No. 192, Sec. 2, Chung Hsin Rd., Sindian District, New Taipei City, Taiwan Phone: +886 933 014 160, Fax: +886 2 8672 6399 Email: [email protected] KARL STORZ SE & Co. KG Representative Office Philippines 1901 Picadilly Star Bldg., 4th Avenue, BGC, Taguig City 1636, Philippines Phone: +63 2 317 45 00, Fax: +63 2 317 45 11 Email: [email protected] KARL STORZ Endoscopy Japan K. K. Stage Bldg. 8F, 2-7-2 Fujimi, Chiyoda-ku, Tokyo 102-0071, Japan Phone: +81 3 6380-8622, Fax: +81 3 6380-8633 Email: [email protected] KARL STORZ Endoscopy Australia Pty. Ltd . 68 Waterloo Road, Macquarie Park NSW 2113, P O Box 50 Lane Cove NSW 1595, Australia Phone: +61 (0)2 9490 6700, Fax: +61 (0)2 9420 0695 Toll free: 1800 996 562 (Australia only) Email: [email protected] www.karlstorz.com
KARL STORZ Endoscopy (Shanghai) Ltd., Beijing Branch Room 1805-1807, Building B, 18F Beijing IFC, No. 8, Jianguomenwai Street, Chaoyang District, 100022, Beijing, People’s Republic of China Phone: +86 10 5638188, Fax: +86 10 5638199 Email: [email protected] KARL STORZ Endoscopy (Shanghai) Ltd., Shanghai Branch Room 701A Building 5 & Room 501 Building 7, No. 3000 Longdong Avenue, Pilot Free Trade Zone, 201203, Shanghai, People’s Republic of China Phone: +86 21 60339888, Fax: +86 21 60339808 Email: [email protected]
Instructions for use • Accessories for bronchoscope and tracheoscope • UTW506_EN_V1.0_02-2021_IFU_CEMDR
19