DoradoKT Service Manual Classic, Uni and Workstation Cart Ver 1.0 July 2011
Service Manual
45 Pages
Preview
Page 1
LABORIE
Dorado KT™ Service Manual
Classic Cart Uni-Cart Workstation Cart
USA 400 Avenue D, Suite 10 Williston, Vermont, USA 05495 Sales/Marketing: 802.857.1300 Customer Service: 800.522.6743 Technical Support: 800.333.1039 Fax: 802.878.1122 [email protected]
CANADA 2101 Boul. Lapinière Brossard, Québec, Canada J4W 1L7 Montreal: 450.671.5901 Customer Service: 888.522.6743 Technical Support: 800.333.1039 Fax: 450.671.7182 [email protected]
EUROPE (E.U. REP) Unit 5, Garonor Way Royal Portbury, Bristol, UK BS20 7XE 1X1 Tel.: +44 (0) 1275 372332 Fax: +44 (0) 1275 375145 [email protected]
INTERNATIONAL 6415 Northwest Dr., Unit 10 Mississauga, Ontario, Canada L4V Customer Service: 905.612.1170 Fax: 905.612.9731 [email protected]
www.laborie.com
Dorado KT is a trademark of LABORIE (also known as Laborie Medical Technologies). Unisensor is a trademark of UNISENSOR AG. Norton is a trademark of Symantec Corporation or its affiliates in the U.S. and other countries. ITD is a trademark of ITD GmbH. Other names may be trademarks of their respective owners. © Copyright 2011 by LABORIE. All rights reserved. No part of this publication may be reproduced in any form whatsoever without the prior written permission of LABORIE.
Document Number: DORKT-SM02 Version Number: 1.0 Release Date: July 18, 2011
MAN584
Table of Contents 1
INTRODUCTION... 1
2
SYSTEM OVERVIEW ... 2
3
TECHNICAL DESCRIPTION ... 3 3.1 3.2 3.3 3.4 3.5 3.6 3.7
4
TRANSDUCER SETUP AND CONNECTION ... 12 4.1 4.2 4.2.1
4.3 4.4 4.5
5
5.6.1 5.6.2 5.6.3
5.7
6.5.1 6.5.2 6.5.3
6.6
7.2.1
For water-based disposable catheter systems... 23 For air-charged catheter systems ... 24 For Electronic Catheter Systems ... 25
Calibrate the Infusion Transducer (P8) ... 26
Equipment and Accessories ... 28 Preventive Maintenance ... 28 Virus Protection ... 29 Air-charged (T-DOC) Transducer/Cable Cleaning Instructions ... 29 Electronic (Unisensor™) Solid-State Catheters ... 29 Catheter Cleaning ... 30 Disinfection ... 30 Sterilization ... 30
Treating and Disposing of Product After Use ... 31
Symptoms/Causes/Corrective Actions ... 32 EMG Verification... 35 Corrective Actions ... 35
ELECTROMAGNETIC COMPATIBILITY (EMC) ... 37 8.1 8.2
9
Calibrate Volume ... 19 Calibrate Flow... 20 Calibrate the EMG Unit (optional) ... 21 Calibrate the UPP Puller (optional) ... 21 Calibrate the Pump ... 22 Calibrate Pressure Transducers (P1, P2, P3, etc…) ... 23
TROUBLESHOOTING ... 32 7.1 7.2
8
Fluid-Filled Pressure Transducer Connections ... 13
Electronic Catheter ... 14 Infusion Volume Transducer ... 15 EMG Setup ... 17
CLEANING AND PREVENTIVE MAINTENANCE... 28 6.1 6.2 6.3 6.4 6.5
7
Uroflow Transducer ... 12 Fluid-Filled Pressure Transducer Setup ... 13
TRANSDUCER CALIBRATION ... 19 5.1 5.2 5.3 5.4 5.5 5.6
6
System Specifications... 3 Classifications... 3 Operating Ranges and Accuracy ... 3 Applicable Directives and Standards ... 4 Replacement Accessories ... 4 Peripheral Specifications ... 5 Optional Software Features ... 10
Emissions ... 37 Immunity ... 37
SYMBOLS ... 39
10 SCHEMATICS - PROPRIETARY INFORMATION ... 40 11 END-USER SOFTWARE LICENSE AGREEMENT... 41
LABORIE
Classic Cart/Uni-cart/ Workstation Cart
Dorado KT™ Service Manual
1 INTRODUCTION This manual is intended for servicing the Dorado KT™ UDS system manufactured by LABORIE. The UDS94 on the Dorado KT is a data acquisition unit. It collects data from the following devices:
Uroflow Transducer Water Pressure Transducers UPP Puller Electronic Pressure Transducers Infusion Transducer EMG Unit
The information located in this manual is intended for the biomedical departments of hospitals or clinics.
Page 1
LABORIE
Dorado KT™ Service Manual
Classic Cart/Uni-cart/ Workstation Cart
2 SYSTEM OVERVIEW
External Devices and Transducers
Printer
Dorado KT02 Interface
Keyboard VGA Monitor
CPU (Motherboard) Mouse
Hard Drive CD-ROM
Page 2
Floppy Drive A
LABORIE
Classic Cart/Uni-cart/ Workstation Cart
Dorado KT™ Service Manual
3 TECHNICAL DESCRIPTION UPON REQUEST, LABORIE will make available to the customer any circuit diagrams, component part lists, and other technical documentation directly related to the Dorado KT.
3.1 System Specifications Model: Dorado KT™ Dimensions: 22” x 25”(Footprint) X 53”(Cart Height) 56cm x 64cm (Footprint) X 135 cm (Cart Height) Weight: 18.2 kg (40 lb) including power supply Model: ITD Uni-Cart/Workstation Cart Dimensions: 540mm x 580mm (Footprint) X 1145mm (Cart Height) Weight: 65 kg Model: ITD Classic Cart Dimensions: 614/714mm x 625mm (Footprint) X 1117mm (Cart Height) Weight: 150 kg Electrical Input Ratings: 230V~, 50Hz ,3.0A Operating Conditions
Temperature: 15ºC to 35ºC (59ºF to 95ºF) Humidity: 30% to 75% relative humidity (non-condensing) Pressure: 700hPa to 1014hPa
Transport and Storage Conditions
Temperature: -10ºC to 50ºC (14ºF to 122ºF) Humidity: 20% to 80% relative humidity (non-condensing) Pressure: 700hPa to 1014hPa
3.2 Classifications IEC 60601-1 Degree of Protection Against Ingress of Water Mode of Operation
Class I Equipment Type BF Applied Parts IPX0 Equipment Continuous Equipment not suitable for use in the presence of a Flammable Anaesthetic Mixture with Air or Oxygen or Nitrous Oxide.
3.3 Operating Ranges and Accuracy Uroflow Rate Uroflow Volume Pressure
0 to 50 ml/s 0 to 1000 ml -30 to 350 cm H2O
Page 3
LABORIE
Classic Cart/Uni-cart/ Workstation Cart
EMG† Pump UPP Puller (optional) Infusion T-Doc Data Conversion Rate
Dorado KT™ Service Manual
0 to 225 µV Frequency: 20 to 800 Hz 5 to 140 ml/min * 0.5 to 3 mm/s 0 to 1000 ml -68 to 408 cmH2O Min 10 Hz (min) up to 1000 Hz (optional up to 5000 Hz)
* Maximum pump rate is limited by size of catheter used † Sensitivity Range: +/- 1000 µV; High Pass: 800 Hz; Low Pass: 20 Hz
3.4
Applicable Directives and Standards Directive: MDD Directive 93/42/EEC Standards: IEC 60601-1 IEC 60601-1-1 IEC 60601-1-2 IEC 60601-1-4 EN 60601-1 CSA 22.2 No.601.1-M90 UL 60601-1
3.5
Replacement Accessories
Accessory Laborie family of conventional single-use Urodynamic catheters (6fr – 14fr) Laborie family of electronic catheters Laborie family of single use air-charged catheters Pump Tubing set with Infusion Line Urodynamics Measurement Tubing Set Pressure Transducer with Luer Lock Beaker USB Printer Cable for Desktop Printer Accessory Dual Lumen 6 Fr. Catheter or 8 Fr. Catheter Urodynamics Measurement Tubing Set Pump Tubing set with Infusion Line
Page 4
Number Model varies Model varies Model varies TUB500 TUB101 DIS130 DIS173 CAB914 Number CAT206 or CAT208 TUB101 TUB500
LABORIE
Classic Cart/Uni-cart/ Workstation Cart
Dorado KT™ Service Manual
3.6 Peripheral Specifications ITD Cart
Part Number: CAR441/CAR442 Materials: Aluminum, Steel, Sheet Steel, Plastic Size {W x D x H}: 540 x 580 x 1145 mm Weight: 65kg Relevant Standards: IEC60601-1, IEC60601-1-1, IEC60601-1-2, EN60601-1, UL2601-1 Agency: TUV
Uni-Cart/Workstation Cart Part Number: CAR443/CAR444/CAR446 Materials: Aluminum, Steel, Sheet Steel, Plastic Size {W x D x H}: 614/714 x 625 x 1117 mm Weight: 150kg Relevant Standards: IEC60601-1, IEC60601-1-1, IEC60601-1-2, EN60601-1, UL2601-1 Agency: TUV
Classic Cart
Monitor Mounts
Part Number: HAR533 Materials: Sheet Steel, Aluminum Load Rating: Maximum up to 8kg
single mount
Part Number: HAR939, HAR535 Materials: Sheet Steel Load Rating: Maximum up to 10kg
dual mount
Page 5
LABORIE
Classic Cart/Uni-cart/ Workstation Cart
Uroflow: Differential Input EMG: Direct Signal P1/2: Dual Differential Input P3/4: Dual Differential Input Port D: RS232 (adj. settings) Port A: Main RS232 (default 115200, 8, 0, 1, NFC) USB: USB1.1 (used for firmware download, not interface active) Port B: Printer RS232 (default 38400, 8, 0, 1, HWC) Port C: RS232 (adj. settings) UPP: 2 Digital I/O, Speed Control signal Main Power: +12VDC, 5A input
Dorado KT I/O
Part Number: POW779 Size {W x D x H}: 129 x 77 x 40 mm, Size {Length}: 1,735 mm Weight: 488 grams Materials: Black, 94VO Polycarbonate Power In: 100-240Vac, 50-60 Hz, 1A Power Out: +12 Vdc, 6.67A
Power Supply
Instruction Manual and Service Manual
LABORIE Software
Dorado KT™ Service Manual
Part Number: MAN583 and MAN584 Size {W x D}: 210 x 297 mm Material: PDF
Part Number: LAB783/LAB786 Label Information: Laborie CD Size {Diameter}: 11.9mm Weight: 12 grams CD Software: UDS View, Manuals, Instruction Video, Brochure
UDS Transducers Uroflow Transducer
Part Number: TRA875 Size {Dia x H}: 126 x 112 mm Weight:1068 grams Materials: Aluminum, PVC, nickel plate steel, Acetal Voltage excitation: +/-3.3V Serial Number Format: FUAyyxxxx
Page 6
LABORIE
Classic Cart/Uni-cart/ Workstation Cart
Pressure Transducer Plate
Pressure Cable
EMG Processor & Head Stage
Integrated Pump
Dorado KT™ Service Manual
Part Number: TRA600(P1)/TRA602(P2)/TRA604(P3)/TRA608(P5)/ TRA610(P6)/ TRA612(P7) Size {W x D x H}: 57 x 24 x 73 mm Weight: 34 grams Voltage excitation: +/-3.3V Serial Number Format: MX960xxxxx Part Number: CAB440(P1/P2)/CAB441(P3)/ CAB444(P5/P6)/CAB443(P7) Size {Length}: 810…890 mm Weight: 68 grams Materials: ABS, Nickel Plate Steel, PVC Serial Number Format: None
Part Number: CAB155 Size {Length}: 1800 mm Weight: 38 grams Materials: ABS Voltage excitation: +/- 5V Serial Number Format: None
Part Number: Integrated into PRO493 Size (W x D x H): 83.97 x 48.42 x 81.10 mm Weight: 320 grams Materials: Polypropylene, IXEF, Nylon, Stainless Steel Serial Number Format: Integrated into 94-R01
Note: Upper limit is dependent on catheter used.
UPP
Part Number: UPP 715 Size base (Dia x H): 680 x 500mm Size arm (Length): 1000 mm Size puller (W x D x H): 44 x 50 x 77 mm Weight: 1500 grams Materials: Aluminum, Acetal, PVC, Steel Voltage excitation:+12V Serial Number Format: UPByymmzzzz
Page 7
LABORIE
Classic Cart/Uni-cart/ Workstation Cart
Electronic Catheter (Single)
Dorado KT™ Service Manual
Part Number: Not Released Size (Length): 10 ft 4 in Weight: 88 grams Materials: Chromium Steel, Polyurethane, Teflon, Silicon Encapsulation Voltage excitation: +/-3.3V Serial Number Format: None
T-DOC
Part Number: CAB665(P1/P2) / CAB666(P3) Size {W x D x H}: 57 x 24 x 73 mm Weight: 183 grams Voltage excitation: +/-3.3V Serial Number Format: TDCxxxxx
Infusion Transducer
Part Number: TRA145 Size (Length): 145 mm Weight: 9 grams Materials: Acetal, Aluminum, Stainless Steel Voltage Excitation: 10V max Serial Number Format: INFyymmzzzz
Laborie Accessories 115V Medical Grade Power Cord
110V Part Number: POW005 Size (Length): 2400 mm Weight: 272 grams Materials: PVC 230V Part Number: POW740 Size (Length): 2490 mm Weight: 266 grams Materials: PVC
Page 8
LABORIE
Classic Cart/Uni-cart/ Workstation Cart
Dorado KT™ Service Manual
Commode Chair
Part Number: CHA171 Size (W x D x H): 432mm x 610mm x 480mm Weight: 6.14 Kg Materials: White PVC tubing Maximum Weight Allowed: 136.4 Kg
Flow Stand
Part Number: STA700 Size (W x D x H): 406mm x 381mm x 559mm Material: Aluminum, Stainless Steel, Acetal Weight: 1.4 Kg
Laborie Disposables Laborie Transducer Cartridge with Luer Lock
Part Number: DIS130 Size (W x D x H): 28.37 x 10.12 x 50.44 mm Weight: 6 grams Materials: Diaphragm: Black Polyurethane DPS Cartridge: Polycarbonate Silicone lubricant: Dow #360 silicone lubricant Protector: White Acrylonitrile Butadiene Styrene ISO Lock Nut: Acrylic ISO Lock Nut Adapter: Polycarbonate Protectors: Low Density Polyethylene
To be used with Logical Pressure Plate Transducers (UDS-D-M-Px).
Urodynamics Measurement Tubing Set
Part Number: TUB101 Weight: 22 grams Materials: Protector: LDPE DOW 640 NT; Stopcock plug: HDPE Quantum LF 6030-00 & DuPont 50006 White Stopcock body: Polycarbonate GE Lexan 144R-112 Tubing: 125 C Kentak 3390 NT Male and female Luer: Polycarbonate GE Lexan 144R112
To be used with Logical Pressure Transducers Plate (UDS-D-M-Px)
Page 9
LABORIE
Classic Cart/Uni-cart/ Workstation Cart
Dorado KT™ Service Manual
Part Number: TUB500 Weight: 54 grams Materials: PVC Plastic Female Luer taper: C1500-01 Tubing Clamp: C1502-01 Silicone tubing: C1501-01 Male Luer: Polycarbonate GE Lexan 144R-112 Male and female protector: LDPE DOW 640INT Stopcock plug: HDPE Quantum LF 6030-00 & DuPont 50006 White Stopcock body: Polycarbonate GE Lexan 144R-112
Pump Tubing Set with Infusion Line
To be used with Logical Pressure Transducers Plate (UDS-D-M-Px)
3.7 Optional Software Features Feature Batch Printing Adjustable Data Rate Math 1 to Math 4 Adjustable Display Curve Width Adjustable Printing Curve Width User-Defined Curve Color User-Defined Curve Filling User-Defined Curve Mirror User-Defined Curve Overlay User-Defined Event List Compliance Measurements Auto Compliance Eberhard Curves/Summary URA CHESS Nomogram WF LinPURR Area under curve Click channel titles and units to modify Click channel scales to modify Channel Value Marker User-defined channel font Pediatric Nomogram Data Rate Sampling (Mode I) Data Rate Sampling (Mode II) VBN Animation VBN Full Sound Uropix II Uropix Burst Uropix Smart Capture Saturn Burst
Item Number FEA125 FEA035 FEA335 FEA040 FEA045 FEA575 FEA605 FEA635 FEA650 FEA665 FEA155 FEA065 FEA255 FEA500 FEA143 FEA725 FEA305 FEA050 FEA150 FEA145 FEA140 FEA515 FEA365 FEA673 FEA669 FEA681 FEA677 FEA470 VID600 VID630 VID615 VID315
Page 10
LABORIE
Classic Cart/Uni-cart/ Workstation Cart
Feature Saturn Smart Capture Manual Capture Image Cursor Auto Capture Image Overlay Additional Viewing Key
Dorado KT™ Service Manual
Item Number VID330 FEA315 FEA290 FEA060 FEA295 FEA485
Page 11
LABORIE
Classic Cart/Uni-cart/ Workstation Cart
Dorado KT™ Service Manual
4 TRANSDUCER SETUP AND CONNECTION 4.1 Uroflow Transducer The first step in performing a test procedure using your Dorado KT is to set up the Uroflow transducer. To set up the Uroflow transducer: 1. Place the funnel on the plastic frame of the commode chair. 2. Carefully place the Uroflow transducer on the floor. 3. Gently place the Uroflow dish on top of the Uroflow transducer. 4. Place a graduated beaker on top of the dish. 5. Place the commode chair and funnel over top of the Uroflow transducer and beaker. Ensure that the beaker and the funnel are aligned. 6. Connect the Uroflow transducer cable to the flow port on the back of your Dorado KT. IMPORTANT! It is critical that:
The Uroflow dish is properly seated inside the base. Remove the protective sponge spacer if it is still separating the dish from the base.
The beaker is well centered and does not touch the funnel during the test.
a.
b.
Uroflow Transducer (a) placed under commode chair (b)
Page 12
LABORIE
Classic Cart/Uni-cart/ Workstation Cart
Dorado KT™ Service Manual
4.2 Fluid-Filled Pressure Transducer Setup Take each pressure cartridge out of its package, and remove protective covers from the back and from the connector ends. 1. Slide a cartridge over each transducer until it clicks in place. 2. Attach pressure measurement tubing, with attached three way stopcock to lower (male) end the pressure cartridge. 3. Attach 10 ml sterile-fluid filled syringe to side port of stopcock. 4. By turning stopcock in appropriate directions, flush fluid from syringe through both the pressure cartridge and the pressure measurement tubing. CAUTION! There should be NO AIR BUBBLES present in the system during testing. NOTE: Be sure that the stopper cap is always securely in place whenever the stopcock position is being changed.
Fluid-Filled Pressure Transducer Setup
4.2.1 Fluid-Filled Pressure Transducer Connections 1. Attach a 3-way stopcock with pressure measurement tubing to the bottom (male) connector of the pressure cartridge.
Page 13
LABORIE
Classic Cart/Uni-cart/ Workstation Cart
Dorado KT™ Service Manual
2. Attach the opposite end if the pressure measurement tubing to the catheter. 3. Attach a syringe filled with water or saline to the stopcock. 4. Turn the ―OFF‖ position of the stopcock down towards the catheter. (see B below) 5. Remove the Luer lock plug from the top (female) connector of the pressure cartridge. 6. Fill the pressure cartridge with water. Reattach the Luer lock plug. 7. Turn the ―OFF‖ position of the stopcock up towards the Luer lock plug (see D below). 8. Prime the pressure measurement tubing and the catheter. 9. Turn the ―OFF‖ position of the stopcock towards the syringe (see A below). The 3-way stopcock should be turned “OFF” towards the syringe to allow pressure recording (A). Off to Syringe
To Transducer Cartridge
To Catheter
Stopcock Positions
4.3
Electronic Catheter
Typical Set up 1.
Connect the cables to the Electronic catheters as follows: P1 – Pves – Blue -> S1 distal of dual catheter P2 – Pabd – Red -> Single catheter
Page 14
LABORIE
Classic Cart/Uni-cart/ Workstation Cart
Dorado KT™ Service Manual
P3 – Pura – Black -> S2 proximal of dual catheter Refer to the following diagram for more information.
Figure 4.1: Electronic Catheter Connections
4.4
Infusion Volume Transducer
1. Place the volume transducer at the top of the IV pole. (see Figure 4.2) 2. Connect the infusion transducer cable to the P8 port of the Dorado KT. 3. Place a 1000 ml bag of sterile saline inside a pressure cuff. Hang the pressure cuff on the hook of the infusion transducer. The IV pole should be at least 60 cm above the patient table. 4. Inflate the pressure cuff to 300 mm Hg (when the red line appears on the pressure cuff gage). 5. Connect an infusion line to the saline bag. Use a basic solution set with a drip chamber. 6. Tape the infusion line to the IV pole between the drip chamber and the flow control valve (roller clamp). Ensure there is excess tubing between the tape and the drip chamber.
Page 15
LABORIE
Classic Cart/Uni-cart/ Workstation Cart
Dorado KT™ Service Manual
7. Connect the other end of the infusion line to the filling port on the catheter.
Important! • Ensure that the infusion line is not pulled or else the transducer reading will not be accurate. • The infusion transducer is calibrated for up to 1000 ml of sterile saline or water. If you are using a different medium, such as hypaque, re-calibration is required. •The infusion transducer for the Dorado KT is compatible with the Aquarius TT™, Triton™, and Delphis™ systems. However, it cannot be used on the Bonito™ systems.
Hint: Use an infusion pressure cuff for faster flow rate.
Page 16