LIMAX

marClampIQ maXium

marClamp CUT IQ Reprocessing Information

2 Pages

Reprocessing Information  •  Open the instrument's handles wide (2).  •  Hold the top part of the protective housing (1) in one hand and use the other hand to grab the bottom part.  •  Now pull the top and bottom parts apart.  •  Lift the blade (3) out of the lock-in position (4) by bending it slightly upwards, and then pull it backwards and out of the instrument.  •  Dispose of the blade according to the applicable regulations.  •  Remove the blade if it has not already been removed in the operating room.  •  Immerse into cold water for 5 min.  •  Use the cleaning tools provided for this purpose to clean the slit in the electrode.  acc. to DIN EN ISO 17664 This document does not replace the instructions for use!  Designation Item number (REF)  marClamp CUT IQ 80-632-00-04 to 80-632-50-04 Danger of injury and risk of damage to the bipolar sealing instrument marClamp CUT IQ from improper handling!  WARNING  Reprocessing limitations  •  Never reprocess and/or reuse blades!  •  Do not perform any quick sterilization without a drying phase or hot air sterilization!  •  Perform a function check before sterilization and before usage!  •  The instruments may be used only with the maxium® electrosurgery unit produced by Gebrüder Martin. Hardware version HW 06 or higher is required (IQ connector = coded special connector)!  •  When changing the blade, insert it into the handle with care in order to avoid damage to the blade!  •  Do not touch any hard objects during the function check with the newly inserted blade! There is risk of damage to the blade!  Preparation for cleaning  Damage, loss of cable insulation, damaged or scratched contact surfaces with adherent residues of tissue, functional impairment due to decreasing compression force in the jaw part, loosening or wear of components. With every application, the wear of the instrument progresses. Reliable functioning of the instrument is guaranteed for the first 50 application cycles at an average usage frequency and load. Gebrüder Martin recommends replacing the instrument when this number is exceeded.  Workplace  CSSD, instrument processing department  Storage and Transport  Handle with great care. Do not drop or throw. Do not bend the cable. Do not store or transport cables together with cutting instruments. Store and transport in safe containers/packages.  Manual pre-cleaning (in preparation for machine cleaning)  Insert the accompanying cleaning brush through the blade guideway in the joint and clean by repeatedly pulling the brush back and forth. •  Brush the electrode with a suitable soft brush.  •  Brush all contaminated parts with a suitable brush while moving all the movable parts.  •  Clean in ultrasonicator for 5 min at 40°C (104°F) with 0.5% working solution of an alkaline cleaning agent.  Use of hydrogen peroxide can lead to premature wear of the instrument and thus reduce its lifetime.  Date of Release: 2016-12 · 90-016-52-10 · Printed in Germany · Copyright by Gebrüder Martin GmbH & Co. KG · Alle Rechte vorbehalten · Technische Änderungen vorbehalten · We reserve the right to make alterations · Cambios técnicos reservados · Sous réserve de modifications techniques · Ci riserviamo il diritto di modifiche tecniche · Revision: 1
File Type: PDF
File Size: 1.09 MB
File Name: KLS MARTIN - 90-016-52-10 - marClamp CUT IQ Reprocessing Information - 2016-12 - Rev 1.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions