Medartis AG
Aptus Modus Sterile Products Handling Instructions
8 Pages
Preview
Page 1
2 | Sterile Products
Contents 3
Introduction
4
Patient Label Overview
4
Sterilization Method
4
Handling Instructions
4 Prior to Use 5 Step by Step Opening of Sterile Packages 5 Opening the Outer Packaging 6 Removing the Inner Tube or Inner Pouch 7 Removing Contents of Inner Pouch or Tube 7
Screw Pick-Up
7
Recording of Lot and Implant Information
For further information regarding the Medartis product lines, please visit www.medartis.com
www.medartis.com
Sterile Products | 3
Introduction Medartis products are now also available sterilized and ready for use offering several benefits to the surgeon and the hospital. Sterilized implants eliminate: • Risks of reprocessing • Costs of cleaning and disinfecting • Cost of sterilization
Blister type packaging with labels, tubes, blister and cardboard box
Packaging Concept Medartis products are packaged in either of the two packaging types: Blister Type Packaging • Blister type sterile barrier packaging containing an injection molded, laser welded Styrene Methyl Methacrylate (SMMA) tube with metal inserts for product storage
Inner injection molded tube
• Used for screws, short K-wires and short twist drills
Pouch Type Packaging • Pouch type packaging with heat sealed PA / PE pouches • Used for plates, long K-wires, long twist drills and reamers
Pouch type packaging with labels, sealed pouches and cardboard box
www.medartis.com
4 | Sterile Products
Patient Label Overview GS1 DataMatrix code (GTIN, date of manufacture, expiration date, lot number)
2.5TriLock Dist.Rad.Fract.Pl Volar Right A-4750.02S XXXXXXXXXXXX QTY: 1 YYYY-MM-DD (01) 07630037805571 (11) YYMMDD (17) YYMMDD (10)XXXXXXXXXXXX
Product Description - English Article number
Sterilized using irradiation Consult instructions for use
1 / 0001
YYYY-MM-DD
Quantity number Lot number Date of manufacture Use by date CE mark
ML04997/A
www.medartis.com
0197
Do not reuse
(01) 07630037805571 (11) YYMMDD (17) YYMMDD (10)XXXXXXXXXXXX
2.5TriLock Dist.Rad.Fract.Pl Volar Right A-4750.02S XXXXXXXXXXXX QTY: 1 YYYY-MM-DD YYYY-MM-DD
Sterilization Method 2 / 0001
ML04997/A
www.medartis.com
0197
(01) 07630037805571 (11) YYMMDD (17) YYMMDD (10)XXXXXXXXXXXX
2.5TriLock Dist.Rad.Fract.Pl Volar Right A-4750.02S XXXXXXXXXXXX Medartis sterile plates, screws and instruments undergo an for QTY: product storage, or an outer pouch containing an inner 1 YYYY-MM-DD irradiation sterilization process. The sterile barrier packaging
pouch for enhanced handling and safe transport of the
consists of an outer sealed blister package containing a tube
product.
3 / 0001
YYYY-MM-DD
ML04997/A
www.medartis.com
0197
2.5TriLock Dist.Rad.Fract.Pl Volar Right A-4750.02S XXXXXXXXXXXX QTY: 1 YYYY-MM-DD (01) 07630037805571 (11) YYMMDD (17) YYMMDD (10)XXXXXXXXXXXX
Handling Instructions 4 / 0001
Prior to Use
YYYY-MM-DD
ML04997/A
www.medartis.com
0197
2.5TriLock Dist.Rad.Fract.Pl Volar Right A-4750.02S XXXXXXXXXXXX • Inspect and verify the physical integrity of the packaging and QTY: 1 YYYY-MM-DD do not use any product where the sterile packaging has been opened or damaged 5 / 0001
• Confirm contents are per surgeon’s request
(01) 07630037805571 (11) YYMMDD (17) YYMMDD (10)XXXXXXXXXXXX
• Check the use by date
YYYY-MM-DD
ML04997/A
www.medartis.com
0197
Notice
2.5TriLock Dist.Rad.Fract.Pl Volar Right Once the sterile packaging has been opened, the product Use by date
Devices are for single use only and may not be reused or resterilized under any circumstances. 6 / 0001
(01) 07630037805571 (11) YYMMDD (17) YYMMDD (10)XXXXXXXXXXXX
A-4750.02S
cannot be resterilized.
QTY: 1
XXXXXXXXXXXX YYYY-MM-DD YYYY-MM-DD
ML04997/A
www.medartis.com
www.medartis.com
0197
Non-sterile field
Sterile Products | 5
Step by Step Opening of Sterile Packages Example: Blister and tube combination • Sterile items should be opened aseptically following specific guidelines • Circulating nurse in the non-sterile field – Break the seal of the exterior box at the serrations and remove the contents – Position the package contents outside the sterile field on a flat dry surface – Check the physical integrity of the outer blister packaging and do not use if opened or damaged
Non-sterile field
Opening the Outer Packaging • Circulating nurse in the non-sterile field – Open the blister pack by peeling back and folding the top half to 2 / 3 of the way down – Make sure there is no contact between the opened lid and the inner rim or any part of the inner blister
Non-sterile field
www.medartis.com
6 | Sterile Products
Removing the Inner Tube or Inner Pouch Inner Tube • Circulating nurse in the non-sterile field – Hold back the peeled back lid with thumb, place trigger finger in channel of blister – Hold front and bottom of blister pack with second hand – Bend blister slowly upwards with trigger finger in channel, while holding the back of the tube with the thumb. The tube which is still covered by the sterile peeled back lid, will tilt upwards
Non-sterile field
• Scrub nurse in sterile field – Scrub nurse to remove the inner tube in the sterile field maintaining item sterility and integrity – Care must be taken that the tube does not touch any part of the packaging that is not sterile
Sterile field
Inner Pouch • Circulating nurse in the non-sterile field – Open the outer pouch with two hands and present the inner pouch to the scrub nurse in the sterile field Notice Sterile articles should never be dropped onto a sterile field as they may roll off the edge, create a hole in the sterile drape, or cause other items to be displaced, leading to contamination of the sterile field. Non-sterile field
www.medartis.com
Sterile Products | 7
• Scrub nurse in sterile field – Scrub nurse to remove the inner pouch with care ensuring there is no contact with any part of the packaging that is not sterile
Removing Contents of Inner Pouch or Tube • Scrub nurse in sterile field – Scrub nurse to open the inner pouch over the sterile field with two hands
Sterile field
– Contents of the inner pouch are to be removed and placed onto a flat surface in the sterile field
Screw Pick-Up • Scrub nurse in sterile field – Hold tube upright and open the inner tube by removing the cap – Insert screwdriver vertically into screw head of the screw in the tube and pick up the screw with axial pressure – Remove screw from the tube. If necessary, hold screw on screwdriver blade with finger
Sterile field
• Alternative method – Remove screw by gently tilting tube and sliding out contents onto the flat surface in the sterile field
Sterile field
Recording of Lot and Implant Information • Circulating nurse in the non-sterile field – Place the patient labels from the used implants in the patients file to enhance lot identification and tracking,
as well as achieve accurate hospital documentation of implant utilization
www.medartis.com
CORP-01010001_v2 / © 2020-10, Medartis AG, Switzerland. All technical data subject to alteration.
M A N U FA C T U R E R & H E A D Q U A R T E R S Medartis AG | Hochbergerstrasse 60E | 4057 Basel / Switzerland P +41 61 633 34 34 | F +41 61 633 34 00 | www.medartis.com
SUBSIDIARIES Australia | Austria | Brazil | China | France | Germany | Japan | Mexico | New Zealand | Poland | UK | USA
For detailed information regarding our subsidiaries and distributors, please visit www.medartis.com
Disclaimer: This information is intended to demonstrate the Medartis portfolio of medical devices. A surgeon must always rely on her or his own professional clinical judgement when deciding whether to use a particular product when treating a particular patient. Medartis is not giving any medical advice. The devices may not be available in all countries due to registration and / or medical practices. For further questions, please contact your Medartis representative (www.medartis.com). This information contains CE-marked products. For US only: Federal law restricts this device to sale by or on the order of a physician.