BodyGuard Infusion Pump System

BodyGuard series Quick User Guide

Quick User Guide

2 Pages

Alert & alarm activation START/OK  Displays pump infusion status & programming choices/ instructions  STOP/NO  INFO  LED Indicator:  Infusion running (green light flashes)  Alarm state/ stand-by mode (continuous red light)  CLINICIAN ACTIVATED BOLUS  ON/OFF  Scroll UP Scroll DOWN  Troubleshooting Screen  Result/Cause  Action  Air/Up Occlusion  - Air in line - Tubing clamped/kinked  - Prime/re-prime line - Clear kinked/trapped line  Down Occlusion  - Tubing clamped/kinked - Access device blocked - Line not loaded correctly  - Clear kinked/trapped line - Change/flush access device - Reload set correctly  Missing Key Stopped  - Set is loaded incorrectly, pump will not start - User trying to load a non-proprietary set - The pump has been paused/on stand-by for more than 2 minutes  - Either restart infusion, continue pause or turn power off  Technical problem/error and failure identification The pump alarms if an internal system fault has been detected and the unit will be inoperative, screen information and user prompts will vary depending on the cause of the fault. • Power the pump off and then power on again, this may rectify the problem. • If the problem cannot be rectified: Power off the pump and remove from patient use.  When an ALARM is activated:  1. The infusion stops 2. The LED indicator turns red 3. An audible alarm activates (this will continue until either the STOP/NO key is pressed to mute or the problem is rectified) 4. A screen message appears on the display indicating the cause  Result/Cause  Action  - Infusion programme is nearly complete  - Prepare new bag, if applicable  End of Infusion  - Current infusion programme is complete  - Turn the pump off or change the bag to start a new infusion  Low Battery (Alert)  - Approximately 30 minutes of battery life remaining  - Place pump in charger or use the battery cable to connect to the DC socket  End Battery (Alert)  - Pump stops  - Place pump in charger or use the battery cable to connect to the DC socket  Near End of Infusion  Follow local policy and/or contact your authorised Medical Engineering Department for advice if necessary. Press INFO key to display information on the fault, record the code number and a summary of the fault. The example shown prompts the user: Pressing the INFO key displays an error code number and a description of the error:  Changes cannot be made to the infusion with the Keypad lock activated. To change bag, change rate, to deliver CA bolus or to discontinue the infusion, keypad lock must be removed by designated users only. NOTE: In the event of an emergency, the STOP/NO and START/YES keys can still be activated with keypad lock in place.  Quick user guide  1. The infusion continues 2. Intermittent beeps are heard approximately every 3/4 minutes 3. A screen message alternates with the infusion running screen  Screen  - Load set with infusion line key positioned correctly - Ensure that a dedicated BodyGuard set is being used  Bodyguard Pain Management Pump  An ALERT is activated when there is a low battery OR near end of infusion:  CME Medical UK Ltd Kincraig Business Park, Kincraig Road, Blackpool FY2 0PJ  Epidural Infusion Pump  Pain Management Infusion Pump  Regional Analgesia Infusion Pump  CME Medical Device Training is RCN Accredited KEYPAD LOCK Changes cannot be made to the infusion with the Keypad lock activated. To change bag, change rate, to deliver CA bolus or to discontinue the infusion, keypad lock must be removed by designated users only. Please note: In the event of an emergency, the STOP/NO and START/YES keys can still be activated with keypad lock in place.  Restart Pump Switch off & on  Error 26 Starting MotMove Fail  Tel: 01253 894646 Fax: 01253 896648 info@cmemedical.co.uk www.cmemedical.co.uk  Doc ref: Pain Mgt/QUG/v5/Sept 2011  Front of pump features & keys  ACCESSING INFUSION SUMMARY During an infusion, repeatedly press the INFO to access current infusion information: • Volume infused/to be infused • Battery level • Bolus attempts / given & clinican bolus • Protocol review screen • Date & time NOTE: • Users must have undertaken training before operating this device. • Refer to Operating Manual for full operating instructions. • Screen information/sequences may vary slightly with different software versions. • The guidance given is based on pump default settings, the pump set-up for your hospital/department may vary if additional features/set-up options have been added. • Always follow screen prompts and before pressing keys to proceed ensure selections made correspond with what is required.
File Type: PDF
File Size: 843 KB
File Name: bodyguard_series_quick_user_guide.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions