Nonin Pulse Oximeter Sensor Compatibility Guide 2013

Information Sheet

1 Page

Nonin Pulse Oximeter Sensor Compatibility Guide Use the chart below to find the right sensor for your needs. Visit nonin.com for more information and video tutorials.  MODEL NUMBER  DESCRIPTION  CABLE LENGTH  APPLICATION  PACKAGING  WristOx2® Model 3150  PalmSAT® 2500/2500A  8500 Series  Model 7500*  Avant® 2120  LifeSense®  PulseSense™  P  P  P  P  P  P  P  P  P  P  P  P  P  P  P  P  P  P  P  P  P  P  P  P  Reusable Soft Sensors 8000S Series 8000SS 8000SS-3  Small Soft Sensor 7.5 – 12.5 mm digit 0.3 – 0.5 inches digit  1m 3m  Index, middle or ring finger  Single  8000SS-WO2  Small Soft Sensor – WristOx2 7.5 – 12.5 mm digit 0.3 – 0.5 inches digit  0.3m  Index, middle or ring finger  Single  1m 3m  Index, middle or ring finger  Single  0.3m  Index, middle or ring finger  Single  1m 3m  Index, middle or ring finger  Single  0.3m  Index, middle or ring finger  Single  8000SM 8000SM-3 8000SM-WO2 8000SL 8000SL-3 8000SL-WO2  Medium Soft Sensor 10 – 19 mm digit 0.4 – 0.75 inches digit Medium Soft Sensor – WristOx2 10 – 19 mm digit 0.4 – 0.75 inches digit Large Soft Sensor 12.5 – 25.5 mm digit 0.5 – 1.0 inches digit Large Soft Sensor – WristOx2 12.5 – 25.5 mm digit 0.5 – 1.0 inches digit  P P P  Reusable Finger Clip, Ear Clip and Reflective Sensors 8000 Series 8000AA 8000AA-2 8000AA-3  Finger Clip Sensor – Adult > 30 kg / > 66 lbs  1m 2m 3m  Index, middle or ring finger  Single  8000AA-WO2  Finger Clip Sensor – WristOx2 > 30 kg / > 66 lbs  0.3m  Index, middle or ring finger  Single  8000AP 8000AP-3  Finger Clip Sensor – Pediatric 8 – 30 kg / 18 – 66 lbs  1m 3m  Index, middle or ring finger  Single  P  P  P  P  P  P  8000Q2  Ear Clip Sensor > 40 kg / > 88 lbs  1m  Earlobe  Single  P  P  P  P  P  P  8000R 8000H  Reflectance Sensor > 30 kg / > 66 lbs Sensor Holder 10 caps /20 stickers  1m N/A  Forehead  Single  P  P  P  P  P  P  P  P  P  P  P  P  P  Reusable Flex Sensors with FlexiWrap 8000J Series 8000J 8000J-3 8000JFW  Reusable FlexSensor – Adult > 22 kg / > 44 lbs incl. 25 Adult FlexiWraps  1m 3m N/A  Index, middle or ring finger  Single 24 per pack  8000J-W02 8000JFW  Reusable FlexSensor – WristOx2 > 30 kg / > 66 lbs incl. 25 Adult FlexiWraps  0.3m N/A  Index, middle or ring finger  Single 24 per pack  1m N/A  Toe  Single 24 per pack  P  P  P  P  P  P  1m N/A  Side of foot  Single 24 per pack  P  P  P  P  P  P  8008J 8008JFW 8001J 8001JFW  Reusable FlexSensor – Infant 2 – 22 kg / 4.4 – 44 lbs incl. 25 Infant FlexiWraps Reusable FlexSensor – Neonatal > 2 kg / 4.4 lbs incl. 25 Neonatal FlexiWraps  P  Single-Patient-Use Cloth Sensors 6000C Series 6000CA  Cloth Sensor – Adult > 30 kg / > 66 lbs  1m  Index, middle or ring finger  Single 24 per pack  P  P  P  P  P  P  6000CP  Cloth Sensor – Pediatric 10 – 40 kg / 22 – 88 lbs  1m  Index, middle or ring finger  Single 24 per pack  P  P  P  P  P  P  6000CI  Cloth Sensor – Infant 2 – 20 kg / 4.4 – 44 lbs  1m  Big toe  Single 24 per pack  P  P  P  P  P  P  6000CN  Cloth Sensor – Neonatal/Adult Neonatal: < 2 kg / < 4.4 lbs Adult: > 30 kg / > 66 lbs  1m  Foot  Single 24 per pack  P  P  P  P  P  P  Single-Patient-Use Flexi-Form® III Sensors 7000 Series 7000A  Flexi-Form Sensor – Adult > 30 kg / > 66 lbs  1m  Index, middle or ring finger  Single 24 per pack  P  P  P  P  P  P  7000P  Flexi-Form Sensor – Pediatric 10 – 40 kg / 22 – 88 lbs  1m  Index, middle or ring finger  Single 24 per pack  P  P  P  P  P  P  7000I  Flexi-Form Sensor – Infant 2 – 20 kg / 4.4 – 44 lbs  1m  Big toe  Single 24 per pack  P  P  P  P  P  P  1m  Foot  Single 24 per pack  P  P  P  P  P  P  1m  Finger  5 per pack  P  P  P  P  P  P  1m  Finger  5 per pack  P  P  P  P  P  P  Flexi-Form Sensor – Neonatal/Adult  7000N  Neonatal: < 2 kg / < 4.4 lbs Adult: > 30 kg / > 66 lbs  Single-Patient-Use Durafoam Sensors 6500 Series 6500SA  6500MA  Durafoam Sensor – Standard 5 – 21 mm/0.19 – 0.82 inches digit > 30 kg / > 66 lbs Durafoam Sensor – Small 5 – 21 mm/0.19 – 0.82 inches digit > 30 kg/ > 66 lbs  Accessories UNI-EXT-1 UNI-EXT-3 UNI-EXT-6 UNI-EXT-9  Extension Cable  1m 3m 6m 9m  Single  P  P  P  P  P  P  UNI-RA-3 UNI-RA-0  Right Angle Connector  3m 15cm  Single  P  P  P  P  P  P  31501  Adapter cable to 9-pin (D-Connector). Connects PureLight® sensors to the WristOx2 Model 3150  12cm  Single  3150WI  Adapter cable for Avant 4100 pulse oximeter and WristOx 3100 sensor  12cm  Single  P  *Also available is the Model 7500FO for use in MRI environments utilizing the 8000FI and 8000FC cable and sensor. ©2013 Nonin Medical, Inc. All Rights Reserved.  P/N 9577-001-01
File Type: PDF
File Size: 300 KB
File Name: Nonin Pulse Oximeter Sensor Compatibility Guide 2013.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions