NSK NAKANISHI

Handpiece Cleaning & Lubrication System

Handpiece Maintenance & Infection Control Guide Ver 3

Guide

2 Pages

Notes on Maintenance & Infection Control are being imposed in recent years to prevent your patients from infection during dental practices as well as to protect your clinic staff... With well-maintained instruments you can perform your practice more efficiently, comfortably and confidently... ore hygienic and proactive obligations  NSK presents NSK Infection Control Cycle, which begins with cleaning or washing, and then goes on disinfection and sterilisation... Step  1  Preparation Step  6  Storage  Step  Step  Infection Control  5  Sterilisation  4  Maintenance & Infection Control Guide  Cleaning  Step  Step  2  Tips to do it in the right way  3  Disinfection  Lubrication  • Important Notices Disinfection-ready Symbol  NSK recommends :  Warning :  This symbol on your NSK product means that the product can be cleaned and disinfected with a thermodisinfector... · Visually checking out your NSK instruments for any loosening and/or damage immediately after each practice...  Using protective clothing (tear-resistant gloves, goggles and possibly mouth protection)...  Adhering to directions described in NSK's operating manual and other documentation...  Using demineralised water for washing instruments... · Do not immerse handpieces in disinfectant solutions...  Do not use an ultrasonic bath for cleaning / washing handpieces... Autoclave Symbol This symbol on your NSK product means that the product can be sterilised with an autoclave at 135˚C max... The following recommendations are applicable in particular to:  • NSK Handpieces • NSK Air Scalers • NSK Surgical Micromotors PR-D337E Ver...  P4  H4  08...  H1   Air Turbine, Contra Angle & Straight Handpieces  P1  Surgical Micromotors  Air Scalers  1 PREPARATION 1  2 CLEANING 2  3 DISINFECTION 3  1 PREPARATION 1  2 CLEANING 2  3 3 DISINFECTION  1 PREPARATION 1  2 2 CLEANING  3 3 DISINFECTION  6 STORAGE 6  5 STERILISATION 5  4 LUBRICATION 4  6 STORAGE 6  5 5 STERILISATION  4 LUBRICATION 4  6 6 STORAGE  5 5 STERILISATION  4 LUBRICATION 4  1... REPARATION  Contra Angle : Remove the contra angle from the motor and detach the bur from the chuck... ir Turbine : Remove the air turbine from the coupling joint and detach the bur from the chuck... ring handpieces to a well-prepared cleaning room without contamination... emove organic contaminants with a paper wipe... 2... LEANING  Manual : Clean the external surface of handpiece with running water (<38˚C, demineralised water recommended)... utomated NSK handpieces with this symbol are the thermodisinfector-ready and may be washed and disinfected by using a thermodisinfector... hen using a thermodisinfector, be sure to follow its manufacturer's instructions... 3... ISINFECTION  Manual : Wipe the external surface of handpiece carefully with cleaning or disinfectant solution... utomated  4... UBRICATION  · Essential after every thermodisinfection process · Essential prior to sterilisation process Manual : Lubricate handpiece by using NSK Pana Spray Plus / Pana Spray... o prevent mist spray from escaping into the environment, use absorbent cloth... xpel excess lubrication... utomated : Clean and lubricate handpieces with NSK Care3 Plus... e sure to use a right adaptor for each handpiece... 5... TERILISATION  Place handpieces in a sterilisation pouch and seal them... N13060 4... 3 recommends autoclaving for 3 minutes (minimum holding time) at 134˚C or 15 minutes (minimum holding time) at 121˚C... SK recommends Class B or S sterilisation... All NSK handpieces are autoclavable at 135˚C Max...  6... TORAGE  Immediately after a sterilisation cycle, remove handpieces from the autoclave... eep them in a dust-free sterilised storage or bring them to a treatment room for use... P2  1... REPARATION  Remove the air scaler from the coupling joint and detach the tip... ring air scalers to a well-prepared cleaning room without contamination... emove organic contaminants with a paper wipe... 1... REPARATION  Attach an autoclave plug to the micromotor... Do not disconnect the motor cord from the micromotor... 2... LEANING  Manual : Clean the external surface of air scaler with running water (<38˚C, demineralised water recommended)... utomated NSK air scalers with this symbol are the thermodisinfector-ready and may be washed and disinfected by using a thermodisinfector... hen using a thermodisinfector, be sure to follow its manufacturer's instructions... 2... LEANING  Manual : Clean the external surface of micromotor with running water (<38˚C, demineralised water recommended)... 3... ISINFECTION  Manual : Wipe the external surface of micromotor with cleaning or disinfectant solution... 3... ISINFECTION  Manual : Wipe the external surface of air scaler with cleaning or alcohol for disinfection... utomated  4... UBRICATION  The NSK surgical micromotor series is maintenance-free... o not lubricate micromotors... 4... UBRICATION  · Essential after every thermodisinfection process · Essential prior to each sterilisation process Manual : Supply 1-2 drops of NSK Turbine Oil to the drive air port of the air scalers... onnect to the coupling joint and operate for 5 seconds... ote : Excessive oil may cause unstable motion... lease consult the operating manual before use... 5... TERILISATION  Place micromotors in a sterilisation pouch and seal them... N13060 4... 3 recommends autoclaving for 3 minutes (minimum holding time) at 134˚C or 15 minutes (minimum holding time) at 121˚C... SK recommends Class B or S sterilisation... All NSK micromotors are autoclavable at 135˚C Max...  6... TORAGE  Immediately after a sterilisation cycle, remove micromotors from the autoclave... eep them in a dust-free sterilised storage or bring them to a treatment room for use... 5... TERILISATION  Place air scalers in a sterilisation pouch and seal them... N13060 4... 3 recommends autoclaving for 3 minutes (minimum holding time) at 134˚C or 15 minutes (minimum holding time) at 121˚C... SK recommends Class B or S sterilisation... All NSK air scalers are autoclavable at 135˚C Max...  6... TORAGE  Immediately after a sterilisation cycle, remove air scalers from the autoclave... eep them in a dust-free sterilised storage or bring them to a treatment room for use... P3
File Type: PDF
File Size: 852 KB
File Name: handpiece_maintenance___infection_control_guide_ver.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions