NSK NAKANISHI

High Speed Drill System

SurgicPro Operation Manual

Operation Manual

22 Pages

Original Operatrion Manual  English  Thank you for purchasing the NSK Surgic Pro series surgical unit... e recommend that prior to use, you carefully read this document regarding instructions for use, handling method, or maintenance check so that you can carry on using the unit in the future... n addition, keep this operation manual in a place where a user can refer to it at any given time...  Intended to Use Surgic Pro series is intended for use in dental oral surgery and surgical procedures by qualified personnel... Contents 1... 0... 1... 2... 3... 4... 5... 6... Safety precautions prior to use Package Contents Control Unit and Foot Control Installation Setting Operation Protection Circuit Error Code & Troubleshooting Fuse Replacement Maintenance Sterilization Contra Angle Handpieces and Accessories Specification Disposing Product Symbols EMC Information  2 4 5 7 10 12 16 16 18 18 19 20 20 20 21 21  ◆ Classification of equipment • Type of protection against electric shock : – Class l equipment • Degree of protection against electric shock : – Type BF applied part • Method of sterilization or disinfection recommended by the manufacture : – See 11... terilization • Degree of protection against ingress of water as detailed in the current edition of IEC 60529 : – Foot Control: IPX8 (Protected against the effects of continuous immersion in water) • Degree of safety of application in the presence of a flammable anesthetic mixture with air or with oxygen or nitrous oxide : – Foot Control: Category AP Equipment • Mode of operation : – Intermittent operation  1   Cautions for handling and operation Read these safety cautions thoroughly before use and operate the product properly... hese indicators are to allow you to use the product safely, prevent danger and harm to you and others... hese are classified by degree of danger, damage and seriousness... ll indicators concern safety, be sure to follow them... Classification  Degree of Danger or Damage and Seriousness  W A R N I N G Explains an instruction where personal injury or physical damage may occur...  A U T I O N Explains an instruction where minor to medium injury or physical damage may occur...  O T I C E Explains an instruction that should be observed for safety reasons... 1... afety precautions prior to use Read Handpiece’s Operation manual carefully before use... ARNING • TO PREVENT ELECTRIC SHOCK Do not unplug the AC Power cord with wet hands...  TO PREVENT ELECTRIC SHOCK Be sure to prevent water on the Control Unit...  TO PREVENT ELECTRIC SHOCK Use an electrical outlet that is grounded...  The system may present a possibility of malfunction when used in the presence of an electromagnetic interference wave... o not install the system in the vicinity of the device which emits magnetic waves... urn off the Main Power Switch of the Control Unit of this system when an ultrasonic oscillation device or an electrode knife is located in the vicinity is used... CAUTION • The accuracy of the Torque Monitor depends on the high precision performance of the handpiece attached to the micromotor... eal torque value may not otherwise be correctly displayed... o guarantee handpiece torque accuracy, that matches the monitor display system, USE ONLY the NSK contra angle handpieces listed on “12... ontra Angle Handpieces and Accessories”... hen other handpice had connected, it may not output accurate torque which indicated on handpiece...  Surgic Pro series needs special precautions regarding EMC and needs to be installed and put into service according to the EMC information... Refer to 16... MC Information) • Portable and mobile RF (Radio Frequency) communications equipment can affect Surgic Pro series... o not use RF equipment outskirts for the product...  The use of accessories, Motors and cables other than those specified, with the exception of Motors and cables sold by the manufacturer of Surgic Pro series as replacement parts for internal components, may result in increased EMISSIONS or decreased IMMUNITY of the Control Unit...  Surgic Pro series should not be used adjacent to or stacked with other equipment and that if adjacent or stacked use is necessary, the Control Unit should be observed to verify normal operation in the configuration in which it will be used...  When operating this system always consider the safety of the patient...  Do not attempt to disassemble the Control Unit /Foot Control / Micromotor nor temper with the mechanism...  Check for vibration, noise and overheating before use and if any abnormalities are found in use, stop using immediately and contact dealer...  Use an electrical outlet that is grounded...  Do not drop, hit, or subject to excessive shock...  Do not bend the Irrigation Tube while the water pomp is operating... t could cause tube breakage...  Do not use bent, damaged or sub-standard burs or drill... he Shank could bend or brake...  Do not exceed the recommended speed and torque...
File Type: PDF
File Size: 496 KB
File Name: surgicpro_operation_manual.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions