Page 1

INSTRUCTIONS

Working Element

WA22366A, WA22367A

Caution: Federal (USA) law restricts this device to sale by or on the order of a physician.

Page 2

Working Element

W7.074.651

Page 3

1 CONTENTS

1 General Information............................................................. 4

1.1 Intended Use................................................................ 4

1.2 Instruction Manuals....................................................... 8

1.3 Upon Delivery............................................................... 9

1.4 Manufacturer/Distributor............................................. 11

2 Terminology....................................................................... 12

2.1 Shape of HF-Resection Electrodes............................ 15

2.2 Color Codes of HF-Resection Electrodes................... 18

3 Compatible Components................................................... 19

3.1 Before Use.................................................................. 23

3.2 Inspection and Testing................................................ 24

4 Use.................................................................................... 26

4.1 Preparation................................................................. 27

4.2 Procedure................................................................... 31

4.3 After Use..................................................................... 36

5 Reprocessing of WA22366A, WA22367A, WA22351A,

WA22355A, WA22538A..................................................... 37

5.1 Cleaning...................................................................... 39

5.2 Maintenance............................................................... 42

6 Repair................................................................................ 43

W7.074.651

Working Element

Page 4

4

1 General Information

1.1 Intended Use

WA22366A, WA22367A

Working element for cutting, coagulation, and vaporization

in conductive irrigation fluid or conductive distension

medium in the Saline mode.

Do not use it for any other purpose.

WA22301D, WA22302D, WA22305D, WA22306D,

WA22331D, WA22332D, WA22351A, WA22351C,

WA22355A, WA22355C, WA22503D, WA22507D,

WA22521C, WA22523C, WA22537D, WA22538A,

WA22538C, WA22539D, WA22558C

HF-resection electrode for transurethral endoscopic

diagnosis and treatment in urological surgical procedures

for use in the prostate, bladder and bladder neck involving

the resection, ablation or removal of soft tissue and where

hemostatis is required.

Do not use it for any other purpose.

WA22602D, WA22603D, WA22606D, WA22607D,

WA22621C, WA22623C, WA22632D, WA22651C,

WA22655C

HF-resection electrode for transurethral endoscopic

diagnosis and treatment in urological surgical procedures

for use in the prostate, bladder and bladder neck involving

the resection, ablation or removal of soft tissue and where

hemostatis is required.

Do not use it for any other purpose.

Working Element

W7.074.651

Page 5

5

WA22557C

HF-resection electrode for plasma vaporization for

transurethral endoscopic diagnosis and treatment in

urological surgical procedures for use in the prostate,

bladder and bladder neck involving the vaporization,

ablation, coagulation, cutting, removal of soft tissue and

coagulation where hemostatis is required.

Do not use it for any other purpose.

WA22657C

HF-resection electrode for plasma vaporization for

transurethral endoscopic diagnosis and treatment in

urological surgical procedures for use in the prostate,

bladder and bladder neck involving the vaporization,

ablation, coagulation, cutting, removal of soft tissue and

coagulation where hemostatis is required.

Do not use it for any other purpose.

W7.074.651

Working Element

Page 6

6

Applications

HF-resection electrodes are classified according to their

compatibility with coagulation, cutting, or vaporization.

Refer to the table for compatible applications of the

selected HF-resection electrode. These devices are

intended to be used in an irrigated environment. Use HFresection electrodes only for compatible applications.

+ = compatible

– = not compatible

Article number

Coagulation

Cutting

Vaporization

WA22301D

+

+

–

WA22302D

+

+

–

WA22305D

+

+

–

WA22306D

+

+

–

WA22331D

+

+

–

WA22332D

+

+

–

WA22351A/C

+

–

–

WA22355A/C

+

+

–

WA22503D

+

+

–

WA22507D

+

+

–

WA22521C

+

+

–

WA22523C

+

+

–

WA22557C

+

–

+

WA22558C

+

+

–

WA22537D

+

+

–

WA22538A/C

+

–

–

WA22539D

+

+

–

WA22602D

+

+

–

WA22603D

+

+

–

WA22606D

+

+

–

WA22607D

+

+

–

WA22621C

+

+

–

WA22623C

+

+

–

WA22632D

+

+

–

Working Element

W7.074.651

Page 7

7

Article number

Coagulation

Cutting

Vaporization

WA22651C

+

–

–

WA22655C

+

+

–

WA22657C

+

–

+

Specific urological indications

HF-resection electrodes compatible with coagulation/

cutting:

-- Transurethral resection in saline (TURis)

-- Transurethral prostatectomy, transurethral resection of the

prostate (TURP) for benign prostatic hyperplasia

-- Transurethral incision of the prostate (TUIP) or bladder

neck, transurethral resection of bladder tumors (TURBT)

and cystodiathermy

HF-resection electrodes compatible with vaporization:

-- Treatment of benign prostate hyperplasia BPH, bladder

cancer, tumors, lesions and neoplasms

-- Transurethral electrovaporization (TUVP, TVP, TUEVP),

also known as transurethral vapor resection of the

prostate (TUVRP) or transurethral vaporization in saline

(TUVis)

Medical use

This product is to be used only in a medical facility by

trained medical personnel.

W7.074.651

Working Element

Page 8

8

CAUTION!

For single use only

The following products are for single use only.

Do not reuse or attempt to resterilize.

WA22301D, WA22302D, WA22305D, WA22306D,

WA22331D, WA22332D, WA22351C, WA22355C,

WA22503D, WA22507D, WA22521C, WA22523C,

WA22537D, WA22538C, WA22539D, WA22557C,

WA22558C, WA22602D, WA22603D, WA22606D,

WA22607D, WA22621C, WA22623C, WA22632D,

WA22651C, WA22655C, WA22657C

Medical Device Directive (Europe)

This product complies with the requirements of Directive

93/42/EEC concerning medical devices.

1.2 Instruction Manuals

NOTE!

Instruction manual set

The complete instruction manual set for this product

consists of this product-specific instruction manual

(delivered together with this product) and the systemrelated instruction manual, entitled “Olympus Endoscopy

System Guide” (supplied with Olympus telescopes).

Immediately contact an Olympus representative if either

manual is missing or lost. Keep the instruction manual set

in a safe, accessible location.

Working Element

W7.074.651

Page 9

9

WARNING!

Read all instruction manuals thoroughly

Before use, read this manual, the Olympus Endoscopy

System Guide, and the manuals for all other equipment

which will be used during the procedure. An insufficient

understanding of the dangers, warnings, cautions, and

information in these manuals can result in death, serious

injury, or equipment damage.

1.3 Upon Delivery

Inspect immediately

• Make sure that the shipping case contains all of the items

listed below.

• Contact your Olympus representative or an authorized

service center if any items are missing or damaged.

Contents working element

Working elements: WA22366A, WA22367A

-- Instruction manual

-- Working element

W7.074.651

Working Element

Page 10

10

Contents HF-resection electrode

HF-resection electrodes: WA22301D, WA22302D,

WA22305D, WA22306D, WA22331D, WA22332D,

WA22351A, WA22351C, WA22355A, WA22355C,

WA22503D, WA22507D, WA22521C, WA22523C,

WA22537D, WA22538A, WA22538C, WA22539D,

WA22557C, WA22558C

-- Access information sheet

-- HF-resection electrode

Contents HF-resection electrode

HF-resection electrodes: WA22602D, WA22603D,

WA22606D, WA22607D, WA22621C, WA22623C,

WA22632D, WA22651C, WA22655C, WA22657C

-- Access information sheet

-- HF cable

-- HF-resection electrode

Unpacking

• Remove the product from the packaging. Do not use the

packaging for routine storage.

Working Element

W7.074.651

Page 11

11

CAUTION!

Sterilized product*

Store the following products in a dry and clean environment

at room temperature. Avoid direct contact with sunlight,

high temperature, and high humidity.

*Applies to the following products:

WA22301D, WA22302D, WA22305D, WA22306D,

WA22331D, WA22332D, WA22351C, WA22355C,

WA22503D, WA22507D, WA22521C, WA22523C,

WA22537D, WA22538C, WA22539D, WA22557C,

WA22558C, WA22602D, WA22603D, WA22606D,

WA22607D, WA22621C, WA22623C, WA22632D,

WA22651C, WA22655C, WA22657C

1.4 Manufacturer/Distributor

Manufacturer:

Olympus Winter & Ibe GmbH

Kuehnstraße 61

22045 Hamburg

Germany

Distributor:

Olympus Winter & Ibe GmbH

Kuehnstraße 61

22045 Hamburg

Germany

W7.074.651

Working Element

Page 12

12

2 Terminology

Active working element

WA22366A

1) Handle

2) Telescope release button

3) HF connector (for HF cable’s right angle plug)

4) Telescope channel

5) Thumb ring

6) HF connector (for HF cable’s straight plug)

7) Electrode release button

8) Locking cone

9) Electrode guiding tube

Working Element

W7.074.651

Page 13

13

Passive working element

WA22367A

1) Handle

2) Telescope release button

3) HF connector (for HF cable’s right angle plug)

4) Telescope channel

5) Thumb ring

6) HF connector (for HF cable’s straight plug)

7) Electrode release button

8) Locking cone

9) Electrode guiding tube

W7.074.651

Working Element

Page 14

14

HF cable

WA00013A

1) Straight plug

2) Right angle plug

HF-resection electrode

WA22301D, WA22302D, WA22305D, WA22306D,

WA22331D, WA22332D, WA22351A, WA22351C,

WA22355A, WA22355C, WA22503D, WA22507D,

WA22521C, WA22523C, WA22537D, WA22538A,

WA22538C, WA22539D, WA22557C, WA22558C

1) Cutting loop

2) Stabilizing tube

Working Element

W7.074.651

Page 15

15

HF-resection electrode with instrument recognition

WA22602D, WA22603D, WA22606D, WA22607D,

WA22621C, WA22623C, WA22632D, WA22651C,

WA22655C, WA22657C

1) HF-resection electrode

2) Generator plug

3) Straight plug

4) Right angle plug

5) HF cable

2.1 Shape of HF-Resection Electrodes

WA22301D, WA22302D, WA22305D, WA22306D,

WA22503D, WA22507D, WA22537D, WA22602D,

WA22603D, WA22606D, WA22607D

Loop.

W7.074.651

Working Element

Page 16

16

WA22558C

Loop with runner.

WA22351A, WA22351C, WA22538A, WA22538C,

WA22651C

Roller.

WA22355A, WA22355C, WA22655C

Needle.

WA22521C, WA22523C, WA22621C, WA22623C

Band.

Working Element

W7.074.651

Page 17

17

WA22557C, WA22657C

Button.

WA22331D, WA22332D, WA22539D, WA22632D

Angled loop.

W7.074.651

Working Element

Page 18

18

2.2 Color Codes of HF-Resection Electrodes

1) Size.

Inner sheath [Fr.] Outer sheath [Fr.]

Yellow

24

26/27

Grey

24/26/28

26/27/28

2) Blue for resection with saline solution.

3) Direction of view.

Red

30°

Blue

12°

White

12°/30°

Working Element

W7.074.651

Page 19

19

3 Compatible Components

WARNING!

Risk of injury to the patient and/or user

Use only compatible equipment as listed in this section.

If other combinations are used, the full responsibility

is assumed by the user. Future products may also be

compatible. For further details contact an Olympus

representative.

NOTE!

Product may not be available in all sales territories.

W7.074.651

Working Element

Page 20

20

Urology

Working Element

W7.074.651

Page 21

21

W7.074.651

Working Element

Page 22

22

Urology

Working Element

W7.074.651

Page 23

23

3.1 Before Use

WARNING!

Infection control risk

Properly reprocess the following products before first and

each subsequent use following the instructions in this

manual and in the Olympus Endoscopy System Guide.

Improper and/or incomplete reprocessing can cause

infection of the patient and/or medical personnel.

WA22366A, WA22367A, WA22351A, WA22355A,

WA22538A

WARNING!

Sterilized product

The following products are delivered in a sterilized

condition. Only open the package immediately before

use. Do not autoclave the product. The products will be

damaged.

WA22602D, WA22603D, WA22606D, WA22607D,

WA22621C, WA22623C, WA22632D, WA22651C,

WA22655C, WA22657C

WARNING!

Sterilized product

The following products are delivered in a sterilized

condition.

Only open the package immediately before use.

WA22301D, WA22302D, WA22305D, WA22306D,

WA22331D, WA22332D, WA22351C, WA22355C,

WA22503D, WA22507D, WA22521C, WA22523C,

WA22537D, WA22538C, WA22539D, WA22557C,

WA22558C

NOTE!

Spare equipment

Always have spare equipment available in case of a

malfunction.

W7.074.651

Working Element

Page 24

24

3.2 Inspection and Testing

Inspecting the product

Visually inspect the product. Make sure that it has:

-- no corrosion

-- no dents

-- no scratches

Inspect the HF-resection electrode and the HF cable

Warped electrodes, defective insulation and cracked or

irregular cutting loops represent a danger to the patient and

the surgeon.

Never try to bend irregular cutting loops into shape. Inspect

the HF cable for defective insulation.

Inspect the generator plug for deformed pins.

Do not use defective instruments.

Test the instrument

• Operate the handle.

Make sure that the working element moves smoothly.

®

Damaged product

If the product is damaged or does not function properly,

contact an Olympus representative or an authorized service

center.

No repairs

For safety reasons, defective HF-resection electrodes must

not be repaired. Replace a defective HF-resection electrode

with a new one.

Working Element

W7.074.651

Page 25

25

CAUTION!

Wear

When used as intended, this product is more or less

subject to wear depending on the intensity of use. In

case a product has externally visible defects, contact

the responsible Olympus representative at once. Later

guarantee claims are forfeited. Any guarantee claims are

void by previous use.

W7.074.651

Working Element

Previous Page Next Page
© 2021 BioClinical Services Ptd Ltd
Terms of Use
Privacy Statement