1. ROCKET® CRAFT™ SUCTION PUMPS
1.1. General Description:
The Rocket® Craft™ Suction Pumps have been developed to provide a smooth, low volume
vacuum at a pre-determined negative pressure. Vacuum is activated by a foot operated switch
controlled by the surgeon performing oocyte collection.
The range of vacuum is variable from 0-400mm Hg and adjustable over this range by a pre-set
control. Vacuum is provided by a quiet diaphragm pump, working from a mains voltage supply
and manufactured to BS 5724 Class 1 and CE safety regulations.
The Rocket® Craft™ is supplied with both a reusable water trap set as standard designed to
help prevent aspirated fluids being drawn into the vacuum power unit. The trap also acts as a
reservoir to provide an even vacuum pressure during procedures. A single patient use,
disposable water trap set is also available.
The foot control has an air-operated solenoid, switching the main pump unit. No electrical
connections are made to the sealed foot operated control.
A suitable collection test tube for use with oocyte needle sets is B.D. Falcon test tube No.
2001F, 17 x 100mm.
1.2. References:
Craft I, McLeod F. Edmonds K, ‘Human embryo transfer technique’. Lancet 1961 ii 1104-5
Craft I, Diahanbakch O. McLeod F et al ‘Human pregnancy following oocyte and sperm transfer
to the uterus.’ Lancet 1992 i 1031-3
Craft I, (1984) ‘Clinical Methodology’ British Journal of Hospital Medicine 90-102
ZDOCK105
Rev. 07
15/01/09
Copyright© ROCKET MEDICAL PLC 2001- 2009
Page 3
USERS MANUAL – ROCKET® CRAFT™ SUCTION PUMPS – ALL MODELS
Page 3
1.3. Warranty
Rocket® Craft™ 220V Suction Pumps are sold by Rocket Medical plc under the warranties set
forth in the following paragraphs. Such warranties are extended only with respect to the
purchase of the Products directly from Rocket Medical plc as new merchandise and are
extended to the first Buyer thereof, other than for resale.
For a period of twelve (12) months from the date of shipment the Products are warranted to be
free from functional defects in materials and workmanship and to conform to the description of
the Products contained in the operating manual and accompanying labels, provided the same is
properly operated under conditions of normal use, that annual maintenance and service is
performed at an authorised Rocket Medical plc service facility
Removal of any QC seal voids the warranty.
The foregoing warranties shall not apply if the Products have been repaired other than by
Rocket Medical plc or other than in accordance with written instructions provided by Rocket
Medical plc , or altered by anyone other than Rocket Medical plc, or if the Products have been
subject to misuse, negligence, or accident.
Rocket Medical plc 's sole and exclusive obligation and Buyer's sole and exclusive remedy
under the above warranties is limited to repairing or replacing, free of charge, at Rocket
Medical plc 's option, Products, which are telephonically reported to Rocket Medical plc and
which, if so advised by Rocket Medical plc, is thereafter returned with a statement of the
observed deficiency, not later than seven (7) days after the expiration date of the warranty, to
Rocket Medical plc during normal business hours, transporting charges prepaid and which,
upon Rocket Medical plc's examination, is not found to conform with the above warranties.
Rocket Medical plc shall not be otherwise liable for any damages including but not limited to
incidental damages, consequential damages or special damages.
There are no express or implied warranties which extend beyond the warranties herein above
set forth. Rocket Medical plc makes no warranty of merchantability or fitness for a particular
purpose with respect to the Products or parts thereof.
1.4. Service and Repairs:
Craft™ Pumps normally require little routine maintenance, however they must be serviced and
calibrated annually at an Rocket Medical plc service facility.
Please contact any of our Customer Services Departments for details of your nearest service
centre
ZDOCK105
Rev. 07
15/01/09
Copyright© ROCKET MEDICAL PLC 2001- 2009
Page 4
USERS MANUAL – ROCKET® CRAFT™ SUCTION PUMPS – ALL MODELS
Page 4
2. OPERATING INSTRUCTIONS ROCKET® CRAFT™
VACUUM UNIT R29.654 & R29.655
9
Connect main lead to electrical supply 230/240 volt 50 Hz
(R29.655) or 110/120 volt 60 Hz. (R29.654)
9
The reusable water trap set should be packed and sterilised by
autoclaving at 135°C @ 3 bar for 3 mins. prior to each use.
9
Rocket Medical plc recommend the use of Rocket® Craft™
Single Use Water Trap sets which are available from your local
agent or Customer Services.
9
Using aseptic technique, unpack the water trap and insert the
glass water trap bottle into the clip at the left hand side of the
casing.
9
Connect the short tube to the port marked SUCTION and secure
with a light push fit.
9
Pass the longer patient connection tube into the operative field.
9
Connect foot switch tube to connector on front panel.
9
Activate vacuum by depressing foot switch. The pump will stop
when the foot is lifted from the pad.
9
Set the required vacuum required by occluding the vacuum line
distal (patient side) to the water trap and adjusting the control to
the desired level as shown by the needle on the gauge
Craft™ Single Use Water Trap Set
9
During the aspiration of the fluid the control knob may be adjusted to the
precise vacuum require under load, approximately 100-200mm Hg.
9
NOTE: Thinner gauge needles (17G) and those with longer tube sets, 7090cm may require vacuums in the region of 150-200mmHg to achieve
satisfactory flow rates.
9
The unit is then ready for use.
9
If vacuum lines become blocked due to debris or viscous fluids, a
temporary high vacuum can be obtained to unblock the needle and tubing
by occluding the finger bleed hole on the front panel, marked “OCCLUDE
FOR MAXIMUM VACUUM”. High vacuum should NOT be used to aspirate oocytes.
9
Placing a finger on the red disc for a few seconds will clear the tubing lines at 300-400mm Hg
temporary high vacuum.
9
On completion depress front panel
switch at “O” to switch the unit off.
Craft™ Suction Pump with single foot control, shown with re-us
ZDOCK105
Rev. 07
15/01/09
Copyright© ROCKET MEDICAL PLC 2001- 2009
Page 5
USERS MANUAL – ROCKET® CRAFT™ SUCTION PUMPS – ALL MODELS
Page 5
3. OPERATING INSTRUCTIONS ROCKET® CRAFT™
VACUUM UNIT R29.660 & R29.661
9
9
Connect main lead to electrical supply 230/240 volt 50 Hz
(R29.660) or 110/120 volt 60 Hz. (R29.661)
Connect the dual foot switch tubes to the push connectors on
front panel.
9
The reusable water trap set should be packed and sterilised by
autoclaving at 135°C @ 3 bar for 3 mins prior to each use.
9
Rocket Medical plc recommend the use of Rocket® Craft™
Single Use Water Trap sets which are available from your local
agent or Customer Services.
9
Using aseptic technique, unpack the water trap and insert the
glass water trap bottle into the clip at the left hand side of the
casing. Reusable water trap sets are available, contact your local
agent or Customer Services.
9
Connect the short tube to the port marked SUCTION and secure
with a light push fit.
9
Pass the longer patient connection tube into the operative field.
9
9
Connect foot switch tube to connector on front panel.
Activate vacuum by depressing LOW VACUUM (Larger) foot
switch. The pump will stop when the foot is lifted from the pad.
9
Set the required vacuum required by occluding the vacuum line distal
(patient side) to the water trap and adjusting the control to the desired
level as shown by the needle on the gauge
9
During the aspiration of the fluid, the control knob may be adjusted to
the precise vacuum required under load, approximately 100-200mmHg.
9
NOTE: Thinner gauge needles (17G) and those with longer tube sets,
70-90cm may require vacuums in the region of 150-200mmHg to
achieve satisfactory flow rates.
9
The unit is now ready for use.
9
If vacuum lines become blocked due to debris or viscous fluids, a temporary high vacuum can be
obtained to unblock the needle and tubing by depressing the smaller HIGH Vacuum foot switch this
provides a temporary high vacuum up to 440mmHg.
9
High vacuum should NOT be used to
aspirate oocytes.
9
On completion depress font panel
switch at “O” to switch the unit off.
®
Rocket Craft™ Single Use Water Trap Set
Craft™ DuoVac with twin foot control and reusab
ZDOCK105
Rev. 07
15/01/09
Copyright© ROCKET MEDICAL PLC 2001- 2009
Page 6
USERS MANUAL – ROCKET® CRAFT™ SUCTION PUMPS – ALL MODELS
Page 6
Rocket® Single Use Water Trap Set
for use with all Rocket® Craft™
Suction Pumps
The Rocket® Water Trap Set for use with Rocket® Craft™
Suction Pumps offers a simple, cost effective solution to
contamination risks and reuse problems.
• COMPLETE SET: Provides the complete bottle and tubing set
in single, sterile pack for one time patient use.
• GLASS TRAP BOTTLE: To maintain clear view in the event of
potential pump contamination with aspirate. Designed to
withstand >450mmHg vacuum.
• REMOVES CONTAMINATION RISK from irregular or
uncontrolled decontamination of reusable bottle, bung and
angle tube set.
• PATIENT TUBE SET: 2m patient tube set with integral luer
lock connector to ensure secure, reliable connection to the
aspiration needle set.
• SUITABLE FOR USE: Compatible with all versions of Craft™
Suction and Duo Vac.
• Also compatible with the genX and Pioneer Pro Pumps.
Ordering Information
Rocket® Water Trap Set suitable for all
Rocket® Craft™ Suction Pumps
Sterile
each
R57.685
Packed individually, 10 per carton
ZDOCK105
Rev. 07
15/01/09
Copyright© ROCKET MEDICAL PLC 2001- 2009
Page 7
USERS MANUAL – ROCKET® CRAFT™ SUCTION PUMPS – ALL MODELS
Page 7
4. SPARE PARTS: CRAFT SUCTION PUMPS:
Item
1.
3.
10.
11.
12.
14.
15.
18.
19.
20.
21/22
22.
23.
25.
28
104.
Part No.
R29.655
R29.654
B14-011
B02-009
B02-140
F06-006
R06-027
C12-030
F04-027
F04-023
E05-000
N05-016
K01-001
O04-000
G03-005
C01-035
I08-004
S10-027
C01-034
B05-005
Description
CRAFT SUCTION PUMP, 240V.
CRAFT SUCTION PUMP, 110V.
Box, lower half
Bottle Bracket
Bottle Bracket assembly (bracket & white plastic coated clip)
Front Panel Fin
Rear Panel 240v
Chassis bare
Filter assembly (Silencer)
Filter housing assembly
Filter Element (part of item 15)
Needle Valve assembly
Knob Pointer
Vacuum Control Orifice assembly
Vacuum Gauge 0-600mmHG and connector assembly (items 21 & 22)
Connector
IEC Connector
Switch 240v
Flanged Connector
Footswitch
(Cat.No. R29.656)
59.
11.
19.
44
13.
34.
30.
42.
56.
55.
48.
58.
51.
50.
45.
52.
53
104.
22.
-
R29.660
R29.661
B14-009
B14-011
C12-044
F06-022
B02-009
S10-007
S18-004
I08-004
S10-001
N05-014
K01-001
G03-004
B20-010
N06-002
N06-003
C01-034
C01-179
C01-178
B05-004
F04-004
C01-176
C01-177
CRAFT DUO-VAC SUCTION PUMP 240V.
CRAFT DUO-VAC SUCTION PUMP 110V.
Case Upper Half
Case Lower Half
Chassis
Front Panel
Bottle Bracket
Pressure Switch
Solenoid Valve
IEC Connector
Switch/Indicator
Stop Pin/Nut (Part of N05-016 Needle Valve Assembly)
Knob
Vacuum Gauge 0-600mmHG
Ventilator blanks
Neon Indicator Green
Neon Indicator Red
Flanged connector
Plastic Connector MALE (on front of Pump under standard vacuum green indicator)
Plastic Connector FEMALE (on front of Pump under high red vacuum indicator)
Footswitch, Dual Vacuum
(Cat.No.R29.662)
Filter Assembly (silencer)
Set of 2 Plastic connectors for Footswitch, high vacuum
Green Connector (Female) for lead on Dual Footswitch
Red Connector (male) for lead on Dual Footswitch
ZDOCK105
Rev. 07
15/01/09
Copyright© ROCKET MEDICAL PLC 2001- 2009
Page 8
USERS MANUAL – ROCKET® CRAFT™ SUCTION PUMPS – ALL MODELS
Page 8
4.1.MOTOR SPARES & ACCESSORIES
Item
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Part No.
SO1-214
WO1-000
SO1-138
HO1-001
VO1-002
VO2-001
SO1-203
DO2-001
GO1-001
DO1-053
CO2-031
BO2-035
SO1-104
WO1-051
SO1-018
C03-084
MO1-311
15
MO1-312
-
S02-012
ZDOCK105
Rev. 07
Description
Screw 4BA x 3/4" pan pozi b'zinc
Washer for the above (flat) 6BA b'zinc
Head Screw (centre) no. 4 x 1/4" pan pozi
Head 800111
Valve diaphragm 800109B EPDM
Valve plate 800110
Screw 6BA X 5/16" csk S/S
Diaphragm plate upper 700172
Gasket 690260 Grey Poly
Pump Diaphragm 700190C EPDM
Crankcase 770137
Bracket 820170 blk. anodis
Screw no 4 x 3/16" pan pozi 'B' b'zinc
Washers S/P int. M4 bzn
Screws M4 x 10 pan pozi bzn
Complete Conrod Assembly, including top diaphragm plate
Motor 770139 220/240v
(includes motor, crank case and valves)
Motor 730190 110/120v 50 Hz.
(includes motor, crank case and valves)
Service Kits (EPDM) includes items 3 and 8 plus a washer
15/01/09
Copyright© ROCKET MEDICAL PLC 2001- 2009
Qty.
4
4
1
1
1
1
1
1
1
1
1
1
4
2
2
1
1
1
1