SONOPET

Altrix Temperature Management System

Altrix Disinfection Guide Rev A.1

Disinfection Guide

2 Pages

Altrix™ Precision Temperature Management System  Disinfection guide Disinfecting Disinfect the internal water circuit and hoses every 14 days Use the BruClean TbC disinfectant tablets by Brulin (EPA registration number 71847-2-106) before first use, at least every 14 days, and before storage. BruClean TbC has been validated for internal water circuit disinfection. Make sure that you follow the disinfectant manufacturer’s guidelines to avoid the risk of injury. Failure to follow the disinfectant’s instructions may void your warranty. • Always use sterile distilled water or water that has been passed through a filter less than or equal to 0.22 microns with this product. • Do not disinfect the internal water system with a thermal transfer device attached as this may cause a leak. Note: Disinfection • Do not use bleach or any other cleaning or disinfectant agents for internal circuits. This could result in damage to the product. Only of the Altrix use approved disinfectant tablets. internal water • Always drain the product before disinfecting the internal water system was circuit. Failure to drain the product may reduce the effectiveness validated using of the disinfection process. M. mucogenicum.  Caution  Tools required: • 2 gallons (11.4 L) of sterile distilled water or water that has been passed through a filter less than or equal to 0.22 microns • Personal protection equipment (PPE) as recommended by the disinfectant manufacturer’s instructions • Soft, lint free cloth (2 or more) • 2 BruClean TbC 13.1 g tablets (Active ingredient NaDCC solution ppm = 1874 mg/L) Note: BruClean TbC is a blend of 48% sodium dichloroisocyanturate and Adipic Acid with a 5% sodium dodecyl benzene sulphonate surfactant. • Service tool adapter hose (8001-999-017) for Colder style connector hoses  • Floor drain  See Product illustration on page 10 of the manual for clarification of product component names and locations.  Draining the internal water circuit and hoses for disinfection 1. Unplug the power cord from the wall outlet. 2. Place the controller over a floor drain. Note: For best results, the floor drain should be within reach of a wall outlet to power on the controller. 3. To drain the controller, pull up on the controller drain plug (A) to open the drain (Figure 24). Leave the drain open.  Figure 24  Draining the internal water circuit and hoses for disinfection (cont.) 4. Connect a hose to each port (Figure 25). 5. Close the connector ends of all three hoses: a. If you have Colder style connector hoses, attach the service tool adapter hose (8001-999-017) (Figure 26). Complete this for all three hoses. b. If you have Clik-Tite hoses, make sure that the connector ends are connected and closed (A), and clamps are open (B). Complete this for all three hoses (Figure 27).  Figure 25  Figure 26  6. To fully drain the hoses, raise all the hoses (Figure 28) above the connection ports on the controller. Note: For best performance, hang the hoses to keep them raised. Do not lower the hoses until you have completed the disinfection and rinsing process. 7. Allow the controller and hoses to drain for a minimum of two minutes. 8. Push down on the drain plug to close the drain.  Figure 27  Figure 28
File Type: PDF
File Size: 531 KB
File Name: Altrix Disinfection Guide Rev A.1.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions