Valleylab

Valleylab FT10

FT10 Software Update Guide

Guide

2 Pages

Software Update Guide VALLEYLAB™ FT10 GENERATOR BEFORE YOU START You will need a laptop, Ethernet cable, and small Phillips-head screwdriver... MPORTANT Before you start a software update, you must have a Valleylab™ Exchange username and password... o setup an account, start the Valleylab™ Exchange application and click Create Account... t may take up to 3 business days to receive your username and password... ollow the steps below to set up your generator... f you need additional help, go to www... vidien... m/ valleylabexchange, select the Valleylab™ FT10 Energy Platform, and download the Software Update Tutorial... Software Package Download IMPORTANT You must download software packages before starting the software update... our computer must be connected to the Internet before launching Valleylab™ Exchange... OTE Do not connect the generator to your computer until instructed... ocate the VLEXClient icon and double-click it to start the software... onfirm a green indicator showing Online mode in the lower-right corner... ign in with your username and password... eselect (uncheck) any generators you are not working with... lick Apply... he software packages will download automatically... STEP 3  4... n the Server Download screen, select Valleylab™ FT10 from the drop-down list and click Go... hen the download is complete, the Package Bundle Download Status will show Completed... lick Logout in the upper-right corner of the screen... STEP 5  7... fter logout is complete, click the in the upper-right corner of the screen to close the Valleylab™ Exchange application... Please see back...  Software Update IMPORTANT While using Valleylab™ Exchange, only one generator may be connected to your computer... ain access to the Ethernet port through the back cover plate of the generator... lug the Ethernet cable into your computer and port at the back of the generator... urn on the Valleylab™ FT10 Energy Platform... nce the generator boots up, push the Service/Settings button  below the generator touchscreen... 4... n the touchscreen select: System, Network, then Wired Point-to-point... nce the Wired Point-topoint button is greyed out and Network Status displays RUNNING, the generator is connected... Network Status: RUNNING  ➧  ➧  5... ocate the VLEXClient icon on your desktop and double-click it to start the software... ign in with your username and password... eselect (uncheck) any generators you are not working with... lick Apply... hen the green status bar is at 100%, click Software Update on the left-hand menu... en the green status bar is at 100%, click Software Update on the lefthand menu... lick Update... STEP 7 A Software Update has been requested Begin Software Update  CANCEL  STEP 9  Update  IMPORTANT While using Valleylab™ Exchange, only one generator may be connected to your computer... hen the green status bar is at 30%, “A Software Update has been requested” will display on the generator touchscreen... elect Begin Software Update... OTE If you do not select Begin Software Update within 5 minutes the software update process will time out... 0... hen the green status bar is at 70%, the generator will automatically restart... 1... hen the green status bar is at 100%, the software update process is complete... lick Logout in the upperright corner and close the application... isconnect the Ethernet cable and replace the back cover plate... STEP 11 For additional information or technical support, please visit http://surgical... vidien... m/service-centers to locate a Covidien Service Center near you or e-mail valleylab... chnicalservice@covidien... m  COVIDIEN, COVIDIEN with logo and Covidien logo are U...  and internationally registered trademarks of Covidien AG... ther brands are trademarks of a Covidien company... 2015 Covidien 10...  US150763(1) ref#424268  5920 Longbow Drive Boulder, Colorado 80301  303-530-6100 800-255-8522  Covidien... m/ValleylabExchange
File Type: PDF
File Size: 672 KB
File Name: FT10 Software Update Guide .pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions