ZIMMER

Dermatomes

Tissue Bank Dermatone Instruction and Service Manual REF 8831-001 Revised May 2005

Instruction and Service Manual

12 Pages

ZIMMER™ Tissue Bank Dermatome FOR CADAVER USE ONLY Instruction and Service Manual REF: 8831-001  STORAGE The Zimmer Tissue Bank Dermatome has an operating temperature range of 50° to 88°F (10° to 31°C). The following are environmental conditions for transportation and storage: A. Ambient temperature range...1°F to 149°F (–17°C to 65°C) B. Relative humidity range...10% to 80% C. Atmospheric pressure range...500 hPa to 1060 hPa  GENERAL DESCRIPTION The Zimmer Tissue Bank Dermatome is an electrically powered instrument designed specifically for tissue retrieval procedures. It is intended for use on cadavers only, and not for living patients requiring skin grafts.  RECEIVING INSPECTION  This instrument is designed for retrieving tissue in thicknesses ranging from 0 to .060 in. (0 to 1.52 mm) in .004 in. (.102 mm) increments. It also allows a choice of either 3 or 4 in. (7.6 and 10.2 cm) skin widths using the two width plates included. Two stainless steel machine screws secure the plates to the underside of the instrument. The plates are easily fastened and removed with the screwdriver provided.  After receiving the Zimmer Tissue Bank Dermatome, examine the unit for external signs of damage. Retain all packing material until the contents have been verified and an initial operational check has been performed. If the device has been damaged, forward an immediate request to the delivering carrier to perform an inspection and prepare a "Concealed Damage" report. The terms of all Zimmer Orthopaedic Surgical Products sales agreements concerning this unit are F.O.B., Dover, Ohio, U.S.A., and the responsibility of Zimmer Orthopaedic Surgical Products ends with delivery to the first carrier. Thereafter, the shipment becomes the property of the customer. Any claims for loss, damage, or non-delivery must be made against the delivering carrier within 10 days of shipment.  This dermatome is powered by an ironless rotor, low inertia motor, which provides nearly vibration-free power.  SPECIFICATIONS 1. POWER SUPPLY I. Physical: Weight: Dimensions:  II. Electrical: Power Requirements: Power Output:  Your Zimmer distributor or local Zimmer representative will assist you in determining the cost of replacement or repair so that a proper claim may be filed with the delivering carrier.  2.6 lb. (1.18 kg) 9.12 in. (23.2 cm) Length 5.44 in. (13.8 cm) Height 6.69 in. (17.0 cm) Depth  Note: Do not attempt to return damaged goods without first securing proper authorization from the delivering carrier.  100-240 V~ (Auto Switching) 150 VA, 50/60 Hz Single Phase 14.5 V , 4.3 A Maximum  GENERAL PRECAUTIONS This equipment is for use only by qualified tissue bank personnel. To avoid serious injury to the tissue bank staff when using the Zimmer Tissue Bank Dermatome, the operator must be thoroughly familiar with its function, application, and instructions before use. The handpiece and blade must be inspected for proper operation before use. If you have any questions, please contact your Zimmer representative.  2. HANDPIECE I. Physical: Weight: Dimensions: Vibration and Shock: Cutting Speed: II. Electrical: Power Requirements:  2.9 lb. (1.31 kg) 9.75 in. (24.8 cm) Length 5.2 in. (13.2 cm) Width Standard Commercial Practice 5000–6000 Cycles/Minute  Ground reliability can only be achieved when the hospital grade power cord is connected to a proper receptacle. NEVER connect the Zimmer Tissue Bank Dermatome Handpiece to any source other than the Zimmer Tissue Bank Dermatome Power Supply. It has been factory calibrated to provide optimum cutting performance and maximum safety. It is also designed to meet or exceed specific medical electrical safety standards.  14.5 V , Fully Regulated and Isolated, 4.3 A Maximum  UL 60601-1 Classification: Type of protection against electrical shock  For continued protection against fire hazard, replace only with the same type and rating of fuse. (Refer to FUSES section.)  Class I  Degree of protection against electrical shock: Type BF applied part Classification according to the degree of protection against ingress of water:  IPXO  Mode of operation:  50% Duty Cycle, 10 minute maximum ON 88°F (31°C)  Maximum operating ambient:  Possible explosion hazard exists if this instrument is used in the presence of flammable anesthetics or gases. NEVER sterilize the power supply. Disconnect the dermatome handpiece from the power supply before sterilization. -1-
File Type: PDF
File Size: 617 KB
File Name: tissue_bank_dermatone_instruction_and_service_manua.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions