3M ESPE

Curing Lights

Elipar DeepCure-L Curing Light Operating Instructions

Operating Instructions

130 Pages

Elipar™ DeepCure-L LED Curing Light  Table of Contents  Page  Safety Instructions  1  Glossary of Symbols  2  Product Description  3  Fields of Application  3  Technical Data Charger Handpiece Charger and Handpiece Transport and Storage Conditions  3 3 3 4 4  Installation of the Unit Factory Settings Initial Steps Charger Light Guide/Handpiece Battery Charging Battery Power Level Display on Handpiece  4 4 4 4 4 4 5  Operation Selection of Exposure Time Activating and Deactivating the Light Inserting and Removing the Light Guide from/into the Handpiece Positioning the Light Guide Testing of Light Intensity Sleep Mode Audible Signals - Handpiece  5 5 6 6 6 6 7 7  Troubleshooting  7  Maintenance and Care Care of the Handpiece Cleaning the Light Guide Clean Handpiece and Glare Shield Storage of the Handpiece during Extended Periods of Non-Use  8 8 8 9 9  Return of Old Electric and Electronic Equipment for Disposal  9  Customer Information Warranty Limitation of Liability  10 10 10  PLEASE NOTE! Prior to installation and start-up of the device, please read these instructions carefully. As with all technical devices, the proper function and safe operation of this device depend on the user’s compliance with the standard safety procedures as well as the specific safety recommendations presented in these Operating Instructions. 1. Use of the device is restricted to trained personnel in accordance with the instructions below. The manufacturer assumes no liability for any damage arising from any other or improper use of this device. 2. The charger must be accessible at all times. Do not use the charger for any use other than the charging of the Elipar™ DeepCure-L handpiece. Disconnect the handpiece from the mains by unplugging the charger from the electrical outlet. Treating patients using the handpiece while it is still connected to the charger is prohibited for safety reasons. Light-curing is possible only if the charger has been disconnected. 3. Use only the charger (AC adapter plug) which is provided with the device. The use of any other charger can result in damage to the battery. 4. CAUTION. Do not stare at source. May be harmful to the eyes. Restrict exposure to the area of the oral cavity in which clinical treatment is intended. Protect patient and user from reflection and intensive scattered light by taking the appropriate precautions, e.g., glare shields, goggles, or coverings. 5. CAUTION! As is the case for all high-intensity lightcuring devices, the high light intensity is accompanied by heat generation on the exposed surface. This heat can result in irreversible damage if there is longer exposure in the proximity of the pulp or soft tissue. The exposure times given in the manufacturer’s instructions must be observed exactly to avoid any such damage. Uninterrupted exposure times of the same tooth surface in excess of 20 seconds and direct contact with oral mucosa or skin must be strictly avoided. Scientists working in this field are in agreement that the irritation caused by heat generated during light curing can be minimized by taking two simple precautions: • Polymerization with external cooling from an air flow • Polymerization at intermittent intervals (e.g., 2 exposures lasting 10 seconds each instead of 1 exposure lasting 20 seconds). 6. Elipar DeepCure-L may be operated only with the supplied light guide or original 3M ESPE Elipar DeepCure-L replacement and accessory light guide. 1  en ENGLISH   Safety Instructions  en ENGLISH 
File Type: PDF
File Size: 4.84 MB
File Name: Elipar_ DeepCure-L Curing Light IFU.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions