Page 1
REFERENCE COPY ONLY – DO NOT DISTRIBUTE Refer to the Product Lifecycle Management system for the latest revision.
REVISION HISTORY REV
ECN/CN #
IMPLEMENTED BY / DATE
APPROVED BY / DATE
P3
--
A
CN073152ECN
Gerard Scortino / 9-5-2017
Jeff Naemura / 9-5-2017
B
CN075260ECN
Troy Hinzman / 10-20-2017
Gerard Scortino / 10-20-2017
C
CN075367ECN
Troy Hinzman / 10-23-2017
Jeff Naemura / 10-23-2017
TEXT FOR THE CONSTELLATION* VISION SYSTEM ADDENDUM FOR USE WITH THE NGENUITY* 3D VISUALIZATION SYSTEM
NOTES: 1. This is a cover sheet for addendum revision only and is not a sheet to be included as part of the addendum. 2. Print Addendum text on white, 32lb, 8 1/2" x 11", 3-hole punched paper, shrink-wrapped with cardboard backing. 3. Inspect per Generic QIP Manual. 1 4. Safety critical component.
SHEET 1 of 5
BY
Troy Hinzman CHECKED Gerard Scortino APPROVED Mark Hopkins
DATE 6/14/17
TITLE ADDENDUM,CONST-NGENUITY
6/14/17 6/20/17
IRVINE, CA 92618-3818
DWG NO.
905-2120-101
REV
C
REFERENCE COPY ONLY – DO NOT DISTRIBUTE Refer to the Product Lifecycle Management system for the latest revision.
ADDENDUM
This addendum is shipped for your convenience with the NGENUITY* Visualization System Upgrade, which is used exclusively with the Constellation* Vision System. Please note that this addendum is designed to supplement your Constellation* Vision System operator’s manual, rather than to be used as an independent manual; therefore, place this addendum in your Constellation* Vision System operator's manual behind the “Accessories and Parts” divider.
CONSTELLATION* VISION SYSTEM ADDENDUM FOR USE WITH THE NGENUITY* 3D VISUALIZATION SYSTEM
Manufacturer: Alcon Laboratories, Inc. 6201 South Freeway Fort Worth, Texas 76134-2099 U.S.A. Telephone: 949/753-1393 800/832-7827 FAX: 949/505-6614
EC
REP
Alcon Laboratories (UK) Ltd. Frimley Business Park Frimley, Camberley Surrey, GU16 7SR, United Kingdom
* A trademark of Novartis ** Trademarks are the property of their respective owner.
905-2120-101 Rev. C 905-2120-101
© 2017 Novartis A-1
REFERENCE COPY ONLY – DO NOT DISTRIBUTE Refer to the Product Lifecycle Management system for the latest revision.
GENERAL INFORMATION
Introduction The NGENUITY* 3D Visualization System (NGENUITY* system) is a device that can be connected to the Constellation* Vision System (Constellation* system) or used as a standalone system. When connected to the Constellation* system, surgical parameters from the Constellation* system can be overlaid on the NGENUITY* system and video recording by the NGENUITY* system can be initiated by the Constellation* footswitch.
Warnings and Cautions
Labels
Refer to the respective Constellation* system and NGENUITY* system operator's manuals for comprehensive lists of warnings and cautions. Refer to the respective Constellation* system and NGENUITY* system operator's manuals for detailed information on labeling and technical specifications.
System Requirements
NGENUITY* System: Must have software version 1.2.7 or above. Constellation* System: Must have High Definition Video Overlay installed. Connecting the Constellation* Vision System to an NGENUITY* 3D Visualization System Please contact Alcon Technical Services for installation.
The NGENUITY* system can be connected to the Constellation* system to make use of the High Definition Video Overlay capability of the Constellation* system. This feature replicates some of the display values and parameters from the Constellation* screen onto the periphery of the NGENUITY* screen. The following information describes the hardware and software configuration for the NGENUITY* system connection to the Constellation* system. 1. HARDWARE SETUP 1.1 Connect the following cables to the connector panel on the rear of the Constellation* system. Refer to Figure A-1 for connector location. A - Connect (HDMI** Cable 2) Rx USB connector to Constellation* USB port. B - Connect (HDMI** Cable 2) Rx HDMI** connector to Constellation* HDMI** input port. C - Connect Long DB-9 serial data cable to RS-232 port. D - Connect (HDMI** Cable 1) Tx HDMI** connector to HDMI** output port.
1.2
Connect HDMI and RS-232 cables to the back of the EPU as shown in Figure A-1. E - RS-232 cable connects to COM2 port on EPU. F - Connect (HDMI** Cable 1) USB Rx connector to USB 2.0 connector on EPU. G - Connect (HDMI** Cable 2) HDMI** Tx connector to HDMI** secondary video output on EPU. H - Connect (HDMI** Cable 1) HDMI** Rx connector to HDMI** port at the bottom-left of EPU.
NOTE: Excess cable length may be coiled and stored in the EPU compartment. Coiled cabling should be positioned to avoid obstructing air flow and causing overheating. A-2
905-2120-101
REFERENCE COPY ONLY – DO NOT DISTRIBUTE Refer to the Product Lifecycle Management system for the latest revision. *
NOTE: First, the Constellation system must be turned on, then, no longer than 20 seconds later, the NGENUITY* system must be turned on, otherwise, the Video Overlay will not display properly.
1.3 1.4
Power on the Constellation* system. Power on the NGENUITY* system within 20 seconds of the Constellation* system.
HDMI video input connection from NGENUITY* HDMI** output connector.
A (Rx) C
B (Rx)
Constellation* Vision System Rear Panel (system with High Definition Video Overlay)
D (Tx) HDMI video output connection (Tx) to NGENUITY* HDMI** connector.
Serial port connection to NGENUITY* EPU COM2 port.
HDMI** Cable 2
Serial port connection provides start/stop video recording on the NGENUITY* system via the Constellation* Footswitch.
NGENUITY* 3D Visualization System
HDMI** Cable 1
NGENUITY* EPU
E- RS232
F- USB Power (Rx)
G- HDMI** (Tx)
H- HDMI** (Rx)
Open the NGENUITY* side panel for access to the EPU.
Figure A-1 905-2120-101
NGENUITY* to Constellation* System Connection Diagram A-3
REFERENCE COPY ONLY – DO NOT DISTRIBUTE Refer to the Product Lifecycle Management system for the latest revision.
2. CONSTELLATION SOFTWARE SETUP 2.1 Enable Video Overlay 2.1.1 Tap the Options button, then tap the Video Overlay tab. 2.1.2 Under Video Overlay, tap Enabled. 2.1.3 Tap Save. 2.2 2.2.1 2.2.2 2.2.3 2.2.4 2.2.5
Map Constellation* Footswitch to Toggle Video Recording (Optional) Tap the footswitch icon at the top-left of display. Tap the Configure button. Map one button on footswitch to Toggle Video Recording. Tap Apply to All Modes. Tap Save.
3. NGENUITY* SYSTEM SETUP
NOTE: When the Constellation* system is connected and Video Overlay is enabled, the secondary monitor settings are automatically configured for the overlay. In this configuration, output to a secondary monitor is not available.
3.1
Click the wrench button to display the system settings. Display of * Constellation system settings overlaid on the main NGENUITY* system display can be enabled here.
3.2
Click the Constellation* button and check the Overlay Constellation* box to turn on the Constellation* settings overlay.
3.3
Click the Input Source button to HDMI.
and confirm that View 2 input source is set
NOTE: For troubleshooting information, refer to the NGENUITY* system operator's manual.
ACCESSORIES AND PARTS Table A-1 is a list of additional Alcon‑approved accessories and replacement items. Use of non‑approved accessories is not permitted. Please contact the Alcon Sales Department for in-service information prior to initial use of handpieces, accessories, or packs. For additional information, please contact the Alcon Sales Department. Write: Alcon, Inc. 6201 South Freeway Fort Worth, TX. 76134‑2099
Phone: (800) 862‑5266 or (817) 293‑0450 Ask for Customer Service
INTERNATIONAL: Please contact your local Alcon Sales Office. Table A-1
Accessories and Parts DESCRIPTION
A-4
SUPPLIED BY
CATALOG NUMBER/SUPPLIER NUMBER
NGENUITY* System
Alcon
8065753090
CABLE ASSY, NGENUITY* 1.2A BNDL
Alcon
204-1042-001
NGENUITY* Dust Cover
Alcon
8065753076
LAST PAGE OF ADDENDUM
905-2120-101