ENDOSCOPE CLEANING GUIDE for EVIS EXERA III Duodenovideoscope TJF-Q190V  All steps of cleaning for endoscope are done in detergent solution or water completely, except for flushing with air and drying the external surfaces at the end of cleaning.  WARNING WARNING This workflow is a summary of the cleaning steps necessary to properly reprocess your TJF-Q190V and does not include disinfecting/sterilizing steps. Follow the detailed steps instructed in the latest ENDOSCOPE REPROCESSING MANUAL for TJF-Q190V. * The handle of the single use combination cleaning brush (BW-412T) or the brush handle of the channel-opening cleaning brush (MH-507) ** The channel cleaning brush part of the single use combination cleaning brush (BW-412T) or the channel cleaning brush (BW-20T)  Clean the external surfaces  1  Brush the distal end of the endoscope  2  Detergent solution  ×3  Before "Cleaning the external surfaces", "Precleaning" and "Leakage testing" should be done as described in the reprocessing manual.  * ×3 ×3  ×3  The forceps elevator and the forceps elevator recess  Brush the distal end of the endoscope  Left side surface  Right side surface  Brush the suction cylinder & the instrument channel port  Brush the instrument channel and suction channel  3  4  5  Back side surface  Flush the distal end  6  7  30 ml  20  ml  *  30 ml ×5 ml  Distal surface  30  Lens side surface  10  ml  **  ×1  10m  l  l 20m  30m  l  ** Repeat the flushing steps from the green flushing port also  Flush the distal end  Aspirate detergent solution  8  9  Flush the air/water channel  10  30 sec  Immerse in detergent solution  Remove detergent solution  11  12  Water  30 ml ×3 ×3 ×3  Remove detergent solution  14  15  30 ml ×2  16  17  Air  ml 30  30 ml  30 ml ×3  30 ml ×3  ml 10  m 20  l  13  Dry the external surfaces  10m  l  20m  l  30m  l  ×1  Repeat the flushing steps from the green flushing port also  For complete product details see Instructions for Use.  OLYMPUS AU STRALIA PTY LTD 3 Acacia Place, Notting Hill VIC 3168, Australia Customer Service: 1300 132 992 | www.olympusaustralia.com.au  OLYMPUS NEW ZEALAND LIMITED 28 Corinthian Drive, Albany, Auckland NZ 0632 Customer Service: 0508 659 6787 | www.olympus.co.nz QR 07.306 V1.0 November 2019
File Type: PDF
File Size: 3.19 MB
File Name: OLYMPUS - QR 07.306 - ENDOSCOPE CLEANING GUIDE - 2019-11 - V1.0.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions