ARCOMA
0047-TM5(H)SCU Technical Manual Rev NC
Technical Manual
22 Pages
Preview
Page 1
TECHNICAL MANUAL 0047-TM5(H)SCU C-Arm Imaging Table
Arcoma-Elite Version SCU Rev NC
0047- TM5(H) A
Contents
Contents Contents………………………………...…A-1 Introduction………………………………..…1 Important note……………………………………….1
System modes of operation……………….2 General……………………………………………….2 Range of application……...……………………...…2
Safety……..………………..………………….3 General…..…………………………………………..3 Warranty …………………..………………………A3
Safety continued…..……..………………….4 Maintenance…………………………………………4 Checks, test………………………………………….4 Installation, repair……………………………………4
Cleaning………………………………………5 Function and safety checks…….…...……6 Daily checks……………………….…………………6 Monthly checks………………………………………6 Annual maintenance……………..…………………6
Operating the table………………….………7 General……………………………………………….7 Controlling the table…………………………………7
Protective measures…………………...……8 Mechanical safety…………………………...………8 Safety-relevant parts subject to wear……..………9 Waste disposal………………………..…………….9
Location of Identification label.………..…10
0047 TABLES
Arcoma-Elite Version SCU Rev NC
A-1
0047- TM5(H) A
Contents Technical Specifications..………… ………11 General…..……………………………….…………11 Operating environment…….……………………...12 Classifications….………………………………..…12 How to use the wrench……….…..…………….. 13 Spare parts………………….……………………...14 Electrical schematics.….……………………15 & 16
Parts List……………..………………………..17 Table Movement Calibration Procedure..18
NOTE: Emergency Stop Switch
Location of Emergency “STOP” Switch
Before using the table for the first time, please make sure that the emergency stop switch has not been pushed in during transportation or uncrating. If the table movements do not function twist the emergency switch clockwise as indicated on the switch the table movements should then function correctly
A-2
Arcoma-Elite Version SCU Rev NC
0047 TABLES
0047- TM5(H) A
Introduction
WARRANTY: Limited Part Warranty: With the exception of the parts specifically noted below, there is a 36 month from date of shipment warranty on mechanical and electrical components which fail due to normal use of the product. The warranty does not apply to failure due to mis-use of the product. The warranty covers replacement of the defective part including shipping charges. Parts Excluded From the 36 Month Warranty: The following parts are covered under a 12 month warranty from the date of shipment; (1) Carbon Fiber Table-top, (2) Hand Control Unit, and (3) Table Accessories which fail due to normal use of the product. The warranty does not apply to failure due to mis-use of the product. The warranty covers replacement of the defective part including shipping charges. Labor Warranty: The warranty includes labor to repair/replace all components which have failed due to manufacturing defect during the first 12 months from the date of shipment. The warranty does not apply to components that have failed due to mis-use of the product. Warranty Replacement Parts: If requested by Arcoma, parts claimed under warranty replacement must be returned to Arcoma. If the part is not returned within 30 days or upon inspection by Arcoma in its sole judgement the part is deemed to have failed due to product mis-use the customer will be billed for the part in accordance with the then current published spare part price list. LIMITATIONS: In no event shall Arcoma be Liable for any special, incidental, consequential or indirect damages of any kind, regardless of whether customer knew or should have known of the possibility of such damages. More specifically, in no event, notwithstanding anything in this agreement to the contrary, shall Arcoma or its directors, officers, employees, owners, agents or affiliates (collectively “agents”) be responsible or liable to customer or any other party for lost profits, lost revenues, lost business opportunities or other economic loss or damage, or for indirect, incidental, special, punitive or consequential damages, whether based on contract, tort or other legal or equitable theory, arising out of or in connection with this sale, even if they have been advised of the possibility of such damages or if such damages could have been reasonably forseen, and notwithstanding any failute of essential purpose of any limited remedy.
0047 TABLES
Arcoma-Elite Version SCU Rev NC
A3
0047- TM5(H) A
Introduction
Introduction Important note Using the Arcoma “Medstone-Elite” Tables presupposes that the operating personnel is thoroughly familiar with the operating instructions. •
Safety (page 3)
•
Function and safety checks (page 5)
•
Protective measures (page 9)
Document Information It is important that this document kept for the life of the equipment and transferred to any subsequent holder or user of the equipment. Document producer This document has been produced by: Arcoma North America, Inc. 23112 Alcalde Drive, Suite A Laguna Hills, California USA 92653 Tel: 949-457-1231
Copyright © 2009 ARCOMA North America, Inc. The reproduction, transmission or use of this document or its content are not permitted without expressed written consent. Offender will be liable for damages. All rights, including rights crated by patent grant or registration of a utility model or design are reserved.
Text emphasis
!
WARNING! All text labeled “WARNING” calls attention to potential risk to health or life
0047 TABLES
Arcoma-Elite Version SCU Rev NC
1
0047- TM5(H) A
ystem modes of operation
System modes of operation General 0047-Series mobile tables are used for imaging applications. The tables, depending on your option are provided with several actuators and motorized column giving the tables good movement range.
A A B A
Figure 1. 0047-TM5 (shown) A Table Top
B Actuator/Lift
Shown without covers
Range of application The intended use of the table is for examinations and imaging (‘C; Arm required)only. Medical staff must supervise the equipment when it is in use near the patient.
2
Arcoma-Elite Version SCU Rev NC
0047 TABLES
0047- TM5(H) A
Safety
Safety General CAUTION! This device is restricted to use by or on the order of a physician. The device is intended for use in radiographic examinations under the guidance of trained health care professionals. Operating personnel must be familiar with the equipment and the instructions given in this manual before using it.
0047 TABLES
Arcoma-Elite Version SCU Rev NC
3
0047- TM5(H) A
Safety
Safety Maintenance To ensure the safety of the patients, the operators, and third parties, the equipment must be checked every 12 months to maintain its reliability and serviceability.
Checks, test Checks and tests that shall be performed with specified intervals are described in Function and safety checks (page 5)
Installation, repair Modifications of, or additions to the product must be made in accordance with the legal regulations and generally accepted engineering standards. The supplier cannot assume responsibility for the safety features and for the reliability and performance of the equipment, if: •
installation, equipment expansions or modifications are not carried out by persons authorized by us.
•
components affecting safe operation of the unit are not replaced by original spare parts in case of a malfunction.
•
the product is not used in accordance with the operating instructions.
On request, we will make technical documents for the product available to you at a charge that will be invoiced. This does not imply an authorization to undertake repairs. We accept no responsibility for repairs performed without our expressed written approval. We suggest that you obtain a report indicating the nature and extent of the work performed from the persons carrying out such work, and specify that the report shows any changes in rated parameters or operating ranges, as well as date, the name of the firm and a signature.
4
Arcoma-Elite Version SCU Rev NC
0047 TABLES
0047- TM5(H) A
Cleaning
Cleaning CAUTION! Surfaces that are in contact with the patient shall be cleaned with a lint free cloth dampened with a small amount of soapy water or cleaning solution.
Approved products and methods for cleaning and disinfecting of table and stretcher pads CLEANING OF SOILS & STAINS Wash with generous application of neutral soap suds and lukewarm water. Rinse with water and dry. Do not immerse. Or Use a diluted bleach solution of 10-parts water to1-part bleach. Wipe dry with clean cloth. Do not immerse. Bleach must be diluted to the 10:0 ratio.
DISINFECTING Use Lysol I.C. Disinfectant Spray by National Laboratories, Moontvale, New Jersey, per manufacturer’s instructions Reference: National Labortories Item # 95029-000 Or
Use a diluted bleach solution of 10-parts water to1-part bleach. Wipe dry with clean cloth. Do not immerse. Bleach must be diluted to the 10:0 ratio.
DO NOT APPLY TAPE TO ANY PAD The following Steris products are also approved for use in cleaning and disinfecting our pads: • • •
Steris Coverage Plus wipes 1608-WC, 1608-GS and 1608-G4 Steris Coverage Spray HB Plus 1624-77 Steris Coverage Spray TB Plus 1629-B4 and 1629-08
0047 TABLES
Arcoma-Elite Version SCU Rev NC
5
0047- TM5(H) A
Function and safety checks
Function and safety checks If any malfunction is detected, the entire equipment must be taken out of use until a service engineer from the supplier eliminates the malfunction or by local technical staff trained by the supplier.
Daily checks When necessary, clean according to Cleaning (page 4).
Monthly checks •
Check the legibility of the label according to section Location of Identification label (page 11). If any label must be replaced, please notify the supplier customer service.
•
Power up the stand and check all functions according to Technical Specifications (page 12).
Annual maintenance The following maintenance is necessary to perform every 12 months to keep the equipment safe and operational. •
Power up the stand and check all functions according to Technical Specifications (page 12).
•
Check parts according to Safety-relevant parts subject to wear (page 10).
6
Arcoma-Elite Version SCU Rev NC
0047 TABLES
0047- TM5(H) A
Operating the table
Operating the table General CAUTION ! Make sure that all wheels are locked before the patient is placed on the table. USE OF PATIENT RESTRAINT IS REQUIRED DURING USE.
Controlling the table The table movement is controlled with the hand switch in accordance with the following figures. Figure 2
LONGITUDINAL DRIVE
LONGITUDINAL TRAVEL
TREN'BURG TILT
TRENDELENBURG TILT
UP/DOWN ELEVATION
LIFT
LATERAL TILT
CROSS TABLE DRIVE
LATERAL TILT
LATERAL TRAVEL
PL10-0001-005 NC
0047-TM5 REMOTE HAND CONTROL AND FOOT SWITCH (OPTIONS ARE AVAIABLE) 0047 TABLES
Arcoma-Elite Version SCU Rev NC
7
0047- TM5(H) A
Protective Measures
Protective measures Mechanical safety It is the operator’s duty to ensure that any danger to the patient or third parties is precluded before movements are released. possible hazard areas are indicated in the figure below.
Figure 3. Possible Hazard Areas
Figure 4 Use three (3) patient restraints to protect patient from injury
8
Arcoma-Elite Version SCU Rev NC
0047 TABLES
0047- TM5(H) A
Preventative Maintenance Procedures Preventative Maintenance 1. Preventative maintenance should be performed every six (6) months, checking the following items: 2. Table-top mounting bolts, check to make sure they are tight 3. Actuator mounting bracket bolts are tight and that the actuator pin(s) retention spring clips are securely in position 4. Test movements of all Actuators and Elevation Lifts to insure that they are moving freely and smoothly 5. On all table that have longitudinal travel (extend and retract) check that the Rollon bearing slides are moving freely and smoothly 6. On 004-TM5 (5-movement) model versions, check to make sure that the lateral movement linear slide bearing rails are clean and that the cross table movement is moving freely and smoothly 7. “Emergency Stop Switch”, check that it is functioning correctly, that all movements are disabled when pressed 8. Hand Control, check that all push button movements are functioning correctly 9. (Optional) Foot Control Switch, check that all movements are functioning correctly and that the spring loaded switches are not sticking in the “ON” positions
Safety-relevant parts subject to wear This unit contains the following safety-relevant parts, which should be checked by service personnel according to the following: •
Tightening of bolts: Bolt Size
Torque Tightness
M6 M8 M12 M4
6 Ft Lbs 16 Ft Lbs 60 Ft 30 Ft Lbs - Table Top 21 In Lbs
0047 TABLES
Arcoma-Elite Version SCU Rev NC
9
0047- TM5(H) A
Location of Identification label
Location of Identification label
Location of Certification and Serial Number Label Model 0047-TM5H-ER
Figure 4. Location of Identification label
10
Arcoma-Elite Version SCU Rev NC
0047 TABLES
0047- TM5(H) A
Technical specifications
Technical specifications General Table top size
22” (559 mm) x82” (2083 mm)
Model number Table top movement, Lateral tilt Table top movement, Elevation Table top movement, Trendelenburg Travel Longitudinal Travel Lateral Weight
0047-TE N/A 300mm N/A N/A N/A 500 lbs 227 kg
0047-TT N/A 300mm +15°/-15º N/A N/A 550 lbs 250 kg
0047-TL ± 15°, 300mm N/A N/A N/A 550 lbs 250 kg
0047-TM3 ± 15°, 300mm +15°/-15º N/A N/A 600 lbs 273 kg
0047-TM4 ± 15°, 300mm +15°/-15º 400mm N/A 650 lbs 295 kg
0047-TM5 ± 15°, 300mm +15°/-15º 400mm 150mm 600 lbs 295 kg
400mm Travel
150mm Travel
15o 15
o
300mm Travel
Figure 5. Table Movement Range
0047 TABLES
Arcoma-Elite Version SCU Rev NC
11
0047- TM5(H) A
Technical specifications
Technical specifications External power supply
Power supply Power consumption
120 VAC, 50 – 60 Hz or 230VAC, 50 Hz 9 Amps, 4.5 Amps
Operating environment
Operating temperature Storing temperature Operating and storing humidity Patient weight limit
+10° - +30° C -20° - +40° C 30 – 80 % relative humidity, non condensing 500 lbs, (227 kg) evenly distributed
Classifications
Protection against electrical shock
Duty factor Mode of operation Degree of safety of apllication in the presence of flammable anaesthetic mixture with air or nitrous oxygen
12
Arcoma-Elite Version SCU Rev NC
Type B according to degree of protection (IEC 601-1) Class 1 according to type of protection (IEC 601-1) EMC-disturbances can appear even if the product complies with the EMC demands 15% Continuous operation with intermittent loading Not suitable for use in the presence of flammable anaesthetic mixtures.
0047 TABLES
0047- TM5(H) A
0047 TABLES
Arcoma-Elite Version SCU Rev NC
13
0047- TM5(H) A
Recommended Spare Parts ITEM NO.
QTY.
PART NO.
DESCRIPTION
1
1
29-101
TABLE-PAD
2
4
50-253
TENTE CASTER -5” (125MM)
3
1
06-275/277
SWITCH – EMERGENCY STOP
4
1
0047-810-205
HAND SWITCH
5
1
50-253
POWER CABLE (110 VAC)
6
1
50-253
POWER CABLE (230 VAC) SCHUKO
7
1
50-146
POWER CABLE (230 VAC)- UK
14
Arcoma-Elite Version SCU Rev NC
0047 TABLES
0047- TM5(H) A
0047 TABLES
Arcoma-Elite Version SCU Rev NC
15
0047- TM5(H) A
Lat Trav left Long Foot
The document contains Confidential and Proprietary information of Arcoma-na inc., and all design, manufacturing, reproduction, use, and sale rights in such information are expessly reserved.
CONFIDENTIAL AND PROPRIETARY INFORMATION
Tren up
Elev Up Tren Down
Elev Down
3 4 5 6 7 8 9 10
3 4 5 6 7 8 9 10
COMUNICATIONS
12
13
BATTERY NOT 14 USED
OPERATIONAL UNITS HAND & FOOT CONTROLS
10
50-184, SCU58-003230-000 Motor Control Box
INCOMING 11 POWER
8
2
2
9
1
1
50-186, EHA35-23N50N-000
Long Lat Tilt Lat Tilt left Head Right
Hand Control Pandent
Lat Trav Right Elev Down
Tren up Long Head
Lateral Tilt
2
APPROVED
CHECK BY
DRAWN BY
BWG
APPROVALS
Lat Trav left
5/1/13
DATE
-0009
Lat Trav Right
NONE
SHEET 2 OF 2
0047-010-0009
DRAWING NO.
ELECTRICAL SCHEMATIC 0047-TM5(H)SCU
SCALE
A
SIZE
TITLE
GND
120VAC 0
120 VAC Operation
50-189, 150mm Actuator
50-188, 70mm Actuator
50-192, Lift Drive
50-185, 100mm Actuator
50-191, 400mm Actuator
E-STOP
Earth Ground lug on chassis
Cross Table Drive Left - Right
Elevation Down - up
3
Elevation Down - up
4
Longitudinal Travel Head-Foot Trendelenburg Head down - Head up
1
Long Foot
NEW RELEASE
NC
REVISIONS DESCRIPTION
REV
SCU Footswitch Control
Lat Tilt Lat Tilt Right left
(OPTIONAL)
Elev Up
5
6
Tren Down
DASH NO.
ACTUATOR MOTOR PLUGS
REV
NC
16
Arcoma-Elite Version SCU Rev NC
0047 TABLES
0047- TM5(H) A
Lat Trav left Long Foot
The document contains Confidential and Proprietary information of Arcoma-na inc., and all design, manufacturing, reproduction, use, and sale rights in such information are expessly reserved.
CONFIDENTIAL AND PROPRIETARY INFORMATION
Tren up
Elev Up Tren Down
Elev Down
3 4 5 6 7 8 9 10
3 4 5 6 7 8 9 10
COMUNICATIONS
12
13
BATTERY NOT 14 USED
OPERATIONAL UNITS HAND & FOOT CONTROLS
50-195, SCU96-003230-000 Motor Control Box
INCOMING 11 POWER
8
2
2
9
1
1
10
50-186, EHA35-23N50N-000
Long Lat Tilt Lat Tilt left Head Right
Hand Control Pandent
Lat Trav Right Elev Down
Tren up Long Head
Lateral Tilt
2
DRAWN BY
APPROVED
CHECK BY
BWG
APPROVALS
5/1/13
DATE
-0009
Lat Trav left
Lat Trav Right
NONE
SHEET 2 OF 2
0047-010-0009
DRAWING NO.
SCALE
A
SIZE
230 VAC Operation
GND
120VAC 0
ELECTRICAL SCHEMATIC 0047-TM5(H)SCU
E-STOP
50-189, 150mm Actuator
50-188, 70mm Actuator
50-192, Lift Drive
50-185, 100mm Actuator
50-191, 400mm Actuator
TITLE
(European use only – Green/Yellow Ground/Earth)
Earth Ground lug on chassis
Cross Table Drive Left - Right
Elevation Down - up
3
Elevation Down - up
4
Longitudinal Travel Head-Foot Trendelenburg Head down - Head up
1
Long Foot
NEW RELEASE
NC
REVISIONS DESCRIPTION
REV
SCU Footswitch Control
Lat Tilt Lat Tilt Right left
(OPTIONAL)
Elev Up
5
6
Tren Down
DASH NO.
ACTUATOR MOTOR PLUGS
REV
NC