ATOM Medical Corporation

Incubators

i series Incubators Recommended Chemicals for Cleaning and Disinfection Guideline Nov 2016

Guideline

1 Page

Hood (Inc. Access port)  Mattress  Mattress platform (Inc. X-ray tray)  Mattress platform tray  Middle board  Tilting arm  Conditioning chamber  Main unit outer case  Humidity chamber  Display (Excluding LCD panel)  Heater  Skin temperature probe  Sensor module  Inner panel  LCD panel  Mattress platform for weight monitor  Tray for weight monitor  Fan cover  Boiler (Humidity chamber)  Warmner area  Reflecting board  Sodium hypochlorite            X    X  X    X  X  X            X    X  Ethanol  X    X  X  X    X  X    X    (*1)  X  X  X  X  X  X    X    Isopropanol  X    X  X  X    X  X    X    (*1)  X  X  X  X  X  X    X    Ethanol, isopropanol  X    X  X  X    X  X    X    (*1)  X  X  X  X  X  X    X    Isopropanol, eucalyptus oil  X    X  X  X    X  X    X    (*1)  X  X  X  X  X  X    X    Benzalkonium chloride (ethanol solution)  X    X  X  X    X  X    X    (*1)  X  X  X  X  X  X    X    Chlorhexidine gluconate  X    X  X  X    X  X    X    (*1)  X  X  X  X  X  X    X    Hydrogen Peroxide 0.1 -1.5%                                            Hydrogen peroxide 7%            X    X  X    X  X  X            X    X  Benzalkonium chloride (water solution)                                            Benzalkonium chloride                                            Chlorhexidine gluconate (ethanol solution)                                            Alkyldiaminoethylglycine hydrochloride                                            Parts  Class  Method  Guideline of recommended chemicals for cleaning and disinfection for i series incubators Parts to be wiped for cleaning  Middle level Low level  Chemical disinfection  Disinfectant  (*1) Skin temperature probe can be cleaned by ethanol disinfection but the surface of cable may be hardened by deterioration due to repeated cleaning.  Snap-open access port packing  Admittance panel packing  Boiler cap  Cartridge tank  Tank cap  Fan  Baby guard  Tube introduction slit packing  Oxygen sensor cap  X-ray cassette tray door packing  Canopy packing  Patiend circuit slot grommet  Sodium hypochlorite          X  X              Hydrogen Peroxide 0.1 -1.5%                          Hydrogen peroxide 7%            X              Benzalkonium chloride (water solution)                          Benzalkonium chloride                          Chlorhexidine gluconate (ethanol solution)                          Alkyldiaminoethylglycine hydrochloride                          Parts  Class  Method  Parts to be immersed for cleaning  Low level  Middle level  Chemical disinfection  Disinfectant  [ Remarks ] 1 The effect of disinfectant may vary depending on target bacteria. Follow the instruction of disinfectant to be used. 2 Some disinfectants may include alcohol that is prohibited for use on ATOM's infant warmer. Make sure to check the ingredients in the disinfectant to be used before use. 3 Refer to product's operation manual for more information about disinfection method. 4 This list is the result of study based on general information related to disinfectants and it includes some information that is not a verification result that the disinfectant is actually used. Before using your disinfectant, try to use it at obscure place of the product and check that there is no change of color and deterioration. 5 Please note that information in this document is subject to change without notice depending on market information.
File Type: PDF
File Size: 73.3 KB
File Name: Guideline of recommended chemicals for cleaning and disinfection (Infant Incubator) updated_20161103.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions