Boston Scientific

MicroPace Cardiac Stimulators

ORLAB Quick Installation Guide Rev 3.0

Quick Installation Guide

2 Pages

Connecting the Pre-Wired ORLab Cart  D1-D2 Audio  Quick Installation Guide  D1  A1 - A2 Monitor Signals  C1-C5 Power  E1-E2 Stimulus  A1  C1  See overleaf 5  E1 WARNING Not Suitable for direct connection to RF Ablation Power > 150W into 300 Ohms  X  CHAN 1 (ATRIUM)  CHAN 2  (VENTRICLE)  D2 VGA  LAN2  LAN1  eo C2 WARNING Not Suitable for direct connection to RF Ablation Power > 150W into 300 Ohms  VGA COM2  DC12V/IN  COM1 CHAN 1  CHAN 2  (ATRIUM)  LAN2 COM4  (VENTRICLE)  LAN1  KB  DC12V/IN  B1-B3 Signals  A2  B1  VGA COM2  COM1 LAN2  COM4  LAN1  C3  KB  Distributed by AtriCure, Inc.  B2  7555 Innovation Way Mason, OH 45040 USA  Manufactured by  C4 PACE OUTPUT, EACH CHANNEL 0.5 - 1- ms pulses 0-25 mA into 200 - 1000 Ohm, 0-31V  Micropace Pty Ltd. 41 / 159 Arthur Street, E2  PACE OUTPUT, EACH CHANNEL 0.5 - 1- ms pulses 0-25 mA into 200 - 1000 Ohm, 0-31V  EMERGENCY FIXED PACE OUTPUT 2 ms pulses @ 100 ppm, Ventrical Ch2 only 5 mA into 200-1000 Ohm, 0-5 V  B3  POWER ON/OFF  POWER INPUT Internally Fused  Homebush West  COMPUTER LINK PORT PACE OUTPUT Ch1 (Atrium)  Check Lead  NSW 2140  Pace V Ch2  Sydney, Australia  Battery  POWER INPUT Internally Fused PACE OUTPUT, EACH CHANNEL 0.5 - 1- ms pulses 0-25 mA into 200 - 1000 Ohm, 0-31V  EMERGENCY FIXED PACE OUTPUT 2 ms pulses @ 100 ppm, Ventrical Ch2 only 5 mA into 200-1000 Ohm, 0-5 V  CARDIAC STIMULATOR Model No EPS320 Part No: MP3008 Part: Stimulus Generator Unit (SGU)  COMPUTER LINK PORT  AUXILIARY PORT  !  Ch2 (Ventric)  POWER INPUT Internally Fused  COMPUTER LINK PORT  AUXILIARY PORT  !  ECG-1 INPUT 1  ECG-2 INPUT  SYNC-1 INPUT  Patient  EPS 320 CARDIAC STIMULATOR  BACKUP MANUAL PACE CONTROL  POWER  600ms  5.0mA  Mains Power Battery Power  Backup / Standby  88 88  PACE OUTPUT Ch1 (Atrium)  Check Lead  Ch2 (Ventric)  Check Lead  Pace V Ch2  Pace Interval (ms)  Battery  ms  Battery Low  PC Pace Control  Serial No (SN)  Pace On / Off  861  2  Patient  Plug in to pace Ventricle Ch2 100 ppm @ 5mA  Manufacturer Micropace Pty Ltd 7/186-188 Canterbury Rd Canterbury NSW 2193 AUSTRALIA www.micropaceEP.com  8 88  Patient  Patient Plug in to pace Ventricle Ch2 100 ppm @ 5mA  Current (mA)  600ms  5.0mA  mA  14.5-16VDC 0.75A  EPS 320 CARDIAC STIMULATOR  230V  I  230V  0  OUTPUT: 115V SWITCH 230v SWITCH SET ONLY WITH POWER OFF  115V FUSE = 10 AT 230V FUSE = 5 AT POWERCORD, SEE MANUAL MAX OUTPUT: 115V = 8.34A (1000VA), 230V = 4.17A (1000VA) OUTPUT FLOATING, NEUTRAL CONDUCTOR NOT GROUNDED  C5 230V  I  230V  0  POWER ON/OFF  Check Lead  14.5-16VDC 0.75A  OUTPUT: 115V SWITCH 230v SWITCH SET ONLY WITH POWER OFF 115V FUSE = 10 AT 230V FUSE = 5 AT POWERCORD, SEE MANUAL MAX OUTPUT: 115V = 8.34A (1000VA), 230V = 4.17A (1000VA) OUTPUT FLOATING, NEUTRAL CONDUCTOR NOT GROUNDED  See overleaf 1  2797
File Type: PDF
File Size: 1.99 MB
File Name: 4.-R_ORLab-QuickStart-A3-Folded-Sheet_Rev3.0.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions