BOWA-electronic

BOWA ARC 250 and 303 Safety Inspection Report Ver 2.2

Safety Inspection Report

2 Pages

Safety Inspection Report for BOWA HF-Surgery unit ARC 250/303 up to version 2.2 Hospital:  Data:  Department:  Contact person:  Serial No.:  Article-No.:  Device type (IEC): CF  Remarks  Protect. class (IEC): I  Failed  Software version:  Passed  Device type  Visual inspection  Remarks  Failed  Passed  Device and accessories without recognizable damage All inscriptions, CE marks and rating label legible Mains fuses correspond to the specified value Potential equalization and -Connection present and functional Operating manual present  Function check All displays and indicator lights Activation of monopolar Cut / Coag output 1 with finger switch * Activation of monopolar Cut / Coag output 2 with finger switch Activation of monopolar Cut / Coag output 2 with foot switch Activation of Bipolar / Coag output 3 Activation of monopolar SimCoag with finger switch at output 1 & 2 * No simultaneous activation of foot switch and finger switch possible  Remarks  Failed  Passed  Touch monitor - AUTOSTART function (reference value 0,8 – 1,2 kΩ) ARC PLUS communication interface  EASY neutral electrode monitoring  Remarks  Failed  Neutral electrode, standby two-part green Neutral electrode, NE flashing yellow NE-monitoring, NE yellow flashing at +50% deviation from measured value (R = 50 Ohm, → reference value 75 Ohm) Neutral electrode, NE off (red) Passed  Measured value [Ω]  Reference value [Ω]  Description  8 ... 15 Ω 120 ... 160 Ω 75 Ω ± 20% 180 ... 220 Ω  Measurement of the HF output power for cutting / coagulation Reference Program [No.] / name RL value [W] [ 0 ] Standard - Cut  Blend 9 RL = 500 Ω  Measured value [W]]  ARC 250  250 W ± 20 % ARC 303  [ 0 ] Standard - Forced / Mixed COAG Mode [ 0 ] Standard - Forced / Cutting Mode [ 0 ] Standard - Forced / Non Cutting Mode [ 0 ] Standard - Spray [ 0 ] Standard - Moderate [ 5 ] Argon Flex (optional) [ 1 ] Macro - Bipolar [ 0 ] Standard - Bipolar  RL = 500 Ω RL = 500 Ω RL = 500 Ω RL = 500 Ω RL = 75 Ω RL = 500 Ω RL = 75 Ω RL = 75 Ω  300 W ± 20 % 120 W ± 20 % 75 W ± 20 % 120 W ± 20 % 120 W ± 20 % 120 W ± 20 % 120 W ± 20 % 75 W ± 20 % 120 W ± 20 %  = coagulation = cut  * Must be tested only at ARC 303!  BOWA-electronic GmbH & Co. KG Heinrich-Hertz-Strasse 4-10, D-72810 Gomaringen  page 1 of 2  This test report refers to service manual 900-301_SM_V2.2_10715-S2-20111024-EN
File Type: PDF
File Size: 167 KB
File Name: BOWA-electronic - BOWA ARC 250 and 303 Safety Inspection Report Ver 2.2.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions