BOWA ARC 300 and 350 Safety Inspection Report Ver 2.6 June 2010

Safety Inspection Report

2 Pages

Safety Inspection Report for BOWA HF-Surgery unit ARC 300 / 350 Hospital:  Data:  Department:  Contact person:  Device type:  Remarks  Failed  Passed  Serial No.:  Software version:  Protect. class (IEC): I  Article-No.:  Device type (IEC): CF  Visual inspection Device and accessories without recognizable damage All inscriptions, CE marks and rating label legible Mains fuses correspond to the specified value Potential equalization and -Connection present and functional Operating manual present  Function check  Remarks Remarks  Failed Failed  Passed  Passed  All displays and indicator lights Activation of Monopolar Cut / Coag output 1 with finger switch Activation of Monopolar Cut / Coag output 2 with finger switch Activation of Monopolar Cut / Coag output 2 with foot switch Activation of Bipolar Cut1) / Coag output 3 Activation of Bipolar Cut1) / Coag output 4 No simultaneous activation of foot switch and finger switch possible Touch monitor - autostart function (reference value 1000 – 1800 Ω) ARC PLUS communication interface (optional)  EASY neutral electrode monitoring Description  Reference value [Ω]  Neutral electrode, standby two-part green Neutral electrode, NE flashing Neutral electrode, NE off (red)  8 ... 15 Ω 130 ... 170 Ω 170 ... 250 Ω  Measurement of the HF output power for cutting / coagulation Reference Program [No.] / name RL value [W] [ 0 ] Standard - Cut Blend 9 [ 0 ] Standard - Forced / Mixed COAG Mode [ 0 ] Standard - Spray [ 0 ] Standard - Moderate [ 0 ] Standard - Moderate/Desiccate Mode 1*) [ 0 ] Standard - Forced / Cutting Mode [ 0 ] Standard - Moderate / Desiccate Mode 4 [ 0 ] Standard - Forced - Non Cutting Mode [ 8 ] Local Anesthesia - Forced [12] DryCut Blend 9 **) [18] Bipolar TUR - Bipolar Cut Eff. 9 [18] Bipolar TUR - Bipolar Coag **) Eff. 9 [ 7 ] Micro Plastic - Bipolar [ 0 ] Standard - Bipolar [ 0 ] Standard - Bipolar Cut **) Blend 9  RL = 500 Ω RL = 500 Ω RL = 500 Ω RL = 75 Ω RL = 500 Ω RL = 500 Ω RL = 500 Ω RL = 500 Ω RL = 500 Ω RL = 500 Ω RL = 500 Ω RL = 75 Ω RL = 75 Ω RL = 75 Ω RL = 500 Ω  Measured value [Ω]  Measured value [W]]  300 W ± 20 % 120 W ± 20 % 120 W ± 20 % 120 W ± 20 % 120 W ± 20 % 120 W ± 20 % 120 W ± 20 % 120 W ± 20 % 40 W ± 20 % 200 W ± 20 % 380 W +5 / -20 % 170 W ± 20 % 50 W ± 20 % 120 W ± 20 % 150 W ± 20 %  = coagulation = cut *) = During this measurement it is necessary to produce a spark before the measured value can be read. This means that during the activation the test lead must be plugged out and in at the output socket. **) = only ARC 350  BOWA-electronic GmbH & Co. KG Heinrich-Hertz-Strasse 4-10, D-72810 Gomaringen  page 1 of 2  This inspection protocol referring to service manual 900-350_SM_V2.6_10590-S7-20100620-EN
File Type: PDF
File Size: 172 KB
File Name: BOWA-electronic - 900-350 - BOWA ARC 300 and 350 Safety Inspection Report Ver 2.6 June 2010 - 2010-06.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions