care of sweden
Pressure Care Mattresses
CuroCell Area Self adjusting pressure care mattress User manual Jan 2009
User Manual
12 Pages
Preview
Page 1
takes the pressure off
User manual 2009/01
CuroCell AREA Self adjusting pressure care mattress This user manual is valid for the following products: CC-3601, CC-3603, CC-3605.
Article number user manual: 95-001064
Table of contents 1 Introduction
4
2 Product description and performance
5
3 Unpacking the mattress
6
4 Care instructions
7
5 Miscellaneous
8
6 Accessories
2
9
IMPORTANT Read all instructions before using the mattress
WARNING!
1. The hygiene cover is liquid resistant and vapour permeable. Therefore, always make sure to place the patient correctly to avoid the risk of suffocation. 2. Always make sure that the mattress has the right size. 3. The mattress is protected by a hygiene cover, avoid to use other covers in combination with the mattress. 4. If the bed has bed rails, it is recommended that these are up and locked in position. 5. In contact with fire sources and warm surfaces, such as open fire, a burning ciggarett or a varm lamp, the product can be damaged and the function can be impaired.
SYMBOLS
Read the user manual
Guarantee time
Fire retardant
Not in domestic refuse. Follow instructions for recycling.
Min-max user weight
Directly on bed base
Not on top of other mattress
Not to be rotated
Not to be turned
3
1 Introduction Use this manual when the mattress is being unpacked and when to use it for the first time, as well as for future reference.
1.1 General information This product is a medical product according to MDD 92/43/EEC. It also fulfils the applicable standards according to the medical directives.
1.2 Intended use The CuroCell AREA is a replacement mattress used in all types of health care environments and sits directly onto the bed base. It is used preventively and as an aid in treatment of pressure ulcers. The mattress is intended for user weights of 30-230 kg. The mattress is to be cleaned between different users.
NOTE! - When used together with positioning pillows, read the user manual for the pillows carefully, in order to place the user correctly. - It is not recommended to use this product together with evacuation sheets. - Be careful when using bed rails or other protections on the bed, so the mattress does not get damaged. - The mattress must not be lifted with a user on the mattress.
4
2 Product description and performance The CuroCell AREA is available in the following sizes: In the width 80 cm, 85 cm, 90 cm and the length 200 cm. Because of its unique construction combining foam and air, this mattress provides high user comfort, as well as a solution for pressure care without the need for external pumps or electricity. The system uses patient weight and movements to distribute the internal air reservoir amongst the cells, in order to always maintain low surface pressure. The CuroCell AREA is delivered with a liquid resistant and vapour permeable hygienic cover. The CuroCell AREA is produced from modern, recyclable materials that fulfil the health care requirements for hygiene, quality and safety. CuroCell AREA Type: Alternating pressure mattress Height: 18 cm Function: For prevention and treatment of pressure ulcers. User weight: 30-230 kg Guarantee: 3 years
2.1 Mattress drawing 1
2
3
1. Tubes 2. 9 air cells 3. Foam core
For more information on all our products: Contact us on phone: +46 325 189 60 or e-mail: [email protected] You can also download all our product sheets from: www.careofsweden.se
5
3 Unpacking the mattress Our mattresses are packed in recyclable plastic. 1. Start with making sure that the package is not damaged. Remove the plastic bag and any protective material. Avoid using a knife when opening the package, since this could damage the hygiene cover. 2. Correct the cover. 3. After a few minutes, the product is ready to use.
6
4 Care instructions It is important to follow the below instructions before the product is used for a new user. When unsure, contact the hygiene responsible or contact the supplier for help and further instructions.
IMPORTANT !
Check the hygiene cover every time it is being cleaned. If the cover is damaged, it is to be replaced or repaired. Follow the local instructions and the cleaning agents’ instructions carefully.
4.1 Covers Wipe off the hygiene cover with a mild cleaning agent and water, or disinfect with alcohol-based cleaning agent. Excrement and blood spots are to be removed immediately with cold water. Follow the local instructions and the cleaning agents’ instructions carefully. Chloride and phenolic based products should be avoided for cleaning, since they can effect the cover surface in a negative way. If chloride still is used, we recommend to dilute it to maximum 1%. The cover can be machine washed in max. 95°C, tumble or hanged dry. Divisible covers should be divided before wash. The black bottom part should be washed separately the first time. The inner cover can be machine washed in max. 60°C and tumbled dry.
4.2 Mattress core The hygine cover protects the foam core completely, which means cleaning of the core seldom is necessary. If, for any reason, the core needs to be cleaned, clean the effected area with a mild cleaning agent and water (for example spray on). Press out the water carefully. Let the mattress dry in a warm, ventilated area, without direct exposure of sunlight. The core needs to be completely dry before it is used again. When needed, use an alcohol-based cleaning agent to disinfect.
4.3 Air cells 1. Remove the hygiene cover, as well as the inner cover. 2. Carefully remove the air cells from the foam core. Remove the cell holder from the cells. 3. Place the air cells and the tubes in a clean and suitable cleaning area. 4. Wipe of the cells and the tubes with a mild cleaning agent or disinfect with an alcohol-based agent. Let it dry. 5. Replace the cells into the cell holder. Place the air cells back into the foam core. Check that all the tubes and connectors are secure and tight, before closing the cover. 6. Wipe off and disinfect all the work surfaces with an alcohol-based cleaning agent.
7
5 Miscellaneous 5.1 Storage Store the mattress on a flat surface or carefully rolled/folded with the zipper closed. Always store at room temperature in a dry area. Make sure the mattress is stored where it will not be exposed to thrusts, hits or other things that can damage it. Avoid direct exposure of sunlight. If the mattress is to be stored more than 3 months, we recommend it is stored on a flat surface (not folded or rolled up).
5.2 Labelling The mattresses are labelled with production date, article number, size, care and wash instructions, EAN-bar code, as well as space for own labelling.
5.3 Guarantee This CuroCell mattress has a 3 year guarantee, The guarantee is valid for production errors. The guarantee is not valid for normal wear or deterioration of the product or damages that occur because of careless handling or care of the product.
5.4 Service and maintenance The mattress needs no other service or maintenance than cleaning as described in this user manual.
5.5 Repairs For instructions, contact the supplier.
5.6 Recycling All bed products are fully recyclable and should be recycled as “combustible waste”. No dismantling needed.
8
5.7 Returns and complaints Complaints are to be reported to the supplier. Return of a product shall follow the supplier’s instructions and can only be done after the complaint has been reported. Damages due to the transportation should be reported to the transportation agent.
6 Accessories For accessories, please contact the supplier.
6.1 Other accessories Prima 6 Distance mattress for placement underneath an overlay mattress, such as a CuroCell Nova (airmattress) or an Optimal 5zon BM (preventative mattress). Optimal Extension part The extension part is an accessory used to fill out the space that a short mattress leaves in a long bed. The extension part is available in many different sizes, depending on widht and height of the mattress. Optimal Hygiene pillow The hygiene pillow is developed for caring environments, is comfortable and very easy to clean. Delivered with a removable hygiene cover. The pillow is available in the following sizes: 35x45, 50x60 och 50x70 cm. Optimal Sens An anatomically shaped pillow, that gives maximum neck supprt. Produced in visco-elastic foam and delivered with a removable hygiene cover. Curera Support Wedge An aid for positioning and position changes. The support wedge is easy to use and has a removable liquid resistant hygiene cover. Curera positioning pillows Curera positionering is a range of pillows used for positioning, relief and support in all kinds of care facilities. When bedbound individuals don’t move enough, it increases the risk of pressure ulcers. With regular position changes, this risk can be reduced and the comfort level increased. When other accessories are needed, or for more information about our products, please contact the supplier, or visit our website: www.careofsweden.se.
9
Notes _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________
10
Notes _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________
11
Manufactured by
Mailing address: Care of Sweden AB Box 158 SE-512 24 Svenljunga
Contact: Phone: Fax: E-mail: WWW:
+46 325-189 60 +46 325-128 40 [email protected] www.careofsweden.se
Visiting/freight address: Boråsvägen 14 512 53 Svenljunga
Urgent: Phone:
+46 325-101 11
Supplied by