CASELLA

Sound Level Meters

CEL-6X0 Series Field Guide Aug 2008

Field Guide

2 Pages

FIT THE BATTERIES The CEL-6X0 Instrument requires three AA batteries. Remove the battery compartment cover and fit the batteries observing correct polarity. Refit the battery cover. Note: The batteries can be zinc carbon, alkaline or rechargeable. Do not mix battery types. SWITCH ON Press the ON/OFF Key - Figure 1 (3). Check the battery condition symbol shows good charge. CEL- 620A - The initialisation screen will be displayed, then the Graph screen in the STOP mode (red bar at the top and bottom of screen). Press the MENU Key to access settings, memory and instrument status. CEL- 620B - The initialisation screen will be displayed, then the Octave screen in the STOP mode (red bar at the top and bottom of screen). Press VIEW to see the Graph screen. Press the MENU Key to access settings, memory and instrument status.  SET TIME AND DATE (Refer to Figure 3) Select (1) Settings. Press (B) to continue. Use cursor keys (C) to select Set Clock symbol (2). Press (B) to continue. Press Edit (B) and use cursor keys (C) to set the time. Press SAVE (B). Use cursor keys (C) to enable the date. Press (B) to edit. Repeat to alter the date as required. Press EXIT (A) when finished.  Figure 4 Calibration Screens Figure 6 Run Duration  SETTINGS SCREEN (Refer to Figure 2) SETUP (Refer to Figure 5) On the SETTINGS screen, select (1) and press (B) to continue. Use cursor keys (C) to select 6X0 SETUP (2). Press (B) to continue. Use cursor keys (C) to select the required measurement view for your local legislation. Refer to Operator’s Manual for details on changing ‘User View’.  1 – SETTINGS OPTIONS / 2 – RESULTS MEMORY / 3 – INSTRUMENT STATUS / A – BACK TO PREVIOUS SCREEN / B – MOVE TO NEXT SCREEN / C NAVIGATION CURSORS Figure 2 Settings Screen  SET LANGUAGE (Refer to Figure 2) Select (1) Settings. Press (B) to continue. Use cursor keys (C) to select Language symbol (4). Press (B) to continue. Use cursor keys (C) to select Language. Press SELECT (B). Press EXIT (A).  Use cursor key (C) to enable DURATION and press Edit (B) to continue. Use cursor keys (C) to set the Duration time. Press SAVE (B).  Figure 8 Cal. Ref. Level MEMORY RESULTS (Refer to Figure 9 and 10) From MENU screen, use cursor keys (C) to select MEMORY RESULTS (1) and press (B) to continue. Use cursor keys (C) to select a Memory Result. Press (B) to select measurement. Use cursor keys (C) to select VIEW (See Figure 10 over page). Press SELECT (B) to continue. The selected Memory Results are displayed. For additional data press VIEW (B).  Figure 7 Run Duration Figure 3 Set Time and date CALIBRATE (Refer to Figure 4) Fit the acoustic calibrator over the removable microphone and push it home. Press the acoustic calibrator ON/OFF Key (1). The Instrument detects the signal and activates the calibration screen (yellow bar). Press (B). The Instrument will be calibrated and the word PASSED displayed. Remove the acoustic calibrator. Press EXIT (A) to go back to the Stop screen. Press and hold the acoustic calibrator ON/OFF Key to switch the calibrator off.  Figure 5 Settings Options BACKLIGHT Refer to the Operator’s Manual for details. RUN DURATION (Refer to Figure 6 and 7) Use this feature if you require measurement runs of a set time duration. From the SETTINGS screen use cursor keys (C) to select RUN DURATION (1). Press (B) to continue. To edit ACTIVATION press EDIT (B). Use cursor keys (C) to make changes. Press SAVE (B) to continue.  CAL. REF. LEVEL (Refer to Figure 8) Note this setting should only be accessed if using an acoustic calibrator whose output level is not exactly 114.0dB. From the SETTINGS screen (see Figure 2), use cursor keys (C) to select CAL.REF. LEVEL. Press (B) to continue. The dB Level will be highlighted. Press EDIT (B). Use the cursor Keys (C) to edit the dB Level. Press SAVE (B) to go back to the Ref. Cal. Level screen. Press EXIT (A) to go back to Settings menu.  Figure 9 Memory Results This screen displays detailed specific data for the saved Memory Results (Figure 10). This is read only data. To view this data in a graphical format, press View (B). The Octave values saved in the Memory Results are displayed in a graphical format. Use cursor keys (C) to move the vertical line across the graph. Each graph bar represents an octave level measured in Hz or KHz. Press View (B) again to view tabular octave results.
File Type: PDF
File Size: 724 KB
File Name: Casella_CEL-600 Series Field Guide (English).pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions