Basic Service Manual
618 Pages
Preview
Page 1
P R E L I M I N A R Y
(MAY 26, 2020) VE6_VE8_COVER FOR
GE Healthcare
LOGIQ P9/P7 Service Manual
BASIC SERVICE DOCUMENTATION. COPYRIGHT GENERAL ELECTRIC COMPANY. ADVANCED SERVICE DOCUMENTATION. COPYRIGHT GENERAL ELECTRIC COMPANY. GE CONFIDENTIAL. UNLICENSED USE BY NON-GE PARTIES IS STRICTLY PROHIBITED. PROPRIETARY TO GE. GE RESTRICTED. DISCLOSURE TO NON-GE PARTIES PROHIBITED. © 2020 General Electric Company. All Rights Reserved.
Document Number: 5604324 Revision: 13
GE DIRECTION 5604324, REVISION 13
LOGIQ P9/P7 SERVICE MANUAL
Important Precautions TRANSLATION POLICY
WARNING
THIS SERVICE MANUAL IS AVAILABLE IN ENGLISH ONLY. • IF A CUSTOMER’S SERVICE PROVIDER REQUIRES A LANGUAGE OTHER THAN ENGLISH, IT IS THE CUSTOMER’S RESPONSIBILITY TO PROVIDE TRANSLATION SERVICES. • DO NOT ATTEMPT TO SERVICE THE EQUIPMENT UNLESS THIS SERVICE MANUAL HAS BEEN CONSULTED AND IS UNDERSTOOD. • FAILURE TO HEED THIS WARNING MAY RESULT IN INJURY TO THE SERVICE PROVIDER, OPERATOR OR PATIENT FROM ELECTRIC SHOCK, MECHANICAL OR OTHER HAZARDS.
AVERTISSEMENT
CE MANUEL DE MAINTENANCE N’EST DISPONIBLE QU’EN ANGLAIS. • SI LE TECHNICIEN DU CLIENT A BESOIN DE CE MANUEL DANS UNE AUTRE LANGUE QUE L’ANGLAIS, C’EST AU CLIENT QU’IL INCOMBE DE LE FAIRE TRADUIRE. • NE PAS TENTER D’INTERVENTION SUR LES ÉQUIPEMENTS TANT QUE LE MANUEL SERVICE N’A PAS ÉTÉ CONSULTÉ ET COMPRIS. • LE NON-RESPECT DE CET AVERTISSEMENT PEUT ENTRAÎNER CHEZ LE TECHNICIEN, L’OPÉRATEUR OU LE PATIENT DES BLESSURES DUES À DES DANGERS ÉLECTRIQUES, MÉCANIQUES OU AUTRES.
WARNUNG (DE)
DIESES KUNDENDIENST-HANDBUCH EXISTIERT NUR IN ENGLISCHER SPRACHE. • FALLS EIN FREMDER KUNDENDIENST EINE ANDERE SPRACHE BENÖTIGT, IST ES AUFGABE DES KUNDEN FÜR EINE ENTSPRECHENDE ÜBERSETZUNG ZU SORGEN. • VERSUCHEN SIE NICHT, DAS GERÄT ZU REPARIEREN, BEVOR DIESES KUNDENDIENST-HANDBUCH NICHT ZU RATE GEZOGEN UND VERSTANDEN WURDE. • WIRD DIESE WARNUNG NICHT BEACHTET, SO KANN ES ZU VERLETZUNGEN DES KUNDENDIENSTTECHNIKERS, DES BEDIENERS ODER DES PATIENTEN DURCH ELEKTRISCHE SCHLÄGE, MECHANISCHE ODER SONSTIGE GEFAHREN KOMMEN.
(EN)
(FR)
-
i
GE DIRECTION 5604324, REVISION 13
HOIATUS (ET)
LOGIQ P9/P7 SERVICE MANUAL
KÄESOLEV TEENINDUSJUHEND ON SAADAVAL AINULT INGLISE KEELES. • KUI KLIENDITEENINDUSE OSUTAJA NÕUAB JUHENDIT INGLISE KEELEST ERINEVAS KEELES, VASTUTAB KLIENT TÕLKETEENUSE OSUTAMISE EEST. • ÄRGE ÜRITAGE SEADMEID TEENINDADA ENNE EELNEVALT KÄESOLEVA TEENINDUSJUHENDIGA TUTVUMIST JA SELLEST ARU SAAMIST. • KÄESOLEVA HOIATUSE EIRAMINE VÕIB PÕHJUSTADA TEENUSEOSUTAJA, OPERAATORI VÕI PATSIENDI VIGASTAMIST ELEKTRILÖÖGI, MEHAANILISE VÕI MUU OHU TAGAJÄRJEL.
(FI)
TÄMÄ HUOLTO-OHJE ON SAATAVILLA VAIN ENGLANNIKSI. • JOS ASIAKKAAN PALVELUNTARJOAJA VAATII MUUTA KUIN ENGLANNINKIELISTÄ MATERIAALIA, TARVITTAVAN KÄÄNNÖKSEN HANKKIMINEN ON ASIAKKAAN VASTUULLA. • ÄLÄ YRITÄ KORJATA LAITTEISTOA ENNEN KUIN OLET VARMASTI LUKENUT JA YMMÄRTÄNYT TÄMÄN HUOLTO-OHJEEN. • MIKÄLI TÄTÄ VAROITUSTA EI NOUDATETA, SEURAUKSENA VOI OLLA PALVELUNTARJOAJAN, LAITTEISTON KÄYTTÄJÄN TAI POTILAAN VAHINGOITTUMINEN SÄHKÖISKUN, MEKAANISEN VIAN TAI MUUN VAARATILANTEEN VUOKSI.
ΠΡΟΕΙΔΟΠΟΙΗΣΗ
ΤΟ ΠΑΡΟΝ ΕΓΧΕΙΡΙΔΙΟ ΣΕΡΒΙΣ ΔΙΑΤΙΘΕΤΑΙ ΣΤΑ ΑΓΓΛΙΚΑ ΜΟΝΟ. • ΕΑΝ ΤΟ ΑΤΟΜΟ ΠΑΡΟΧΗΣ ΣΕΡΒΙΣ ΕΝΟΣ ΠΕΛΑΤΗ ΑΠΑΙΤΕΙ ΤΟ ΠΑΡΟΝ ΕΓΧΕΙΡΙΔΙΟ ΣΕ ΓΛΩΣΣΑ ΕΚΤΟΣ ΤΩΝ ΑΓΓΛΙΚΩΝ, ΑΠΟΤΕΛΕΙ ΕΥΘΥΝΗ ΤΟΥ ΠΕΛΑΤΗ ΝΑ ΠΑΡΕΧΕΙ ΥΠΗΡΕΣΙΕΣ ΜΕΤΑΦΡΑΣΗΣ. • ΜΗΝ ΕΠΙΧΕΙΡΗΣΕΤΕ ΤΗΝ ΕΚΤΕΛΕΣΗ ΕΡΓΑΣΙΩΝ ΣΕΡΒΙΣ ΣΤΟΝ ΕΞΟΠΛΙΣΜΟ ΕΚΤΟΣ ΕΑΝ ΕΧΕΤΕ ΣΥΜΒΟΥΛΕΥΤΕΙ ΚΑΙ ΕΧΕΤΕ ΚΑΤΑΝΟΗΣΕΙ ΤΟ ΠΑΡΟΝ ΕΓΧΕΙΡΙΔΙΟ ΣΕΡΒΙΣ. • ΕΑΝ ΔΕ ΛΑΒΕΤΕ ΥΠΟΨΗ ΤΗΝ ΠΡΟΕΙΔΟΠΟΙΗΣΗ ΑΥΤΗ, ΕΝΔΕΧΕΤΑΙ ΝΑ ΠΡΟΚΛΗΘΕΙ ΤΡΑΥΜΑΤΙΣΜΟΣ ΣΤΟ ΑΤΟΜΟ ΠΑΡΟΧΗΣ ΣΕΡΒΙΣ, ΣΤΟ ΧΕΙΡΙΣΤΗ Ή ΣΤΟΝ ΑΣΘΕΝΗ ΑΠΟ ΗΛΕΚΤΡΟΠΛΗΞΙΑ, ΜΗΧΑΝΙΚΟΥΣ Ή ΑΛΛΟΥΣ ΚΙΝΔΥΝΟΥΣ.
VAROITUS
(EL)
FIGYELMEZTETÉS (HU)
EZEN KARBANTARTÁSI KÉZIKÖNYV KIZÁRÓLAG ANGOL NYELVEN ÉRHETŐ EL. • HA A VEVŐ SZOLGÁLTATÓJA ANGOLTÓL ELTÉRŐ NYELVRE TART IGÉNYT, AKKOR A VEVŐ FELELŐSSÉGE A FORDÍTÁS ELKÉSZÍTTETÉSE. • NE PRÓBÁLJA ELKEZDENI HASZNÁLNI A BERENDEZÉST, AMÍG A KARBANTARTÁSI KÉZIKÖNYVBEN LEÍRTAKAT NEM ÉRTELMEZTÉK. • EZEN FIGYELMEZTETÉS FIGYELMEN KÍVÜL HAGYÁSA A SZOLGÁLTATÓ, MŰKÖDTETŐ VAGY A BETEG ÁRAMÜTÉS, MECHANIKAI VAGY EGYÉB VESZÉLYHELYZET MIATTI SÉRÜLÉSÉT EREDMÉNYEZHETI.
-
iii
GE DIRECTION 5604324, REVISION 13
LOGIQ P9/P7 SERVICE MANUAL
BRĪDINĀJUMS (LV)
ŠĪ APKALPES ROKASGRĀMATA IR PIEEJAMA TIKAI ANGĻU VALODĀ. • JA KLIENTA APKALPES SNIEDZĒJAM NEPIECIEŠAMA INFORMĀCIJA CITĀ VALODĀ, NEVIS ANGĻU, KLIENTA PIENĀKUMS IR NODROŠINĀT TULKOŠANU. • NEVEICIET APRĪKOJUMA APKALPI BEZ APKALPES ROKASGRĀMATAS IZLASĪŠANAS UN SAPRAŠANAS. • ŠĪ BRĪDINĀJUMA NEIEVĒROŠANA VAR RADĪT ELEKTRISKĀS STRĀVAS TRIECIENA, MEHĀNISKU VAI CITU RISKU IZRAISĪTU TRAUMU APKALPES SNIEDZĒJAM, OPERATORAM VAI PACIENTAM.
ĮSPĖJIMAS (LT)
ŠIS EKSPLOATAVIMO VADOVAS YRA IŠLEISTAS TIK ANGLŲ KALBA. • JEI KLIENTO PASLAUGŲ TEIKĖJUI REIKIA VADOVO KITA KALBA – NE ANGLŲ, VERTIMU PASIRŪPINTI TURI KLIENTAS. • NEMĖGINKITE ATLIKTI ĮRANGOS TECHNINĖS PRIEŽIŪROS DARBŲ, NEBENT VADOVAUTUMĖTĖS ŠIUO EKSPLOATAVIMO VADOVU IR JĮ SUPRASTUMĖTE • NEPAISANT ŠIO PERSPĖJIMO, PASLAUGŲ TEIKĖJAS, OPERATORIUS AR PACIENTAS GALI BŪTI SUŽEISTAS DĖL ELEKTROS SMŪGIO, MECHANINIŲ AR KITŲ PAVOJŲ.
ADVARSEL (NO)
DENNE SERVICEHÅNDBOKEN FINNES BARE PÅ ENGELSK. • HVIS KUNDENS SERVICELEVERANDØR TRENGER ET ANNET SPRÅK, ER DET KUNDENS ANSVAR Å SØRGE FOR OVERSETTELSE. • IKKE FORSØK Å REPARERE UTSTYRET UTEN AT DENNE SERVICEHÅNDBOKEN ER LEST OG FORSTÅTT. • MANGLENDE HENSYN TIL DENNE ADVARSELEN KAN FØRE TIL AT SERVICELEVERANDØREN, OPERATØREN ELLER PASIENTEN SKADES PÅ GRUNN AV ELEKTRISK STØT, MEKANISKE ELLER ANDRE FARER.
OSTRZEŻENIE (PL)
NINIEJSZY PODRĘCZNIK SERWISOWY DOSTĘPNY JEST JEDYNIE W JĘZYKU ANGIELSKIM. • JEŚLI FIRMA ŚWIADCZĄCA KLIENTOWI USŁUGI SERWISOWE WYMAGA UDOSTĘPNIENIA PODRĘCZNIKA W JĘZYKU INNYM NIŻ ANGIELSKI, OBOWIĄZEK ZAPEWNIENIA STOSOWNEGO TŁUMACZENIA SPOCZYWA NA KLIENCIE. • NIE PRÓBOWAĆ SERWISOWAĆ NINIEJSZEGO SPRZĘTU BEZ UPRZEDNIEGO ZAPOZNANIA SIĘ Z PODRĘCZNIKIEM SERWISOWYM. • NIEZASTOSOWANIE SIĘ DO TEGO OSTRZEŻENIA MOŻE GROZIĆ OBRAŻENIAMI CIAŁA SERWISANTA, OPERATORA LUB PACJENTA W WYNIKU PORAŻENIA PRĄDEM, URAZU MECHANICZNEGO LUB INNEGO RODZAJU ZAGROŻEŃ.
-
v
GE DIRECTION 5604324, REVISION 13
DİKKAT (TR)
LOGIQ P9/P7 SERVICE MANUAL
BU SERVİS KILAVUZU YALNIZCA İNGİLİZCE OLARAK SAĞLANMIŞTIR. • EĞER MÜŞTERİ TEKNİSYENİ KILAVUZUN İNGİLİZCE DIŞINDAKİ BİR DİLDE OLMASINI İSTERSE, KILAVUZU TERCÜME ETTİRMEK MÜŞTERİNİN SORUMLULUĞUNDADIR. • SERVİS KILAVUZUNU OKUYUP ANLAMADAN EKİPMANLARA MÜDAHALE ETMEYİNİZ. • BU UYARININ GÖZ ARDI EDİLMESİ, ELEKTRİK ÇARPMASI YA DA MEKANİK VEYA DİĞER TÜRDEN KAZALAR SONUCUNDA TEKNİSYENİN, OPERATÖRÜN YA DA HASTANIN YARALANMASINA YOL AÇABİLİR.
(JA)
Traditional Chinese
viii
-
GE DIRECTION 5604324, REVISION 13
LOGIQ P9/P7 SERVICE MANUAL
DAMAGE IN TRANSPORTATION All packages should be closely examined at time of delivery. If damage is apparent write “Damage In Shipment” on ALL copies of the freight or express bill BEFORE delivery is accepted or “signed for” by a GE representative or hospital receiving agent. Whether noted or concealed, damage MUST be reported to the carrier immediately upon discovery, or in any event, within 14 days after receipt, and the contents and containers held for inspection by the carrier. A transportation company will not pay a claim for damage if an inspection is not requested within this 14 day period.
CERTIFIED ELECTRICAL CONTRACTOR STATEMENT - FOR USA ONLY All electrical Installations that are preliminary to positioning of the equipment at the site prepared for the equipment shall be performed by licensed electrical contractors. Other connections between pieces of electrical equipment, calibrations and testing shall be performed by qualified GE Healthcare personnel. In performing all electrical work on these products, GE will use its own specially trained field engineers. All of GE’s electrical work on these products will comply with the requirements of the applicable electrical codes. The purchaser of GE equipment shall only utilize qualified personnel (i.e., GE’s field engineers, personnel of third-party service companies with equivalent training, or licensed electricians) to perform electrical servicing on the equipment.
OMISSIONS & ERRORS If there are any omissions, errors or suggestions for improving this documentation, please contact the GE Healthcare Global Documentation Group with specific information listing the system type, manual title, part number, revision number, page number and suggestion details. Mail the information to:Service Documentation, 9900 Innovation Drive (RP-2123), Wauwatosa, WI53226, USA. GE Healthcare employees should use TrackWise to report service documentation issues. These issues will then be in the internal problem reporting tool and communicated to the writer.
SERVICE SAFETY CONSIDERATIONS DANGER
DANGEROUS VOLTAGES, CAPABLE OF CAUSING DEATH, ARE PRESENT IN THIS EQUIPMENT. USE EXTREME CAUTION WHEN HANDLING, TESTING AND ADJUSTING.
WARNING WARNING Use all Personal Protection Equipment (PPE) such as gloves, safety shoes, safety
glasses, and kneeling pad, to reduce the risk of injury.
For a complete review of all safety requirements, see the Chapter 1, Safety Considerations section in the Service Manual.
x
-
GE DIRECTION 5604324, REVISION 13
LOGIQ P9/P7 SERVICE MANUAL
LEGAL NOTES The contents of this publication may not be copied or duplicated in any form, in whole or in part, without prior written permission of GE Healthcare. GE Healthcare may revise this publication from time to time without written notice.
TRADEMARKS All products and their name brands are trademarks of their respective holders.
COPYRIGHTS All Material Copyright© 2020 by General Electric Company Inc. All Rights Reserved.
-
xi
GE DIRECTION 5604324, REVISION 13
LOGIQ P9/P7 SERVICE MANUAL
Revision History Revision
Date
Reason for change
1
October 2014
Initial release
2
December 2014
Enhancement feedback
3
May 2015
Enhancement feedback
4
March 2016
Initial release for R2
5
August 2016
Correction
6
November 2016
Initial release for R2.5
7
July 2017
Enhancement feedback
8
June 2018
Enhancement feedback
9
August 2018
Enhancement feedback
10
October 2018
Enhancement feedback
11
January 2019
Enhancement feedback
12
January 2020
Enhancement feedback
13
May 2020
Enhancement feedback
List of Effected Pages (LOEP)
xii
Pages
Revision
Pages
Revision
Pages
Revision
Title Page
13
3-1 to 3-78
13
8-1 to 8-206
13
Warnings i to ii-xii
13
4-1 to 4-44
13
9-1 to 9-32
13
TOC
13
5-1 to 5-152
13
10-1 to 10-36
13
1-1 to 1-17
13
6-1 to 6-8
13
Back Cover
N/A
2-1 to 2-10
13
7-1 to 7-36
13
-
GE DIRECTION 5604324, REVISION 13
LOGIQ P9/P7 SERVICE MANUAL
Table of Contents CHAPTER 1 Introduction Overview... 1 - 1 Purpose of Chapter 1... 1 - 1 Purpose of Service Manual... 1 - 1 Typical Users of the Basic Service Manual... 1 - 2 Models Covered by this Manual... 1 - 2 Purpose of Operator Manual(s)... 1 - 3 Important Conventions... 1 - 3 Conventions Used in this Manual... 1 - 3 Standard Hazard Icons... 1 - 4 Product Icons... 1 - 5 Safety Considerations... 1 - 8 Introduction... 1 - 8 Human Safety... 1 - 8 Mechanical Safety ...1-8 Electrical Safety... 1 - 9 Safe Practices... 1 - 9 Probes... 1 - 9 Auxiliary Devices Safety... 1 - 10 Battery Safety... 1 - 12 Labels Locations... 1 - 13 Dangerous Procedure Warnings... 1 - 15 Lockout/Tagout Requirements (For USA Only)... 1 - 15 Returning/Shipping System, Probes and Repair Parts... 1 - 15 Electromagnetic Compatibility (EMC)... 1 - 16 What is EMC?... 1 - 16 Compliance... 1 - 16 Electrostatic Discharge (ESD) Prevention... 1 - 16 Customer Assistance... 1 - 17 Contact Information... 1 - 17 System Manufacturer... 1 - 17
xiii
Table of Contents
GE DIRECTION 5604324, REVISION 13
LOGIQ P9/P7 SERVICE MANUAL
CHAPTER 2 Site Preparation Overview... 2 - 1 Purpose of Chapter 2... 2 - 1 General Console Requirements... 2 - 2 Environmental Requirements... 2 - 2 Cooling... 2 - 2 Lighting... 2 - 2 Electrical Requirements... 2 - 2 LOGIQ P9/P7 Power Requirements... 2 - 3 Inrush Current... 2 - 3 Site Circuit Breaker... 2 - 3 Site Power Outlets... 2 - 3 Main Power Plug... 2 - 3 EMI Limitations... 2 - 4 Probe Environmental Requirements... 2 - 5 Time and Manpower Requirements... 2 - 5 System Specifications... 2 - 6 Physical Dimensions of LOGIQ P9/P7... 2 - 6 Acoustic Noise Output... 2 - 6 Electrical Specifications... 2 - 6 Facility Needs... 2 - 7 Purchaser Responsibilities... 2 - 7 Mandatory Site Requirements... 2 - 8 Site Recommendations... 2 - 8 Recommended Ultrasound Room Layout... 2 - 9 Networking Setup Requirements... 2 - 10 Stand-alone Unit (without Network Connection)... 2 - 10 Unit Connected to Hospital’s Network... 2 - 10 Purpose of the DICOM Network Function... 2 - 10 DICOM Option Pre-installation Requirements... 2 - 10
xiv
Table of Contents
GE DIRECTION 5604324, REVISION 13
LOGIQ P9/P7 SERVICE MANUAL
CHAPTER 3 Setup Instructions Overview... 3 - 1 The Purpose of Chapter 3... 3 - 1 Set Up Reminders... 3 - 2 Average Installation Time... 3 - 2 Installation Warnings... 3 - 3 Moving/Lifting the System... 3 - 3 System Acclimation Time... 3 - 3 OPIO Position... 3 - 3 Brake Pedal Operation... 3 - 4 Safety Reminders... 3 - 4 Receiving and Unpacking the Equipment... 3 - 5 Packing materials - recycling information... 3 - 8 Preparing for Set Up... 3 - 9 Verify Customer Order... 3 - 9 EMI Protection... 3 - 10 Connection of Auxiliary Devices... 3 - 11 Connecting the LCD Monitor... 3 - 12 Connecting the Black & White Printer... 3 - 13 Connection Scheme: B&W Printer... 3 - 14 Connecting the Secondary “Patient” LCD Monitor... 3 - 15 Connecting the Footswitch... 3 - 17 Connecting the USB Flash Memory Stick... 3 - 18 Connecting the external USB Hard disk (Handydrive)... 3 - 18 General Remarks and Hints when using external USB-Devices... 3 - 19 External USB-Devices - Connection... 3 - 19 External USB-Devices - Disconnection... 3 - 19 Completing the Set Up... 3 - 20 Connecting the Unit to a Power Source... 3 - 20 Power On / Boot Up... 3 - 21 Scanner Power On... 3 - 21 Back End Processor Boot Up... 3 - 22 During a normal boot, you may observe... 3 - 23 Power Off / Shutdown... 3 - 25 Scanner Shutdown... 3 - 27 Transducer Connection... 3 - 30 Table of Contents
xv
GE DIRECTION 5604324, REVISION 13
LOGIQ P9/P7 SERVICE MANUAL
Connecting the Probe... 3 - 30 Connecting the CW Pencil Probe... 3 - 31 Cable Handling... 3 - 31 Activating the Probe... 3 - 31 Deactivating the Probe... 3 - 31 Disconnecting the Probe... 3 - 31 Printer Installation... 3 - 32 Installing Digital Black & White Printer Sony UP-D898... 3 - 32 Digital Color Printer Sony UP-D25MD... 3 - 33 Installing the Bluetooth Deskjet Printer... 3 - 34 Connecting the Bluetooth Dongle into the System... 3 - 34 Verifying Bluetooth device driver... 3 - 35 Prepare the Printer and connect the Bluetooth Printer Adapter... 3 - 36 HP Officejet 100... 3 - 36 Bluetooth Pairing... 3 - 36 Adding Printer to the system... 3 - 37 Adjustment of Printer Settings... 3 - 37 UP-D898 - Printer Settings... 3 - 38 UP-D25MD - Printer Settings... 3 - 39 Setting Printer to Print Reports... 3 - 41 Setting up the Printer to Print Reports... 3 - 41 System Configuration... 3 - 42 System/General Preset Menu... 3 - 42 External I/O Connectors... 3 - 46 Available Probes... 3 - 47 Supported probes... 3 - 47 Probe Naming Conventions... 3 - 47 Probe Description... 3 - 47 Software/Option Configuration... 3 - 53 Connectivity Setup... 3 - 54 Connectivity Introduction... 3 - 54 The Dataflow Concept... 3 - 54 Dataflow Examples... 3 - 55 Stand-alone LOGIQ P9/P7... 3 - 56 LOGIQ? + PC within a “Sneaker Net”... 3 - 56 Connection between LOGIQ? and DICOM Server... 3 - 56 Wired Ethernet from LOGIQ P9/P7 to a Workstation... 3 - 57 Direct Cable Connection from the LOGIQ P9/P7 to a Workstation via a Crossover Cable... 3 - 57 Connection via a Peer-to-Peer Network... 3 - 57 Connection via Hospital Network... 3 - 57 xvi
Table of Contents
GE DIRECTION 5604324, REVISION 13
LOGIQ P9/P7 SERVICE MANUAL
You will need one network cable to connect the LOGIQ P9/P7 to a wall outlet on the hospital’s network... 3 - 57 Connection using Wireless Option... 3 - 57 Configuring Connectivity... 3 - 58 Overview... 3 - 58 Structured Reporting... 3 - 58 Supported parameters... 3 - 58 Connectivity Functions... 3 - 59 TCPIP... 3 - 60 Device... 3 - 62 Service... 3 - 63 Adding a service to a destination device... 3 - 63 Removing a service... 3 - 63 Changing parameters for a service... 3 - 64 Setting up InSite ExC Connection (R1, R2 and R2.5 only)... 3 - 65 Configuring InSite ExC... 3 - 65 Verifying InSite ExC Connection - CSD... 3 - 67 Verifying InSite ExC Connection - VCO... 3 - 69 Agent Configuration (R3 only)... 3 - 71 Agent Configuration (R3 only)... 3 - 71 Agent Configuration... 3 - 71 Verifying Back Office Connection - CSD... 3 - 73 Verifying Back Office Connection – VOC... 3 - 74 Connectivity Setup Worksheet... 3 - 76 Paperwork... 3 - 78 Product Locator Installation... 3 - 78 User Manual(s)... 3 - 78
Table of Contents
xvii
GE DIRECTION 5604324, REVISION 13
LOGIQ P9/P7 SERVICE MANUAL
CHAPTER 4 Functional Checks Overview... 4 - 1 Purpose of Chapter 4... 4 - 1 Required Equipment... 4 - 1 General Procedure... 4 - 3 System Exterior Visual Check... 4 - 4 Physical Abnormalities... 4 - 4 Appearance Inspection... 4 - 5 Appearance Inspection (R3)... 4 - 6 Mechanical Parts Functional Check... 4 - 7 Main LCD... 4 - 8 LCD ARM... 4 - 9 OPIO Swivel Lock... 4 - 10 Swivel/Brake Lock Caster... 4 - 11 Swivel/Brake Lock Caster... 4 - 12 Power On/Off... 4 - 13 Scanner Power On... 4 - 13 Sleep Mode Check... 4 - 15 Complete power down... 4 - 16 Power Off / Shutdown Check... 4 - 17 System Information... 4 - 18 Software Version... 4 - 18 Service Platform Confirmation (R1, R2, R2.5 only)... 4 - 19 USB Port Test... 4 - 20 System Integration Checks... 4 - 21 OPIO Test... 4 - 21 DVD Drive Test... 4 - 22 LAN Port Test... 4 - 22 Peripheral Checks... 4 - 23 DVR Test (if equipped)... 4 - 23 Black and White Printer Test... 4 - 23 Color Printer Test... 4 - 23 CD/DVD Read/WriteTest... 4 - 23 ECG Test... 4 - 23 Gel Warmer Test... 4 - 24 Single CWD... 4 - 24 Mode Transition Checks... 4 - 24 General Information... 4 - 24 B-Mode... 4 - 26 Color Flow-Mode... 4 - 27 Pulse Doppler Mode... 4 - 28 B/CF/PW Mode... 4 - 28 xviii
Table of Contents
GE DIRECTION 5604324, REVISION 13
LOGIQ P9/P7 SERVICE MANUAL
M-Mode... 4 - 30 B-Flow Mode... 4 - 30 CW Mode (Optional)... 4 - 31 WLAN (Optional)... 4 - 32 4D Mode (Optional)... 4 - 32 Power Assistant (Optional)... 4 - 32 OPIO Interface Check (R1, R2, R2.5 only)... 4 - 33 OPIO Interface Check (R3 only)... 4 - 36 Touch Panel Calibration (R3 only)... 4 - 39 Board Diagnostics... 4 - 42
Table of Contents
xix
GE DIRECTION 5604324, REVISION 13
LOGIQ P9/P7 SERVICE MANUAL
CHAPTER 5 Components and Functions (Theory) Overview... 5 - 1 Purpose of Chapter 5... 5 - 1 General Information... 5 - 2 System Exterior... 5 - 2 Operator Panel... 5 - 3 System Options... 5 - 5 System Ports... 5 - 6 Front USB... 5 - 7 Rear USB and LAN... 5 - 7 HDMI... 5 - 9 S-Video / Composite... 5 - 10 AC Inlet... 5 - 11 Sub System Descriptions... 5 - 12 MCB... 5 - 14 MCB Block diagram... 5 - 14 EEPROM... 5 - 15 MDC... 5 - 16 MDC Block diagram... 5 - 16 MIO Box... 5 - 18 MIO Box Block diagram... 5 - 18 MPI... 5 - 21 MPI Block diagram... 5 - 21 MBP (MARU BackPlane)... 5 - 22 HDD... 5 - 23 COMExpress... 5 - 24 Internal Cables... 5 - 26 OPIO... 5 - 28 LCD Touch Panel & Controller... 5 - 29 Trackball... 5 - 29 Temporary for Software DVR... 5 - 29 A/N keyboard(Optional)... 5 - 29 Power output of Gelwarmer... 5 - 29 LCD... 5 - 30 BIOS, Windows and Data Location... 5 - 30 BIOS Defaults... 5 - 30 Power ON Sequence... 5 - 61 Software Options... 5 - 62 xx
Table of Contents
GE DIRECTION 5604324, REVISION 13
LOGIQ P9/P7 SERVICE MANUAL
Options... 5 - 62 Smart Devices Applications (LOGIQ Apps)... 5 - 65 Hardware Options... 5 - 66 Options... 5 - 66 Regional and Peripheral Options... 5 - 68 Regional Options... 5 - 68 Peripheral Options... 5 - 68 Mechanical Descriptions... 5 - 69 Physical Dimensions... 5 - 69 LCD Monitor... 5 - 69 OPIO Positioning... 5 - 69 Air Flow Distribution... 5 - 70 Exiting to Windows Desktop... 5 - 71 Exiting to Windows Desktop... 5 - 71 Service Platform... 5 - 73 Introduction... 5 - 73 Access / Security... 5 - 73 Local Access... 5 - 73 How the Customer enables/disables Disruptive Mode and VCO . . . 5 - 74 Common Service Desktop (CSD) (R1, R2, R2.5 only)... 5 - 75 Internationalization... 5 - 75 CSD Top Page... 5 - 76 General Layout... 5 - 76 Decoding System Temperature and Voltage... 5 - 77 Error Logs... 5 - 79 Diagnostics... 5 - 79 Image Quality... 5 - 80 Configuration... 5 - 81 Utilities... 5 - 82 Disk Defragmenter... 5 - 82 Replacement... 5 - 84 PM... 5 - 84 Common Service Desktop (R3 only)... 5 - 85 Purpose of this section... 5 - 85 Disruptive mode... 5 - 85 Color statuses... 5 - 86 Licenses... 5 - 86 Table of Contents
xxi
GE DIRECTION 5604324, REVISION 13
LOGIQ P9/P7 SERVICE MANUAL
Advanced Information - Service Desktop and SSA (Secure Service Access) 5 - 90 Home... 5 - 91 Diags... 5 - 113 DICOM... 5 - 118 Utilities... 5 - 122 Options... 5 - 148 Agent Configuration... 5 - 150
xxii
Table of Contents
GE DIRECTION 5604324, REVISION 13
LOGIQ P9/P7 SERVICE MANUAL
CHAPTER 6 Service Adjustments Overview... 6 - 1 Purpose of Chapter 6... 6 - 1 Regulatory... 6 - 1 LCD Monitor Adjustment... 6 - 2 Brightness/Contrast (R1.x.x)... 6 - 4 Brightness... 6 - 4 Gamma... 6 - 4 OSD Control on the Utility mode (R1.x.x)... 6 - 5 21.5 inch Wide Monitor Adjustment (R2.x.x and later)... 6 - 6 Scan Screen... 6 - 8 Room Profile... 6 - 8 Color Profile... 6 - 8
Table of Contents
xxiii
GE DIRECTION 5604324, REVISION 13
LOGIQ P9/P7 SERVICE MANUAL
CHAPTER 7 Diagnostics/Troubleshooting Overview... 7 - 1 Purpose of Chapter 7... 7 - 1 Overview... 7 - 1 Collect Vital System Information... 7 - 2 Collecting System Information... 7 - 2 Request for Service (RFS) (R1, R2, R2.5 only)... 7 - 3 Request for Service (RFS) (R3 only)... 7 - 5 Request for Service... 7 - 5 Check Points Voltages... 7 - 7 LED for Power Status... 7 - 7 Screen Captures and Logs... 7 - 8 Capturing a screen... 7 - 8 Export Log’s and System Data... 7 - 8 Export System Data (by pressing the ALT + D key)... 7 - 8 System Warning/Errors and Logs... 7 - 9 Temperature warning... 7 - 9 Cause... 7 - 9 What to do... 7 - 9 Temperature exceeded threshold... 7 - 9 Cause... 7 - 9 What to do... 7 - 9 Log message of the high temperature... 7 - 9 System voltage failure... 7 - 10 Cause... 7 - 10 What to Do... 7 - 10 Log message of the Voltage error... 7 - 10 Hardware configuration error... 7 - 11 Cause... 7 - 11 What to do... 7 - 11 Log message of the Invalid hardware error... 7 - 11 System Error... 7 - 12 Cause... 7 - 12 What to do... 7 - 12 Log message of System error 13 Types... 7 - 13 Remote Access to Service Platform... 7 - 15 General... 7 - 15 How the Customer enables/disables Disruptive Mode and VCO... 7 - 16 xxiv
Table of Contents