GAMBRO

EasySpray System

EASYSPRAY for Open Wound Surgery Quick Reference Guide Sept 2013

Quick Reference Guide

2 Pages

EASYSPRAY Quick Reference Guide (for open wound surgery) Instructions for Circulating Nurse | EasySpray Pressure Regulator 1  2  Insert 9V battery into the EASYSPRAY pressure regulator device.  3  Connect EASYSPRAY device to IV pole or cart rail using the clamps on the back of the device.  4  Use suitable connection tube to connect the EASYSPRAY device to medical air (ranging 3.5 – 7 bar / 50 – 100 psi).  5  Connect Spray Set filters to EASYSPRAY device. Connect the blue filter to the blue female luer connector and the clear filter to the male luer connector.  6  Turn the on/off switch on the front side of the EASYSPRAY to the ON (I) position.  Check the gauge on the EASYSPRAY device for the appropriate pressure range of 1.5-2.0 bars (21.5-28.5 psi). Adjust pressure setting by turning the black pressure control knob.  Instructions for Scrub Nurse | Spray Set 1  2  Prepare TISSEEL Fibrin Sealant according to the instructions in the package insert.  3  Firmly attach the spray head to the nozzle of the syringes.  4  Fasten the pull strap to the double syringe system to assure the spray head is tightly secured.  5  Fit the connection tube of the spray set to the luer-lock connector on the underside of the spray head.  6  Attach the clip (on the end of the sensor line) by sliding it into the grooves located on the top of the syringe plunger.  Pass the assembled applicator to the surgeon for spray application. Pass the end of the connection tube with the sterile filters to the circulating nurse.  Instructions for Surgeon 1  2  3  The use of TISSEEL Fibrin Sealant is restricted to experienced surgeons who have been trained in the use of TISSEEL. In order to ensure optimal safe use of TISSEEL by spray application, apply a minimum spray distance of 10 cm and a maximum spray pressure of 2 bar to minimize the potential risk of air or gas embolism, tissue rupture, or air or gas entrapment with compression.  The EASYSPRAY device will continue to emit gas for a brief period after the thumb is removed from the clip/plunger. This delay helps to avoid clogging of the spray head. Please see the TISSEEL SmPC provided together with this material. Confirm (verbally) the actual pressure with OR personel.  Spray from a distance of 10 – 15 cm for optimum results.  To activate the flow of gas occlude the opening in the clip center with thumb. To begin application, gently depress the syringe plunger.  Caution: Any application of pressurized gas may be associated with a potential risk of air or gas embolism, tissue rupture or air or gasentrapment with compression, which may be life threatening. Be sure to take appropriate measures to address these risks by observing the recommended minimum spraying distance and the maximum pressure provided in the appropriate spray set instructions.
File Type: PDF
File Size: 259 KB
File Name: easyspray_for_open_wound_surgery_quick_reference_gu.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions