GAMBRO

Fibrinotherm Device

DUPLOSPRAY MIS Quick Reference Guide April 2012

Quick Reference Guide

2 Pages

DUPLOSPRAY MIS Gas-assisted Endoscopic Applicator Quick Reference Guide Instructions for Circulating Nurse – DUPLOSPRAY MIS Regulator For Tech Support Call 1- 877-TISSEEL Set CO2 pressure between 51-100 psi. Position DUPLOSPRAY MIS System so the foot pedal is placed next to the surgeon’s foot at time of application.  Attach black gas supply hose, located at back of regulator, to source of medical grade CO2.  Instructions for Scrub Nurse – DUPLOSPRAY MIS Applicator  1  Thread sterile replaceable tip onto applicator using tip alignment tool.  1  2  For Topical Use Only  Firmly attach the applicator to the TISSEEL syringe hubs.  3  Fasten the pull strap to the TISSEEL syringe holder to assure the spray applicator is tightly secured.  Instructions for Surgeon – DUPLOSPRAY MIS System  Depress foot pedal to start gas flow prior to applying TISSEEL. Check gas flow gauge on regulator before inserting applicator into trocar. If flow level ball does not move when foot pedal is depressed, the applicator tip is occluded and should be replaced.  For Topical Use Only  2  While activating foot switch, dispense TISSEEL through applicator tip by depressing DUPLOJECT plungers using slow, steady pressure. To stop spray delivery, release pressure on DUPLOJECT plungers while maintaining gas flow by holding down foot pedal for an additional 3-5 seconds to clear applicator tip.  Attach spray set sterile filters to regulator. Connect the blue vent line filter to the blue female Luer and the clear gas line filter to the male Luer on the regulator. For additional reference, attach filters according to graphics on regulator faceplate.  While depressing foot pedal, adjust gas flow rate to 2 liters per minute. Check gas flow by noting height of ball in flow gauge while stepping on foot pedal.  4  5  Attach gas supply line, clear Luer connector, to sterile applicator. Turn white locking collar counter clockwise to secure connection.  Attach patient vent line, red luer connector, to available female luer on trocar cannula vent valve. Ensure vent valve is fully open.  6  For Topical Use Only  Pass assembled TISSEEL [Fibrin Sealant] and spray applicator to surgeon for spray application. Pass the end of the connection tube with the sterile filters to circulating nurse.  TIPS • The patient vent line attached to the trocar cannula vent valve will only vent gas out when foot pedal is depressed. After connection to trocar cannula, ensure vent valve is fully open on trocar cannula prior to spray application. • If tip becomes occluded during use, remove plugged tip by unscrewing it counterclockwise. Using a sterile cloth, wipe any clotted material off exposed tube ends. Screw on new tip and tighten with tip alignment tool. • The twin-tube assembly can be easily separated as necessary to allow freedom of movement.  Selected Important Risk Information - Air or gas embolism has occurred when using the spray device without fibrin sealant, or fibrin sealant was administered using pressurized gas. This may occur if a spray device is used at higher than recommended pressures and/or in close proximity to the tissue surface. Please see Indications and Important Risk Information on the back. Rx Only: For safe and proper use of the DUPLOSPRAY device, please refer to full device instructions for use included.
File Type: PDF
File Size: 288 KB
File Name: duplospray_mis_quick_reference_guide_april_2012.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions