GAMBRO

Fibrinotherm Device

DUPLOSPRAY Quick Reference Guide Sept 2013

Quick Reference Guide

2 Pages

DUPLOSPRAY Quick Reference Guide (laparoscopic procedures) Instructions for Circulating Nurse | DUPLOSPRAY MIS Regulator 1  2  Position DUPLOSPRAY System so the foot pedal is placed next to the surgeon’s foot at time of application.  3  Attach gas supply hose, located at back of regulator, to source of medical grade CO2.  4  Attach spray set to regulator. Connect the blue vent line filter to the blue female luer and the clear gas line filter to the male luer on the regulator.  While depressing foot pedal, adjust gas flow rate to 1.0-2.0 litres per minute. Check gas flow by noting height of ball in flow gauge while stepping on foot pedal.  Instructions for Scrub Nurse | DUPLOSPRAY MIS Applicator 1  2  Thread sterile replaceable tip onto applicator using tip alignment tool.  3  Firmly attach the applicator to the nozzles of the double syringe.  4  Fasten the pull strap to the double syringe holder to assure the spray applicator is tightly secured.  5  Attach gas supply line (clear luer connector) to sterile applicator. Turn white locking collar to secure connection.  6  Pass assembled double syringe and spray applicator to surgeon for spray application.  Attach patient vent line (red luer connector) to available female luer on trocar vent valve. Ensure vent valve is fully open.  Instructions for Surgeon 1  2  3  The use of TISSEEL Fibrin Sealant is restricted to experienced surgeons who have been trained in the use of TISSEEL. In order to ensure optimal safe use of TISSEEL by spray application, apply a minimum spray distance of 2 cm and a maximum spray pressure of 1.5 bar to minimise the potential risk of air or gas embolism, tissue rupture, or air or gas entrapment with compression.  TIPS • The patient vent line attached to the trocar cannula vent valve will only vent gas out when foot pedal is depressed. After connection to trocar cannula, ensure vent valve is fully open on trocar cannula prior to spray application. Confirm actual flow of max 2 litres/min with theatre personnel.  Depress foot pedal to start gas flow prior to applying TISSEEL Fibrin Sealant. Check gas flow gauge on regulator before inserting applicator. If flow level ball does not move when foot pedal is depressed, the applicator tip is occluded and should be replaced.  While activating foot pedal dispense TISSEEL Fibrin Sealant through applicator tip by depressing double syringe plungers using very slow, steady pressure. To stop spray delivery release pressure on plungers while maintaining gas flow by holding down foot pedal for an additional 3-5 seconds to clear applicator tip.  • If tip becomes occluded during use, remove plugged tip by unscrewing it counterclockwise. Using a sterile cloth, wipe any clotted material off exposed tube ends. Screw on new tip and tighten with finger pressure. • The twin-tube assembly can be easily separated as necessary to allow freedom of movement. Please see the TISSEEL SmPC provided together with this material.
File Type: PDF
File Size: 224 KB
File Name: duplospray_quick_reference_guide_sept_2013.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions