GAMBRO

Fibrinotherm Device

EASYSPRAY Pressure Regulator Quick Reference Guide Sept 2015

Quick Reference Guide

2 Pages

1  1  1  Connect EASYSPRAY device to IV pole or cart rail using the clamps on the back of the device.  3  Connect the adapter attached to the black tubing, located at the side of the EASYSPRAY device, to an appropriate gas source. Pressurized gas supply must be set between 3.5 and 7 bar (51-100 psi).  A spraying distance of 10 –15 cm is recommended. Note that the spraying distance should not be less than 10 cm (3.9”) and the maximum pressure should not exceed 2 bars (29.5psi).  2  For Topical Use Only  Firmly attach the spray head to the nozzle of the syringes by aligning the blue dot on the spray head to the blue dot on the syringes.  To activate the flow of gas, occlude the opening in the clip center with thumb. To begin application, gently depress the TISSEEL syringe plunger.  Instructions for Surgeon  Prepare TISSEEL [Fibrin Sealant] according to the instructions in the package insert.  For Topical Use Only  2  3  Fasten the pull strap to the double syringe system to assure the spray head is tightly secured.  For Topical Use Only  Instructions for Scrub Nurse | Spray Set for TISSEEL [Fibrin Sealant]  Insert 9V battery into the EASYSPRAY pressure regulator device.  2  Instructions for Circulating Nurse | EASYSPRAY Device  4  4  5  Attach the clip (on the end of the sensor line) by sliding it into the grooves located on the top of the syringe plunger.  For Topical Use Only  Turn the on/off switch on the front side of the EASYSPRAY device to the ON position. The low-battery indicator light will only illuminate when the battery is weak and when the gas flow is activated. If the battery is completely dead, the lowbattery indicator will not illuminate.  6  6  Pass the end of the connection tube with the sterile filters to the circulating nurse.  Pass the assembled TISSEEL syringe to the surgeon for spray application.  For Topical Use Only  Check the gauge on the EASYSPRAY device for the appropriate pressure range of 1.5-2.0 bars (21.8-29 psi). Adjust pressure setting by turning the black pressure control knob.  For Tech Support Call 1-888-229-0001,option 4  Do Not connect to an oxygen source. Do Not use rechargable batteries.  Rx Only: For safe and proper use of these devices, please refer to the appropriate full device Instructions for Use included.  Please see Indications and Detailed Important Risk Information for TISSEEL [Fibrin Sealant] on the reverse side.  Air or gas embolism has occurred when fibrin sealant was administered using pressurized gas. This can occur if a spray device is used at higher than recommended pressures and in closer than recommended proximity to the tissue surface.  Selected Important Risk Information  The EASYSPRAY device will continue to emit gas for a brief period after the thumb is removed from the clip/plunger. This delay helps to avoid clogging of the spray head.  TIPS  Fit the connection tube of the spray set to the Luer-lock connector on the underside of the spray head.  For Topical Use Only  Connect Spray Set filters to EASYSPRAY device. Connect the blue filter to the blue female Luer connector and the clear filter to the male Luer connector.  5  EASYSPRAY PRESSURE REGULATOR QUICK REFERENCE GUIDE
File Type: PDF
File Size: 160 KB
File Name: easyspray_pressure_regulator_quick_reference_guide_.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions