GE Healthcare
Definium™ 6000 Illustrated Parts List
Direction 5135606-100 Revision 5
GE HEALTHCARE DIRECTION 5135606-100, REVISION 5
DEFINIUM™ 6000 ILLUSTRATED PARTS LIST
Published by GE Healthcare Erna Yan
Page 2
GE HEALTHCARE DIRECTION 5135606-100, REVISION 5
DEFINIUM™ 6000 ILLUSTRATED PARTS LIST
IMPORTANT PRECAUTIONS
Important Precautions
Page 3
GE HEALTHCARE DIRECTION 5135606-100, REVISION 5
DEFINIUM™ 6000 ILLUSTRATED PARTS LIST
LANGUAGE
警告
• 本维修手册仅提供英文版本。
(ZH-CN)
• 如果维修服务提供商需要非英文版本,客户需自行提供翻译服务。 • 未详细阅读和完全理解本维修手册之前,不得进行维修。 • 忽略本警告可能对维修人员,操作员或患者造成触电、机械伤害或其他形式的伤害。
VÝSTRAHA (CS)
• TENTO PROVOZNÍ NÁVOD EXISTUJE POUZE V ANGLICKÉM JAZYCE. • V PŘÍPADĚ, ŽE EXTERNÍ SLUŽBA ZÁKAZNÍKŮM POTŘEBUJE NÁVOD V JINÉM JAZYCE, JE ZAJIŠTĚNÍ PŘEKLADU DO ODPOVÍDAJÍCÍHO JAZYKA ÚKOLEM ZÁKAZNÍKA. • NESNAŽTE SE O ÚDRŽBU TOHOTO ZAŘÍZENÍ, ANIŽ BYSTE SI PŘEČETLI TENTO PROVOZNÍ NÁVOD A POCHOPILI JEHO OBSAH. • V PŘÍPADĚ NEDODRŽOVÁNÍ TÉTO VÝSTRAHY MŮŽE DOJÍT K PORANĚNÍ PRACOVNÍKA PRODEJNÍHO SERVISU, OBSLUŽNÉHO PERSONÁLU NEBO PACIENTŮ VLIVEM ELEKTRICKÉHOP PROUDU, RESPEKTIVE VLIVEM MECHANICKÝCH ČI JINÝCH RIZIK.
ADVARSEL (DA)
• DENNE SERVICEMANUAL FINDES KUN PÅ ENGELSK. • HVIS EN KUNDES TEKNIKER HAR BRUG FOR ET ANDET SPROG END ENGELSK, ER DET KUNDENS ANSVAR AT SØRGE FOR OVERSÆTTELSE. • FORSØG IKKE AT SERVICERE UDSTYRET MEDMINDRE DENNE SERVICEMANUAL HAR VÆRET KONSULTERET OG ER FORSTÅET. • MANGLENDE OVERHOLDELSE AF DENNE ADVARSEL KAN MEDFØRE SKADE PÅ GRUND AF ELEKTRISK, MEKANISK ELLER ANDEN FARE FOR TEKNIKEREN, OPERATØREN ELLER PATIENTEN.
Page 4
Important Precautions
GE HEALTHCARE DIRECTION 5135606-100, REVISION 5
DEFINIUM™ 6000 ILLUSTRATED PARTS LIST
WAARSCHUWING • DEZE ONDERHOUDSHANDLEIDING IS ENKEL IN HET ENGELS VERKRIJGBAAR. (NL)
• ALS HET ONDERHOUDSPERSONEEL EEN ANDERE TAAL VEREIST, DAN IS DE KLANT VERANTWOORDELIJK VOOR DE VERTALING ERVAN. • PROBEER DE APPARATUUR NIET TE ONDERHOUDEN VOORDAT DEZE NDERHOUDSHANDLEIDING WERD GERAADPLEEGD EN BEGREPEN IS. • INDIEN DEZE WAARSCHUWING NIET WORDT OPGEVOLGD, ZOU HET ONDERHOUDSPERSONEEL, DE OPERATOR OF EEN PATIËNT GEWOND KUNNEN RAKEN ALS GEVOLG VAN EEN ELEKTRISCHE SCHOK, MECHANISCHE OF ANDERE GEVAREN.
WARNING (EN)
• • • •
HOIATUS (ET)
THIS SERVICE MANUAL IS AVAILABLE IN ENGLISH ONLY. IF A CUSTOMER’S SERVICE PROVIDER REQUIRES A LANGUAGE OTHER THAN ENGLISH, IT IS THE CUSTOMER’S RESPONSIBILITY TO PROVIDE TRANSLATION SERVICES. DO NOT ATTEMPT TO SERVICE THE EQUIPMENT UNLESS THIS SERVICE MANUAL HAS BEEN CONSULTED AND IS UNDERSTOOD. FAILURE TO HEED THIS WARNING MAY RESULT IN INJURY TO THE SERVICE PROVIDER, OPERATOR OR PATIENT FROM ELECTRIC SHOCK, MECHANICAL OR OTHER HAZARDS.
• KÄESOLEV TEENINDUSJUHEND ON SAADAVAL AINULT INGLISE KEELES. • KUI KLIENDITEENINDUSE OSUTAJA NÕUAB JUHENDIT INGLISE KEELEST ERINEVAS KEELES, VASTUTAB KLIENT TÕLKETEENUSE OSUTAMISE EEST. • ÄRGE ÜRITAGE SEADMEID TEENINDADA ENNE EELNEVALT KÄESOLEVA TEENINDUSJUHENDIGA TUTVUMIST JA SELLEST ARU SAAMIST. • KÄESOLEVA HOIATUSE EIRAMINE VÕIB PÕHJUSTADA TEENUSEOSUTAJA, OPERAATORI VÕI PATSIENDI VIGASTAMIST ELEKTRILÖÖGI, MEHAANILISE VÕI MUU OHU TAGAJÄRJEL.
Important Precautions
Page 5
GE HEALTHCARE DIRECTION 5135606-100, REVISION 5
VAROITUS (FI)
DEFINIUM™ 6000 ILLUSTRATED PARTS LIST
• TÄMÄ HUOLTO-OHJE ON SAATAVILLA VAIN ENGLANNIKSI. • JOS ASIAKKAAN HUOLTOHENKILÖSTÖ VAATII MUUTA KUIN ENGLANNINKIELISTÄ MATERIAALIA, TARVITTAVAN KÄÄNNÖKSEN HANKKIMINEN ON ASIAKKAAN VASTUULLA. • ÄLÄ YRITÄ KORJATA LAITTEISTOA ENNEN KUIN OLET VARMASTI LUKENUT JA YMMÄRTÄNYT TÄMÄN HUOLTO-OHJEEN. • MIKÄLI TÄTÄ VAROITUSTA EI NOUDATETA, SEURAUKSENA VOI OLLA HUOLTOHENKILÖSTÖN, LAITTEISTON KÄYTTÄJÄN TAI POTILAAN VAHINGOITTUMINEN SÄHKÖISKUN, MEKAANISEN VIAN TAI MUUN VAARATILANTEEN VUOKSI.
ATTENTION (FR)
• • • •
WARNUNG (DE)
CE MANUEL DE MAINTENANCE N’EST DISPONIBLE QU’EN ANGLAIS. SI LE TECHNICIEN DU CLIENT A BESOIN DE CE MANUEL DANS UNE AUTRE LANGUE QUE L’ANGLAIS, C’EST AU CLIENT QU’IL INCOMBE DE LE FAIRE TRADUIRE. NE PAS TENTER D’INTERVENTION SUR LES ÉQUIPEMENTS TANT QUE LE MANUEL SERVICE N’A PAS ÉTÉ CONSULTÉ ET COMPRIS. LE NON-RESPECT DE CET AVERTISSEMENT PEUT ENTRAÎNER CHEZ LE TECHNICIEN, L’OPÉRATEUR OU LE PATIENT DES BLESSURES DUES À DES DANGERS ÉLECTRIQUES, MÉCANIQUES OU AUTRES.
• DIESE SERVICEANLEITUNG EXISTIERT NUR IN ENGLISCHER SPRACHE. • FALLS EIN FREMDER KUNDENDIENST EINE ANDERE SPRACHE BENÖTIGT, IST ES AUFGABE DES KUNDEN FÜR EINE ENTSPRECHENDE ÜBERSETZUNG ZU SORGEN. • VERSUCHEN SIE NICHT DIESE ANLAGE ZU WARTEN, OHNE DIESE SERVICEANLEITUNG GELESEN UND VERSTANDEN ZU HABEN. • WIRD DIESE WARNUNG NICHT BEACHTET, SO KANN ES ZU VERLETZUNGEN DES KUNDENDIENSTTECHNIKERS, DES BEDIENERS ODER DES PATIENTEN DURCH STROMSCHLÄGE, MECHANISCHE ODER SONSTIGE GEFAHREN KOMMEN.
Page 6
Important Precautions
GE HEALTHCARE DIRECTION 5135606-100, REVISION 5
AÐVÖRUN (IS)
DEFINIUM™ 6000 ILLUSTRATED PARTS LIST
• ÞESSI ÞJÓNUSTUHANDBÓK ER EINGÖNGU FÁANLEG Á ENSKU. • EF AÐ ÞJÓNUSTUVEITANDI VIÐSKIPTAMANNS ÞARFNAST ANNAS TUNGUMÁLS EN ENSKU, ER ÞAÐ SKYLDA VIÐSKIPTAMANNS AÐ SKAFFA TUNGUMÁLAÞJÓNUSTU. • REYNIÐ EKKI AÐ AFGREIÐA TÆKIÐ NEMA AÐ ÞESSI ÞJÓNUSTUHANDBÓK HEFUR VERIÐ SKOÐUÐ OG SKILIN. • BROT Á SINNA ÞESSARI AÐVÖRUN GETUR LEITT TIL MEIÐSLA Á ÞJÓNUSTUVEITANDA, STJÓRNANDA EÐA SJÚKLINGS FRÁ RAFLOSTI, VÉLRÆNU EÐA ÖÐRUM ÁHÆTTUM.
AVVERTENZA (IT)
• •
• •
Page 8
IL PRESENTE MANUALE DI MANUTENZIONE È DISPONIBILE SOLTANTO IN INGLESE. SE UN ADDETTO ALLA MANUTENZIONE ESTERNO ALLA GEMS RICHIEDE IL MANUALE IN UNA LINGUA DIVERSA, IL CLIENTE È TENUTO A PROVVEDERE DIRETTAMENTE ALLA TRADUZIONE. SI PROCEDA ALLA MANUTENZIONE DELL’APPARECCHIATURA SOLO DOPO AVER CONSULTATO IL PRESENTE MANUALE ED AVERNE COMPRESO IL CONTENUTO. IL NON RISPETTO DELLA PRESENTE AVVERTENZA POTREBBE FAR COMPIERE OPERAZIONI DA CUI DERIVINO LESIONI ALL’ADDETTO ALLA MANUTENZIONE, ALL’UTILIZZATORE ED AL PAZIENTE PER FOLGORAZIONE ELETTRICA, PER URTI MECCANICI OD ALTRI RISCHI.
Important Precautions
GE HEALTHCARE DIRECTION 5135606-100, REVISION 5
BRĪDINĀJUMS (LV)
DEFINIUM™ 6000 ILLUSTRATED PARTS LIST
• ŠĪ APKALPES ROKASGRĀMATA IR PIEEJAMA TIKAI ANGĻU VALODĀ. • JA KLIENTA APKALPES SNIEDZĒJAM NEPIECIEŠAMA INFORMĀCIJA CITĀ VALODĀ, NEVIS ANGĻU, KLIENTA PIENĀKUMS IR NODROŠINĀT TULKOŠANU. • NEVEICIET APRĪKOJUMA APKALPI BEZ APKALPES ROKASGRĀMATAS IZLASĪŠANAS UN SAPRAŠANAS. • ŠĪ BRĪDINĀJUMA NEIEVĒROŠANA VAR RADĪT ELEKTRISKĀS STRĀVAS TRIECIENA, MEHĀNISKU VAI CITU RISKU IZRAISĪTU TRAUMU APKALPES SNIEDZĒJAM, OPERATORAM VAI PACIENTAM.
ĮSPĖJIMAS (LT)
• ŠIS EKSPLOATAVIMO VADOVAS YRA PRIEINAMAS TIK ANGLŲ KALBA. • JEI KLIENTO PASLAUGŲ TIEKĖJAS REIKALAUJA VADOVO KITA KALBA – NE ANGLŲ, NUMATYTI VERTIMO PASLAUGAS YRA KLIENTO ATSAKOMYBĖ. • NEMĖGINKITE ATLIKTI ĮRANGOS TECHNINĖS PRIEŽIŪROS, NEBENT ATSIŽVELGĖTE Į ŠĮ EKSPLOATAVIMO VADOVĄ IR JĮ SUPRATOTE. • JEI NEATKREIPSITE DĖMESIO Į ŠĮ PERSPĖJIMĄ, GALIMI SUŽALOJIMAI DĖL ELEKTROS ŠOKO. • MECHANINIŲ AR KITŲ PAVOJŲ PASLAUGŲ TIEKĖJUI, OPERATORIUI AR PACIENTUI.
ADVARSEL (NO)
• DENNE SERVICEHÅNDBOKEN FINNES BARE PÅ ENGELSK. • HVIS KUNDENS SERVICELEVERANDØR TRENGER ET ANNET SPRÅK, ER DET KUNDENS ANSVAR Å SØRGE FOR OVERSETTELSE. • IKKE FORSØK Å REPARERE UTSTYRET UTEN AT DENNE SERVICEHÅNDBOKEN ER LEST OG FORSTÅTT. • MANGLENDE HENSYN TIL DENNE ADVARSELEN KAN FØRE TIL AT SERVICELEVERANDØREN, OPERATØREN ELLER PASIENTEN SKADES PÅ GRUNN AV ELEKTRISK STØT, MEKANISKE ELLER ANDRE FARER.
Page 10
Important Precautions
GE HEALTHCARE DIRECTION 5135606-100, REVISION 5
OSTRZEŻENIE (PL)
DEFINIUM™ 6000 ILLUSTRATED PARTS LIST
• NINIEJSZY PODRĘCZNIK SERWISOWY DOSTĘPNY JEST JEDYNIE W JĘZYKU ANGIELSKIM. • JEŚLI DOSTAWCA USŁUG KLIENTA WYMAGA JĘZYKA INNEGO NIŻ ANGIELSKI, ZAPEWNIENIE USŁUGI TŁUMACZENIA JEST OBOWIĄZKIEM KLIENTA. • NIE PRÓBOWAĆ SERWISOWAĆ WYPOSAŻENIA BEZ ZAPOZNANIA SIĘ I ZROZUMIENIA NINIEJSZEGO PODRĘCZNIKA SERWISOWEGO. • NIEZASTOSOWANIE SIĘ DO TEGO OSTRZEŻENIA MOŻE SPOWODOWAĆ URAZY DOSTAWCY USŁUG, OPERATORA LUB PACJENTA W WYNIKU PORAŻENIA ELEKTRYCZNEGO, ZAGROŻENIA MECHANICZNEGO BĄDŹ INNEGO.
ATENÇÃO (PT)
• ESTE MANUAL DE ASSISTÊNCIA TÉCNICA SÓ SE ENCONTRA DISPONÍVEL EM INGLÊS. • SE QUALQUER OUTRO SERVIÇO DE ASSISTÊNCIA TÉCNICA, QUE NÃO A GEMS, SOLICITAR ESTES MANUAIS NOUTRO IDIOMA, É DA RESPONSABILIDADE DO CLIENTE FORNECER OS SERVIÇOS DE TRADUÇÃO. • NÃO TENTE REPARAR O EQUIPAMENTO SEM TER CONSULTADO E COMPREENDIDO ESTE MANUAL DE ASSISTÉNCIA TÉCNICA • O NÃO CUMPRIMENTO DESTE AVISO PODE POR EM PERIGO A SEGURANÇA DO TÉCNICO, OPERADOR OU PACIENTE DEVIDO A CHOQUES ELÉTRICOS, MECÂNICOS OU OUTROS.
Important Precautions
Page 11
GE HEALTHCARE DIRECTION 5135606-100, REVISION 5
UPOZORNENIE (SK)
DEFINIUM™ 6000 ILLUSTRATED PARTS LIST
• TENTO NÁVOD NA OBSLUHU JE K DISPOZÍCII LEN V ANGLIČTINE. • AK ZÁKAZNÍKOV POSKYTOVATEĽ SLUŽIEB VYŽADUJE INÝ JAZYK AKO ANGLIČTINU, POSKYTNUTIE PREKLADATEĽSKÝCH SLUŽIEB JE ZODPOVEDNOSŤOU ZÁKAZNÍKA. • NEPOKÚŠAJTE SA O OBSLUHU ZARIADENIA SKÔR, AKO SI NEPREČÍTATE NÁVOD NA OBLUHU A NEPOROZUMIETE MU. • ZANEDBANIE TOHTO UPOZORNENIA MÔŽE VYÚSTIŤ DO ZRANENIA POSKYTOVATEĽA SLUŽIEB, OBSLUHUJÚCEJ OSOBY ALEBO PACIENTA ELEKTRICKÝM PRÚDOM, DO MECHANICKÉHO ALEBO INÉHO NEBEZPEČENSTVA.
ATENCION (ES)
• ESTE MANUAL DE SERVICIO SOLO EXISTE EN INGLES. • SI ALGUN PROVEEDOR DE SERVICIOS AJENO A GEMS SOLICITA UN IDIOMA QUE NO SEA EL INGLES, ES RESPONSABILIDAD DEL CLIENTE OFRECER UN SERVICIO DE TRADUCCION. • NO SE DEBERA DAR SERVICIO TECNICO AL EQUIPO, SIN HABER CONSULTADO Y COMPRENDIDO ESTE MANUAL DE SERVICIO. • LA NO OBSERVANCIA DEL PRESENTE AVISO PUEDE DAR LUGAR A QUE EL PROVEEDOR DE SERVICIOS, EL OPERADOR O EL PACIENTE SUFRAN LESIONES PROVOCADAS POR CAUSAS ELÉCTRICAS, MECÁNICAS O DE OTRA NATURALEZA.
Important Precautions
Page 13
GE HEALTHCARE DIRECTION 5135606-100, REVISION 5
DEFINIUM™ 6000 ILLUSTRATED PARTS LIST
VARNING
• DEN HÄR SERVICEHANDBOKEN FINNS BARA TILLGÄNGLIG PÅ ENGELSKA.
(SV)
• OM EN KUNDS SERVICETEKNIKER HAR BEHOV AV ETT ANNAT SPRÅK ÄN ENGELSKA ANSVARAR KUNDEN FÖR ATT TILLHANDAHÅLLA ÖVERSÄTTNINGSTJÄNSTER. • FÖRSÖK INTE UTFÖRA SERVICE PÅ UTRUSTNINGEN OM DU INTE HAR LÄST OCH FÖRSTÅR DEN HÄR SERVICEHANDBOKEN. • OM DU INTE TAR HÄNSYN TILL DEN HÄR VARNINGEN KAN DET RESULTERA I SKADOR PÅ SERVICETEKNIKERN, OPERATÖREN ELLER PATIENTEN TILL FÖLJD AV ELEKTRISKA STÖTAR, MEKANISKA FAROR ELLER ANDRA FAROR.
DİKKAT (TR)
• BU SERVİS KILAVUZUNUN SADECE İNGİLİZCESİ MEVCUTTUR. • EĞER MÜŞTERİ TEKNİSYENİ BU KILAVUZU İNGİLİZCE DIŞINDA BİR BAŞKA LİSANDAN TALEP EDERSE, BUNU TERCÜME ETTİRMEK MÜŞTERİYE DÜŞER. • SERVİS KILAVUZUNU OKUYUP ANLAMADAN EKİPMANLARA MÜDAHALE ETMEYİNİZ. • BU UYARIYA UYULMAMASI, ELEKTRİK, MEKANİK VEYA DİĞER TEHLİKELERDEN DOLAYI TEKNİSYEN, OPERATÖR VEYA HASTANIN YARALANMASINA YOL AÇABİLİR.
DAMAGE IN TRANSPORTATION All packages should be closely examined at time of delivery. If damage is apparent write “Damage In Shipment” on ALL copies of the freight or express bill BEFORE delivery is accepted or “signed for” by a GE representative or hospital receiving agent. Whether noted or concealed, damage MUST be reported to the carrier immediately upon discovery, or in any event, within 14 days after receipt, and the contents and containers held for inspection by the carrier. A transportation company will not pay a claim for damage if an inspection is not requested within this 14 day period. Call GEHC Global Parts 1-800-548-3366 and select option 8, immediately after damage is found. At this time be ready to supply name of carrier, delivery date, consignee name, freight or express bill number, item damaged and extent of damage. Complete instructions regarding claim procedure are found in Section S of the Policy And Procedures Bulletins. 14 July 1993
Page 14
Important Precautions
GE HEALTHCARE DIRECTION 5135606-100, REVISION 5
DEFINIUM™ 6000 ILLUSTRATED PARTS LIST
CERTIFIED ELECTRICAL CONTRACTOR STATEMENT All electrical Installations that are preliminary to positioning of the equipment at the site prepared for the equipment shall be performed by licensed electrical contractors. In addition, electrical feeds into the Power Distribution Unit shall be performed by licensed electrical contractors. Other connections between pieces of electrical equipment, calibrations and testing shall be performed by qualified GE Healthcare personnel. The products involved (and the accompanying electrical installations) are highly sophisticated, and special engineering competence is required. In performing all electrical work on these products, GE will use its own specially trained field engineers. All of GE’s electrical work on these products will comply with the requirements of the applicable electrical codes. The purchaser of GE equipment shall only utilize qualified personnel (i.e., GE’s field engineers, personnel of third-party service companies with equivalent training, or licensed electricians) to perform electrical servicing on the equipment.
IMPORTANT...X-RAY PROTECTION X-ray equipment if not properly used may cause injury. Accordingly, the instructions herein contained should be thoroughly read and understood by everyone who will use the equipment before you attempt to place this equipment in operation. The General Electric Company, He Healthcare Technologies, will be glad to assist and cooperate in placing this equipment in use. Although this apparatus incorporates a high degree of protection against x-radiation other than the useful beam, no practical design of equipment can provide complete protection. Nor can any practical design compel the operator to take adequate precautions to prevent the possibility of any persons carelessly exposing themselves or others to radiation. It is important that anyone having anything to do with x-radiation be properly trained and fully acquainted with the recommendations of the National Council on Radiation Protection and Measurements as published in NCRP Reports available from NCRP Publications, 7910 Woodmont Avenue, Room 1016, Bethesda, Maryland 20814, and of the International Commission on Radiation Protection, and take adequate steps to protect against injury. The equipment is sold with the understanding that the General Electric Company, GE Healthcare Technologies’ agents and representatives have no responsibility for injury or damage which may result from improper use of the equipment. Various protective materials and devices are available. It is urged that such materials or devices be used.
DOCUMENTATION OMISSIONS & ERRORS Customers, please contact your GE Sales or Service representatives. GE personnel, please use the GEHC CQA process to report all omissions, errors, and defects in this document.
Important Precautions
Page 15
GE HEALTHCARE DIRECTION 5135606-100, REVISION 5
DEFINIUM™ 6000 ILLUSTRATED PARTS LIST This page is intentionally left blank.
Page 16
Important Precautions
GE HEALTHCARE DIRECTION 5135606-100, REVISION 5
DEFINIUM™ 6000 ILLUSTRATED PARTS LIST
Revision History Revision
Date
Reason for change
1
Jan. 15, 2006 Initial Release
2
May 20, 2006 Update Product Name
3
Nov. 30, 2006 Update Drawings
4
May.10, 2007 Update BOM and Drawings
5
Oct. 20, 2007 Add New Tube and Portable Rad Tether FRU Kit
Revision History
Page 17
GE HEALTHCARE DIRECTION 5135606-100, REVISION 5
DEFINIUM™ 6000 ILLUSTRATED PARTS LIST
List of Effected Pages
Page 18
PAGES
REVISION
PAGES
REVISION
1 through 160
1
1 through 358
5
1 through 268
2
1 through 268
3
1 through 356
4
Revision History
PAGES
REVISION
GE HEALTHCARE DIRECTION 5135606-100, REVISION 5
DEFINIUM™ 6000 ILLUSTRATED PARTS LIST
Table of Contents Chapter 1 - System Overview... 31 Section 1.0 Base Systems ... 31
Chapter 2 - Systems... 33 Section 1.0 Base Systems ... 33 1.1 1.2 1.3 1.4 1.5
S3921JA, FeiTian 65kW System... 33 S3921JB, FeiTian 80kW System... 34 2266999, Collimator ... 35 5143310, Ion Chamber... 35 5147707, Detector ... 36
Section 2.0 System Options ... 37 2.1 2.2 2.3
S3921LJ, Bar Code Reader ... 38 S3921KM, Grid Box... 38 2.2.1 2329054, GRID HOLDER ASSEMBLY... 38 S3918JW, Patient Compress Band ... 39 2.3.1 618-3000,Pression Belt Awlm ... 39 2.3.2 618-3100,Pression Belt B ... 40
Chapter 3 - System Cables ... 43 Section 1.0 System MIS Cables... 44
Table of Contents
Page 19
GE HEALTHCARE DIRECTION 5135606-100, REVISION 5
DEFINIUM™ 6000 ILLUSTRATED PARTS LIST
Chapter 4 - Operators Console & Software ... 45 Section 1.0 Console Hardware ... 45 Section 2.0 5159843, System Software... 46 2.1 2.2 2.3
5160479, FeiTian Apps ... 46 5160480, Linux OS... 46 5160481, FeiTian Demo Images - 1CD... 46
Chapter 5 - Radiographic Stretcher Table, 5136793 ... 47 Section 1.0 5161113, Table Assembly ... 48 1.1
1.2 1.3
1.4
5160493, Table Top ... 50 1.1.1 5137527, Table top plate ... 51 1.1.2 5137526, Table Top Rail... 52 5160496, Top End Assembly ... 53 1.2.1 5138716, Grip Assembly... 54 5160497, Table Bottom Assembly... 55 1.3.1 5160498, Brake Mechanism ... 57 1.3.1.1
5137538, Rotation Pole Assembly ... 59
1.3.1.2
5137547, Driving Pole Assembly... 60
1.3.2 5137541, Bottom Rail Assembly ... 61 1.3.3 5137551, Foot Pedal Assembly A... 62 1.3.4 5138732, Foot Pedal Assembly B... 63 5160295, Fix Block ... 64
Chapter 6 - System Cabinet, 5128145 ... 65 Section 1.0 5128148, System Cabinet Shell ... 73 Page 20
Table of Contents
GE HEALTHCARE DIRECTION 5135606-100, REVISION 5
1.1
1.2 1.3
DEFINIUM™ 6000 ILLUSTRATED PARTS LIST
5141701, Frame Weldment ... 75 1.1.1 2351792,ARETHA BOTTOM GUSSET WELDMENT... 75 1.1.2 5141708, MAIN SHELF WELDMENT ... 75 1.1.3 5141711,TOP WELDMENT ... 75 5141718, Front Door Weldment ... 76 2352074, PDU Tray Weldment... 76
Section 2.0 2352199, Main Power Switch ... 77 Section 3.0 2381501,ROTATION TO BULKHEAD CABLE FOR LINGTNING ... 79 Section 4.0 2374870, Generator (JEDI 80 RD 1T)... 81 4.1
2375932, JEDI POWER MODULE 100 RD... 82 4.1.1 2348788,CHASSIS CONTROL... 85 4.1.2 2348785,CONTROLE MODULE COVER ... 86 4.1.3 2268972,INVERTER POWER ASSY... 87
4.1.4
4.1.3.1
2366109,CONNEX IGBT1-2 IGBT3-4 INSULATED... 89
4.1.3.2
2272812,INVERTER COIL POWER ASSY... 89
4.1.3.3
2198185,KV MEASURE - GATE CMDE CABLE... 89
4.1.3.4
2249993,QUAD SNUB/GATE CMD DC BUS CABLE... 90
2268587,CAPA INVERTER POWER ASSY (EUROFARAD) ... 91 4.1.4.1
4.1.5
2252099,CURRENT TRANSFO ASSY ... 93
2377316,PARALLELE CHOKE EQUIPED TEMP SENSOR ... 94 4.1.5.1
2298584,PARRALLEL CHOKE TEMP SENSOR CABLE ... 95
4.1.6 2300158, KV CONTROLE /KV MEASURE... 96 4.1.7 2307356,KV MEASURE-FILAMENT CABLE... 98 4.1.8 2351200-22, PROGRAMMED KV CTRL P6.33BF3 ... 99 4.1.9 2300154, GENERIC IF/KV CONTROLE CABLE ... 100 4.1.10 2292876, CABLE AEC1 9 PINS... 101 4.1.11 2292876-2, CABLE AEC2 9 PINS ... 103 Table of Contents
Page 21
GE HEALTHCARE DIRECTION 5135606-100, REVISION 5
4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9
DEFINIUM™ 6000 ILLUSTRATED PARTS LIST
4.1.12 2294420, GEN IF / AEC CABLE ... 105 4.1.13 2307965, INVERTER INTERNAL DC BUS_CABLE... 107 4.1.14 2395146,INVERTER INTERNAL CABLE ... 108 4.1.15 2409046-2,GENERIC IF BOARD V2 FRU... 108 4.1.16 2409243,INVERTER SPARE 100 VAS 1T ... 109 2186730, JEDI STD HV TANK ... 110 2372292, EQUIPPED AC/DC... 112 2381787, AUXILLIARY MODULE 80 RD 1T ... 114 2383144, INTER MODULE CABLE (80 RD 1T)... 115 2387181, KIT JEDI IN ATLAS (80 RD 1T) ... 116 2353387, FIRST AID SPARES... 116 2375934, LABELLING FOR GENERATOR 80 RD 1T ... 117 2375935, LABELLING FOR SYSTEM (RD 1T)... 117
Section 5.0 2315938, Fuses Box... 118 Section 6.0 5162126, CD ROM APPLI ZENITH RTAC DL JEDI POSI ITU ... 119
Chapter 7 - Overhead Tube Suspension, 5139720 ... 121 Section 1.0 5140120, Longitudinal Rail ASM... 125 Section 2.0 5139994, Mainbody Mount ASM ... 127 2.1
5140970, FeiTian Section 0# ASM... 131 2.1.1 5139896, 4# Section ASM ... 133 2.1.1.1
2.1.2
Page 22
5140866, Inner Rail Weldment ASM ... 135
5140966, Section 1# ASM ... 136
Table of Contents
GE HEALTHCARE DIRECTION 5135606-100, REVISION 5
DEFINIUM™ 6000 ILLUSTRATED PARTS LIST 2.1.2.1
5139916, Column 1# ... 137 5140864, Pully Bracket ASM ... 139
2.1.2.2
5140862, Bogie Bar Link ASM ... 141 5139925, Bogie Bar ASM ... 142
2.1.3
5140967, Section 2# ASM ... 144 2.1.3.1
2.1.4
5140968, Section 3# ASM ... 147 2.1.4.1
2.1.5
2.3 2.4 2.5 2.6 2.7 2.8
5139923, Column 3# ... 148
5140969, Section 4# ASM ... 150 2.1.5.1
2.2
5139921, Column 2# ... 145
5139941, Column 0# ... 152
2.1.6 5139950, J Bar... 154 2.1.7 5141147, Cable Tie ASM in Section 1# ... 155 2.1.8 5141148, Cable Tie ASM in Section 2# & 3#... 157 5139951, FeiTian OTS Gooseneck ... 158 2.2.1 5139953, Gooseneck Shaft ASM... 160 2.2.2 5139952, Gooseneck Hub ASM... 160 2.2.3 5151837, Column Rotation Kit ... 161 5139996, Main Reel ASM... 162 5139998, Safety Reel ASM ... 164 2.4.1 5140002, Plate ASM ... 166 5151838, Motorization Kit... 167 5140003, Counterpoise Set ASM ... 169 5151839, Vertical Encoder Kit ... 171 5140351, Lateral Feedback ASM ... 171
Section 3.0 5139887, OTS Cable... 173 3.1
5140006, Cable Arm ASM... 177
Section 4.0 5161386, OTS Cover ASM ... 178 4.1
5140340, Cover ASM for OTS Carriage... 179 Table of Contents
Page 23