Service Manual
530 Pages
Preview
Page 1
Technical Publications 5764770--1EN Revision 5
Proteus XR/f Generator Manual
Proteus XR/f Generator
GE Healthcare REV 5
5764770--1EN
2
Proteus XR/f Generator
GE Healthcare REV 5
5764770--1EN
IMPORTANT PRECAUTIONS LANGUAGE
3
Proteus XR/f Generator
GE Healthcare REV 5
5764770--1EN
4
Proteus XR/f Generator
GE Healthcare REV 5
5764770--1EN
5
Proteus XR/f Generator
GE Healthcare REV 5
5764770--1EN
6
Proteus XR/f Generator
GE Healthcare REV 5
5764770--1EN
7
Proteus XR/f Generator
GE Healthcare REV 5
5764770--1EN
DAMAGE IN TRANSPORTATION All packages should be closely examined at time of delivery. If damage is apparent, have notation “damage in shipment” written on all copies of the freight or express bill before delivery is accepted or “signed for” by a General Electric representative or a hospital receiving agent. Whether noted or concealed, damage MUST be reported to the carrier immediately upon discovery, or in any event, within 14 days after receipt, and the contents and containers held for inspection by the carrier. A transportation company will not pay a claim for damage if an inspection is not requested within this 14 day period. To file a report:
G
Call 1--800--548--3366 and use option 8.
G G
Fill out a report on http://us44hdd21/sctq/InstallFulfill/InstalFulfillment.htm Contact your local service coordinator for more information on this process.
CERTIFIED ELECTRICAL CONTRACTOR STATEMENT All electrical Installations that are preliminary to positioning of the equipment at the site prepared for the equipment shall be performed by licensed electrical contractors. In addition, electrical feeds into the Power Distribution Unit shall be performed by licensed electrical contractors. Other connections between pieces of electrical equipment, calibrations and testing shall be performed by qualified GE Healthcare personnel. The products involved (and the accompanying electrical installations) are highly sophisticated, and special engineering competence is required. In performing all electrical work on these products, GE will use its own specially trained field engineers. All of GE‘s electrical work on these products will comply with the requirements of the applicable electrical codes. The purchaser of GE equipment shall only utilize qualified personnel (i.e., GE‘s field engineers, personnel of third--party service companies with equivalent training, or licensed electricians) to perform electrical servicing on the equipment.
IMPORTANT...X--RAY PROTECTION X--ray equipment if not properly used may cause injury. Accordingly, the instructions herein contained should be thoroughly read and understood by everyone who will use the equipment before you attempt to place this equipment in operation. The General Electric Company, Healthcare Group, will be glad to assist and cooperate in placing this equipment in use. Although this apparatus incorporates a high degree of protection against x--radiation other than the useful beam, no practical design of equipment can provide complete protection. Nor can any practical design compel the operator to take adequate precautions to prevent the possibility of any persons carelessly exposing themselves or others to radiation. It is important that anyone having anything to do with x--radiation be properly trained and fully acquainted with the recommendations of the National Council on Radiation Protection and Measurements as published in NCRP Reports available from NCRP Publications, 7910 Woodmont Avenue, Room 1016, Bethesda, Maryland 20814, and of the International Commission on Radiation Protection, and take adequate steps to protect against injury. The equipment is sold with the understanding that the General Electric Company, Healthcare Group, its agents, and representatives have no responsibility for injury or damage which may result from improper use of the equipment. Various protective materials and devices are available. It is urged that such materials or devices be used.
8
Proteus XR/f Generator
GE Healthcare REV 5
5764770--1EN
OMISSIONS & ERRORS Customers, please contact your GE Sales or Service representatives. GE personnel, please use the GEHC iTrak (issue tracking) process to report all omissions, errors, and defects in this publication.
ENVIRONMENTAL STATEMENT ON THE LIFE CYCLE OF THE EQUIPMENT OR SYSTEM This equipment or system contains environmentally dangerous components and materials (such as PCB‘s, electronic components, used dielectric oil, lead, batteries etc.) which, once the life-cycle of the equipment or system comes to an end, becomes dangerous and need to be considered as harmful waste according to the international, domestic and local regulations. The manufacturer recommends to contact an authorized representative of the manufacturer or an authorized waste management company once the life-cycle of the equipment or system comes to an end to remove this equipment or system.
9
Proteus XR/f Generator
GE Healthcare REV 5
5764770--1EN
10
Proteus XR/f Generator
GE Healthcare REV 5
SM 5764770--1EN
REVISION HISTORY REV
DATE
REASON FOR CHANGE
1
JAN 26, 2017
First edition.
2
JAN 04, 2018
Update of: Extra Fuse 50 Amp. for two--phase Generators, Workstation configuration, AEC Calibration procedure, AEC Checking in Maintenance, Aluminium Filter and tools, FRU part numbers for LV-DRAC Software, FRU part numbers review for Proteus XR/c and XR/f, Schematics
3
FEB 27, 2018
Tools and Test equipment for AEC Calibration, AEC Calibration procedure update, Job Cards chapter.
4
APR 16, 2020
Safety Symbols, removed old information for XR/f AT System, new X-ray Generator Control (PC Interface Box), Generator Cover divided in two parts, replacement of HT Controller Board A3000-33 by A3000--80/81, updated renewal parts and schematics.
5
DEC 07, 2022
SCR--0129019, Update schematic A3240-05
This Document is the English original version, edited and supplied by the manufacturer.
11
Proteus XR/f Generator
GE Healthcare REV 5
SM 5764770--1EN
ADVISORY SYMBOLS The following advisory symbols will be used throughout this manual. Their application and meaning are described below.
DANGERS ADVISE OF CONDITIONS OR SITUATIONS THAT IF NOT HEEDED OR AVOIDED WILL CAUSE SERIOUS PERSONAL INJURY OR DEATH.
ADVISE OF CONDITIONS OR SITUATIONS THAT IF NOT HEEDED OR AVOIDED COULD CAUSE SERIOUS PERSONAL INJURY, OR CATASTROPHIC DAMAGE OF EQUIPMENT OR DATA.
Advise of conditions or situations that if not heeded or avoided could cause personal injury or damage to equipment or data.
Note .
Alert readers to pertinent facts and conditions. Notes represent information that is important to know but which do not necessarily relate to possible injury or damage to equipment.
12
Proteus XR/f Generator
GE Healthcare REV 5
SM 5764770--1EN
SAFETY SYMBOLS The following safety symbols may appear in the equipment. Their meaning are described below.
Caution. Consult accompanying documents.
Safety Symbol. Follow instructions for use, especially those instructions identified with Advisory Symbols to avoid any risk for the Patient or Operator. (Only applies to IEC 60601-1:2005 and IEC 60601-1:2005+AMD1:2012)
Manufacturer.
Date of Manufacture.
Medical Device.
Catalogue Number (Model reference).
Serial Number.
Model Configuration.
Unique Device Identifier.
13
Proteus XR/f Generator
GE Healthcare REV 5
SM 5764770--1EN
General Mandatory action.
Type B applied part.
IPX0
Protection against harmful ingress of water or particulate matter. IP Classification: Ordinary.
Ionizing radiation.
Non-ionizing electromagnetic radiation.
Radiation of Laser apparatus. Do not stare into beam. (Only applicable to equipment with Laser Pointer)
Dangerous voltage.
General warning, caution, risk of danger.
Warning: Ionizing radiation.
14
Proteus XR/f Generator
GE Healthcare REV 5
SM 5764770--1EN
Warning: Non-ionizing radiation.
Warning: Laser beam.
Warning: Electricity.
Warning: Do not place fingers between mobile and fixed parts of the equipment, it may cause serious injuries to patient or operator. As well, make sure the patient extremities are correctly positioned into limit areas during operation, movement of parts may cause serious damages to patient.
Electrostatic sensitive devices.
No pushing.
No sitting.
No stepping on surface.
Do not handle.
15
Proteus XR/f Generator
GE Healthcare REV 5
SM 5764770--1EN
Emergency stop.
“Stand-by” power. (Only applies to IEC 60601-1:2005 and IEC 60601-1:2005+AMD1:2012)
“ON” power.
“OFF” power.
“ON” / “OFF” (push-push). Each position, “ON” or “OFF”, is a stable position.
Alternating current.
Three-phase alternating current.
Three-phase alternating current with neutral conductor.
N
Connection point for the neutral conductor on Permanently Installed equipment.
16
Proteus XR/f Generator
GE Healthcare REV 5
SM 5764770--1EN
Direct current.
Both direct and alternating current.
Protective Earth (Ground).
Earth (Ground).
This symbol according to the European Directive indicates that the Waste of Electrical and Electronic Equipment (WEEE) must not be disposed of as unsorted municipal waste and must be collected separately. Please contact an authorized representative of the manufacturer or an authorized waste management company for information concerning the decommissioning of your equipment.
Li/Pb/Cd/Hg
This separate collection symbol is affixed to a battery or its packing, to advise that the battery must be recycled or disposed of in accordance with local or country laws. The letters below the symbol indicate whether certain elements (Li=Lithium, PB=Lead, CD=Cadmium, Hg=Mercury) are contained in the battery. All batteries removed from the equipment must be properly recycled or disposed. Please contact an authorized representative of the manufacturer or an authorized waste management company for information concerning the decommissioning of your equipment. Pollution Control. (Only applicable to People’s Republic of China (PRC)). This symbol indicates the product contains hazardous materials in excess of the limits established by the Chinese Standards. It must not be disposed of as unsorted municipal waste and must be collected separately. Please contact an authorized representative of the manufacturer or an authorized waste management company for information concerning the decommissioning of your equipment.
17
Proteus XR/f Generator
GE Healthcare REV 5
SM 5764770--1EN
This page intentionally left blank.
18
Proteus XR/f Generator
GE Healthcare REV 5
SM 5764770--1EN
TABLE OF CONTENTS Section
Page
CHAPTER 1 -- SAFETY AND SERVICE...
1-1
1
LOCK-OUT / TAG-OUT (LOTO)...
1-3
1.1
System Power...
1-3
1.2
LOTO Procedure for System Power...
1-4
CONTROL SWITCHES AND BUTTONS...
1-7
2.1
X-Ray Generator Control...
1-7
2.2
Power ON / OFF...
1-8
3
APPLYING SYSTEM POWER...
1-9
4
EQUIPMENT SAFETY -- ELECTROSTATIC DISCHARGE (ESD)...
1-11
4.1
Generating Static...
1-11
4.2
Personal Grounding Methods and Equipment...
1-12
4.3
Grounding the Work Area...
1-13
4.4
Recommended Materials and Equipment...
1-13
CHAPTER 2 - INSTALLATION...
2-1
1
INTRODUCTION...
2-3
1.1
Tools and Test Equipment...
2-3
1.2
Pre-installation Check...
2-4
1.3
General Cautions...
2-4
UNPACKING, CABINET, PC INTERFACE BOX INSTALLATION, AND POWER LINE CONNECTION...
2-7
2.1
2-12
2
2
PC Interface Box Control Panel Installation...
19
Proteus XR/f Generator
GE Healthcare REV 5
SM 5764770--1EN
Section 3
Page CABLE CONNECTIONS...
2-17
3.1
Cable Routing inside Generator Cabinet...
2-17
3.1.1
General Cable Routing...
2-17
3.2
High Voltage Cables Connection...
2-20
3.3
X-ray Tube Connection...
2-22
3.3.1
Stator Cable...
2-22
Interconnection Cables...
2-25
3.4.1
Virtual Console (PC)...
2-26
3.4.2
Door Interlock Signal...
2-26
3.4.3
Warning Light Signal...
2-27
3.4.4
Collimator Lamp and System Locks...
2-27
3.4.5
230 VAC Power Supply for Two External Devices (optional)...
2-28
3.4.6
Ion Chambers...
2-28
FINAL INSTALLATION AND CHECKS...
2-31
4.1
Cable Fastening and Covers...
2-31
SYSTEM INTERCONNECTIONS...
2-33
5.1
System Interconnection Signals...
2-33
5.2
System Interconnection Maps...
2-35
CHAPTER 3 -- CONFIGURATION AND CALIBRATION...
3-1
1
INTRODUCTION...
3-3
1.1
Tools and Test Equipment...
3-4
1.2
Generator Specifications...
3-4
1.2.1
Minimum Current Time Product (mAs)...
3-4
1.2.2
Exposure Accuracy...
3-5
1.2.3
HV Frequency...
3-5
1.2.4
Duty Cycle...
3-5
3.4
4
5
20