Basic Service Manual
246 Pages
Preview
Page 1
GE Healthcare
LOGIQ e/LOGIQ e Vet/LOGIQ i/ Vivid e Basic Service Manual
Part Number: 5370626-100 Revision: 7
GE HEALTHCARE DIRECTION 5370626-100, REVISION 7
LOGIQ E/LOGIQ E VET/LOGIQ I/VIVID E BASIC SERVICE MANUAL
Important Precautions
WARNING (EN)
AVERTISSEMENT (FR)
WARNUNG (DE)
THIS SERVICE MANUAL IS AVAILABLE IN ENGLISH ONLY. • IF A CUSTOMER’S SERVICE PROVIDER REQUIRES A LANGUAGE OTHER THAN ENGLISH, IT IS THE CUSTOMER’S RESPONSIBILITY TO PROVIDE TRANSLATION SERVICES. • DO NOT ATTEMPT TO SERVICE THE EQUIPMENT UNLESS THIS SERVICE MANUAL HAS BEEN CONSULTED AND IS UNDERSTOOD. • FAILURE TO HEED THIS WARNING MAY RESULT IN INJURY TO THE SERVICE PROVIDER, OPERATOR OR PATIENT FROM ELECTRIC SHOCK, MECHANICAL OR OTHER HAZARDS. CE MANUEL DE MAINTENANCE N’EST DISPONIBLE QU’EN ANGLAIS. • SI LE TECHNICIEN DU CLIENT A BESOIN DE CE MANUEL DANS UNE AUTRE LANGUE QUE L’ANGLAIS, C’EST AU CLIENT QU’IL INCOMBE DE LE FAIRE TRADUIRE. • NE PAS TENTER D’INTERVENTION SUR LES é QUIPEMENTS TANT QUE LE MANUEL SERVICE N’A PAS é Té CONSULTé ET COMPRIS. • LE NON-RESPECT DE CET AVERTISSEMENT PEUT ENTRAîNER CHEZ LE TECHNICIEN, L’OPé RATEUR OU LE PATIENT DES BLESSURES DUES à DES DANGERS é LECTRIQUES, Mé CANIQUES OU AUTRES. DIESES KUNDENDIENST-HANDBUCH EXISTIERT NUR IN ENGLISCHER SPRACHE. • FALLS EIN FREMDER KUNDENDIENST EINE ANDERE SPRACHE BENö TIGT, IST ES AUFGABE DES KUNDEN Fü R EINE ENTSPRECHENDE ÜBERSETZUNG ZU SORGEN. • VERSUCHEN SIE NICHT, DAS GERä T ZU REPARIEREN, BEVOR DIESES KUNDENDIENST-HANDBUCH NICHT ZU RATE GEZOGEN UND VERSTANDEN WURDE. • WIRD DIESE WARNUNG NICHT BEACHTET, SO KANN ES ZU VERLETZUNGEN DES KUNDENDIENSTTECHNIKERS, DES BEDIENERS ODER DES PATIENTEN DURCH ELEKTRISCHE SCHLä GE, MECHANISCHE ODER SONSTIGE GEFAHREN KOMMEN.
-
i
GE HEALTHCARE DIRECTION 5370626-100, REVISION 7
HOIATUS (ET)
LOGIQ E/LOGIQ E VET/LOGIQ I/VIVID E BASIC SERVICE MANUAL
KÄESOLEV TEENINDUSJUHEND ON SAADAVAL AINULT INGLISE KEELES. • KUI KLIENDITEENINDUSE OSUTAJA Nõ UAB JUHENDIT INGLISE KEELEST ERINEVAS KEELES, VASTUTAB KLIENT Tõ LKETEENUSE OSUTAMISE EEST. • ä RGE ü RITAGE SEADMEID TEENINDADA ENNE EELNEVALT Kä ESOLEVA TEENINDUSJUHENDIGA TUTVUMIST JA SELLEST ARU SAAMIST. • Kä ESOLEVA HOIATUSE EIRAMINE Võ IB Põ HJUSTADA TEENUSEOSUTAJA, OPERAATORI Võ I PATSIENDI VIGASTAMIST ELEKTRILö ö GI, MEHAANILISE Võ I MUU OHU TAGAJä RJEL.
(FI)
TÄMÄ HUOLTO-OHJE ON SAATAVILLA VAIN ENGLANNIKSI. • JOS ASIAKKAAN PALVELUNTARJOAJA VAATII MUUTA KUIN ENGLANNINKIELISTä MATERIAALIA, TARVITTAVAN Kä ä NNö KSEN HANKKIMINEN ON ASIAKKAAN VASTUULLA. • ä Lä YRITä KORJATA LAITTEISTOA ENNEN KUIN OLET VARMASTI LUKENUT JA YMMä RTä NYT Tä Mä N HUOLTO-OHJEEN. • MIKä LI Tä Tä VAROITUSTA EI NOUDATETA, SEURAUKSENA VOI OLLA PALVELUNTARJOAJAN, LAITTEISTON Kä YTTä Jä N TAI POTILAAN VAHINGOITTUMINEN Sä HKö ISKUN, MEKAANISEN VIAN TAI MUUN VAARATILANTEEN VUOKSI.
ΠΡΟΕΙΔΟΠΟΙΗΣΗ
ΤΟ ΠΑΡΟΝ ΕΓΧΕΙΡΙΔΙΟ ΣΕΡΒΙΣ ΔΙΑΤΙΘΕΤΑΙ ΣΤΑ ΑΓΓΛΙΚΑ ΜΟΝΟ. • ΕΑΝ ΤΟ ΑΤΟΜΟ ΠΑΡΟΧΗΣ ΣΕΡΒΙΣ ΕΝΟΣ ΠΕΛΑΤΗ ΑΠΑΙΤΕΙ ΤΟ ΠΑΡΟΝ ΕΓΧΕΙΡΙΔΙΟ ΣΕ ΓΛΩΣΣΑ ΕΚΤΟΣ ΤΩΝ ΑΓΓΛΙΚΩΝ, ΑΠΟΤΕΛΕΙ ΕΥΘΥΝΗ ΤΟΥ ΠΕΛΑΤΗ ΝΑ ΠΑΡΕΧΕΙ ΥΠΗΡΕΣΙΕΣ ΜΕΤΑΦΡΑΣΗΣ. • ΜΗΝ ΕΠΙΧΕΙΡΗΣΕΤΕ ΤΗΝ ΕΚΤΕΛΕΣΗ ΕΡΓΑΣΙΩΝ ΣΕΡΒΙΣ ΣΤΟΝ ΕΞΟΠΛΙΣΜΟ ΕΚΤΟΣ ΕΑΝ ΕΧΕΤΕ ΣΥΜΒΟΥΛΕΥΤΕΙ ΚΑΙ ΕΧΕΤΕ ΚΑΤΑΝΟΗΣΕΙ ΤΟ ΠΑΡΟΝ ΕΓΧΕΙΡΙΔΙΟ ΣΕΡΒΙΣ. • ΕΑΝ ΔΕ ΛΑΒΕΤΕ ΥΠΟΨΗ ΤΗΝ ΠΡΟΕΙΔΟΠΟΙΗΣΗ ΑΥΤΗ, ΕΝΔΕΧΕΤΑΙ ΝΑ ΠΡΟΚΛΗΘΕΙ ΤΡΑΥΜΑΤΙΣΜΟΣ ΣΤΟ ΑΤΟΜΟ ΠΑΡΟΧΗΣ ΣΕΡΒΙΣ, ΣΤΟ ΧΕΙΡΙΣΤΗ Ή ΣΤΟΝ ΑΣΘΕΝΗ ΑΠΟ ΗΛΕΚΤΡΟΠΛΗΞΙΑ, ΜΗΧΑΝΙΚΟΥΣ Ή ΑΛΛΟΥΣ ΚΙΝΔΥΝΟΥΣ.
VAROITUS
(EL)
FIGYELMEZTETÉS (HU)
EZEN KARBANTARTÁSI KÉZIKÖNYV KIZÁRÓLAG ANGOL NYELVEN ÉRHETŐ EL. • HA A VEVŐ SZOLGÁLTATÓJA ANGOLTÓL ELTÉRŐ NYELVRE TART IGÉNYT, AKKOR A VEVŐ FELELŐSSÉGE A FORDÍTÁS ELKÉSZÍTTETÉSE. • NE PRÓBÁLJA ELKEZDENI HASZNÁLNI A BERENDEZÉST, AMÍG A KARBANTARTÁSI KÉZIKÖNYVBEN LEÍRTAKAT NEM ÉRTELMEZTÉK. • EZEN FIGYELMEZTETÉS FIGYELMEN KÍVÜL HAGYÁSA A SZOLGÁLTATÓ, MŰKÖDTETŐ VAGY A BETEG ÁRAMÜTÉS, MECHANIKAI VAGY EGYÉB VESZÉLYHELYZET MIATTI SÉRÜLÉSÉT EREDMÉNYEZHETI.
-
iii
GE HEALTHCARE DIRECTION 5370626-100, REVISION 7
LOGIQ E/LOGIQ E VET/LOGIQ I/VIVID E BASIC SERVICE MANUAL
BRĪDINĀJUMS (LV)
šĪ APKALPES ROKASGRĀMATA IR PIEEJAMA TIKAI ANGĻU VALODĀ. • JA KLIENTA APKALPES SNIEDZĒJAM NEPIECIEŠAMA INFORMĀCIJA CITĀ VALODĀ, NEVIS ANGĻU, KLIENTA PIENĀKUMS IR NODROŠINĀT TULKOŠANU. • NEVEICIET APRĪKOJUMA APKALPI BEZ APKALPES ROKASGRĀMATAS IZLASĪŠANAS UN SAPRAŠANAS. • ŠĪ BRĪDINĀJUMA NEIEVĒROŠANA VAR RADĪT ELEKTRISKĀS STRĀVAS TRIECIENA, MEHĀNISKU VAI CITU RISKU IZRAISĪTU TRAUMU APKALPES SNIEDZĒJAM, OPERATORAM VAI PACIENTAM.
ĮSPĖJIMAS (LT)
ŠIS EKSPLOATAVIMO VADOVAS YRA IŠLEISTAS TIK ANGLŲ KALBA. • JEI KLIENTO PASLAUGŲ TEIKĖJUI REIKIA VADOVO KITA KALBA – NE ANGLŲ, VERTIMU PASIRŪPINTI TURI KLIENTAS. • NEMĖGINKITE ATLIKTI ĮRANGOS TECHNINĖS PRIEŽIŪROS DARBŲ, NEBENT VADOVAUTUMĖTĖS ŠIUO EKSPLOATAVIMO VADOVU IR JĮ SUPRASTUMĖTE • NEPAISANT ŠIO PERSPĖJIMO, PASLAUGŲ TEIKĖJAS, OPERATORIUS AR PACIENTAS GALI BŪTI SUŽEISTAS DĖL ELEKTROS SMŪGIO, MECHANINIŲ AR KITŲ PAVOJŲ.
ADVARSEL (NO)
DENNE SERVICEHÅNDBOKEN FINNES BARE PÅ ENGELSK. • HVIS KUNDENS SERVICELEVERANDØR TRENGER ET ANNET SPRÅK, ER DET KUNDENS ANSVAR Å SØRGE FOR OVERSETTELSE. • IKKE FORSØK Å REPARERE UTSTYRET UTEN AT DENNE SERVICEHÅNDBOKEN ER LEST OG FORSTÅTT. • MANGLENDE HENSYN TIL DENNE ADVARSELEN KAN FØRE TIL AT SERVICELEVERANDØREN, OPERATØREN ELLER PASIENTEN SKADES PÅ GRUNN AV ELEKTRISK STØT, MEKANISKE ELLER ANDRE FARER.
OSTRZEŻENIE (PL)
NINIEJSZY PODRĘCZNIK SERWISOWY DOSTĘPNY JEST JEDYNIE W JĘZYKU ANGIELSKIM. • JEś LI FIRMA ś WIADCZĄCA KLIENTOWI USłUGI SERWISOWE WYMAGA UDOSTę PNIENIA PODRę CZNIKA W Ję ZYKU INNYM NIŻ ANGIELSKI, OBOWIĄZEK ZAPEWNIENIA STOSOWNEGO TłUMACZENIA SPOCZYWA NA KLIENCIE. • NIE PRó BOWAć SERWISOWAć NINIEJSZEGO SPRZę TU BEZ UPRZEDNIEGO ZAPOZNANIA SIę Z PODRę CZNIKIEM SERWISOWYM. • NIEZASTOSOWANIE SIę DO TEGO OSTRZEŻENIA MOżE GROZIć OBRAŻENIAMI CIAłA SERWISANTA, OPERATORA LUB PACJENTA W WYNIKU PORAŻENIA PRĄDEM, URAZU MECHANICZNEGO LUB INNEGO RODZAJU ZAGROŻEń .
-
v
GE HEALTHCARE DIRECTION 5370626-100, REVISION 7
DİKKAT (TR)
LOGIQ E/LOGIQ E VET/LOGIQ I/VIVID E BASIC SERVICE MANUAL
BU SERVİS KILAVUZU YALNIZCA İNGİLİZCE OLARAK SAĞLANMIŞTIR. • EĞER MÜŞTERİ TEKNİSYENİ KILAVUZUN İNGİLİZCE DIŞINDAKİ BİR DİLDE OLMASINI İSTERSE, KILAVUZU TERCÜME ETTİRMEK MÜŞTERİNİN SORUMLULUĞUNDADIR. • SERVİS KILAVUZUNU OKUYUP ANLAMADAN EKİPMANLARA MÜDAHALE ETMEYİNİZ. • BU UYARININ GÖZ ARDI EDİLMESİ, ELEKTRİK ÇARPMASI YA DA MEKANİK VEYA DİĞER TÜRDEN KAZALAR SONUCUNDA TEKNİSYENİN, OPERATÖRÜN YA DA HASTANIN YARALANMASINA YOL AÇABİLİR.
(JA)
Traditional Chinese
viii
-
GE HEALTHCARE DIRECTION 5370626-100, REVISION 7
LOGIQ E/LOGIQ E VET/LOGIQ I/VIVID E BASIC SERVICE MANUAL
DAMAGE IN TRANSPORTATION All packages should be closely examined at time of delivery. If damage is apparent write “Damage In Shipment” on ALL copies of the freight or express bill BEFORE delivery is accepted or “signed for” by a GE representative or hospital receiving agent. Whether noted or concealed, damage MUST be reported to the carrier immediately upon discovery, or in any event, within 14 days after receipt, and the contents and containers held for inspection by the carrier. A transportation company will not pay a claim for damage if an inspection is not requested within this 14 day period.
CERTIFIED ELECTRICAL CONTRACTOR STATEMENT - FOR USA ONLY All electrical Installations that are preliminary to positioning of the equipment at the site prepared for the equipment shall be performed by licensed electrical contractors. Other connections between pieces of electrical equipment, calibrations and testing shall be performed by qualified GE Healthcare personnel. In performing all electrical work on these products, GE will use its own specially trained field engineers. All of GE’s electrical work on these products will comply with the requirements of the applicable electrical codes. The purchaser of GE equipment shall only utilize qualified personnel (i.e., GE’s field engineers, personnel of third-party service companies with equivalent training, or licensed electricians) to perform electrical servicing on the equipment.
OMISSIONS & ERRORS If there are any omissions, errors or suggestions for improving this documentation, please contact the GE Healthcare Global Documentation Group with specific information listing the system type, manual title, part number, revision number, page number and suggestion details. Mail the information to: Service Documentation, GE Medical Systems (China) Co., Ltd. No.19 Changjiang Road WuXi National Hi-Tech Development Zone Jiangsu, P.R China 214028 TEL: +86 510 85225888; FAX: +86 510 85226688 GE Healthcare employees should contact the product's Lead Service Integrator (LSI) to report service documentation issues. DO NOT use TrackWise for this purpose. The LSI will then use the internal problem reporting tool to communicate these issues to the writer.
SERVICE SAFETY CONSIDERATIONS DANGER
DANGEROUS VOLTAGES, CAPABLE OF CAUSING DEATH, ARE PRESENT IN THIS EQUIPMENT. USE EXTREME CAUTION WHEN HANDLING, TESTING AND ADJUSTING.
WARNING Use all Personal Protection Equipment (PPE) such as gloves, safety shoes, safety
glasses, and kneeling pad, to reduce the risk of injury. For a complete review of all safety requirements, see the Chapter 1, Safety Considerations section in the Service Manual.
x
-
GE HEALTHCARE DIRECTION 5370626-100, REVISION 7
LOGIQ E/LOGIQ E VET/LOGIQ I/VIVID E BASIC SERVICE MANUAL
LEGAL NOTES The contents of this publication may not be copied or duplicated in any form, in whole or in part, without prior written permission of GE Healthcare. GE Healthcare may revise this publication from time to time without written notice.
TRADEMARKS All products and their name brands are trademarks of their respective holders.
COPYRIGHTS All Material Copyright© 2004 to 2011 by General Electric Company Inc. All Rights Reserved.
-
xi
GE HEALTHCARE DIRECTION 5370626-100, REVISION 7
LOGIQ E/LOGIQ E VET/LOGIQ I/VIVID E BASIC SERVICE MANUAL
Revision History Revision
Date
Reason for change
1
23, Qct. 2009
Initial Release
2
13, May 2010
Update for Software update and adding new probes
3
29, June 2010
Update to add Isolation Cart enhanced Version
4
30, November 2010
5
25, April 2011
Add Vivid e R6.x.x
6
25, Sep 2011
Update for LOGIQ e Vet R6.x.x
7
5, Oct 2011
Update for LOGIQ e R7.x.x
Update LOGIQ e Spare Parts and add USA CKD address
List of Effected Pages (LOEP)
xii
Pages
Revision
Pages
Revision
Pages
Revision
Title Page
7
3-1 to 3-32
7
8-1 to 8-10
7
Warnings i to -xii
7
4-1 to 4-38
7
9-1 to 9-32
7
TOC
7
5-1 to 5-20
7
10-1 to 10-21
7
1-1 to 1-20
7
6-1 to 6-2
7
Index
7
2-1 to 2-10
7
7-1 to 7-28
7
Back Cover
N/A
-
GE HEALTHCARE DIRECTION 5370626-100, REVISION 7
LOGIQ E/LOGIQ E VET/LOGIQ I/VIVID E BASIC SERVICE MANUAL
Table of Contents CHAPTER 1 Introduction Overview... 1 - 1 Purpose of Chapter 1... 1 - 1 Chapter Contents... 1 - 1 Purpose of Service Manual... 1 - 1 Typical Users of the Basic Service Manual... 1 - 2 LOGIQ e/LOGIQ e Vet/LOGIQ i/Vivid e Models Covered by this Manual . . 1 - 3 Purpose of Operator Manual(s)... 1 - 5 Important Conventions... 1 - 5 Conventions Used in Book... 1 - 5 Standard Hazard Icons... 1 - 6 Product Icons... 1 - 7 Safety Considerations... 1 - 11 Introduction... 1 - 11 Human Safety... 1 - 11 Mechanical Safety... 1 - 11 Electrical Safety... 1 - 12 Label Location... 1 - 13 Battery Safety... 1 - 14 Dangerous Procedure Warnings... 1 - 16 Lockout/Tagout (LOTO) requirements... 1 - 16 Returning/Shipping Probes and Repair Parts... 1 - 17 EMC, EMI, and ESD... 1 - 18 Electromagnetic Compatibility (EMC)... 1 - 18 CE Compliance... 1 - 18 Electrostatic Discharge (ESD) Prevention... 1 - 18 Customer Assistance... 1 - 19 Contact Information... 1 - 19 System Manufacturer... 1 - 20 Factory Sites... 1 - 20
1
Table of Contents
GE HEALTHCARE DIRECTION 5370626-100, REVISION 7
LOGIQ E/LOGIQ E VET/LOGIQ I/VIVID E BASIC SERVICE MANUAL
CHAPTER 2 Site preparations Overview... 2 - 1 Purpose of this chapter 2... 2 - 1 Chapter Contents... 2 - 1 General Console Requirements... 2 - 2 Console Environmental Requirements... 2 - 2 Electrical Requirements... 2 - 2 EMI Limitations... 2 - 4 Scan Probe Environmental Requirements... 2 - 5 Facility Needs... 2 - 6 Recommended Ultrasound Room Layout... 2 - 6 Required Features... 2 - 7 Desirable Features... 2 - 7 Networking Pre-installation Requirements... 2 - 9
Table of Contents
2
GE HEALTHCARE DIRECTION 5370626-100, REVISION 7
LOGIQ E/LOGIQ E VET/LOGIQ I/VIVID E BASIC SERVICE MANUAL
CHAPTER 3 System Setup Overview... 3 - 1 Purpose of Chapter 3... 3 - 1 Average Installation Time... 3 - 2 Installation Warnings... 3 - 3 Safety Reminders... 3 - 3 Receiving and Unpacking the Equipment... 3 - 4 Moving into Position... 3 - 7 Packing the Equipment... 3 - 7 Preparing for Installation... 3 - 8 Verify Customer Order... 3 - 8 Physical Inspection... 3 - 8 EMI Protection... 3 - 8 Completing the Installation... 3 - 9 Power On / Boot Up... 3 - 9 Power Off/ Shutdown... 3 - 10 Transducer Connection... 3 - 11 System Configuration... 3 - 12 System Specifications... 3 - 12 Electrical Specifications... 3 - 12 Approved peripherals... 3 - 13 Connecting Cables... 3 - 14 Peripherals/Accessories Connector Panel... 3 - 14 Available Probes... 3 - 25 Software/Option Configuration... 3 - 27 Connectivity Installation Worksheet... 3 - 28 Loading Base Image Software... 3 - 29 Software Version check out... 3 - 30 Functional Check-out... 3 - 30 Paperwork... 3 - 31 Product Locator Installation... 3 - 31 User Manual(s)... 3 - 31 Table of Contents
3
GE HEALTHCARE DIRECTION 5370626-100, REVISION 7
LOGIQ E/LOGIQ E VET/LOGIQ I/VIVID E BASIC SERVICE MANUAL
CHAPTER 4 Functional Checks Overview... 4 - 1 Purpose for Chapter 4... 4 - 1 Required Equipment... 4 - 1 General Procedure... 4 - 2 Power On/Boot Up... 4 - 2 Power Off/ Shutdown... 4 - 3 Archiving and Loading Presets... 4 - 5 Adjusting the Display Monitor... 4 - 6 Lockout/Tagout (LOTO) requirements... 4 - 6 System Features... 4 - 7 B Mode Checks... 4 - 10 M Mode Controls... 4 - 13 Color Flow Mode Checks... 4 - 16 Doppler Mode Checks... 4 - 20 CWD Functional Check... 4 - 24 Basic Measurements... 4 - 25 Probe/Connectors Usage... 4 - 25 Using Cine... 4 - 26 Image Management (QG)... 4 - 27 Backup and Restore Database, Preset Configurations and Images... 4 - 28 Software Configuration Checks... 4 - 37 Peripheral Checks... 4 - 37
Table of Contents
4
GE HEALTHCARE DIRECTION 5370626-100, REVISION 7
LOGIQ E/LOGIQ E VET/LOGIQ I/VIVID E BASIC SERVICE MANUAL
CHAPTER 5 Components and Functions (Theory) Overview... 5 - 1 Block Diagrams and Theory... 5 - 2 Block Diagram... 5 - 2 General Information... 5 - 3 External I/O... 5 - 4 Peripherals... 5 - 4 Wiring... 5 - 5 Power Diagrams... 5 - 6 Overview... 5 - 6 AC Power... 5 - 6 Battery charging... 5 - 7 Air Flow Distribution... 5 - 8 Fans... 5 - 9 Common Service Platform... 5 - 10 Introduction... 5 - 10 Global Service User Interface (GSUI)... 5 - 10 Service Home Page... 5 - 12 Error Logs Tab... 5 - 13 Diagnostics... 5 - 17 Image Quality... 5 - 18 Calibration... 5 - 18 Configuration... 5 - 19 Utilities... 5 - 19 Replacement... 5 - 20 PM... 5 - 20
Table of Contents
5
GE HEALTHCARE DIRECTION 5370626-100, REVISION 7
LOGIQ E/LOGIQ E VET/LOGIQ I/VIVID E BASIC SERVICE MANUAL
CHAPTER 6 Service Adjustments Overview... 6 - 1 Purpose of this chapter 6... 6 - 1 Monitor Adjustments... 6 - 2 Adjustments Procedures... 6 - 2
Table of Contents
6
GE HEALTHCARE DIRECTION 5370626-100, REVISION 7
LOGIQ E/LOGIQ E VET/LOGIQ I/VIVID E BASIC SERVICE MANUAL
CHAPTER 7 Diagnostics/Troubleshooting Overview... 7 - 1 Purpose of Chapter 7... 7 - 1 Gathering Trouble Data... 7 - 2 Overview... 7 - 2 Collect Vital System Information... 7 - 2 Collect a Trouble Image with Logs... 7 - 3 USB Quick Save... 7 - 4 Overview... 7 - 4 Check and Record the P3 Key Function... 7 - 4 Setting the P3 Key to USB Quick Save... 7 - 5 Screen Captures... 7 - 6 Check and Record the P1 Key Function... 7 - 6 Setting the P1 Key to Screen Capture... 7 - 6 Capturing a Screen... 7 - 6 Reset the P1 Key to Customer’s Functionality... 7 - 8 Global Service User Interface (GSUI)... 7 - 9 Enter global service user interface... 7 - 9 Active Diagnostic Function... 7 - 10 Control Frame... 7 - 10 Common Diagnostics... 7 - 12 Utilities... 7 - 12 PC Diagnostics (Non-Interactive Tests)... 7 - 13 PC Diagnostics (Interactive Tests)... 7 - 14 Restart the system after diagnostics... 7 - 14 Network and Insite II Configuration... 7 - 15 Network Configuration... 7 - 15 Insite II Configuration... 7 - 19 Insite II Configuration (For LOGIQ e R6.x.x)... 7 - 24
Table of Contents
7
GE HEALTHCARE DIRECTION 5370626-100, REVISION 7
LOGIQ E/LOGIQ E VET/LOGIQ I/VIVID E BASIC SERVICE MANUAL
CHAPTER 8 Replacement Procedures Overview... 8 - 1 Purpose of Chapter 8... 8 - 1 Disassembly/Re-assembly of LOGIQ e/LOGIQ e Vet/LOGIQ i/Vivid e... 8 - 1 Warning and Caution... 8 - 1 Handle Assy (FRU No. 313)... 8 - 2 Loading Base Image Software... 8 - 4 Checks after FRU replacement (Debrief Guidelines)... 8 - 9
8
Table of Contents
GE HEALTHCARE DIRECTION 5370626-100, REVISION 7
LOGIQ E/LOGIQ E VET/LOGIQ I/VIVID E BASIC SERVICE MANUAL
CHAPTER 9 Renewal Parts Overview... 9 - 1 Purpose of Chapter 9... 9 - 1 List of Abbreviations... 9 - 1 Renewal Parts Lists... 9 - 2 Equipment Models Covered in this Chapter... 9 - 2 Operator Console Assy... 9 - 3 LCD Assy... 9 - 4 Keyboard Assy... 9 - 6 Bottom Assy... 9 - 9 Cables... 9 - 14 Isolation Cart Components... 9 - 15 Isolation Cart Enhanced Version Components... 9 - 17 Accessories and Kits... 9 - 19 Manuals... 9 - 24 Probe... 9 - 29
Table of Contents
9
GE HEALTHCARE DIRECTION 5370626-100, REVISION 7
LOGIQ E/LOGIQ E VET/LOGIQ I/VIVID E BASIC SERVICE MANUAL
CHAPTER 10 Care & Maintenance Overview... 10 - 1 Periodic Maintenance Inspections... 10 - 1 Purpose of Chapter 10... 10 - 1 Why do Maintenance... 10 - 2 Keeping Records... 10 - 2 Quality Assurance... 10 - 2 Maintenance Task Schedule... 10 - 2 How often should care & maintenance tasks be performed?... 10 - 2 Tools Required... 10 - 4 Special Tools, Supplies and Equipment... 10 - 4 System Maintenance... 10 - 5 Preliminary Checks... 10 - 5 Functional Checks (See Also Chapter 4)... 10 - 6 Input Power... 10 - 7 Cleaning... 10 - 7 Physical Inspection... 10 - 8 Optional Diagnostic Checks... 10 - 9 Probe Maintenance... 10 - 9 Battery Performance Maintenance... 10 - 10 Electrical Safety Tests... 10 - 11 Safety Test Overview... 10 - 11 GEMS Leakage Current Limits... 10 - 12 Outlet Test - Wiring Arrangement... 10 - 13 Chassis Leakage Current Test... 10 - 14 Probe Leakage Current Test... 10 - 16 When There's Too Much Leakage Current... 10 - 19
10
Table of Contents
GE HEALTHCARE DIRECTION 5370626-100, REVISION 7
LOGIQ E/LOGIQ E VET/LOGIQ I/VIVID E BASIC SERVICE MANUAL
Chapter 1 Introduction Section 1-1 Overview 1-1-1
Purpose of Chapter 1 This chapter describes important issues related to safely servicing this ultrasound machine. The service provider must read and understand all the information presented here before installing or servicing a unit.
1-1-2
Chapter Contents Table 1-1 Contents in Chapter 1 Section
1-1-3
Description
Page Number
1-1
Overview
1-1
1-2
Important Conventions
1-6
1-3
Safety Considerations
1-12
1-4
EMC, EMI, and ESD
1-16
1-5
Customer Assistance
1-17
Purpose of Service Manual This Service Manual provides service information for the LOGIQ e/LOGIQ e Vet/LOGIQ i/Vivid e Ultrasound Scanning System. It contains the following chapters: 1.) Chapter 1 - Introduction: Contains a content summary and warnings. 2.) Chapter 2 - Site preparations: Contains pre-installation requirements for the LOGIQ e/LOGIQ e Vet/LOGIQ i/Vivid e . 3.) Chapter 3 - System Setup: Contains installation procedures. 4.) Chapter 4 - Functional Checks: Contains functional checks that are recommended as part of the installation, or as required during servicing and periodic maintenance. 5.) Chapter 5 - Components and Functions (Theory): Contains block diagrams and functional explanations of the electronics. 6.) Chapter 6 - Service Adjustments: Contains instructions on how to make available adjustments to the LOGIQ e/LOGIQ e Vet/LOGIQ i/Vivid e . 7.) Chapter 7 - Diagnostics/Troubleshooting: Provides procedures for running diagnostic or related routines for the LOGIQ e/LOGIQ e Vet/LOGIQ i/Vivid e . 8.) Chapter 8 - Replacement Procedures: Provides disassembly procedures and reassembly procedures for all changeable Field Replaceable Units (FRU). 9.) Chapter 9 - Renewal Parts: Contains a complete list of field replaceable parts for the LOGIQ e/ LOGIQ e Vet/LOGIQ i/Vivid e . 10.)Chapter 10 - Care & Maintenance: Provides periodic maintenance procedures for the LOGIQ e/ LOGIQ e Vet/LOGIQ i/Vivid e . Chapter 1 Introduction
1-1
GE HEALTHCARE DIRECTION 5370626-100, REVISION 7
1-1-4
1-2
LOGIQ E/LOGIQ E VET/LOGIQ I/VIVID E BASIC SERVICE MANUAL
Typical Users of the Basic Service Manual •
Service Personnel (installation, maintenance, etc.).
•
Hospital’s Service Personnel
•
Contractors (Some parts of Chapter 2 - Site Preparations)
Section 1-1 - Overview