Service Manual
532 Pages
Preview
Page 1
GE Healthcare
Technical Publication Direction 5394141 Revision 5 GE Healthcare LOGIQ™P5 Service Manual
Operating Documentation
Copyright© 2011, 2014 by General Electric Co.
GE HEALTHCARE DIRECTION 5394141, REVISION 5
LOGIQ™ P5 SEVICE MANUAL
Important Precautions
WARNING (EN)
AVERTISSEMENT (FR)
WARNUNG (DE)
• THIS SERVICE MANUAL IS AVAILABLE IN ENGLISH ONLY. • IF A CUSTOMER’S SERVICE PROVIDER REQUIRES A LANGUAGE OTHER THAN ENGLISH, IT IS THE CUSTOMER’S RESPONSIBILITY TO PROVIDE TRANSLATION SERVICES. • DO NOT ATTEMPT TO SERVICE THE EQUIPMENT UNLESS THIS SERVICE MANUAL HAS BEEN CONSULTED AND IS UNDERSTOOD. • FAILURE TO HEED THIS WARNING MAY RESULT IN INJURY TO THE SERVICE PROVIDER, OPERATOR OR PATIENT FROM ELECTRIC SHOCK, MECHANICAL OR OTHER HAZARDS. • CE MANUEL DE MAINTENANCE N’EST DISPONIBLE QU’EN ANGLAIS. • SI LE TECHNICIEN DU CLIENT A BESOIN DE CE MANUEL DANS UNE AUTRE LANGUE QUE L’ANGLAIS, C’EST AU CLIENT QU’IL INCOMBE DE LE FAIRE TRADUIRE. • NE PAS TENTER D’INTERVENTION SUR LES é QUIPEMENTS TANT QUE LE MANUEL SERVICE N’A PAS é Té CONSULTé ET COMPRIS. • LE NON-RESPECT DE CET AVERTISSEMENT PEUT ENTRAîNER CHEZ LE TECHNICIEN, L’OPé RATEUR OU LE PATIENT DES BLESSURES DUES à DES DANGERS é LECTRIQUES, Mé CANIQUES OU AUTRES. • DIESES KUNDENDIENST-HANDBUCH EXISTIERT NUR IN ENGLISCHER SPRACHE. • FALLS EIN FREMDER KUNDENDIENST EINE ANDERE SPRACHE BENö TIGT, IST ES AUFGABE DES KUNDEN Fü R EINE ENTSPRECHENDE ÜBERSETZUNG ZU SORGEN. • VERSUCHEN SIE NICHT, DAS GERä T ZU REPARIEREN, BEVOR DIESES KUNDENDIENST-HANDBUCH NICHT ZU RATE GEZOGEN UND VERSTANDEN WURDE. • WIRD DIESE WARNUNG NICHT BEACHTET, SO KANN ES ZU VERLETZUNGEN DES KUNDENDIENSTTECHNIKERS, DES BEDIENERS ODER DES PATIENTEN DURCH ELEKTRISCHE SCHLä GE, MECHANISCHE ODER SONSTIGE GEFAHREN KOMMEN.
-
i-3
GE HEALTHCARE DIRECTION 5394141, REVISION 5
AVISO (ES)
ATENÇÃO (PT)
AVVERTENZA (IT)
HOIATUS (ET)
i-4
LOGIQ™ P5 SEVICE MANUAL
• ESTE MANUAL DE SERVICIO Só LO EXISTE EN INGLé S. • SI ALGú N PROVEEDOR DE SERVICIOS AJENO A GEHC SOLICITA UN IDIOMA QUE NO SEA EL INGLé S, ES RESPONSABILIDAD DEL CLIENTE OFRECER UN SERVICIO DE TRADUCCIó N. • NO SE DEBERá DAR SERVICIO Té CNICO AL EQUIPO, SIN HABER CONSULTADO Y COMPRENDIDO ESTE MANUAL DE SERVICIO. • LA NO OBSERVANCIA DEL PRESENTE AVISO PUEDE DAR LUGAR A QUE EL PROVEEDOR DE SERVICIOS, EL OPERADOR O EL PACIENTE SUFRAN LESIONES PROVOCADAS POR CAUSAS ELé CTRICAS, MECá NICAS O DE OTRA NATURALEZA. • ESTE MANUAL DE ASSISTê NCIA Té CNICA Só SE ENCONTRA DISPONíVEL EM INGLê S. • SE QUALQUER OUTRO SERVIç O DE ASSISTê NCIA Té CNICA, QUE Nã O A GEHC, SOLICITAR ESTES MANUAIS NOUTRO IDIOMA, é DA RESPONSABILIDADE DO CLIENTE FORNECER OS SERVIç OS DE TRADUç ã O. • Nã O TENTE REPARAR O EQUIPAMENTO SEM TER CONSULTADO E COMPREENDIDO ESTE MANUAL DE ASSISTê NCIA Té CNICA. • O Nã O CUMPRIMENTO DESTE AVISO PODE POR EM PERIGO A SEGURANç A DO Té CNICO, OPERADOR OU PACIENTE DEVIDO A‘ CHOQUES ELé TRICOS, MECâ NICOS OU OUTROS. • IL PRESENTE MANUALE DI MANUTENZIONE è DISPONIBILE SOLTANTO IN INGLESE. • SE UN ADDETTO ALLA MANUTENZIONE ESTERNO ALLA GEHC RICHIEDE IL MANUALE IN UNA LINGUA DIVERSA, IL CLIENTE è TENUTO A PROVVEDERE DIRETTAMENTE ALLA TRADUZIONE. • SI PROCEDA ALLA MANUTENZIONE DELL’APPARECCHIATURA SOLO DOPO AVER CONSULTATO IL PRESENTE MANUALE ED AVERNE COMPRESO IL CONTENUTO. • NON TENERE CONTO DELLA PRESENTE AVVERTENZA POTREBBE FAR COMPIERE OPERAZIONI DA CUI DERIVINO LESIONI ALL’ADDETTO ALLA MANUTENZIONE, ALL’UTILIZZATORE ED AL PAZIENTE PER FOLGORAZIONE ELETTRICA, PER URTI MECCANICI OD ALTRI RISCHI. • KÄESOLEV TEENINDUSJUHEND ON SAADAVAL AINULT INGLISE KEELES. • KUI KLIENDITEENINDUSE OSUTAJA Nõ UAB JUHENDIT INGLISE KEELEST ERINEVAS KEELES, VASTUTAB KLIENT Tõ LKETEENUSE OSUTAMISE EEST. • ä RGE ü RITAGE SEADMEID TEENINDADA ENNE EELNEVALT Kä ESOLEVA TEENINDUSJUHENDIGA TUTVUMIST JA SELLEST ARU SAAMIST. • Kä ESOLEVA HOIATUSE EIRAMINE Võ IB Põ HJUSTADA TEENUSEOSUTAJA, OPERAATORI Võ I PATSIENDI VIGASTAMIST ELEKTRILö ö GI, MEHAANILISE Võ I MUU OHU TAGAJä RJEL.
-
GE HEALTHCARE DIRECTION 5394141, REVISION 5
VAROITUS (FI)
ΠΡΟΕΙ∆ΟΠΟΙΗΣΗ
(EL)
FIGYELMEZTETÉS (HU)
VIÐVÖRUN (IS)
LOGIQ™ P5 SEVICE MANUAL
• TÄMÄ HUOLTO-OHJE ON SAATAVILLA VAIN ENGLANNIKSI. • JOS ASIAKKAAN PALVELUNTARJOAJA VAATII MUUTA KUIN ENGLANNINKIELISTä MATERIAALIA, TARVITTAVAN Kä ä NNö KSEN HANKKIMINEN ON ASIAKKAAN VASTUULLA. • ä Lä YRITä KORJATA LAITTEISTOA ENNEN KUIN OLET VARMASTI LUKENUT JA YMMä RTä NYT Tä Mä N HUOLTO-OHJEEN. • MIKä LI Tä Tä VAROITUSTA EI NOUDATETA, SEURAUKSENA VOI OLLA PALVELUNTARJOAJAN, LAITTEISTON Kä YTTä Jä N TAI POTILAAN VAHINGOITTUMINEN Sä HKö ISKUN, MEKAANISEN VIAN TAI MUUN VAARATILANTEEN VUOKSI. • ΤΟ ΠΑΡΟΝ ΕΓΧΕΙΡΙ∆ΙΟ ΣΕΡΒΙΣ ∆ΙΑΤΙΘΕΤΑΙ ΣΤΑ ΑΓΓΛΙΚΑ ΜΟΝΟ. • ΕΑΝ ΤΟ ΑΤΟΜΟ ΠΑΡΟΧΗΣ ΣΕΡΒΙΣ ΕΝΟΣ ΠΕΛΑΤΗ ΑΠΑΙΤΕΙ ΤΟ ΠΑΡΟΝ ΕΓΧΕΙΡΙ∆ΙΟ ΣΕ ΓΛΩΣΣΑ ΕΚΤΟΣ ΤΩΝ ΑΓΓΛΙΚΩΝ, ΑΠΟΤΕΛΕΙ ΕΥΘΥΝΗ ΤΟΥ ΠΕΛΑΤΗ ΝΑ ΠΑΡΕΧΕΙ ΥΠΗΡΕΣΙΕΣ ΜΕΤΑΦΡΑΣΗΣ. • ΜΗΝ ΕΠΙΧΕΙΡΗΣΕΤΕ ΤΗΝ ΕΚΤΕΛΕΣΗ ΕΡΓΑΣΙΩΝ ΣΕΡΒΙΣ ΣΤΟΝ ΕΞΟΠΛΙΣΜΟ ΕΚΤΟΣ ΕΑΝ ΕΧΕΤΕ ΣΥΜΒΟΥΛΕΥΤΕΙ ΚΑΙ ΕΧΕΤΕ ΚΑΤΑΝΟΗΣΕΙ ΤΟ ΠΑΡΟΝ ΕΓΧΕΙΡΙ∆ΙΟ ΣΕΡΒΙΣ. • ΕΑΝ ∆Ε ΛΑΒΕΤΕ ΥΠΟΨΗ ΤΗΝ ΠΡΟΕΙ∆ΟΠΟΙΗΣΗ ΑΥΤΗ, ΕΝ∆ΕΧΕΤΑΙ ΝΑ ΠΡΟΚΛΗΘΕΙ ΤΡΑΥΜΑΤΙΣΜΟΣ ΣΤΟ ΑΤΟΜΟ ΠΑΡΟΧΗΣ ΣΕΡΒΙΣ, ΣΤΟ ΧΕΙΡΙΣΤΗ Ή ΣΤΟΝ ΑΣΘΕΝΗ ΑΠΟ ΗΛΕΚΤΡΟΠΛΗΞΙΑ, ΜΗΧΑΝΙΚΟΥΣ Ή ΑΛΛΟΥΣ ΚΙΝ∆ΥΝΟΥΣ. • EZEN KARBANTARTÁSI KÉZIKÖNYV KIZÁRÓLAG ANGOL NYELVEN ÉRHETŐ EL. • HA A VEVŐ SZOLGÁLTATÓJA ANGOLTÓL ELTÉRŐ NYELVRE TART IGÉNYT, AKKOR A VEVŐ FELELŐSSÉGE A FORDÍTÁS ELKÉSZÍTTETÉSE. • NE PRÓBÁLJA ELKEZDENI HASZNÁLNI A BERENDEZÉST, AMÍG A KARBANTARTÁSI KÉZIKÖNYVBEN LEÍRTAKAT NEM ÉRTELMEZTÉK. • EZEN FIGYELMEZTETÉS FIGYELMEN KÍVÜL HAGYÁSA A SZOLGÁLTATÓ, MŰKÖDTETŐ VAGY A BETEG ÁRAMÜTÉS, MECHANIKAI VAGY EGYÉB VESZÉLYHELYZET MIATTI SÉRÜLÉSÉT EREDMÉNYEZHETI. • ÞESSI ÞJÓNUSTUHANDBÓK ER EINGÖNGU FÁANLEG Á ENSKU. • EF ÞJÓNUSTUAÐILI VIÐSKIPTAMANNS ÞARFNAST ANNARS TUNGUMÁLS EN ENSKU, ER ÞAÐ Á ÁBYRGÐ VIÐSKIPTAMANNS AÐ ÚTVEGA ÞÝÐINGU. • REYNIÐ EKKI AÐ ÞJÓNUSTA TÆKIÐ NEMA EFTIR AÐ HAFA SKOÐAÐ OG SKILIÐ ÞESSA ÞJÓNUSTUHANDBÓK. • EF EKKI ER FARIÐ AÐ ÞESSARI VIÐVÖRUN GETUR ÞAÐ VALDIÐ MEIÐSLUM ÞJÓNUSTUVEITANDA, STJÓRNANDA EÐA SJÚKLINGS VEGNA RAFLOSTS, VÉLRÆNNAR EÐA ANNARRAR HÆTTU.
-
i-5
GE HEALTHCARE DIRECTION 5394141, REVISION 5
LOGIQ™ P5 SEVICE MANUAL
VÝSTRAHA (CS)
• TENTO SERVISNÍ NÁVOD EXISTUJE POUZE V ANGLICKé M JAZYCE. • V Př íPADě , ŽE POSKYTOVATEL SLUŽEB ZÁKAZNÍKŮM POTř EBUJE Ná VOD V JINé M JAZYCE, JE ZAJIšTě Ní Př EKLADU DO ODPOVíDAJíCíHO JAZYKA ú KOLEM Zá KAZNíKA. • NEPROVÁDĚJTE ú DRŽBU TOHOTO ZAř íZENí, ANIŽ BYSTE SI Př Eč ETLI TENTO SERVISNÍ NÁVOD A POCHOPILI JEHO OBSAH. • V Př íPADě NEDODRŽOVá Ní Té TO VýSTRAHY Mů ŽE DOJíT ÚRAZU ELEKTRICKÁM PROUDEM PRACOVNíKA POSKYTOVATELE SLUŽEB, OBSLUŽNé HO PERSONá LU NEBO PACIENTů VLIVEM ELEKTRICKé HOP PROUDU, RESPEKTIVE VLIVEM K RIZIKU MECHANICKÉHO POŠKOZENÍ NEBO JINÉMU RIZIKU.
ADVARSEL
• DENNE SERVICEMANUAL FINDES KUN PÅ ENGELSK. • HVIS EN KUNDES TEKNIKER HAR BRUG FOR ET ANDET SPROG END ENGELSK, ER DET KUNDENS ANSVAR AT SØRGE FOR OVERSÆTTELSE. • FORSØG IKKE AT SERVICERE UDSTYRET MEDMINDRE DENNE SERVICEMANUAL ER BLEVET LÆST OG FORSTÅET. • MANGLENDE OVERHOLDELSE AF DENNE ADVARSEL KAN MEDFØRE SKADE PÅ GRUND AF ELEKTRISK, MEKANISK ELLER ANDEN FARE FOR TEKNIKEREN, OPERATØREN ELLER PATIENTEN.
WAARSCHUWING (NL)
• DEZE ONDERHOUDSHANDLEIDING IS ENKEL IN HET ENGELS VERKRIJGBAAR. • ALS HET ONDERHOUDSPERSONEEL EEN ANDERE TAAL VEREIST, DAN IS DE KLANT VERANTWOORDELIJK VOOR DE VERTALING ERVAN. • PROBEER DE APPARATUUR NIET TE ONDERHOUDEN VOORDAT DEZE ONDERHOUDSHANDLEIDING WERD GERAADPLEEGD EN BEGREPEN IS. • INDIEN DEZE WAARSCHUWING NIET WORDT OPGEVOLGD, ZOU HET ONDERHOUDSPERSONEEL, DE OPERATOR OF EEN PATIËNT GEWOND KUNNEN RAKEN ALS GEVOLG VAN EEN ELEKTRISCHE SCHOK, MECHANISCHE OF ANDERE GEVAREN.
BRĪDINĀJUMS (LV)
• šĪ APKALPES ROKASGRĀMATA IR PIEEJAMA TIKAI ANGĻU VALODĀ. • JA KLIENTA APKALPES SNIEDZĒJAM NEPIECIEŠAMA INFORMĀCIJA CITĀ VALODĀ, NEVIS ANGĻU, KLIENTA PIENĀKUMS IR NODROŠINĀT TULKOŠANU. • NEVEICIET APRĪKOJUMA APKALPI BEZ APKALPES ROKASGRĀMATAS IZLASĪŠANAS UN SAPRAŠANAS. • ŠĪ BRĪDINĀJUMA NEIEVĒROŠANA VAR RADĪT ELEKTRISKĀS STRĀVAS TRIECIENA, MEHĀNISKU VAI CITU RISKU IZRAISĪTU TRAUMU APKALPES SNIEDZĒJAM, OPERATORAM VAI PACIENTAM.
(DA)
i-6
-
GE HEALTHCARE DIRECTION 5394141, REVISION 5
LOGIQ™ P5 SEVICE MANUAL
ĮSPĖJIMAS (LT)
• ŠIS EKSPLOATAVIMO VADOVAS YRA IŠLEISTAS TIK ANGLŲ KALBA. • JEI KLIENTO PASLAUGŲ TEIKĖJUI REIKIA VADOVO KITA KALBA – NE ANGLŲ, VERTIMU PASIRŪPINTI TURI KLIENTAS. • NEMĖGINKITE ATLIKTI ĮRANGOS TECHNINĖS PRIEŽIŪROS DARBŲ, NEBENT VADOVAUTUMĖTĖS ŠIUO EKSPLOATAVIMO VADOVU IR JĮ SUPRASTUMĖTE • NEPAISANT ŠIO PERSPĖJIMO, PASLAUGŲ TEIKĖJAS, OPERATORIUS AR PACIENTAS GALI BŪTI SUŽEISTAS DĖL ELEKTROS SMŪGIO, MECHANINIŲ AR KITŲ PAVOJŲ.
ADVARSEL (NO)
• DENNE SERVICEHÅNDBOKEN FINNES BARE PÅ ENGELSK. • HVIS KUNDENS SERVICELEVERANDØR TRENGER ET ANNET SPRÅK, ER DET KUNDENS ANSVAR Å SØRGE FOR OVERSETTELSE. • IKKE FORSØK Å REPARERE UTSTYRET UTEN AT DENNE SERVICEHÅNDBOKEN ER LEST OG FORSTÅTT. • MANGLENDE HENSYN TIL DENNE ADVARSELEN KAN FØRE TIL AT SERVICELEVERANDØREN, OPERATØREN ELLER PASIENTEN SKADES PÅ GRUNN AV ELEKTRISK STØT, MEKANISKE ELLER ANDRE FARER.
OSTRZEŻENIE (PL)
ATENŢIE (RO)
• NINIEJSZY PODRĘCZNIK SERWISOWY DOSTĘPNY JEST JEDYNIE W JĘZYKU ANGIELSKIM. • JEś LI FIRMA ś WIADCZĄCA KLIENTOWI USłUGI SERWISOWE WYMAGA UDOSTę PNIENIA PODRę CZNIKA W Ję ZYKU INNYM NIŻ ANGIELSKI, OBOWIĄZEK ZAPEWNIENIA STOSOWNEGO TłUMACZENIA SPOCZYWA NA KLIENCIE. • NIE PRó BOWAć SERWISOWAć NINIEJSZEGO SPRZę TU BEZ UPRZEDNIEGO ZAPOZNANIA SIę Z PODRę CZNIKIEM SERWISOWYM. • NIEZASTOSOWANIE SIę DO TEGO OSTRZEŻENIA MOżE GROZIć OBRAŻENIAMI CIAłA SERWISANTA, OPERATORA LUB PACJENTA W WYNIKU PORAŻENIA PRĄDEM, URAZU MECHANICZNEGO LUB INNEGO RODZAJU ZAGROŻEń . • ACEST MANUAL DE SERVICE ESTE DISPONIBIL NUMAI ÎN LIMBA ENGLEZĂ. • DACĂ UN FURNIZOR DE SERVICII PENTRU CLIENŢI NECESITĂ O ALTĂ LIMBĂ DECÂT CEA ENGLEZĂ, ESTE DE DATORIA CLIENTULUI SĂ FURNIZEZE O TRADUCERE. • NU ÎNCERCAŢI SĂ REPARAŢI ECHIPAMENTUL DECÂT ULTERIOR CONSULTĂRII ŞI ÎNŢELEGERII ACESTUI MANUAL DE SERVICE. • IGNORAREA ACESTUI AVERTISMENT AR PUTEA DUCE LA RĂNIREA DEPANATORULUI, OPERATORULUI SAU PACIENTULUI ÎN URMA PERICOLELOR DE ELECTROCUTARE, MECANICE SAU DE ALTĂ NATURĂ.
-
i-7
GE HEALTHCARE DIRECTION 5394141, REVISION 5
ОСТОРОЖНО! (RU)
UPOZORNENIE (SK)
VARNING (SV)
DİKKAT (TR)
i-8
LOGIQ™ P5 SEVICE MANUAL
• Да н н о е рук о в о дс т в о п о о б с луж и в а н и ю ПРЕДОСТАВЛЯЕТСЯ т о ль к о н а а н г ли й с к о м Яз ы к е . • Ес ли с е рв и с н о МУ ПЕРСОНАЛУ к ли е н т а н е о б х о ди мо рук о в о дс т в о н е н а а н г ли й с к о м ЯЗЫКЕ, к ли е н т у с ле дуе т с а мо с т о Ят е ль н о ОБЕСПЕЧИТЬ п е ре в о д. • ПЕРЕД ОБСЛУЖИВАНИЕМ ОБОРУДОВАНИЯ ОБЯЗАТЕЛЬНО ОБРАТИТЕСЬ К ДАННОМУ РУКОВОДСТВУ И ПОЙМИТЕ ИЗЛОЖЕННЫЕ В НЕМ СВЕДЕНИЯ. • НЕСОБЛЮДЕНИЕ УКАЗАННЫХ ТРЕБОВАНИЙ МОЖЕТ ПРИВЕСТИ К ТОМУ, ЧТО СПЕЦИАЛИСТ ПО ТЕХОБСЛУЖИВАНИЮ, ОПЕРАТОР ИЛИ ПАЦИЕНТ ПОЛУЧАТ УДАР ЗЛЕКТРИЧЕСКИМ ТОКОМ, МЕХАНИЧЕСКУЮ ТРАВМУ ИЛИ ДРУГОЕ ПОВРЕЖДЕНИЕ. • TÁTO SERVISNÁ PRÍRUČKA JE K DISPOZíCII LEN V ANGLIČTINE. • AK ZÁKAZNÍKOV POSKYTOVATEĽ SLUŽIEB VYŽADUJE INÝ JAZYK AKO ANGLIČTINU, POSKYTNUTIE PREKLADATEĽSKÝCH SLUŽIEB JE ZODPOVEDNOSŤOU ZÁKAZNÍKA. • NEPOKÚŠAJTE SA VYKONÁVAŤ SERVIS ZARIADENIA SKÔR, AKO SI NEPREČÍTATE SERVISNÚ PRÍRUČKU A NEPOROZUMIETE JEJ. • ZANEDBANIE TOHTO UPOZORNENIA Mô ŽE VYÚSTIŤ DO ZRANENIA POSKYTOVATEĽA SLUŽIEB, OBSLUHUJú CEJ OSOBY ALEBO PACIENTA ELEKTRICKýM PRú DOM, PRÍPADNE DO MECHANICKé HO ALEBO INé HO NEBEZPEč ENSTVA. • DEN HÄR SERVICEHANDBOKEN FINNS BARA TILLGÄNGLIG PÅ ENGELSKA. • OM EN KUNDS SERVICETEKNIKER HAR BEHOV AV ETT ANNAT SPRÅK ÄN ENGELSKA ANSVARAR KUNDEN FÖR ATT TILLHANDAHÅLLA ÖVERSÄTTNINGSTJÄNSTER. • FÖRSÖK INTE UTFÖRA SERVICE PÅ UTRUSTNINGEN OM DU INTE HAR LÄST OCH FÖRSTÅR DEN HÄR SERVICEHANDBOKEN. • OM DU INTE TAR HÄNSYN TILL DEN HÄR VARNINGEN KAN DET RESULTERA I SKADOR PÅ SERVICETEKNIKERN, OPERATÖREN ELLER PATIENTEN TILL FÖLJD AV ELEKTRISKA STÖTAR, MEKANISKA FAROR ELLER ANDRA FAROR. • BU SERVİS KILAVUZU YALNIZCA İNGİLİZCE OLARAK SAĞLANMIŞTIR. • EĞER MÜŞTERİ TEKNİSYENİ KILAVUZUN İNGİLİZCE DIŞINDAKİ BİR DİLDE OLMASINI İSTERSE, KILAVUZU TERCÜME ETTİRMEK MÜŞTERİNİN SORUMLULUĞUNDADIR. • SERVİS KILAVUZUNU OKUYUP ANLAMADAN EKİPMANLARA MÜDAHALE ETMEYİNİZ. • BU UYARININ GÖZ ARDI EDİLMESİ, ELEKTRİK ÇARPMASI YA DA MEKANİK VEYA DİĞER TÜRDEN KAZALAR SONUCUNDA TEKNİSYENİN, OPERATÖRÜN YA DA HASTANIN YARALANMASINA YOL AÇABİLİR.
-
GE HEALTHCARE DIRECTION 5394141, REVISION 5
LOGIQ™ P5 SEVICE MANUAL
(JA)
(ZH-CN)
(KO)
-
i-9
GE HEALTHCARE DIRECTION 5394141, REVISION 5
LOGIQ™ P5 SEVICE MANUAL
DAMAGE IN TRANSPORTATION All packages should be closely examined at time of delivery. If damage is apparent write “Damage In Shipment” on ALL copies of the freight or express bill BEFORE delivery is accepted or “signed for” by a GE representative or hospital receiving agent. Whether noted or concealed, damage MUST be reported to the carrier immediately upon discovery, or in any event, within 14 days after receipt, and the contents and containers held for inspection by the carrier. A transportation company will not pay a claim for damage if an inspection is not requested within this 14 day period.
CERTIFIED ELECTRICAL CONTRACTOR STATEMENT - FOR USA ONLY All electrical Installations that are preliminary to positioning of the equipment at the site prepared for the equipment shall be performed by licensed electrical contractors. Other connections between pieces of electrical equipment, calibrations and testing shall be performed by qualified GE Healthcare personnel. In performing all electrical work on these products, GE will use its own specially trained field engineers. All of GE’s electrical work on these products will comply with the requirements of the applicable electrical codes. The purchaser of GE equipment shall only utilize qualified personnel (i.e., GE’s field engineers, personnel of third-party service companies with equivalent training, or licensed electricians) to perform electrical servicing on the equipment.
OMISSIONS & ERRORS If there are any omissions, errors or suggestions for improving this documentation, please contact the GE Healthcare Global Documentation Group with specific information listing the system type, manual title, part number, revision number, page number and suggestion details. Mail the information to: Service Documentation, 9900 Innovation Drive (RP-2123), Wauwatosa, WI 53226, USA. GE Healthcare employees should use the iTrak System to report all documentation errors or omissions.
SERVICE SAFETY CONSIDERATIONS DANGER
DANGEROUS VOLTAGES, CAPABLE OF CAUSING DEATH, ARE PRESENT IN THIS EQUIPMENT. USE EXTREME CAUTION WHEN HANDLING, TESTING AND ADJUSTING.
WARNING Use all Personal Protection Equipment (PPE) such as gloves, safety shoes, safety
glasses, and kneeling pad, to reduce the risk of injury. For a complete review of all safety requirements, see the Chapter 1, Safety Considerations section in the Service Manual.
i-10
-
GE HEALTHCARE DIRECTION 5394141, REVISION 5
LOGIQ™ P5 SEVICE MANUAL
LEGAL NOTES The contents of this publication may not be copied or duplicated in any form, in whole or in part, without prior written permission of GE Healthcare. GE Healthcare may revise this publication from time to time without written notice.
TRADEMARKS All products and their name brands are trademarks of their respective holders.
COPYRIGHTS All Material Copyright© 2011, 2014 by General Electric Company Inc. All Rights Reserved.
-
i-11
GE HEALTHCARE DIRECTION 5394141, REVISION 5
LOGIQ™ P5 SEVICE MANUAL
Revision History Revision
Date
Reason for change
1
May 3, 2010
Initial Release
2
Nov 2, 2010
PHI Update
3
Mar 2, 2011
Software version update
4
May 16, 2011
Add Mitsubishi Printer (P95 series)
5
Aug 26, 2014
Correct revision on the header
List of Effected Pages(LOEP)
i-12
Pages
Revision
Pages
Revision
Pages
Revision
Title Page
5
4-1 to 4-54
5
10-1 to 10-30
5
Warnings i-3 to i-12
5
5-1 to 5-60
5
Back Cover
N/A
TOC i-13 to i-28
5
6-1 to 6-8
5
1-1 to 1-19
5
7-1 to 7-37
5
2-1 to 2-12
5
8-1 to 8-229
3
3-1 to 3-26
5
9-1 to 9-23
5
-
GE HEALTHCARE DIRECTION 5394141, REVISION 5
LOGIQ™ P5 SERVICE MANUAL
Table of Contents CHAPTER 1 Introduction Overview...1-1 Purpose of Chapter 1...1-1 Purpose of Service Manual...1-1 Typical Users of the Basic Service Manual...1-2 LOGIQ™ P5 Models Covered by this Manual...1-2 Purpose of Operator Manual(s)...1-2 Important Conventions...1-3 Conventions Used in Book...1-3 Standard Hazard Icons...1-4 Product Icons...1-5 WEEE Label...1-7 Safety Considerations...1-12 Introduction...1-12 Human Safety...1-12 Mechanical Safety...1-12 Electrical Safety...1-13 Label Locations...1-14 Dangerous Procedure Warnings...1-16 Lockout/Tagout Requirements (For USA Only)...1-16 EMC, EMI, and ESD...1-17 Electromagnetic Compatibility (EMC)...1-17 CE Compliance...1-17 Electrostatic Discharge (ESD) Prevention...1-17 Customer Assistance...1-18 Contact Information...1-18 System Manufacturer...1-19
Table of Contents
i-13
GE HEALTHCARE DIRECTION 5394141, REVISION 5
LOGIQ™ P5 SERVICE MANUAL
CHAPTER 2 Pre-Installation Overview...2-1 Purpose of chapter 2...2-1 General Console Requirements...2-2 Console Environmental Requirements...2-2 Electrical Requirements...2-3 EMI Limitations...2-5 Scan Probe Environmental Requirements...2-6 Facility Needs...2-7 Purchaser Responsibilities...2-7 Required Features...2-8 Desirable Features...2-8 Recommended and Alternate Ultrasound Room Layout...2-9 Networking Pre-installation Requirements...2-10
i-14
-
GE HEALTHCARE DIRECTION 5394141, REVISION 5
LOGIQ™ P5 SERVICE MANUAL
CHAPTER 3
Installation Overview... 3-1 Purpose of chapter 3... 3-1 Installation Reminders... 3-2 Average Installation Time... 3-2 Installation Warnings... 3-2 Safety Reminders... 3-3 Receiving and Unpacking the Equipment... 3-4 Moving into Position... 3-9 Adjusting System Clock... 3-9 Product Locator Installation Card... 3-9 Preparing for Installation... 3-10 Verify Customer Order... 3-10 Physical Inspection... 3-10 EMI Protection... 3-10 Completing the Installation... 3-11 Power On/Boot Up... 3-11 Power Off/ Shutdown... 3-14 Transducer Connection... 3-15 System Configuration... 3-16 System Specifications... 3-16 Electrical Specifications... 3-18 On-Board Optional Peripherals... 3-18 External I/O Connector Panel... 3-19 Video Specification... 3-21 Setting VCR (Mitsubishi MD3000) USB Interface... 3-22 Available Probes... 3-23 Software/Option Configuration... 3-23 Connectivity Installation Worksheet... 3-24 Insite IP Address Configuration... 3-25 Loading Base System Software... 3-25 Loading Base system Software... 3-25 -
i-15
GE HEALTHCARE DIRECTION 5394141, REVISION 5
LOGIQ™ P5 SERVICE MANUAL
Warnings...3-25 Warnings...3-25 Paperwork...3-26 Product Locator Installation...3-26 User Manual(s)...3-26
i-16
-
GE HEALTHCARE DIRECTION 5394141, REVISION 5
LOGIQ™ P5 SERVICE MANUAL
CHAPTER 4 Functional Checks Overview... 4-1 Purpose of Chapter 4... 4-1 Required Equipment... 4-1 General Procedure... 4-2 Power On/Boot Up... 4-2 Power Off / Shutdown... 4-4 System Features... 4-5 System B/M-Mode Checks... 4-8 System CFM and PWD Checks... 4-9 Basic Measurements... 4-10 Probe/Connectors Usage... 4-12 Using Cine... 4-13 Image Management (QG)... 4-14 Using the DVD-R... 4-15 Backup and Restore Database, Preset Configurations and Images... 4-19 ECG Check Out... 4-25 Software Configuration Checks... 4-25 Peripheral Checks... 4-26 Monitor Function Checks... 4-27 15" LCDMON II Assy & LCD Panel with filter Function Validation Procedure 4-27 15" OSD Key Assy Function Validation Procedure... 4-28 Keyboard Function Checks... 4-29 Main Keyboard Assy Function Validation Procedure... 4-29 Sub Keyboard Assy Function Validation Procedure... 4-32 Trackball Assy validation... 4-32 A/N Key assy validation... 4-32 Freeze key validation... 4-32 TGC key assay / TGC Knob Set validation... 4-33 Sub Keyboard Encoder Knob Set validation... 4-33 Mechanical Function Checks... 4-34 Cover Parts Function Validation... 4-34 LCD plastic filter Function Validation Procedure... 4-35 -
i-17
GE HEALTHCARE DIRECTION 5394141, REVISION 5
LOGIQ™ P5 SERVICE MANUAL
Air filter set Function Validation Procedure...4-35 TGC key assy/TGC Knob Set, Sub keyboard encoder Knob Set, Keycap set, Main Keyboard Encoder Knob set Function Validation Procedure...4-36 Cup holder Function Validation Procedure...4-37 Front caster/Rear caster Function Validation Procedure...4-38 Probe holder Function Validation Procedure...4-39 Flexible LCD Arm Function Validation Procedure...4-40 Board Function Checks...4-41 CL1TRX Assy / BL1TRX Assy Function Validation Procedure...4-41 ACWD Assy Function Validation Procedure...4-42 Probe Assessment Diagnostic Test Validation Procedure...4-45 SYSCONML Assy Function Validation Procedure...4-47 APS/APS Pro Assy PCB Function Validation Procedure...4-48 P3RLY,P2RLY and P2RLY with Dummy Assy function check procedure . .4-49 SOM Function Validation Procedure...4-50 ASIG Assy Function Validation Procedure...4-50 BackPlane Assy Function Validation Procedure...4-51 Nest fan Function Validation Procedure...4-52 Transbox Function Validation Procedure...4-52 ACPC Assy set Function Validation Procedure...4-52 Transbox Assy Function Validation Procedure...4-53 Fuse set Function Validation Procedure...4-53 ARP Assy Function Validation Procedure...4-53 ASIG ASSY Function Validation Procedure...4-53 Site Log...4-54
i-18
-
GE HEALTHCARE DIRECTION 5394141, REVISION 5
LOGIQ™ P5 SERVICE MANUAL
CHAPTER 5 Components and Functions (Theory) Overview... 5-1 Purpose of Chapter 5... 5-1 General Information... 5-2 Block Diagram... 5-3 LOGIQ™ P5 Block Diagram... 5-3 LOGIQ™ A5/A5Pro Block Diagram... 5-6 Main Board Detail... 5-9 P3RLY and P2RLY... 5-11 CL1TRX and BL1TRX... 5-12 SYSCONPM(SYSCONCM)... 5-16 SOM Module... 5-19 Top Console... 5-26 Keyboard... 5-26 LOGIQ™ P5 Monitor II and LOGIQ™ A5/A5Pro Monitor II... 5-28 ARP (Rear Panel)... 5-30 Input/Output Signals for peripheral... 5-31 Power Diagrams... 5-32 Overview... 5-32 TRANSBOX(AC Power)... 5-32 APS/APS Pro (LV Power & HV Power)... 5-33 AC Power Outlet for Peripheral... 5-34 Cable Connection... 5-35 Overview... 5-35 Internal Cable... 5-35 Peripherals and Cable connection... 5-36 Filters... 5-39 Filters... 5-39 Fans... 5-39 Service Platform... 5-40 Introduction... 5-40 Global Service User Interface (GSUI)... 5-41 Service Home Page... 5-42 -
i-19
GE HEALTHCARE DIRECTION 5394141, REVISION 5
LOGIQ™ P5 SERVICE MANUAL
Error Logs Tab...5-43 Diagnostics...5-45 Image Quality...5-46 Calibration...5-46 Configuration...5-47 Utilities...5-49 Replacement...5-50 PM...5-50 Remote Software/Option Installation and Updates...5-51 RFS (Service For Request)...5-52 General...5-52 System Checkout Procedure...5-52 Sending RFS Procedure...5-54 Machine RFS...5-56 General...5-56 Enabling MRFS...5-56 Fast Polling...5-59 General...5-59 Enabling Fast Polling...5-59
i-20
-
GE HEALTHCARE DIRECTION 5394141, REVISION 5
LOGIQ™ P5 SERVICE MANUAL
CHAPTER 6 Service Adjustments Overview... 6-1 Purpose of this chapter 6... 6-1 Regulatory... 6-1 Monitor Adjustments... 6-2 Rotate and tilt the monitor... 6-2 Brightness and Contrast... 6-3 LCD Plastic filter... 6-4 Flexible LCD arm - locking mechanism... 6-6 Trackball Cleaning... 6-7
-
i-21