Hill-Rom

Liko Mobile Patient Lifts and Sit & Stands

Golvo 7000 series Instruction Guide May 2012

Instruction Guide

16 Pages

Table of Contents Safety Instructions ... 2 Definitions... 3 Technical Data... 3 Measurements... 4 Assembly... 5 Disassembly ... 7 Operation... 8 Charging the Batteries... 11 Maximum Load... 12 Recommended Lifting Accessories... 12 Simple Troubleshooting... 15 Care and Maintenance... 16  NOTE! This instruction guide contains information that is important for users of the product. A complete understanding of the contents of the instruction guide is essential, and only personnel who are well informed should use the equipment. Remember to keep the instruction guide readily accessible for users of the product.  Safety Instructions Before using the lift for the first time, make certain that: • the lift is assembled according to the instructions; • the lifting equipment is correctly applied to the lift; • the batteries have been charged for at least 6 hours; • you have read the instruction guides for the lift and lifting accessories; • personnel using the equipment have received appropriate instructions and training. Before lifting always make certain that: • the lift strap is not twisted or worn and that it can move freely in and out of the lift unit; • the lifting accessories is selected appropriately in terms of type, size, material and design with regard to the patient’s needs; • lifting accessories are not damaged; • the lifting accessory is correctly applied to the lifting equipment; • the lifting accessory is correctly and securely applied to the patient, so that no personal injury can occur; •  the sling’s strap loops are correctly fastened to the slingbar hooks when the sling strap is extended, but before the patient is lifted from the underlying surface. Never leave a patient unattended in a lifting situation!  Golvo 7000 ES/7007 ES/7007 LowBase are tested by an accredited testing institute. Golvo 7000 ES/7007 ES/7007 LowBase comply with the requirements according to IEC 60601-1, IEC 60601-1-2, EN ISO 10535, UL-60601-1 and CAN/CSA C22.2 No. 606.1. Particular care must be taken when using strong sources of electromagnetic interference, such as diathermy, etc, so that cables are not positioned on or near the lift. If you have questions, please consult the responsible assistive-device technician or the supplier. This equipment is not suitable for use in the presence of flammable mixtures. Maximum load: 200 kg (440 lbs.) Golvo • 7EN140102-04  2  w w w . l i k o . com
File Type: PDF
File Size: 1.87 MB
File Name: Golvo 7000 series Instruction Guide May 2012.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions