Hill-Rom

Liko Overhead Lifts

Likorall 200 Instruction Guide Feb 2012

Instruction Guide

12 Pages

Table of Contents Safety Instructions ...2 Technical Data ...3 Definitions...3 Assembly...4 Operation...5-6 Charging the Batteries ...7 Transferring from Room to Room...8 Maximum Load...9 Recommended Lifting Accessories...9-10 Simple Troubleshooting... 11 Care and Maintenance...12  NOTE! This instruction guide contains important information for product users. All who use the product should review and completely understand the contents of the instruction guide. Remember to keep the instruction guide in a place where it is always available to those using the product.  Safety Instructions Before using the first time make sure that: • the lift is assembled in accordance with the assembly instruction • the lifting equipment is thoroughly attached to the lift • the batteries are charged for at least 8 hours • you have read the instruction guides for the lift and lifting accessories • personnel using the lift are informed of the correct use of the lift and lifting accessories.  Before lifting always ensure that: • the lift strap is not twisted or worn and can move in and out of the lift unit freely • the lifting accessories are not damaged • the sling is correctly and securely applied to the patient in order to prevent injuries from occurring • the lifting accessory is correctly applied to the lifting equipment • the sling strap loops are correctly connected to the sling bar hooks when the sling´s strap is extended, but before the patient is lifted from the underlying surface • the emergency lowering device is freely suspended (not interfering with surrounding parts) • the correct lifting accessory has been chosen, with respect to type, size, material and version in relation to the needs of the patient.  Likorall 200 has been tested by accredited testing institutes and complies with the requirements for MDD Class I products (MDD 93/42/EEC). Likorall complies with the requirements for IEC 60601-1, IEC 60601-1-2, EN ISO 10535, UL-60601-1 and CAN/ CSA C22.2 No.601.1. No modification of this product is allowed. Contact Liko for further information. Particular care must be observed when using strong sources of potential disturbance, such as diathermy, etc, so that diathermy cables are not positioned on or near the lift. If you have questions, please consult the responsible assistive-device technician or the supplier. The lift may not be used in areas where flammable mixtures may occur, for example in areas where flammable goods are stored. Max. load: 200 kg / 440 Ibs. Likorall 200 • 7EN120114-03  2  www.liko.com
File Type: PDF
File Size: 1.36 MB
File Name: likorall_200_instruction_guide_feb_2012.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions