Hospira

Lifecare PCA Infusion Pumps

LifeCare PCA Infusion System Priming Reference Guide Rev F Feb 2016

Product Reference Guide

1 Page

Product Reference Guide  LifeCare PCA™ Infusion System Priming the Vial and Administration Set Prior to priming, inspect the vial for damage, including leaks and cracks, and inspect the administration set for anomalies and/or irregularities.  Assembling a Vial and Tubing:  Remove the yellow caps from the vial and the needle cover of the injector. Inspect vial for leaks and cracks.  Attach the injector to the vial, turning clockwise until secure.  Remove yellow luer cover from the injector and slowly depress the flange on the injector to remove excess air from the vial.  Connect the Pressure Activated Valve (PAV) female end of the set to the injector.  Priming the Set:  Close the green slide clamp on the KVO (Keep Vein Open) side of the LifeCare PCA administration set.  Invert the vial and administration set, holding the vial vertically on a flat surface, with the administration set pointing up from the top of the syringe.  Using two hands, slowly depress the flange on the injector.  To prime the filter, invert filter and tap lightly to expel air. Continue pushing the injector until fluid exits the distal end of the set.  Close the orange slide clamp on the PCA side of the administration set.  Administration Set  Injector 1  2  1  5  3  6  10  2  4 3 PCA Line  7  8  9  3  KVO Side  To prime the KVO side, ensure that the orange (or white) slide clamp is closed on the PCA side. Open the green slide clamp on the KVO side.  Attach the primed administration set to the female adapter and prime the KVO side until fluid is observed at the distal end of the administration set.  WARNING: Failure to completely flush narcotic from distal set could result in unintended bolus. Ensure orange slide clamp is closed prior to loading or manipulating vial.  1. Injector 2. Pressure activated valve with cap 3. Slide clamp 4. Y-junction 5. Microbore/ minibore tubing  6. Distal male luer with cover 7. Backcheck valve 8. Macrobore tubing 9. Female luer with cover 10. Filter  1. Needle cover 2. Injector 3. Luer cover  CAUTION: Not for high pressure infusion. > Not for gravity administration. > Do not administer blood, blood products, emulsions, suspensions or any medication not totally soluble in solution through the filter. > If these fluids are to be given, they should be administered through the Y-site below the in-line filter. > The KVO side of the set must be capped and slide clamp engaged if container is not attached. > Ensure no fluid flow at distal end of the set. If flow is observed, do not use the set. > Change at least every 96 hours. References used: 430-97354-001 (F, 2016-02)_LCPCA with ICU Medical MedNet Infusion System Operating Manual © 2019 ICU Medical Inc.  |  US-ED04-0066-0319 |  For Distribution  |  For safe and proper use, refer to the appropriate manual, guide, or instructions for use.  800.824.7890 | www.icumed.com
File Type: PDF
File Size: 1.43 MB
File Name: LifeCare PCA Infusion System Priming the Vial and Administration Set Product Reference Guide Rev F Feb 2016.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions