Hospira

Plum Infusion Pumps

PLUM 360 and PLUM A+ Product Decontamination Reference Guide Rev A Sept 2017

Decontamination Reference Guide

1 Page

Product Reference Guide  Plum 360™ and Plum A+™ ICU Medical Device Cleaning Solutions  Approved Cleaning* Agents The following solutions have been thoroughly tested and validated by ICU Medical and are approved for use with the infusion devices listed below. Plum 360 and Plum A+ Cleaning Solution(s)  ASP Enzol™ ASP Cidezyme™ (Outside US) Use per manufacturer’s recommendations and instructions in the appropriate manual  Disinfecting Solution(s)  Clorox™ Germicidal Bleach (8.25% concentration) Do not exceed 1 part bleach in 10 parts water  *Disinfecting properties of cleaning solutions vary, and not all cleaning solutions are sanitizers. Check product labeling or consult the manufacturer for specific information.  Alternate Cleaning Agents  Do Not Use  These solutions have only been tested for mechanical and chemical compatibility for ESC (environmental stress cracking). ICU Medical cannot attest to the effectiveness of these solutions. Therefore organizations are encouraged to monitor the effectiveness of the solution as facility infection prevention protocols are followed.  > Accel® Disinfectant TB Wipes > Sani-Cloth® AF3 Germicidal Disposable Wipe > Sani-Cloth® Plus Germicidal Disposable Cloth > Super Sani-Cloth® Germicidal Disposable Wipe > Cidex® glutaraldehyde based disinfectant > Methyl Ethyl Ketone (MEK) > Virex® Organic Ammonium Chloride based disinfectant > Ethanol (Ethyl Alcohol) > 70% Isopropanol (isopropyl alcohol or IPA) > Dimethyl Benzyl Ammonium Chloride > Didecyl Dimethyl Ammonium Chloride > Clinell Universal Sanitising Wipes > Cleaning or disinfecting products not listed as approved for use.  > ECOLAB OxyCide™ > Wexford Labs Wex-cide 128 > Johnson & Johnson/ASP® CIDEX® OPA > Sani-Cloth® Bleach Germicidal Disposable Wipes > Clorox Healthcare® Bleach Germicidal Wipes > Clorox Healthcare® Hydrogen Peroxide Cleaner Disinfectant Wipes > Dispatch® Hospital Cleaner Disinfectant Towels with Bleach  CAUTION: Use all cleaning solutions as specified by the manufacturer, to avoid infuser damage. Use only recommended cleaning solutions and follow manufacturer’s recommendations regarding dilution. Using cleaning solutions not recommended by ICU Medical may result in product damage. Instructions on how to clean and disinfect the infusion device for reprocessing can be found in the associated Technical Service Manual. You may also call the ICU Medical Technical Support Center at 1-800-241-4002, or visit www.icumed.com for further information.  Only. For safe and proper use, refer to the appropriate manual, guide, or instructions for use. References: 430-98340-003__A, 2017-09_Plum360 System Operating Manual_15.1x 430-98341-003_A_2017-09_Plum 360 Technical Service Manual  © 2020 ICU Medical Inc.  |  US-ED04-0063-0420R1 |  For Distribution  800.824.7890 | www.icumed.com
File Type: PDF
File Size: 152 KB
File Name: PLUM 360 and PLUM A+ Product Decontamination Reference Guide Rev A Sept 2017.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions